• 제목/요약/키워드: artificial cross

검색결과 383건 처리시간 0.032초

생체판의 제작 및 실험 (A Study on the Manufacture of the Artificial Cardiac Tissue Valve)

  • 김형묵;송요준;손광현
    • Journal of Chest Surgery
    • /
    • 제12권4호
    • /
    • pp.383-394
    • /
    • 1979
  • Treatment of valvular heart disease with valve replacement has been one of the most popular procedures in cardiac surgery recently. Although, first effort was directed toward the prosthetic valve, it soon became popular that bioprosthesis, the valvular xenograft, was prefered in the majority cases. Valvular xenograft has some superiority to the artificial prosthetic valve in some points of thromboembolism and hemolytic anemia, and it also has some inferiority of durability, immunologic reaction and resistance to Infection. Tremendous efforts were made to cover the inferiority with several methods of collection, preservation, and valve mounting of the porcine valve or pericardium of the calf, and also with surgical technique of the valvular xenograft replacement. Auther has collected 320 porcine aortic valves immediately after slaughter, and aortic cusps were coapted with cotton balls in the Valsalva sinuses to protect valve deformity after immersion in the Hanks' solution, and oxidation, cross-linking and reduction procedures were completed after the proposal of Carpentier in 1972. Well preserved aortic valves were suture mounted in the hand-made tissue valve frame of 19, 21, and 23 mm J.d., and also in the prosthetic vascular segment of 19 mm Ld. with 4-0 nylon sutures after careful trimming of the aortic valves. Completed valves were evaluated with bacteriologic culture, pressure tolerance test with tolerane gauge, valve durability test in the saline glycerine mixed solution with tolerance test machine in the speed of 300 rpm, and again with pathologic changes to obtain following results: 1. Bacteriologic culture of the valve tissue in five different preservation method for two weeks revealed excellent and satisfactory result in view of sterilization including 0.65% glutaraldehyde preservation group for one week bacteriologic culture except one tissue with Citobacter freundii in 75% ethanol preserved group. 2. Pressure tolerance test was done with an apparatus composed of V-connected manometer and pressure applicator. Tolerable limit of pressure was recorded when central leaking jet of saline was observed. Average pressure tolerated in each group was 168 mmHg in glutaraldehyde, 128 mmHg in formaldehyde, 92 mmHg in Dakin's solution, 48 mmHg in ethylene oxide gas, and 26 mmHg in ethanol preserved group in relation to the control group of Ringer's 90 mmHg respectively. 3. Prolonged durability test was performed in the group of frame mounted xenograft tissue valve with 300 up-and-down motion tolerance test machine/min. There were no specific valve deformity or wearing in both 19, 21, and 23 mm valves at the end of 3 months (actually 15 months), and another 3 months durability test revealed minimal valve leakage during pressure tolerance test due to contraction deformity of the non-coronary cusp at the end of 6 months (actually 30 months) in the largest 23 mm group. 4. Histopathologic observation was focussed in three view points, endothelial cell lining, collagen and elastic fiber destructions in each preservation methods and long durable valvular tolerance test group. Endothel ial cell lining and collagen fiber were well preserved in the glutaraldehyde and formaldehyde treated group with minimal destruction of elastic fiber. In long durable tolerance test group revealed complete destruction of the endothelial cell lining with minimal destruction of the collagen and elastic fiber in 3 month and 6 month group in relation to the time and severity. In conclusion, porcine xenograft treated after the proposal of Carpentier in 1972 and preserved in the glutaraldehyde solution was the best method of collection, preservation and valve mounting. Pressure tolerance and valve motion tolerance test, also, revealed most satisfactory results in the glutaraldehyde preserved group.

