• Title/Summary/Keyword: assessment of safety

Search Result 5,533, Processing Time 0.065 seconds

Verification on Separation Distance Criteria when Transporting Dangerous Goods in Korea Railroad (국내 철도 위험물 운송 시 격리차 운영기준 안전성 검증)

  • Lee, Byeongwoo;Park, Dasung;Kang, Taesun;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.2
    • /
    • pp.28-33
    • /
    • 2019
  • After the Tianjin Port explosion on 2015, it is highlighted that securing safety for dangerous goods in Korea and try to establish safety standards for railroad dangerous substances transport. In Korea, the regulation for the transport of dangerous goods is stipulated to need 3 buffer cars. However, It is inefficient that 3 buffer cars. because 3 buffer cars, increase transportation too much costs in transit and it is too strict compared to other country rules. The purpose of this study was to improve transportation efficiency by mitigating the criteria for isolated railroads through rational safety assessment. In order to verify this, we used a risk assessment software which is PHAST 7.2 developed by DNV GL. We calculated safety distances that could prevent ignitions setting up scenarios when relief system work installed on a train loaded with propylene, nonane. As a result, we confirmed that buffer cars can be reduced from three to one. This result would be implemented in the application of Korail.

A Study on Application Method & System Introduction of Laboratory Pre-hazards Risk Analysis (연구실 사전유해인자위험분석 적용방안 및 제도도입 연구)

  • Cho, Nam Joon;Ji, Yong Gu
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.126-135
    • /
    • 2016
  • The purpose of this study is to develop risk assessment techniques and institutional analysis of domestic and international, the management techniques that can efficiently manage the harmful factor of the laboratory and to present the institutional measures that can be efficiently implemented. Due to a variety of adverse factors of laboratory, accidents of laboratory of various forms have occurred, but there is no risk assessment system in order to manage this effectively. So, we investigated this domestic existing risk assessment methods and the outside of the risk assessment system, and also analyzed accidents of domestic laboratory that occurred in 2014. In addition, we targeted the 24 laboratories in 21 universities to investigate the management of harmful factors of the laboratory and performed applying test for 12 domestic laboratories. Existing risk evaluation system, such as PMS, SMS, off-site impact assessment, since the industrial site is the subject, is a difficult problem to be directly applied to the laboratory of the research institute. So, we implemented management status and harmful factors survey and classified the research and development activities based on this data. Finally we developed "pre-hazards risk analysis method" to create each of the safety management measures. In addition, research activities personnel conducted voluntarily risk assessment, which is shared by institutions and government. It is presented the institutional system for safety management of laboratory. Its result, pre-hazards risk analysis method and institutionalization scheme will be able to achieve laboratory accident prevention system.

Safety Assessment of Corrosion-damaged Steel Structure using Imprecise Reliability (불확실 신뢰도 기법을 이용한 부식된 강구조물의 안전도평가)

  • Choi, Hyun Ho;Cho, Hyo Nam;Seo, Jong Won;Sun, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.293-300
    • /
    • 2006
  • There is a high degree of uncertainty in measurements of the thickness or the loss of thickness of corroded elements. Generally the thickness of corroded elements varies from one location of the element to another depending on the degree of corrosion, which makes the safety assessment difficult. Therefore, a procedure for safety assessment of corrosion- damaged steel structures using an imprecise reliability is proposed in this paper. The proposed safety assessment procedure using the imprecise reliability was also applied to a cable-stayed bridge in Korea to demonstrate its effectiveness and applicability. Since there is a large variation in measurements of the thickness of corroded elements, the thickness of corroded elements was considered as the imprecise element. This variation was found to be directly related to the degree of corrosion. Therefore, the variation increases as the degree of corrosion increases. Based on the comparative observations between the conventional reliability and the imprecise reliability, it is suggested that the imprecise reliability analysis derived based on the subjective or statistical judgment of conditional independence could be successfully utilized for the risk or safety assessment of corrosion-damaged structures.

