• 제목/요약/키워드: assay method

검색결과 2,602건 처리시간 0.029초

우유내 잔류물질 검사방법인 TTC-II법 및 Disk assay법의 비교시험 (Comparision of TTC-II and disk assay method for the detection of antibiotic residues in milk)

  • 이정아;이은미;이성해;도재철;박영구
    • 한국동물위생학회지
    • /
    • 제22권1호
    • /
    • pp.93-101
    • /
    • 1999
  • This test process on screening method for the detection of residual antibiotics in milk is simple, economic, sensitive to residual antibiotics and was given approval international organs. Thus, this study was carried out the comparison of Disk assay method and TTC-II method for sensitivity and minimum detectable range of antibiotics in raw milk. The results of this study was summarized as follows ; 1. The number of samples requested for treatment of mastitis was 198 samples. Comparison or analytical results among the methods of TTC-II, disk assay and Delve sp was that TTC-II 37 samples(18.6% ), Disk assay 125samples(63.1%), Delve SP 130 samples(65.7% ) reacted positively. Conformity rate of Delve SP and Disk assay was 70%. 2. Detectable limits of disk assay method in some antibiotics were more sensitive than those of official method(0.05-0.0025ppm in the $\beta$-lactams, 1ppm in two aminoglycoside, 0.2 ppm in one tetracycline, similar in one macrolide) 3. For sensitivity of residual sulfonamides TTC-II was much more sensitive than disk assay. Detectable limits of sulfamethazine and sulfadimethoxine were 30 to 50ppm levels. 4. The best medium preservation period is 1-2 days. 5. Concentration of brome cresol purple related to resistance for B stearothermophilus culture was 24ppm/ml. These results show that disk assay method for screening detection of antibiotics residuces in milk is worthy of use.

  • PDF

Validation of Kinetic Method for the PKA Assay in Plasma-Derived Products

  • Shin, In-Soo;Hong, Choong-Man;Koh, Hyun-Chul;Hong, Seung-Hwa
    • Biomolecules & Therapeutics
    • /
    • 제13권1호
    • /
    • pp.59-63
    • /
    • 2005
  • A kinetic assay was carried out in order to compare the ability of detection for prekallikrein activator(PKA) in plasma-derived products with that of an endpoint assay and a commercial method. Using these methods, 9 human albumin preparations were assayed and compared to each other. The coefficient of variation between the Kinetic assay and the end point assay was found within 6.6% and this result showed that two methods were highly correlative and the end point assay could act as a replacement of the kinetic assay. Another important goal of this study was to investigate the reproducibility among laboratories on the kinetic assay. A collaborative study was performed to validate the kinetic method with intra and inter assays. The coefficient of variation for the intra assay of each laboratory was less than 4% and that for between individuals in the inter assay was 4.1%. These results revealed that the kinetic assay showed good reproducibility. The contents of PKA in plasma-derived products were also determined by the kinetic assay. As a result, it was found that trace amounts of PKA were present in 32 human immunoglobulin preparations, however the average concentration of PKA in 171 albumin preparations was 5.8 IU/mL.

생체시료내 약물의 HPLC 분석법에 대한 유효성 검토방법 (Validation Process of HPLC Assay Methods of Drugs in Biological Samples)

  • 지상철;전흥원
    • Journal of Pharmaceutical Investigation
    • /
    • 제21권3호
    • /
    • pp.179-188
    • /
    • 1991
  • An HPLC assay method of a drug to be applied to the pharmacokinetic studies of the drug should be completely validated. The validation process for an HPLC assay method in a biological sample was discussed using the data obtained from the development of HPLC method for the simultaneous quantitation of verapamil and norverapamil in human serum. The validation criteria included were specificity, linearity, accuracy, precision, sensitivity, recovery, drug stability, and ruggedness of an assay method.

