• Title/Summary/Keyword: artificial joint

Search Result 274, Processing Time 0.029 seconds

Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint (가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.378-385
    • /
    • 1995
  • The ultrasonic non-destructive testing uses the directivity of the ultrasonic pulse wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is closely related to determination of probe arrangement, testing sensitivity, scanning pitch and defect location and characterization. The paper measured the directivity of shear wave, which reflected from artificial defect located in weld metal zone in butt welded joint similar model made of pyrex glass by using visualization method. 2 MHz and 4 MHz angle probes were used to measure the directivity of reflection wave at the artificial defect. The directivity of shear waves reflected from the defect was different according to the probe position and the shape of butt welded joint. The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. The angle of reflection wave became equal to angle of incidence as increase of the height of excess metal.

  • PDF

A Simulation Study on the Stress Distribution of the Transplanting Part of Artificial Knee Joint due to Elastic Modulus (탄성계수에 따른 무릎 인공관절 이식 부품의 응력분포에 관한 시뮬레이션 연구)

  • Lee, J.H.;Hwang, G.W.;Cho, J.U.;Cheon, Seong S.
    • Composites Research
    • /
    • v.28 no.3
    • /
    • pp.89-93
    • /
    • 2015
  • This study analyzes the transplanting parts used as the graft of artificial knee joint. The low elastic titanium alloy is applied to clear up the stress shield effect. The simulation analysis is carried about the stress distribution of the transplanting parts. The correlation with frame is inferred and investigated through the equivalent stress distribution of titanium alloy due to elastic modulus. The stress of the transplanting parts decreases as the elastic modulus decreases at the first time. It decreases greatly near the stress of 46 GPa and increases again. Because the stress happened at the transplanting parts decreases, more stress is applied on the frame. This phenomenon is the stress shield effect. The result of this study can be thought to be necessary to develop the safe design of composite material.

Structural Analysis and Design of Artificial Hip Joint by Using Finite Element Method (유한요소법을 이용한 인공 고관절의 역학적 거동 해석 및 설계)

  • 정재연;황운봉;하성규
    • Composites Research
    • /
    • v.12 no.5
    • /
    • pp.98-109
    • /
    • 1999
  • An investigation has been performed to develop a nonlinear finire element method for the analysis of the long-term behavior of an artificial hip joint. The three dimensional multi-layered brick element is used to analyze the design performances of hip prodtheses with various materials and the thick laminated composite hip prostheses with various layup sequences. The used element can accommodate the varying material properties of the element and allow the ply-drop-off along the eleement edge. The nonlinear finite element analysis program has been verified by the comparison with the exact solution of the bean problem subjected to uniaxial loading. By using the program, the density changes and strength ratios of artificial hip joint are calculated according to the hip prosthesis materials and the layers of composite hip prosthesis. The numerical results are easily applied to evaluate design performances of a hip prosthesis, and decrease the difficulty and time of hip prosthesis design.

  • PDF

A Study on Pk(Probability of Kill) Calculation Method of the Direct Fire Weapon System using ANN (인공신경망을 적용한 직사화기 무기체계의 살상확률(Pk) 산출방법론 연구)

  • Jang, Young Cheon;Han, Hyun Jin;Lee, Ki Teak;Song, Mi Jin;Lee, Hwi Yeong;Kim, Jong Heon
    • Journal of the Korea Society for Simulation
    • /
    • v.28 no.1
    • /
    • pp.99-107
    • /
    • 2019
  • Until now it has had the limitation of the target in the US JMEM to calculate the Pk with the existing method by our study. In this study, we focused on deriving a method to calculate the Pk of the actual targets except JMEM targets using ANN. We study the initial predictive model of ANN(Artificial Neural Network) from the targets data of the specification and the vulnerable area in the US JMEM(Joint Munitions Effectiveness Manuals), and calculate the actual targets vulnerable area by using this method. Finally, we propose a method to calculate the Pk by applying those data to the existing method of us.

