• Title/Summary/Keyword: artificial joints

Search Result 83, Processing Time 0.024 seconds

Effect of Artificial Leg Length Discrepancy on 3D Hip Joint Moments during Gait in Healthy Individuals (건강한 성인에서 인위적 다리길이 차이가 보행 중 3차원 엉덩관절 모멘트에 미치는 효과)

  • Jo, Min-Ji;Kim, Dong-Hyun;Han, Dong-Wook;Choi, Eun-Jin;Kim, Ye-Seul;Kim, Yong-Wook
    • PNF and Movement
    • /
    • v.17 no.3
    • /
    • pp.391-399
    • /
    • 2019
  • Purpose: This study investigated the three-dimensional moment values of the hip joint for subjects with artificial leg length alterations and subjects with unaltered leg lengths. Methods: Forty-two healthy adults (8 men, 34 women) participated in this study. The selected subjects were able to walk normally, had less than a 1 cm leg length discrepancy, and were instructed to wear shoes that fit their feet. The study participants performed 8 dynamic gait trails to measure the hip joint moment using a three-dimensional motion analysis system. Kinetic and dynamic three-dimensional gait analysis data were collected from infrared cameras, and a force plate was used to standardize the weight of each subject. Results: There were significant correlations between the differences in the leg length discrepancy during right extension, right flexion, right internal rotation, and left extension in hip joint moments (p<0.05). There were significant correlations between the differences in shoe conditions during left extension, right flexion, right extension, and right internal rotation in the hip moments (p<0.05). Conclusion: This study suggests that a leg length discrepancy can affect hip joint moment, which may further exacerbate musculoskeletal disorders, such as osteoarthritis in lower extremity joints. Therefore, further studies should be conducted to verify the impact of clinical interventions on differences in hip joint moment values to correct leg length discrepancies and prevent osteoarthritis in lower extremity joints.

A Kinetic Analysis of the Lower Extremity on the Normal and Abnormal Specificity of Walking on Stair for Twenties (이십대 청년의 정상 및 비정상 계단보행특성에 따른 하지의 운동역학적 분석)

  • Kim, Young-Ji;Lee, Young-Shin;Kim, Chang-Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.6
    • /
    • pp.391-396
    • /
    • 2011
  • Gait is walking attitude and indicating state. The body's gait is a good mix in the center of body mechanics and exercises to wake up gently at the same time switch is a pass which is complicated at legs various joints. The shifting action what swing phase and stance phase rhythmic movement of body. One from piece moves with different dot. Especially plain walking and stair walking as a vehicle has been used frequently. Characteristics of the stair walking while the balanced the horizontal and vertical movement. Stair walking often takes place in everyday. It requires large range more than walking at plain in the moment and joint range of gait motion. And consistently applied to joints and various types of loads at legs joint may involve joint disorders. In this study, spastic cerebral palsy existing artificial limbs for disabled people when developing calibration equinus deformity patients induce muscle pain when walking on stairs independently, to reduce the research. Comparing the characteristics of the walking up the stairs for analysis patellofemoral joint pain as a result it is to provide engineering data.

Mirror Finishing of Co-Cr-Mo Alloy by Ultrasonic Elliptical Vibration Cutting Method (초음파타원진동절삭가공법에 의한 Co-Cr-Mo 합금의 경면가공)

  • Song, Young-Chan;Tanaka, Kenichi;Moriwaki, Toshinmichi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.56-62
    • /
    • 2008
  • The biocompatibility and the fatigue strength of Co-Cr-Mo alloy are excellent, so it is used well for the material of artificial joints. The head of artificial joint needs mirror surface for reduction of abrasive resistance. Mirror finishing of Co-Cr-Mo alloy with geometrically defined single crystal diamond cutting tools is handicapped by micro chipping of tool edge. In general, it is said that the micro chipping of diamond tool is caused by work hardening of Co-Cr-Mo alloy for the cut. In the present research, mirror finishing of Co-Cr-Mo alloy by applying ultrasonic elliptical vibration cutting was carried out. The experimental results show that the micro chipping of diamond tool was suppressed and the tool wear was remarkably reduced as compared with the ordinary diamond cutting without elliptical vibration motion. It was confirmed that the good mirror surface of maximum surface roughness of 25 nmP-V was obtained for the cutting length of about 14 m. It is expected that mirror finishing of Co-Cr-Mo alloy can be achieved by applying ultrasonic elliptical vibration cutting practically.

