• Title/Summary/Keyword: aseptic processing

Search Result 18, Processing Time 0.026 seconds

Plastic Packaging Industry of Thailand (태국 플라스틱 포장산업 현황에 관한 고찰)

  • Park, Hyung Woo;Kim, Sang Hee;Koh, Ha Young;Vanee, C.;Lerpong, J.
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.22 no.3
    • /
    • pp.103-106
    • /
    • 2016
  • This survey was performed by Kasetsart University Department of Packaging and Materials Technology on Food Packaging Industry in Thailand, was to conduct on the status and trends of food packaging industry to obtain the information on the plastic of packaging materials in food packaging in Thailand. The survey conducted by field visits, questionnaires, interviews and personal communication as well as published data from different sources. The ration of plastic consumption among the industries, packaging is showed 49%, textile 15% and construction 11% respectively. Numbers of company among packaging industry, film processing company is 503, injection molding is 231, blow molding is 216. Production volume of PP, HDPE, LLDPE and LDPE is 1,950 mil. ton, 1,920 mil. ton, 1,150 mil. ton and 685 mil. ton, respectively. Import of plastic 16,668 mil. baht and export is 33,778 mil. baht. Plastic consumption is plastic bottle and flexible pouch, mainly being used in beverage industry. The past decade as it has been replaced by flexible pouches and aseptic cartons in Thailand.

Effects of Heat Treatment on the Nutritional Quality of Milk III. Effect of Heat Treatment on Killing Pathogens in Milk (우유의 열처리가 우유품질과 영양가에 미치는 영향: III. 우유 열처리에 의한 병원균 사멸효과)

  • Moon, Yong-II;Jung, Ji Yun;Oh, Sejong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.35 no.2
    • /
    • pp.121-133
    • /
    • 2017
  • A small amount of milk is sold as 'untreated' or raw in the US; the two most commonly used heat-treatments for milk sold in retail markets are pasteurization (LTLT, low-temperature long time; HTST, high-temperature short time) and sterilization (UHT, ultra-high temperature). These treatments extend the shelf life of milk. The main purpose of heat treatment is to reduce pathogenic and perishable microbial populations, inactivate enzymes, and minimize chemical reactions and physical changes. Milk UHT processing combined with aseptic packaging has been introduced to produce shelf-stable products with less chemical damage than sterile milk in containers. Two basic principles of UHT treatment distinguish this method from in-container sterilization. First, for the same germicidal effect, HTST treatments (as in UHT) use less chemicals than cold-long treatment (as in in-container sterilization). This is because Q10, the relative change in the reaction rate with a temperature change of $10^{\circ}C$, is lower than the chemical change during bacterial killing. Based on Q10 values of 3 and 10, the chemical change at $145^{\circ}C$ for the same germicidal effect is only 2.7% at $115^{\circ}C$. The second principle is that the need to inactivate thermophilic bacterial spores (Bacillus cereus and Clostridium perfringens, etc.) determines the minimum time and temperature, while determining the maximum time and temperature at which undesirable chemical changes such as undesirable flavors, color changes, and vitamin breakdown should be minimized.

Sterilization of Gochujang Sauce with Continuous Ohmic Hea (연속 옴가열 장치를 이용한 고추장 소스의 살균)

  • Choi, Jun-Bong;Cho, Won-Il;Jung, Jung-Yoon;Chung, Myong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.474-479
    • /
    • 2015
  • In this study, five different Gochujang (a traditional Korean sauce prepared using fermented red pepper paste) sauces were heated at $100^{\circ}C$ for 5 min using a continuous ohmic heating system. Ohmic heating yielded greater reduction in microbial counts (90-95% reduction) than did conventional heating (65-75% reduction). The sterilization effect of the continuous ohmic heater increased with increasing sample flow rate and decreasing Reynolds number inside the pipe. Low-viscosity samples had higher electrical conductivity and were better suited for ohmic heating than were high-viscosity samples. The color and texture were also satisfactorily maintained after ohmic heating. Compared with conventional heating, ohmic heating provided rapid and uniform heating, which is more suitable for aseptic thermal processing of viscous foods.

