• Title/Summary/Keyword: asbestos analysis

Search Result 98, Processing Time 0.024 seconds

Investigation and Risk Assessment of Asbestos-Containing Materials used in Buildings (건축물에 사용된 석면함유물질(ACMs)의 조사 및 위해성 평가)

  • Kim, Hong-Kwan;Chon, Young Woo;Roh, Young Man;Hong, Seung-Han;Kim, Chi-Nyon;Lee, Ik-Mo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Objectives: The objectives of this study are to research the usage characteristics of asbestos-containing building materials and to conduct exposure risk assessment by applying no. 2016-230 "Methods of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. Methods: One hundred buildings located in the Seoul and Gyeonggi-Incheon area were chosen, with 29 in Seoul, 20 in Incheon, and 51 in Gyeonggi-do Province. The year of construction was divided between three buildings in the 1970s, 11 buildings in the 1980s, 42 buildings in the 1990s, and 44 buildings in the 2000s. The bulk samples were analyzed by using a polarizing microscope after a pre-process using a stereomicroscope in a hood with an HEPA filter. This study defined ACMs(asbestos-containing materials) as asbestos when the content percentage was over 1% in the analysis result. Methods and standards of risk assessment of asbestos-containing building materials were conducted by refering to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. The risk of exposure to ACMs was rated by a score based on three categories(high, middle, low risk of asbestos exposure). Results: In this study, 30 of the 100 buildings and 36 of the 416 bulk samples(8.6%) were found to have had asbestos. Asbestos was detected at a high rate, in 18 out of 42, in buildings constructed in the 1990s and at the lowest rate(7 out of 44) for buildings constructed in the 2000s. As a result of the evaluation according to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" of the Ministry of Environment, the risk assessment level of two asbestos-containing building materials was found to be "Medium", and 28 buildings materials were found to be at the "Low" level. Conclusion: As asbestos is regulated by the government, it is required to conduct active management and implemention by introducing methods of risk assessment of asbestos exposure that are supported by data from various situations. In the case of buildings owned by individuals, building owners should be aware of the risk of exposure to asbestos.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

Development of Technology for Recovering Valuable Metals in Detoxified Waste Asbestos-Containing Waste (무해화된 폐석면에 함유된 유가금속 회수 기술 개발)

  • Kim, Dong Nyeon;Yang, Dong Hyeon;Kim, Seok Chan
    • Applied Chemistry for Engineering
    • /
    • v.31 no.4
    • /
    • pp.438-442
    • /
    • 2020
  • Studies on the recovery conditions and optimization process for valuable metal recovery through chemical treatment from detoxified asbestos-containing waste composed of calcium silicate, larnite, merwinite, and akermanite were conducted. The main components, Si, Ca, and Mg, of detoxified asbestos-containing waste (DACW) were separated and recovered in the form of SiO2, CaSO4, and Mg(OH)2 compounds, respectively. Each separated component was confirmed through X-ray diffraction (XRD) and inductively coupled plasma spectrometer (ICP) analysis. The recovery conditions for each component were first treating them with an acid to separate SiO2 and subsequently with H2SO4 to recover Ca in the form of sulfate, CaSO4. The remaining Mg was recovered by precipitation with Mg(OH)2 under strong basic conditions. This study suggested that it is possible to convert existing treatment process of asbestos waste by landfill through recovering the components into a resource-recycling green technology.

A Study on Characteristics of Airborne Asbestos Concentrations Using PCM and TEM in Life Environment Surroundings of Seoul (서울지역 생활환경주변의 공기 중 석면분포 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jihui;Oh, Seokryul;Shin, Jinho;Eom, Seokwon;Chae, Youngzoo;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.9
    • /
    • pp.613-623
    • /
    • 2013
  • This study is purposed to evaluate the airborne asbestos concentrations in life environment surroundings in Seoul. In study, we investigated airborne asbestos concentrations in thirteen subway stations, four monitoring networks and each vicinity roadside, six stream surroundings, four tunnels quarterly and we also investigated relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks and time-based airborne asbestos concentration variability for two typical monitoring networks, two subway stations transferred and used by lots of people through Phase Contrast Microscopy (PCM) and Transmission Electron Microscopy (TEM). The airborne asbestos concentrations by PCM for 4 objects of study were less than the detection limit (7 fiber/$mm^2$) in 111 (50%) out of 223 samples. The highest concentration was 0.0130 f/cc. But additional TEM analysis result for samples exceeding the guideline value for indoor air quality (0.01 f/cc) proposed by the Ministry of Environment (Korea), no asbestos was detected. Similarly TEM analysis result for 124 samples, no asbestos was detected. The average airborne asbestos concentrations by PCM in subway stations, monitoring networks, streams and tunnels were $0.0041{\pm}0.0027$ f/cc, $0.0015{\pm}0.0011$ f/cc, $0.0024{\pm}0.0012$ f/cc and $0.0016{\pm}0.0020$ f/cc. All objects of study were satisfied with the guideline value for indoor air quality. The relationship between the airborne asbestos concentrations and ambient temperature in monitoring networks was generally positive correlation (r = 0.660). The higher ambient temperature was and the more transient population was, the airborne asbestos concentrations by time for two subway stations were increased. While the airborne asbestos concentrations for two monitoring networks showed no variation pattern according to time.