Effect of ${\gamma}$-Ray Irradiation on Surface Oxidation of Ultra High Molecular Weight Polyethylene/Zirconia Composite Prepared by in situ Ziegler-Natta Polymerization

  • Kwak, Soon-Jong;Noh, Dong-Il;Chun, Heung-Jae;Lim, Youn-Mook;Nho, Young-Chang;Jang, Ju-Woong;Shim, Young-Bock
    • Macromolecular Research
    • /
    • v.17 no.8
    • /
    • pp.603-608
    • /
    • 2009
  • Novel ultra-high molecular weight polyethylene (UHMWPE)/zirconia composites were previously prepared by the in situ polymerization of ethylene using a Ti-based Ziegler-Natta catalyst supported on to the surface of zirconia, as a bearing material for artificial joints. Tribological tests revealed that a uniform dispersion of zirconia in UHMWPE markedly increased the wear resistance. The effects of zirconia content on the oxidation behavior of the ${\gamma}$-ray-treated UHMWPE/zirconia composite surfaces were examined. The oxidation index that estimates the oxidation degree as the content of total carbonyl compounds was monitored using Fourier transform infrared spectroscopy-attenuated total reflectance. The changes in the surface composition due to the oxidation were confirmed by electron spectroscopy for chemical analysis. The extent of oxidation decreased with increasing zirconia content, which was attributed to the increased crystallinity as well as the decreased polymer portion of the UHMWPE/zirconia composites.

Functional Motion Analysis of Wrist Joints (손목관절의 기능적 운동 특성의 동작 분석)

  • Han Jung Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.543-548
    • /
    • 2003
  • Injuries of wrist in upper extremity is common onset in industrialized world. The development of joint arthroplasty and mechanical joint is area of research for biomechanical engineer and surgeon for a decade. Therefore. the knowledge of characteristic of joint motion is essential to develop the artificial wrist joint. In this study. the joint motions of wrist required for activities of daily living (ADLs). including personal hygiene and care. and general home activity were measured using flexible electrogoniometer. Total of 25 different daily activities were separated into four groups and tested on 15 subjects who did not show any abnormality of their joint functions. The maximum functional range of motion required for ADLs were obtained and standardized for analysis and comparison. Also. a least functional range of motion for ADLs were investigated. Results revealed that any significant differences were not found in least functional range of motion between left and right wrist to perform ADLs. However. a significant difference was found in different ADLs. Therefore. least range of motion obtained in this study can be used as basic data to design artificial joint and set a goal for surgeon to achieve appropriate treatment from patients.

Effect of Heat Treatment on Mechanical Properties of Cross-Linked Ultra-High Molecular Weight Polyethylene Used for Artificial Joint Liner (인공관절 라이너용 가교된 초고분자량폴리에틸렌(UHMWPE)의 열처리 조건에 따른 기계적 특성 변화)

  • Kim, Hyun-Mook;Kim, Dong-Hoon;Gu, Ja-Uk;Choi, Nak-Sam;Kim, Sung-Kon
    • Composites Research
    • /
    • v.22 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • The mechanical characteristics of gamma-ray irradiated UHMWPE specimens were investigated under various heat treatment conditions. The heat treatment was performed in the range of annealing and remelting temperatures. The annealing treatment below the temperature of $130^{\circ}C$ hardly induced changes in the tensile strength, the strain at the failure and the hardness. However the remelting treatment above $140^{\circ}C$ deteriorated those mechanical properties. It was shown in an FTIR analysis that the annealing treatment caused some oxidation of free radicals created by the pretreatment of the irradiation. These quantitative data represented by the behavior of mechanical properties might be used as basic informations for the design and analysis of various artificial joints.