New Product Marketing Strategy: The Case of Binggrae's 'a Café la'

  • Yeu, Minsun;Lee, Doo-Hee;Kim, Sang Yong;Yoo, Shijin
    • Asia Marketing Journal
    • /
    • v.14 no.3
    • /
    • pp.169-184
    • /
    • 2012
  • All firms require new stimulus to spurt growth. Therefore it is necessary to successfully develop new products and to employ appropriate marketing practices for the new products to enter and settle in the market. Binggrae, a Korean company that specializes in dairy and processed dairy products, introduced a ready-to-drink (RTD) coffee product, 'a Café la' to expand its business into the coffee market in 2008. Binggrae was a latecomer in the RTD coffee market but a Café la has shown an impressive average sales growth rate of 115% as of 2011 since the launch. Moreover, it is a steady bestselling coffee brand among the Polyethylene terephthalate (PET)bottle category. Binggrae found potential and opportunity in the growing coffee market and made efforts to develop a new product that can be differentiated from the existing products. The result was PET bottle coffee, which was more portable and convenient to drink than coffee products offered in cups or cans. PET bottle coffee is produced through the patented Aseptic Filing System, thus the original coffee flavor stays fresh when combined with milk and has a longer shelf life than coffee products in cups. Moreover, as the taste of coffee consumers has become more sophisticated, Binggrae developed a premium product by differentiating the product processing method and by using higher-quality Arabica beans. After launching the new product, the company also employed a well-designed communication strategy. First, Binggrae was able to confirm the level of market demand and market potential for the product by employing BTL (Below the Line) marketing strategies through the consumers' word-of-mouth. Afterwards, the company invested its resources for a full-scale ATL (Above the Line) marketing campaign. Later a Café la's TV commercial effectively portrayed the product's characteristics, and succeeded in raising consumer awareness of the product. As a result, a Café la has become the bestselling brand in the PET bottle coffee market. The successful new product marketing strategy of Binggrae'sa Café la offers many valuable implications for companies planning to launch new products in the future.

  • PDF

Effect of Prunus mume Extract on Shelf-life of Fermented Dairy Product (매실추출물이 발효유제품의 Shelf-life에 미치는 영향)

  • Choi Sung-Gil;Oh Byung-Tae;Park Woo-Po;Lee Seung-Cheol;Cho Sung-Hwan
    • Food Science and Preservation
    • /
    • v.13 no.3
    • /
    • pp.304-309
    • /
    • 2006
  • In order to examine the antimicrobial effect on dairy processing facilities and products, Prunus mume extinct (PME) was applied to the pilot plant system of dairy industry and yogurt, PME showed thermal and pH stability in the wide spectrum of temperature ($40{\sim}150^{\circ}C$) and pH ($4{\sim}10$) and remarkable antimicrobial activities against dairy spoilage microorganisms. As the result of aseptic treatment of dairy processing facilities with PME microbial colony including coliform bacteria was not detected canpore to those detected in the control. In the level of PME concentration which inhibit the growth of putrefactive microorganisms we could produce yogurt with good scores of sensory evaluation.

Evaluation of Lethality by Chemical Marker (Chemical Marker를 이용한 살균도 예측)

  • Choi, Yang-Mun;Kim, Hie-Joon
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 1997
  • The rate constants and activation energies for formation of two chemical markers, M-1 and M-2 at sterilization temperatures were determined in a meatball system. Destruction rates for bacterial spores were also determined. The rate constants for M-1 and M-2 formation at $121^{\circ}C$ were 0.03 and 0.28 Abs/min, respectively. The activation energies for M-1 and M-2 were 27.9 and 24.6 Cal/mol. M-2 was formed faster than M-1 and reached a maximum and decreased. M-1 formation continued up to 30 min at $121^{\circ}C$ and 10 min at $131^{\circ}C$, which makes M-1 a more useful chemical marker for high $F_0$ values. The D-values for spores (B. stearothermophilus ATCC 12980) at 111, 114.4, 117.7 and $121^{\circ}C$ were 7.5, 4.5, 1.9 and 0.58 respectively. At temperatures between 111 and $121^{\circ}C$, there was a liner correlation between destruction of the spores and the M-1 formation. It was difficult to get accurate D-value at $126^{\circ}C\;and\;131^{\circ}C$, because almost all spores were dead before temperature at the center of the meatball reached $126^{\circ}C$. These data suggest that the chemical marker should be used to evaluate overprocessing as well as microbial lethality in aseptic processing.

  • PDF

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.