The Effect of Pleural Thickening on the Impairment of Pulmonary Function in Asbestos Exposed Workers (석면취급 근로자에서 늑막비후가 폐기능에 미치는 영향)

  • Kim, Jee-Won;Ahn, Hyeong-Sook;Kim, Kyung-Ah;Lim, Young;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.923-933
    • /
    • 1995
  • Background: Pleural abnormality is the the most common respiratory change caused by asbestos dust inhalation and also develop other asbestos related disease after cessation of asbestos exposure. So we conducted epidemiologic study to investigate if the pleural abnormality is associated with pulmonary function change and what factors are influenced on pulmonary function impairment. Methods: Two hundred and twenty two asbestos workers from 9 industries using asbestos in Korea were selected to measure the concentration of sectional asbestos fiber. Ouestionnaire, chest X-ray, PFT were also performed. All the data were analyzed by student t-test and chi-square test using SAS. Regressional analysis was performed to evaluate important factors, for example smoking, exposure concentration, period and the existence of pleural thickening, affecting to the change of pulmonary function. Results: 1) All nine industries except two, airborn asbestos fiber concentration was less than an average permissible concentration. PFT was performed on 222 workers and the percentage of male was 88.3%, their mean age was $41{\pm}9$ years old, and the duration of asbestos exposure was $10.6{\pm}7.8$ yrs. 2) The chest X-ray showed normal(89.19%), pulmonary Tb(inactive)(2.7%), pleral thickening (7.66%), suspected reticulonodular shadow(0.9%). 3) The mean values of height, smoking status, concentration of asbestos fiberwere not different between the subjects with pleural thickening and others, but age, cumulative pack-years, the duration of asbestos exposure were higher in subjects with pleural thickening. 4) All the PFT indices were lower in the subjects with pleural thickening than in the subjects without pleural thickening. 5) Simple regression analysis showed there was a significant correlation between $FEF_{75}$ which is sensitive in small airway obstruction and cumulative smoking pack-years, the duration of asbestos exposure and the concentration of asbestos fiber. 6) Multiple regression analysis showed all the pulmonary function indices were decreased as the increase of cumulative smoking pack-years and especially in the indices those are sensitive in small airway obstruction. Pleural thickening was associated with reduction in FVC, $FEV_1$, PEFR and $FEF_{25}$. Conclusion: The more concentration of asbestos fiber and the more duration of asbestos exposure, the greater reduction in $FEF_{50}$, $FEF_{75}$. Therefore PFT was important in the evaluation of early detection for small airway obstruction. Furthermore pleural thickening without asbesto-related parenchymal lung disease is associated with reduction in pulmonary function.

  • PDF

Asbestos Exposure among Mitering Workers

  • Phanprasit, Wantanee;Sujirarat, Dusit;Musigapong, Pirutchada;Sripaiboonkij, Penpatra;Chaikittiporn, Chalermchai
    • Safety and Health at Work
    • /
    • v.3 no.3
    • /
    • pp.235-240
    • /
    • 2012
  • The objectives are to compare the airborne asbestos concentrations resulted from mitering of abestos cement roof sheets by a high-speed motor and a hand saw, and to monitor whether other workers near the test sites are vulnerable to the fibers exceeding the occupational exposure limit. Four test cases were carried out and altogether 7 personal and 4 area air samples were collected. The NIOSH method 7400 was employed for the air samplings and analysis. Using the phase contrast microscopy, fiber counting was conducted under Rule A. The study showed that the fiber concentration medians for personal air samples gathered from the two tools were 4.11 fibers/cc (ranged: 1.33-12.41 fibers/cc) and 0.13 fibers/cc (ranged: 0.01-5.00 fibers/cc) respectively. The median for the area samples was 0.59 fibers/cc (ranged: 0.14-3.32 fibers/cc). Comparing each study case, the concentration level caused by the high-speed motor saw was more than twice that of the hand saw. According to the area samples, the workers nearby the test site are at risk from high exposure to asbestos.