  • PDF

Tetrazolium salt, MTT Colorimetric Assay를 이용한 Mouse Fibroblast에 대한 화장품원료 물질의 세포독성 평가 (Cytotoxicity Evaluation of Cosmetic Materials to Mouse Fibroblast : by Tetrazolium salt, MTT Colorimetric Assay)

  • Jo, Jae- Hoon
    • 대한화장품학회지
    • /
    • 제15권1호
    • /
    • pp.37-50
    • /
    • 1989
  • The in Vitro chemosensitivity of fibroblast cell strains was determined using a semiautomated tetrazolium-based colorimetric assay(MTT assay) to 16 cosmetic materials. This assay is useful method to evaluate toxic effects of the chemicals. From assay results, we determined that the preservatives are more toxic than moisteurizers. The chemicals in the same group have a different toxicity. That is, in preservatives, Germall -115 is more toxic than Danisol -M, -p, and in surfactant sodium laurel sulfate than Myrj 52, and in moisteurizers, 1, 3-butylene glycol is more safe than the others. When the results from this assay for preservatives were compared with patch test results, good correlation was observed. Forthemore, this assay method can be used together with Patch test for the evaluation of the chemical toxicity, particularly in cosmetic field.

  • PDF

개선된 Ferron 분석 비교를 통한 Al(III) 가수분해종 특성 연구 (Comparison of the characteristics of Al(III) hydrolyzed species by improved ferron assay test)

  • 윤미형;강임석
    • 상하수도학회지
    • /
    • 제36권3호
    • /
    • pp.177-186
    • /
    • 2022
  • In this study, newly improved Ferron assay test haved on timed spectrometry was used for the determination of hyolrolytic Al species presented in PACl coagulant. The color development reagent ferron was prepared by using conventional method and two newly developed methods. Then the ferron assay test was used to compare and analyze the distribution of Al(III) hydrolyzed species presented in the prepared PACl and alum. The preparing method of reagent A required an aging period of 7 days by adding a hydroxylamine hydroxide and a 1,10-phenanthroline monohydrate reagent, whereas the preparing method of reagent B was used as a coloring agent immediately without aging time. The regression analysis between UV absorbance and Al concentrations of conventional method and newly developed method of ferron reagents in low-concentration aluminum solutions and high-concentration aluminum solutions, showed the correlation coefficients of 0.999 or higher, as showing high correlations of conventional method and newly developed method. Applying Ferron assay test, Al species in the PACls and alum were classified as Ala(monomeric Al), Alb (polymeric Al), and Alc (colloidal and precipitated Al). Distribution of Al(III) hydrolyzed species according to the preparation of ferron colorimetric reagents was similar.

고등어 표피의 미생물 오염도 신속측정을 위한 ATP Bioluminescence assay (Application of ATP Bioluminescence Assay for a Rapid Estimation of Microbial Levels in Mackerel(Scomber japonicus))

  • 오세욱;조진호;이남혁
    • 한국식품과학회지
    • /
    • 제31권5호
    • /
    • pp.1345-1348
    • /
    • 1999
  • 고등어의 저장중 표피 오염 미생물 수를 신속하게 측정하여 신선도 판정을 위한 자료로 활용하고자 ATP bioluminescence assay에 의한 측정가능성을 파악하고자 하였다. 고등어를 $1^{\circ}C$에 저장하면서 표피를 swabbing 방법에 의해 미생물을 분리하여 총균수의 변화와 ATP bioluminescence assay에 의한 RLU 값을 측정하여 상관관계를 측정하여 본 결과 0.90 이상의 regression coefficient를 나타내어 유의적인 관계가 있음을 알 수 있었다. 따라서 ATP bioluminescence assay는 고등어 표피 오염 미생물의 신속 측정 방법으로 적합함을 알 수 있었으며 이 방법을 사용하였을 경우 기존의 48시간 이상 소요되는 전통적인 plate count 방법에 비하여 전처리를 포함하여 30분 이내에 결과를 알 수 있는 매우 신속하고 정확한 측정방법임을 알 수 있었다.

  • PDF

Bioluminescent Assay of Bovine Liver Riboflavin Kinase Using a Bactreial Luciferase Coupled Reaction

  • Cho, Ki-Woong
    • Journal of Microbiology
    • /
    • 제38권2호
    • /
    • pp.74-79
    • /
    • 2000
  • For the demonstration of a novel riboflavin kinase assay method based on the bacterial bioluminescence, partially purified riboflavin kinase was prepared from bovine liver through ammonium sulfate precipitation and DEAE-cellulose ion exchange chromatography. Using bacterial luciferase from Photobacterium phosphoreum and the dithionite reduction method, and easy, safe, and fast assay method was established. The optimal temperature, pH, Km values form riboflavin and ATP of boving liver riboflavin kinase determined with this luminescence method were 35$^{\circ}C$, pH 7, 15.3${\mu}$M and 8.3.${\mu}$M, respectively. The detection limit of FMN produced by riboflavin kinase was in the range of 200 pM to 4${\mu}$M which is comparable to the HPLC-fluorescence detection method, while the detection time for each assay was less than 15 sec compared to the HPLC method which requeires at least 10 min for completion.