Concept Design of Fire Safety Module for SV20 Service in the Korean e-Navigation System

  • Kim, Byeol;Moon, Serng-Bae;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.42 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • The Korean e-Navigation system is a Korean approach to correspond with implementation of IMO e-Navigation. It provides five services, among them SV20 service, a ship remote monitoring system that collects and processes sensor information related to fire, navigation, and seakeeping performance safety. The system also detects abnormal conditions such as fires, capsizing, sinking, navigation equipment failure during navigation, and calculates the safety index and determines the emergency level. According to emergency level, it provides appropriate emergency response guidance for the onboard operator. The fire safety module is composed of three sub-modules; each module is the safety index sub-module, the emergency level determination sub-module and emergency response guidance sub-module. In this study, operational concept of the fire safety module in SV20 service is explained, and fire safety assessment factors are estimated, to calculate the fire safety index. Fire assessment factors included 'Fire detector position factor,' 'Smoke diffusion rate factor,' and 'Fire-fighting facilities factor.'

A Study on Risk Assessment Model for Occupational Health and Safety Management System - Focused on Organization Using Chemical Material - (안전보건경영시스템 구축을 위한 위험성평가모델에 대한 연구 - 화학물질 사용조직을 중심으로 -)

  • Cho, Kyeong-Seok;Lee, Chang-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.1-9
    • /
    • 2014
  • The occupational health and safety accidents were continuously increased during handling, usage and manufacturing the chemical materials according to increase of small and medium sized enterprises in domestic industries. These accidents mainly resulted from insufficient occupational health and safety management and deteriorative facilities and focused on corresponding operation to minimize the damage of accidents after occurrence. But, it was required that we grasped the occurrence causes of occupational health and safety risk in handling, usage and manufacturing the chemical materials and develop the adequate corresponding operation and system according to the possible occurrence of occupational health and safety risk. This study deals with the development of risk assessment model to derive the risk and important risk of occupational health and safety and then help to construct the self-controlled occupational health and safety system for small and medium sized enterprises handling the chemical materials.

Natech Risk Assessment of Chemical Facilities in the Event of Earthquake in Korea using RAPID-N (RAPID-N을 이용한 국내 지진 발생 시 화학시설 Natech 위험성 평가)

  • Park, Jaehyuk;Yeon, Eungjin;Lee, Hak Tae;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.111-118
    • /
    • 2019
  • Accidents occurring due to natural disasters in chemical process facilities where technologies are concentrated can cause secondary damage. The concept of the relationship between natural disasters and highly intensive technologies has evolved into the Natech (Natural Hazards Triggered Technological Disaster) research. Currently, the number of earthquakes is increasing all over the Korean peninsula. To assess the risk of Natech when an earthquake has occurred in South Korea, the Rapid Natech Risk Assessment Tool (RAPID-N) developed by the European Commission's Joint Research Center (EC JRC) was used in the present study. The RAPID-N can be used for Natech risk assessment based on mapping and can be utilized for sufficient preparation for reduction of the effects of Natech accidents. A total of 261 chemical facilities actually existing in Pohang were initially analyzed to select eight facilities and the Pohang earthquake that occurred in 2017 was implemented in the RAPID-N utilizing the shake map. High risk areas were selected through Natech risk assessments for the selected eight work places and countermeasures for the areas were suggested. High risk areas exist depending on the location, since the damage influence ranges could be overlapped and each chemical facility has an independent probability of Natech. Therefore, studies on Natech emergency plans and emergency evacuation routes should be actively conducted considering such high risk areas. The present study was conducted to demonstrate the feasibility of Natech risk assessment in South Korea through the RAPID-N. These findings can be used as a reference material to lay a foundation for Natech risk assessment and related policies in South Korea.