Study on the Detoxification of Asbestos-Containing Wastes (ACW) Using SiC Plate (SiC 플레이트를 이용한 석면 함유 폐기물의 무해화 연구)

  • Hong, Myung Hwan;Choi, Hyeok Mok;Joo, So Young;Lee, Chan Gi;Yoon, Jin-Ho
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.35-42
    • /
    • 2020
  • Even asbestos-containing waste (ACW) are highly harmful to humans, it continues being produced due to the massive disposal of asbestos-containing products. A development of asbestos detoxification and recycling technologies is required. Heat treatment using microwave is the most efficient method for ACW detoxification. However, microwave heat treatment method has the limitation that asbestos does not absorb microwave at room temperature. That is why, in this study, ACW was detoxified by microwave heat treatment adding the ACW between SiC plates, which are inorganic heating elements that absorb microwaves at room temperature. In order to improove the heat transfer, ACW was crushed and pulverized and then heated using microwave. Microwave heat treatment temperature and time variables were adjusted to investigate the detoxification properties according to heat treatment conditions. After heat treatment, treated ACW was analyzed for detoxification properties through crystal structure and microstructure analysis using X-ray diffraction (XRD) and scanning electron microscopy (SEM). Microwave heat treatment method using SiC plate can be heated up to the target temperature within a short time. Finally, complete asbestos detoxification was confirmed from the crystal structure and the microstructure when the microwave heat treatment was performed at 1,200℃ for at over 60 minutes and at 1,300℃ for at over 10 minutes.

Analysis of Mortality from Asbestos-Related Diseases in Brazil Using Multiple Health Information Systems, 1996-2017

  • Algranti, Eduardo;Santana, Vilma S.;Campos, Felipe;Salvi, Leonardo;Saito, Cezar A.;Cavalcante, Franciana;Correa-Filho, Heleno R.
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.302-307
    • /
    • 2022
  • Background: In Brazil, asbestos was intensively used from the 1960s until its ban in 2017. Mesothelioma, asbestosis, and pleural plaques are typical asbestos-related diseases (ARD-T). To create an ARD-T national database, death records from 1996-2017 were retrieved from several health information systems (HIS). Methods: All national HIS containing coded diagnoses (ICD-10) and death information were obtained. Linkage was performed to create a single database of ARD-T death records, either as underlying or contributory causes, in adults aged 30 years and older. Results: A total of 3,057 ARD-T death records were found, 2,405 (76.4%) of which being malignant mesotheliomas (MM). Pleural MM (n = 1,006; 41.8%) and unspecified MM (n = 792; 32.9%) prevailed. Male to female MM ratio (M:F) was 1.4:1, and higher ratios were found for non-malignant ARD-T: 3.5:1 for asbestosis and 2.4:1 for pleural plaques. Male crude annual mesothelioma mortality (CMmm ×1,000,000) was 0.98 in 1996 and 2.26 in 2017, a 131.1% increment, while for females it was 1.04 and 1.25, a 20.2% increase, correspondingly. The small number of deaths with asbestosis and pleural plaques records precluded conclusive interpretations. Conclusions: Even with the linkage of several HIS, ARD-T in death records remained in low numbers. MM mortality in men was higher and showed a rapid increase and, along with non-malignant ARD-T, higher M:F ratios suggested a predominant pattern of work-related exposure. The monitoring of workplace and environmental asbestos exposure needs to be improved, as well as the workers surveillance, following the recent Brazilian ban.

Estimation of Factors Influencing Airborne Fiber Concentrations through an Observation Survey of Asbestos-containing Materials in Buildings (석면함유 건축물의 관찰조사를 통한 실내공기 중 섬유 농도 변화 요인 추정)

  • Lee, Seungchul;Kim, Boowook;Yi, Gwang Yong;Shin, Yong Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.174-183
    • /
    • 2015
  • Objectives: The objective of this study is the estimation of factors influencing airborne fiber concentrations by means of an observation survey of asbestos-containing materials in buildings. Methods: Forty-five samples were collected from four commercial buildings by NIOSH Method 7400 and classified according to current condition, potential activity, construction year, and operations and maintenance(O&M). Results: Airborne fiber concentrations by current condition(classified as good, fair and poor) were significantly different(p<0.05). Concentrations by potential activity were significantly different among groups(p<0.05), and those from the low activity group were higher than those from the middle activity group. Based on construction year, airborne fiber concentrations from the decade of the 1990's were higher than those from the 1960's. When O&M status was considered, airborne fiber concentrations from 1960's buildings were lower than those buildings not operated and maintained(p<0.01), because dust generation was influenced by O&M status. It was found that airborne fiber concentrations were related to current condition and potential activity via regression analysis, but the coefficient of determination was low. Also, correlation analysis showed that the higher the potential activity, the more current condition is worsened, but the relationship was not significant(r=-0.455, p>0.05). Conclusions: Airborne fiber concentrations in asbestos-containing buildings had weak relationships with current condition and potential activity.