  • PDF

사회연결망분석과 인공신경망을 이용한 추천시스템 성능 예측 (Predicting the Performance of Recommender Systems through Social Network Analysis and Artificial Neural Network)

  • 조윤호;김인환
    • 지능정보연구
    • /
    • 제16권4호
    • /
    • pp.159-172
    • /
    • 2010
  • 협업필터링 추천은 다양한 분야에서 활용되고 있지만 트랜잭션 데이터의 성격에 따라 추천 성능에 현저한 차이를 보이고 있다. 기존 연구에서는 이러한 추천 성능의 차이가 나타나는 이유에 대한 설명을 구체적으로 제시하지 못하고 있고 이에 따라 추천 성능의 예측 또한 연구된 바가 없다. 본 연구는 사회네트워크분석과 인공신경망 모형을 이용하여 협업필터링 추천시스템의 성능을 예측하고자 한다. 본 연구의 목적을 달성하기 위해 국내 백화점의 트랜잭션 데이터를 기반으로 형성되는 고객간 사회 네트워크의 구조적 지표를 측정한 후 이를 기반으로 인공신경망 모형을 구축하고 검증한다. 본 연구는 협업필터링 추천 성능을 예측할 수 있는 새로운 모형을 제시하였다는 점에서 그 의의가 있으며 이를 통해 기업들의 협업필터링 추천시스템 도입에 대한 의사결정에 도움을 줄 수 있을 것으로 기대된다.

머신러닝을 이용한 터널발파설계 자동화를 위한 기초연구 (A fundamental study on the automation of tunnel blasting design using a machine learning model)

  • 김양균;이제겸;이승원
    • 한국터널지하공간학회 논문집
    • /
    • 제24권5호
    • /
    • pp.431-449
    • /
    • 2022
  • 지금까지 국내에서는 수 많은 터널들이 완공되어 오면서 시공에서뿐 아니라 설계에서도 다양한 경험과 기술이 지속적으로 축적되어 왔다. 따라서 이제는 매우 복잡한 지질조건 또는 특수한 터널구조가 아니라면 일반적인 터널설계작업은 설계 항목에 따라 기존 유사 설계사례를 수정 또는 보완하는 것만으로도 충분한 경우도 적지 않다. 특히 터널발파설계의 경우, 실제 터널시공시 현장에서 시험발파를 통해 시공을 위한 발파설계를 추가로 수행하는 것이 일반적이라는 것을 감안할때, 설계단계에서 수행하는 발파설계는 예비설계 성격을 지니고 있어 기존의 유사 설계사례를 참고하는 것도 타당하다고 사료된다. 한편 최근 4차산업혁명시대에 들어서면서 전 산업분야에 걸쳐 그 활용도가 급증하고 있는 인공지능은 터널 및 발파분야에서도 다양하게 활용되고 있지만, 발파터널의 경우 발파진동 및 암반분류 등의 예측 분야에서 주로 활용되고 있을 뿐 터널발파패턴 설계에 활용된 사례는 많지 않다. 따라서 본 연구에서는 터널발파설계를 인공지능의 한 분야인 머신러닝 모델을 이용하여 자동화하기 위한 시도를 하였다. 이를 위하여 25개 학습용 터널설계 자료 및 2개의 시험용 설계자료에서 4가지의 입력데이터(지보패턴, 도로유형, 상반 및 하반 단면적) 및 16개의 출력데이터(심발공 종류, 비장약량, 천공수, 각 발파공 그룹별 공간격과 저항선 등)를 발췌하였다. 이를 기반으로 3가지 머신러닝 모델, 즉, XGBoost, ANN, SVM 모델을 시험한 결과 XGBoost모델이 상대적으로 최상의 결과를 나타내었다. 또한 이를 이용하여 실제 발파설계 상황을 가정하여 발파패턴을 제안하도록 한 결과 일부 항목에서 보완이 필요하긴 하지만 일반적 설계와 유사한 결과를 나타내었다. 본 연구가 기초연구 성격이어서 전체 발파설계를 완벽하게 수행하기는 아직 부족하지만, 향후 충분한 발파설계데이터를 확보하고 세부적인 처리과정을 보완하여 실용적인 활용이 가능하도록 추가 연구를 수행할 계획이다.