  • PDF

A New Assay Method for Spermidine and Spermine Synthases Using Antibody Against MTA

  • Lee, Sung-Ho;Cho, Young-Dong
    • BMB Reports
    • /
    • 제30권6호
    • /
    • pp.443-447
    • /
    • 1997
  • We have developed a novel method for assays of spermidine and spermine synthase (aminopropyltransferase) activities using antibody against 5'-deoxy-5'-methylthioadenosine (MTA). A new assay is reported here which is based on the observation that MTA is formed as a stoichiometric by-product of the spermidine and spermine synthases reactions. In order to determine MTA, a radioimmunoassay method with sensitivity and rapidity was used. (Lee and Cho, 1997). In this assay, adenine must be added in the reaction mixture, since it effectively inhibits the action of MTA phosphorylase by which MTA is metabolized. This assay is a improvement in term of sensitivity and time saving, compared to the currently used methods. It has a level of sensitivity (100 fmol) sufficient to monitor aminopropyltransferase activities in incubations containing as little as $10{\mu}g$ protein prepared from rat tissue homogenate. The results obtained showed that this method is particularly useful for cultured cells with low enzyme concentration. Moreover, this assay has the advantage which allows studies using alternative substrates (other amines). Spermidine synthase activity was high in rat liver, but low in rat kidney. The activity of spermine synthase was in most rat tissues very low as compared to that of spermidine synthase, but was high in brain.

  • PDF

E.coli ATCC 21990이 생산하는 Aminoglycoside-3'-Phosphotransferase(APH(3')) 의 Densitometric TLC Assay (Densitometric TLC Assay of Aminoglycoside-3'-Phosphotransferase (APH(3')) Produced by E. coli ATCC 21990)

  • 이정환;김계원;김기태;나규흠;김학주;양주익;김수일
    • 한국미생물·생명공학회지
    • /
    • 제19권4호
    • /
    • pp.372-379
    • /
    • 1991
  • E.coli ATCC 21990의 aminoglycoside-3'-phosphotransferase(APH(3'))의 신속하고 간편한 정량적 방법을 TLC densitometry를 이용하여 확립하였다. APH(3') 반응생산물인 3' 위치에 인산화된 kanamycin B(3'PKMB)는 silica gel plate에서 cnloroform-methanol-method-ammonia water (3:4:3) 전개용매로 반응물에서 분리되었고, 3'PKMB의 양은 ninhydrin으로 발색 후 densitometry로 측정하였다. APH(3')의 densitometric TLC assay는 좋은 정량적 결과와 재현성을 보였고, 3'-PKMB에 대한 감도는 1.56nmol이었으며 많은 시료의 분석이 한번의 실시로 가능하였다. 이 방법은 aminoglycoside 항생제의 불활화 효소 분석에 응용이 가능하리라 여겨진다.

  • PDF

Rapid Quantification of Salmonella in Seafood Using Real-Time PCR Assay

  • Kumar, Rakesh;Surendran, P.K.;Thampuran, Nirmala
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권3호
    • /
    • pp.569-573
    • /
    • 2010
  • A quantitative detection method for Salmonella in seafood was developed using a SYBR Green-based real-time PCR assay. The assay was developed using pure Salmonella DNA at different dilution levels [i.e., 1,000 to 2 genome equivalents (GE)]. The sensitivity of the real-time assay for Salmonella in seeded seafood samples was determined, and the minimum detection level was 20 CFU/g, whereas a detection level of 2 CFU/ml was obtained for pure culture in water with an efficiency of ${\geq}85%$. The real-time assay was evaluated in repeated experiments with seeded seafood samples and the regression coefficient ($R^2$) values were calculated. The performance of the real-time assay was further assessed with naturally contaminated seafood samples, where 4 out of 9 seafood samples tested positive for Salmonella and harbored cells <100 GE/g, which were not detected by direct plating on Salmonella Chromagar media. Thus, the method developed here will be useful for the rapid quantification of Salmonella in seafood, as the assay can be completed within 2-3 h. In addition, with the ability to detect a low number of Salmonella cells in seafood, this proposed method can be used to generate quantitative data on Salmonella in seafood, facilitating the implementation of control measures for Salmonella contamination in seafood at harvest and post-harvest levels.