Risk Assessment Principle for Engineered Nanotechnology in Food and Drug

  • Hwang, Myung-Sil;Lee, Eun-Ji;Kweon, Se-Young;Park, Mi-Sun;Jeong, Ji-Yoon;Um, Jun-Ho;Kim, Sun-Ah;Han, Bum-Suk;Lee, Kwang-Ho;Yoon, Hae-Jung
    • Toxicological Research
    • /
    • v.28 no.2
    • /
    • pp.73-79
    • /
    • 2012
  • While the ability to develop nanomaterials and incorporate them into products is advancing rapidly worldwide, understanding of the potential health safety effects of nanomaterials has proceeded at a much slower pace. Since 2008, Korea Food and Drug Administration (KFDA) started an investigation to prepare "Strategic Action Plan" to evaluate safety and nano risk management associated with foods, drugs, medical devices and cosmetics using nano-scale materials. Although there are some studies related to potential risk of nanomaterials, physical-chemical characterization of nanomaterials is not clear yet and these do not offer enough information due to their limitations. Their uncertainties make it impossible to determine whether nanomaterials are actually hazardous to human. According to the above mention, we have some problems to conduct the human exposure risk assessment currently. On the other hand, uncertainty about safety may lead to polarized public debate and to businesses unwillingness for further nanotechnology investigation. Therefore, the criteria and methods to assess possible adverse effects of nanomaterials have been vigorously taken into consideration by many international organizations: the World Health Organization, the Organization for Economic and Commercial Development and the European Commission. The object of this study was to develop risk assessment principles for safety management of future nanoproducts and also to identify areas of research to strengthen risk assessment for nanomaterials. The research roadmaps which were proposed in this study will be helpful to fill up the current gaps in knowledge relevant nano risk assessment.

Prioritisation of Medical Procedure for Health Technology Assessment (전문의 대상 설문조사를 이용한 보건의료 기술평가 대상 시술의 우선 순위 선정 - 이비인후과와 흉부외과를 중심으로 -)

  • 안형식;김선민;신영수;김차엽;김선미;이순형
    • Health Policy and Management
    • /
    • v.7 no.2
    • /
    • pp.46-64
    • /
    • 1997
  • Background & Objectives : Korea is face with the social need for health care technology assessment so that it is urgently needed to found principles and methodology in technology assessment in health care. As a groundwork for health care technology assessment, we tried to prioritize medical technology for assessment. Among medical technologies, procedure is somewhat difficult to assess, compared to drug or equipment. In this study, we aimed at the prioritisation of medical procedure to be assessed, in terms of efficay, safety, and adequacy. Method : For the standardized classification of medical procedure, ICD-9-CM(International Classification of Diseases 9th edition - Clinical Modification) was used. Among the list the procedures coming under otorhinolaringjology and thoracic surgery were selected by three family physicians. The list of procedure was mailed to the board certified surgeons of both disciplines, with the question asking about the necessity for assessment in terms of efficay, safety, and adequacy. Replied questionnaires were analyzed in each procedure. Results : Of 560 otorhinolaryngologist and 480 thoracic surgeon, 114 surgeons replied. Of otorhinolaryngological procedure, incision, excision, and destruction of inner ear : fenestration of inner ear : stapedectomy and its revision were the most urgent technology to assess in the aspect of safety. For adequacy, operations on Eustachian tube: fenestration of inner ear: incision, excision, and destruction of inner ear were highly ranked in necessity, and for efficary, operations on Eustachian tube; external maxillary antrotomy; fenestration of inner ear. Thoracic surgeons replied thoracic procedures, lung transplantation; heart transplantation; implantation of heart assist system [pump] are most important for evaluation in terms of safety; and heart transplantation; Lung transplantation; Implantation of heart assist system [pump] in terms of adequacy, and surgical collapse of lung [Artificia니 pnemothorax or pnuexoperitoeum]; lung transplantation; periarterial sympathectomy in terms of efficacy. As a whole, surgeons regard safety evaluation is more urgent than adequacy or efficary. In addition, otorhinolaryngological surgeons regard evaluation of their procedures more urgent than thoracic surgeons regard theirs. Conclusion : By the questionnaire to board certified physicians, we get some preliminary data for prioritisation of technologies to assess. Through the questionnaire like this, much information would be gathered for technology assessment, especially for medical procedure, if not enough. In the near future, well structured expert opinion gathering research, such as modified Delphi or nominal group technique, should be done succeedingly.

  • PDF