빅데이터와 AI를 활용한 의료영상 정보 시스템 발전 방향에 대한 연구 (A Study on the Development Direction of Medical Image Information System Using Big Data and AI)

  • 유세종;한성수;전미향;한만석
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권9호
    • /
    • pp.317-322
    • /
    • 2022
  • 정보기술의 급격한 발달은 의료 환경에서도 많은 변화를 가져오고 있다. 특히 빅데이터와 인공지능(AI)을 활용한 의료영상 정보 시스템의 빠른 변화를 견인하고 있다. 전자의무기록(EMR)과 의료영상저장전송시스템(PACS)으로 구성된 처방전달시스템(OCS)은 의료 환경을 아날로그에서 디지털로 빠르게 바꾸어 놓았다. PACS는 여러 솔루션과 결합하여 호환, 보안, 효율성, 자동화 등 새로운 발전 방향을 보여주고 있다. 그 중, 영상의 질적 개선을 할 수 있는 빅데이터를 활용한 인공지능(AI)과의 결합이 활발히 진행되고 있다. 특히 딥러닝 기술을 활용하여 의료 영상 판독을 보조할 수 있는 시스템인 AI PACS가 대학과 산업체의 협력으로 개발되어 병원에서 활용되고 있다. 이처럼 의료 환경에서 의료영상 정보 시스템의 빠른 변화에 맞추어 의료시장의 구조적인 변화와 이에 대처할 수 있는 의료정책의 변화도 필요하다. 한편, 의료영상정보는 디지털 의료영상 전송 장치에서 생성되는 DICOM 방식을 기본으로 하고, 생성하는 방법의 차이에 따라 Volume 영상, 단면 영상인 2차원적 영상으로 구분된다. 또한, 최근 많은 의료기관에서는 스마트 병원 서비스를 내세우며 차세대 통합 의료정보시스템의 도입을 서두르고 있다. 차세대 통합 의료정보시스템은 EMR을 바탕으로 전자동의서, AI와 빅데이터를 활용한 정밀의료, 외부기관 등을 통합한 솔루션으로 구축하며, 이를 바탕으로 환자 정보 DB 구축과 데이터의 표준화를 통한 의료 빅데이터 기반의 의학 연구를 목적으로 한다. 우리나라의 의료영상 정보 시스템은 앞선 IT 기술력과 정부의 정책에 힘입어 세계적인 수준에 있으며, 특히 PACS 관련 프로그램은 의료 영상정보 기술에서 세계로 수출을 하고 있는 한 분야이다. 본 연구에서는 빅데이터를 활용한 의료영상 정보 시스템의 분석과 함께 의료영상 정보 시스템이 국내에 도입되게 된 역사적 배경을 바탕으로 현재의 흐름을 파악하고 나아가 미래의 발전 방향을 예측하였다. 향후, 20여 년 동안 축적된 DICOM 빅데이터를 기반으로 AI, 딥러닝 알고리즘을 활용하여 영상 판독률을 높일 수 있는 연구를 진행하고자 한다.

덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용 (Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation )

