• Title/Summary/Keyword: artificial lung

Search Result 89, Processing Time 0.028 seconds

Evaluation of Sulfite Solution to Predict Oxygen Transfer Rates in Artificial Lung (인공폐에서의 산소전달 속도를 예측하기 위한 아황산용액의 평가)

  • Lee, S.C.;Kim, K.B.;Jheong, G.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.237-238
    • /
    • 1998
  • The kinetics of sulfite oxidation must be fast and the concentration of sulfite must be low to emulate oxygen uptake by blood. The kinetics were studied yielding a first order rate constant in sulfile, zero order in oxygen. Limitations of the technique were evaluated using the experimental rate constant and an adaptation of Lightfoot's approximation, while the reaction of hemoglobin is reversible and essentially instantaneous, that for sulfite is irreversible and finite. Thus if the approach to saturations not monotonic or if the mass transfer resistance is significantly lowered, e. g. when blood film thicknesses are thinner than a few hundred microns, deviations may occur.

  • PDF

Gas Permeability and Blood Compatibility in Polydimethylsiloxane Polypropylene Combined Membrane (Polydimethylsiloxane 가공 Polypropylene막에서의 기체투과 및 혈액적합성)

  • Kim, K.B.;Lee, S.C.;Jheong, G.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.233-234
    • /
    • 1998
  • The purpose of this paper is the evaluation of a permeability and blood compatibility for silicone/polypropylene combined membrane. Despite the overall good performances of polypropylene membrane, its long-lasting usage for artificial lung has been limited by serum leakage. In order to overcome this problem, we have newly fabricated polydimethylsiloxane(silicone)/polypropylene combined membrane(SPCM). SPCM has been proved to be serum leakage free in hours experimental. It has shown good long-lasting gas transfer and durability features.

  • PDF

Annual report of thoracic and cardiovascular surgery in Korea [II] (흉부외과 진료통계( II ) -1992년-)

  • Sun, Kyung;Kwak, Young-Tae;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 1993
  • This is the result of the annual statistic analysis of thoracic and cardiovascular surgical cases in 1992 Korea. Overall 17, 520 cases of surgery [11, 732 cases of thoracic surgery by 54 institutes / 5, 788 cases of cardiovascular surgery by 48 institutes] were done. 1. Tumor [N=2, 532] : Lung was the most frequently involved organ by tumor [54.9%],and the remainders were mediastinum [16.2%] / esophagus [14.8%] / chest wall [11.7%] / tracheobronchus [1.3%] / pleura [1.1%] in order. Of 1, 082 cases of primary lung cancer surgery,the frequency of cell type was squamous [62.6%] / adeno [21.6%] / small cell [7.1%] / large cell [2.7%]. Of 411 cases of mediastinal tumor surgery,the frequency of cell type was neurogenic [28.8%] / thymoma [27.6%] / teratoma [17.7%] / congenital cystic [17.2%]. Of 376 cases of esophageal tumor surgery,primary cancer were the most [85.4%]. 2. Infection [N=3, 157] : Pleura was the most frequently involved organ [59.0%],and the remainders were lung [31.3%] / chest wall [8.6%] / mediastinum [1.1%] in order. 3. Miscellaneous [N=6, 043] : Lung and pleural disease esp. pneumothorax [85.1%] was the most frequent surgical indication. The remainders were chest wall anomaly [3.4%] / benign esophageal disease [3.4%] / diaphragmatic pathology [2.4%] / myasthenia [1.4%] in order. Of 85 cases of thymectomy for myasthenia gravis,thymoma was noted in 58.8%. 1. Congenital heart disease [N=3, 363] : The ratio of noncyanotic to cyanotic heart disease was 3:1. Of 2, 516 cases of noncyanotic heart disease,the frequency of disease entity was VSD [44.1%] / ASD [26.0%] / PDA [19.4%] / PS [3.3%],and that of 847 cases of cyanotic heart disease was TOF [29.4%] / ECD [15.6%] / TGA [9.7%] / DORV [7.6%]. Overall mortalities were 2.1% in noncyanotic and 12.2% in cyanotic heart surgery. 2. Acquired heart disease [N=1, 929] : Of 1, 422 cases of valvular surgery,single mitral pathology was the most frequent candidate [48.0%],and total 1, 574 prosthetic valves which were mainly mechanical [95.6%] were used. Of 376 cases of coronary surgery,triple vessel was the most [35.9%],and the frequency of bypassing grafts was great saphenous vein [52.9%] / internal mammary artery [44.7%] / artificial vessel [2.4%]. Overall mortalities were 3.4% in valvular and 4.5% in coronary surgery. 3. Pericardium,Cardiac tumor,Arrhythmia,Aortic aneurysm,Assist device,and Pacemaker : There were no specific changes compared to previous survey1]. This nation-wide inquiry will be continued and reported annually by KTCS Society.