Current Diagnostic Methods for Periprosthetic Joint Infection

  • Lee, Jiyoung;Park, Heechul;Bae, Jinyoung;Hyun, Hyanglan;Kim, Sunghyun
    • Biomedical Science Letters
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Total joint arthroplasty is a successful joint replacement treatment that improves joint function and overall quality of life and provides pain relief. However, the prevalence of periprosthetic joint infection (PJI) has become prevalent with the rise in the incidence of arthroplasty surgery. PJI occurs rarely following arthroplasty however presents with serious complications, including high morbidity. The identification of causative microorganisms is essential for the treatment of PJI. Managing PJI requires complex treatment strategies, including long-term antibacterial treatment, and significant medical costs can be incurred. The American Academy of Orthopedic Surgeons, the Centers for Disease Control and Prevention, and Surgical Care Improvement Project guidelines recommend that prophylactic antibiotics such as first-generation cephalosporins be infused completely 1 hour before surgical incision. However, these preventative antibiotics are very limited, therefore risk factors must be identified to diagnosis and treat patients effectively. Moreover, determining antimicrobial susceptibility during artificial joint surgery and choosing the most appropriate treatment strategy following an accurate diagnosis of microbial infections are essential. In the present review, we describe the management, including the etiology, diagnosis, and classification of PJI, and approaches to its diagnosis using the available novel molecular diagnostic methods.

A Study for Joint Freezing in Concrete Pavement (콘크리트포장의 줄눈의 잠김에 대한 연구)

  • Lee, Seung-Woo
    • International Journal of Highway Engineering
    • /
    • v.3 no.1 s.7
    • /
    • pp.165-176
    • /
    • 2001
  • Joints in jointed concrete Pavement are designed to control against randomly occurred cracks within slabs, which may be caused by temperature or moisture variation. The advantage of these artificial cracks (joints) over naturally occurred cracks are easy access of protections, such as installation of joint seal and load transfer mechanism. The potential benefits of joint seals are to prevent infiltration of surface water through the joint into underlying soil and intrusion of incompressible materials (debris, fine size aggregate) in to the joint, which may prevent weakening of underlying soils and spallings due to excessive compressive stress, respectively. For the adequate design of joint seal, horizontal variation of joint widths (horizontal joint movements) are essential inputs. Based on long-term in-situ joint movement data of sixteen jointed concrete pavement sections in Long Term Performance Pavement Seasonal Monitoring Program (LTPP SMP), it was indicated that considerable Portion of joints showed no horizontal movements with change in temperature. This Phenomenon is called 'Joint Freezing'. Possible cause for joint freezing is that designed penetrated cracks do not occur at a joint. In this study, a model for the prediction of the ratio of freezing joints in a particular pavement sections is proposed. In addition, possible effects of joint freezing against pavement performance are addressed.

  • PDF

Trajectory tracking controls for a robot manipulator with artificial muscles (인공 고무 근육을 이용한 로보트 메니퓨레이터의 선형 궤도 추적 제어)

  • ;Watanabe, Keigo;Nakamura, Masatoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.642-646
    • /
    • 1992
  • Trajectory tracking control problems are described for a two-link robot manipulator with artificial rubber muscle actuators. Under the assumption that the so-called independent joint control is applied to the control system, the dynamic model for each link is identified as a linear second-order system with time-lag by the step response. Two control laws such as the feedforward and the computed torque control methods, are experimentally applied for controlling the circular trajectory of an actual robot manipulator.