Predicted the behavior of the femur according to the loading condition using FEM (유한요소해석을 이용한 하중조건에 따른 대퇴골의 거동예측)

  • Song, Seung-Youp;Choi, Seong Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.3-9
    • /
    • 2013
  • Falling related injuries are categorized as the most serious and common medical problems experienced by the elderly. Hip joint fracture, one of the most serious consequences of falling in the elderly, occurs in only about 1% of falling. In this study, according to the loading conditions, the analysis is the behavior of the femur. The CT images using the commercial program "Mimics" the bones of three-dimensional CAD data generated, and we will analyze the results of finite element analysis. The boundary conditions on the basis of existing research has been simplified. In this paper, the whole femur was assumed to be isotropic linear elastic material. Predicted the behavior of the femur according to the loading condition, it can be help the development of high-precision artificial bones and joints can be treated with surgery and will be able to perform efficiently.

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

Development of FACS-based Android Head for Emotional Expressions (감정표현을 위한 FACS 기반의 안드로이드 헤드의 개발)

  • Choi, Dongwoon;Lee, Duk-Yeon;Lee, Dong-Wook
    • Journal of Broadcast Engineering
    • /
    • v.25 no.4
    • /
    • pp.537-544
    • /
    • 2020
  • This paper proposes the creation of an android robot head based on the facial action coding system(FACS), and the generation of emotional expressions by FACS. The term android robot refers to robots with human-like appearance. These robots have artificial skin and muscles. To make the expression of emotions, the location and number of artificial muscles had to be determined. Therefore, it was necessary to anatomically analyze the motions of the human face by FACS. In FACS, expressions are composed of action units(AUs), which work as the basis of determining the location and number of artificial muscles in the robots. The android head developed in this study had servo motors and wires, which corresponded to 30 artificial muscles. Moreover, the android head was equipped with artificial skin in order to make the facial expressions. Spherical joints and springs were used to develop micro-eyeball structures, and the arrangement of the 30 servo motors was based on the efficient design of wire routing. The developed android head had 30-DOFs and could express 13 basic emotions. The recognition rate of these basic emotional expressions was evaluated at an exhibition by spectators.

Evaluation of image quality for metal artifact using protocol parameters in the MRI (자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가)

  • Lee, Su-Hyun;Kim, Do-Gyoung;Kim, Yo-Han;Yeum, Hyei-Jeong;Lee, Heon-Jun;Lim, Ju-Yeon;Choi, Woo-Jeon;Kim, Dong-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.582-585
    • /
    • 2015
  • In the aging society, TKRA is steadily increased because of joint diseases. Artificial joint used in TKRA generates metal artifacts in the MRI. Metal artifact may affect diagnosis. In study, We are going to minimize the effect of metal artifact to improve the value of diagnosis by changing the sequence and the type of artificial joint(Co-Cr, Ni-Ti). 1.5T AVANTO, plastic containers and each of the artificial joint (Normal, Co-Cr, NiTi) were used. After the artificial joints fixed in a paper cup was inserted in a plastic container of cylindrical, Signal intensity was measured. To obtain strong and uniform signal intensity, the plastic container was filled with water. We changed Sequences(T1 TSE, T2 TSE, PD TSE) and obtained an Axial image. After excepting the maximum and minimum values, We calculated the average of SNR, CNR and PSNR. Consequently, The SNR, CNR value of PD TSE are measured higher than these of T1 TSE, T2 TSE and The PSNR of Co-Cr is higher than this of Ni-Ti. The SNR of Co-Cr is similar to the SNR of normal comparing this of Ni-Ti. As a result, Using sequence of PD Tse and Co-Cr alloy is considered to be useful.

  • PDF