  • PDF

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

Evaluation of Deep-Learning Feature Based COVID-19 Classifier in Various Neural Network (코로나바이러스 감염증19 데이터베이스에 기반을 둔 인공신경망 모델의 특성 평가)

  • Hong, Jun-Yong;Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.397-404
    • /
    • 2020
  • Coronavirus disease(COVID-19) is highly infectious disease that directly affects the lungs. To observe the clinical findings from these lungs, the Chest Radiography(CXR) can be used in a fast manner. However, the diagnostic performance via CXR needs to be improved, since the identifying these findings are highly time-consuming and prone to human error. Therefore, Artificial Intelligence(AI) based tool may be useful to aid the diagnosis of COVID-19 via CXR. In this study, we explored various Deep learning(DL) approach to classify COVID-19, other viral pneumonia and normal. For the original dataset and lung-segmented dataset, the pre-trained AlexNet, SqueezeNet, ResNet18, DenseNet201 were transfer-trained and validated for 3 class - COVID-19, viral pneumonia, normal. In the results, AlexNet showed the highest mean accuracy of 99.15±2.69% and fastest training time of 1.61±0.56 min among 4 pre-trained neural networks. In this study, we demonstrated the performance of 4 pre-trained neural networks in COVID-19 diagnosis with CXR images. Further, we plotted the class activation map(CAM) of each network and demonstrated that the lung-segmentation pre-processing improve the performance of COVID-19 classifier with CXR images by excluding background features.

Clinical experience of open heart surgery -70 cases- (개심술 70예의 임상경험)

  • 조광현
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.644-662
    • /
    • 1986
  • Seventy cases of open heart surgery were performed in the department of Thoracic and Cardiovascular Surgery, Pusan Paik Hospital, Inje College, from Oct. 1985 to Oct. 1986. And the results were summarized as follows. 1. Among the 70 cases, there were 48 cases of congenital heart anomalies and 22 cases of acquired rheumatic valvular heart diseases. Age range of the congenital patients was 7 months to 31 years with the mean age of 10 years, and the acquired patients was 18 to 62 years with the mean age of 40 years. 2. The heart-lung machine used for cardiopulmonary bypass was Sarns 7000, 5-head roller pump, and the number and type of oxygenators were 5 of membrane type and 65 of bubble type. For all cases GIK [glucose-insulin-potassium] solution was used as cardioplegic solution for myocardial protection during operation. 3. Among the 48 congenital anomalies, there were 12 cases of ASD group, 29 of VSD group, 3 of ECD, 3 of TOF and one of PDA + MR, and to all of which the appropriate radical operations were applied. 4. Among the 22 acquired valvular diseases, there were 11 cases of mitral valve diseases [MS; 4, MSr; 3, MRs; 4], 3 cases of aortic valve diseases [AR:1, ARs;1, ASr;1], 4 cases of double valve diseases [MRs+TR; 3, MRs+ARs; 1] and 4 cases of triple valve diseases [MSr+ASr+TR; 3, MSr+Ar+TR; 1]. To all the diseased mitral and aortic valves, artificial valve replacement was applied except one [As], in which valve plication was applied. And to all the diseased tricuspid valve, DeVega annuloplasty was applied. 5. The number of replaced artificial valves were 29 in 25 patients [congenital; 3, acquire; 22]. In MVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 15 of tissue valves [Carpentier-Edward valve; 11, lonescu-Shiley valve; 4] were used. In AVR, 6 of mechanical valves [St. Jude Medical valve; 6] and 2 of tissue valves [Carpentier-Edward valve; 2] were used. 6. Postoperative complications were occurred in 12 cases. Among them 11 cases were recovered with intensive cares, but one patient [VSD + Fistula of Valsalva sinus] was expired with low cardiac out put syndrome.