  • PDF

Evaluation of image quality for metal artifact using protocol parameters in the MRI (자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가)

  • Lee, Su-Hyun;Kim, Do-Gyoung;Kim, Yo-Han;Yeum, Hyei-Jeong;Lee, Heon-Jun;Lim, Ju-Yeon;Choi, Woo-Jeon;Kim, Dong-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.582-585
    • /
    • 2015
  • In the aging society, TKRA is steadily increased because of joint diseases. Artificial joint used in TKRA generates metal artifacts in the MRI. Metal artifact may affect diagnosis. In study, We are going to minimize the effect of metal artifact to improve the value of diagnosis by changing the sequence and the type of artificial joint(Co-Cr, Ni-Ti). 1.5T AVANTO, plastic containers and each of the artificial joint (Normal, Co-Cr, NiTi) were used. After the artificial joints fixed in a paper cup was inserted in a plastic container of cylindrical, Signal intensity was measured. To obtain strong and uniform signal intensity, the plastic container was filled with water. We changed Sequences(T1 TSE, T2 TSE, PD TSE) and obtained an Axial image. After excepting the maximum and minimum values, We calculated the average of SNR, CNR and PSNR. Consequently, The SNR, CNR value of PD TSE are measured higher than these of T1 TSE, T2 TSE and The PSNR of Co-Cr is higher than this of Ni-Ti. The SNR of Co-Cr is similar to the SNR of normal comparing this of Ni-Ti. As a result, Using sequence of PD Tse and Co-Cr alloy is considered to be useful.

  • PDF

Multi-resolution Fusion Network for Human Pose Estimation in Low-resolution Images

  • Kim, Boeun;Choo, YeonSeung;Jeong, Hea In;Kim, Chung-Il;Shin, Saim;Kim, Jungho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2328-2344
    • /
    • 2022
  • 2D human pose estimation still faces difficulty in low-resolution images. Most existing top-down approaches scale up the target human bonding box images to the large size and insert the scaled image into the network. Due to up-sampling, artifacts occur in the low-resolution target images, and the degraded images adversely affect the accurate estimation of the joint positions. To address this issue, we propose a multi-resolution input feature fusion network for human pose estimation. Specifically, the bounding box image of the target human is rescaled to multiple input images of various sizes, and the features extracted from the multiple images are fused in the network. Moreover, we introduce a guiding channel which induces the multi-resolution input features to alternatively affect the network according to the resolution of the target image. We conduct experiments on MS COCO dataset which is a representative dataset for 2D human pose estimation, where our method achieves superior performance compared to the strong baseline HRNet and the previous state-of-the-art methods.

Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT (SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가)

  • Kim, Sang Gyu;Kim, Jung Yul;Park, Min Soo;Jo, Seung Hyun;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.3-7
    • /
    • 2014
  • Purpose SPECT/CT scan to be performed attenuation correction on the basis of CT induce an overestimation of the site due to the beam hardening artifact by metal cover and reduce the images quality. Therefore, this study using a phantom that has been inserted artificial hip joint investigated that effect on the SPECT/CT image causing by metal artifact for varying the parameters of the Attenuation Map. Materials and Methods Siemens Symbia T16 SPECT/CT equipment was used. Artificial hip joint was inserted to SPECT/PET phantom, 17 mm sphere of Bright Streak area in CT image was filled with Tc-99m so that the radiation activity was 8 times compared to background. And then Hot and Background was measured in varying Wide Beam Coefficient on Attenuation Map and RBR (Region to Background Ratio) of Metal and Non-Metal was calculated and analyzed depending on the presence or absence of the hip joint. Results It tended to hot count of Non-Metal and Metal to increase as the value of the manual mode is increased, hot count ratio with the group of both manual mode 0.5 and 0.4 is the best match. Also, in automatic mode, the ratio of RBRNon-Metal and RBRMetal was 1.135, statistically significant difference was not observed in the manual mode 0.5 and 0.4. Conclusion In the automatic mode of Wide Beam Coefficient in attenuation correction map, it was found that it is over-correction by 13.52%, it was possible to minimize the over-correction by the artifact in 0.5 and 0.4 of manual mode. Further studies should be performed in order to apply to a patient with the help of this and it is considered possible to reduce the over-correction by the metal artifact of an artificial hip joint for Hip-Resurfacing Arthroplasty patients, and to improve the diagnostic performance.

  • PDF