  • PDF

Assessment and Analysis of Fidelity and Diversity for GAN-based Medical Image Generative Model (GAN 기반 의료영상 생성 모델에 대한 품질 및 다양성 평가 및 분석)

  • Jang, Yoojin;Yoo, Jaejun;Hong, Helen
    • Journal of the Korea Computer Graphics Society
    • /
    • v.28 no.2
    • /
    • pp.11-19
    • /
    • 2022
  • Recently, various researches on medical image generation have been suggested, and it becomes crucial to accurately evaluate the quality and diversity of the generated medical images. For this purpose, the expert's visual turing test, feature distribution visualization, and quantitative evaluation through IS and FID are evaluated. However, there are few methods for quantitatively evaluating medical images in terms of fidelity and diversity. In this paper, images are generated by learning a chest CT dataset of non-small cell lung cancer patients through DCGAN and PGGAN generative models, and the performance of the two generative models are evaluated in terms of fidelity and diversity. The performance is quantitatively evaluated through IS and FID, which are one-dimensional score-based evaluation methods, and Precision and Recall, Improved Precision and Recall, which are two-dimensional score-based evaluation methods, and the characteristics and limitations of each evaluation method are also analyzed in medical imaging.

Comparison of Two Methods of Recruiting the Acutely Injured Lung (급성 폐손상에서 폐를 Recruit시키는 방법간의 비교 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Kim, Ho-Choel;Young, Lim-Si;Chung, Man-Pyo;Han, Jeong-Ho;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.500-512
    • /
    • 2000
  • Background : To evaluate the efficacy of two methods of obtaining lung recruitment to reduce ventilator-induced lung injury(VILI). Methods : Fifteen New-Zealand white rabbits were ventilated in the pressure-controlled mode while maintaining constant tidal volume(10 ml/kg) and fixed respiration rate. Lung injury was induced by repeated saline lavage (PaO2<100 mmHg), and the pressure-volume curve was drawn to obtain Pflex. The animals were then randomly assigned to three groups and ventilated for 4 hours. In the control group(n=5), positive end-expiratory pressure(PEEP) less than that of Pflex by 3 mmHg was applied throughout the study. In the recruitment maneuver(RM) group(n=5), RM(CPAP of 22.5 mmHg, for 45 seconds) was performed every 15 minutes in addition to PEEP level less than Pflex by 3 mmHg This phrase is unclear. In the Pflex group, PEEP of Pflex was given without RM. Gas exchange, lung mechanics, and hemodynamics parameters as well as pathology were examined. Results : 1) Both the control and RM groups showed decreasing tendency in PaO2 with time. There was significantly decreased PaO2 at 4 hr compared to Ihr(p<0.05). But in the Pflex group, PaO2 did not decrease with time(p<0.05 vs other groups at 3, 4 hr). PaCO2 did not show significant difference among the three groups. 2) There was no significant difference in static compliance and plateau pressure. Mean blood pressure and heart rate also did not show any significant difference among the three groups. 3) The pathologic exam showed significantly less neutrophil infiltration in the Pflex group than in the control group(p<0.05). There was borderline significant difference in hyaline membrane score among the groups (p= 0.0532). Conclusion : Although recruitment maneuver of the injured lung may be important in decreasing VILI, it alone may not be sufficient to minimize VILI.

  • PDF

Gas Transfer and Hemolysis Characteristics of a New Type Intravenous Lung Assist Device (혈관 내 신형 폐보조장치의 기체전달 및 용혈 특성)

  • 김기범;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.121-126
    • /
    • 2003
  • The purpose of this work was to assess and quantify whether the beneficial effects in long-term gas exchange at exciting frequency were obtained at different frequencies as well and then to develop a vibrating intravascular lung assist device(VIVLAD), for Patients suffering from acute respiratory distress syndrome(ARDS) or chronic respiratory problems. We investigate the optimal condition of the frequency band excited with new vibrator at state of limit hemolysis when blood hemolysis came to through a membrane vibration action. The experimental design and procedures were given for a device used to assess the effectiveness of membrane vibrations. Quantitative experimental measurements were performed to evaluate the performance of the device . and to identify membrane vibration dependence on blood hemolysis. We developed an analytical solution for the hydrodynamics of flow through a bundle of sinusoidally vibrated hollow fibers that is used to provide some insight into how wall vibrations might enhance the performance of the VIVLAD. In the result, it was measured that the effect of various excited frequencies in gas transfer rate and hemolysis from the maximum gas transfer rate at no vibration when the maximum gas transfer rates showed at module type 6, module type 6 consisted of 675 hollow fiber membranes The maximum oxygen transfer rate was caused by the occurrence of maximum amplitude and transfer of vibration to hollow fiber membranes when it was excited by the frequency band of 7Hz at each blood flow rate. because this frequency became the End mode resonance frequency of the flexible in blood flow. Also, when module type 6 was excited at an excited frequency of 7Hz. blood hemolysis was low. Therefore, we decided that the limit of hemolysis frequency is 7Hz . because maximum amplitude occurred at this frequency.

In vitro cultivation for development of Ascaris suum from the decoated and embryonated eggs(second-stage larva) (시험관내에서 돼지회충(Ascaris suum) 함자충란(L2)의 인공배양)

  • Jee, Cha-ho;Park, Seung-jun
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.1
    • /
    • pp.107-117
    • /
    • 1998
  • The cultivation for development of Ascaris suum from the second-stage larvae($L_2$) embryonated egg and the third-stage of rat-derived larvae($L_3$) recovered from lung of rats were performed to use the screening test of anthelmintics in vitro. The preparations of larvae for cultivation were that the artificially-hatched $L_2$ incubated the embryonated eggs of Ascaris suum in 0.1% formalin solution at $25^{\circ}C$ for 28 days and the rat-derived larvae($L_3$) recovered from the lung of rat infected with the embryonated eggs of Ascaris suum on 7 days after infection(DAI). The cultivation for development of Ascaris suum from the embryonated eggs($L_2$) and the rat-derived larvae($L_3$) for 14 days in RPMI medium 1640(with 5% bovine calf serum) were as follows : 1. The sizes of the liberated larvae($L_2$) which were artificially hatched from embryonated eggs with glass beads(diameter 5mm) were $190{\sim}250{\mu}m$ on 1 days in culture(DIC). The second-stage larvae were molted into third-stage larvae(early $L_3$; $250{\sim}300{\mu}m$) and the features of these larvae were first observed such as cephalic cuticle, esophageal lumen and anus etc. on 5 DIC and the sizes of late third-stage larvae were $250{\sim}450{\mu}m$ on 10 DIC. The sizes of early fourth-stage larvae($L_4$) were $500{\sim}700{\mu}m$ and the features of these larvae were more pronounced in internal organs on 15 DIC. 2. The sizes of third-stage larvae($L_3$) recovered from the lung of rats were $1,340{\sim}1,370{\mu}m$ and the feartures of cephalic cuticle, esophageal lumen, intestine, rectum, anus were visualized by inverted microscope on 1 DIC. The fourth-stage larva($L_4$) completed by third ecdysis were recognizable and sizes of early fourth-stage larvae were developed as $1,400{\sim}2,200{\mu}m$ on 5 DIC. The sizes of middle fourth-stage of larva were $1,900{\sim}2,300{\mu}m$ and the thickened epithelial rectum was observed on 10 DIC. The rectum and anus of late fourth-stage larva($L_4$ $2,500{\sim}3,200{\mu}m$) had developed completely in RPMI medium 1640 on 15 DIC.

  • PDF