  • 이주형;곽임종;조창빈;최지영;박광연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.17-24
    • /
    • 2023
  • 이 논문은 total flux leakage (TFL) 방법을 이용해 외부텐던을 비파괴검사 하는 솔레노이드 형태의 센서의 측정 신호를 후처리하는 방법을 소개한다. 기존에 개발된 TFL 솔레노이드 센서는 1차 코일과 2차 코일로 이루어져 1차 코일에 정현파 형태의 교류를 입력하면 2차 코일에 그 미분에 비례하는 신호가 측정된다. 이때 진폭은 텐던의 단면에 비례하므로 파단 및 부식 여부를 확인할 수 있다. 따라서 TFL센서의 측정신호에서 진폭정보를 추출 하는 것이 중요한데 기존에는 단순히 극댓값을 모아 진폭정보를 취득했다. 하지만 이 방법을 사용하면 측정빈도가 크게 낮아져 추가적인 신호처리 및 인공지능 적용에 많은 제약이 생긴다. 이 논문은 높은 측정빈도를 가진 진폭정보를 추출하기 위해 진폭복조를 응용해 진폭정보를 획득하는 방법을 제시한다. 진폭복조를 이용해 진폭정보를 취득하면 측정빈도를 원시신호와 동일한 수준으로 유지할 수 있다. 이 방법은 TFL센서의 1차 코일 입력 주파수 선택과 센서를 외부텐던에 적용하는 속도 등에 제약을 없애주어 개발 방향에 많은 자유도를 부여한다. 또한 높은 측정빈도를 유지하므로 추가적인 신호처리나 인공지능 등을 활용 하는데 유리함을 제공한다. 제안된 방법은 실내실험을 통해 검증 되었으며 기존 방법과 비교해 어떤 장점이 있는지 분석했다. 제시된 예제의 경우 진폭복조를 사용한 방법이 기존 방법에 비해 100배 높은 측정빈도를 제공 하는 것을 확인 할 수 있었다. 주어진 상황과 구체적인 장비 설정에 따라 차이가 있겠지만 대부분의 경우 진폭복조를 사용해 진폭정보를 추출하면 기존 방법 대비 만족할만한 결과를 얻을 수 있을 것이다.

선천성 심장수술 후 지연 흉골 봉합시 사망률 및 종격동 감염률 그리고 위험인자 (Risk Factor, Mortality and Infection Rate of Mediastinum After Delayed Sternal Closure in Congenital Heart Surgery Patients)

  • 이진구;박한기;홍유선;박영환;조범구
    • Journal of Chest Surgery
    • /
    • 제35권7호
    • /
    • pp.517-522
    • /
    • 2002
  • 목적: 선천성 심장질환에서 수술 직후 심장부종이나 혈역학적 불안정 상태시 흉골을 열어놓고 나중에 봉합을 하는 지연 흉골 봉합이 도움이 될 수 있다. 이러한 경우에 있어서 사망률과 종격동 감염률 그리고 그 위험 인자를 알고자 한다. 대상 및 방법: 1994년 1월부터 2001년 5월까지 연세대학교 의과대학 심장혈관병원에서 선천성 심장수술 후 지연 흉골 봉합을 시행한 40명의 환자를 대상으로 이들에 있어서 사망률과 종격동 감염률를 조사하고 이에 영향을 미치는 인자로 수술시간, 인공심폐기 사용시간(bypass time), 대동맥 결찰시간(ACC time), 수술 후 흉골을 열어놓고 있었던 시간, 인공호흡기를 하고 있었던 기간을 조사하였다. 종격동 감염은 종격동에서 균이 동정된 경우로 정의 하였다. 결과: 흉골을 열고 나온 이유로는 혈역학적 불안정이 36명으로 가장 많았고 출혈과 흉골 봉합시 도관(conduit)이 눌려 열고 나온 경우가 각각 2명이었다. 이들의 수술시 나이는 $14.4{\pm}33.4$개월(2일-12년 2개월)이었고 출혈과 흉골 봉합시 도관이 눌려 흉골을 열고 나왔던 4명 모두 나머지에 비해 나이가 많았다. 봉합까지의 평균 기간은 $4.5{\pm}3.4$일(1~20일)이었다. 사망률은 25%(10/40)였으며 종격동 감염률은 수술후 10일 이전에 감염이 원인이 아닌 사망을 보인 3명의 환자를 제외한 나머지 환자를 대상으로 하였을 때 24.3%(9/37)를 나타내었다. 이러한 사망률과 종격동 감염율에 미치는 위험 인자로 수술 시간, 인공심폐기 사용기간, 대동맥 결찰시간, 수술후 흉골을 열고 있었던 기간, 인공호흡기를 하고 있었던 기간을 설정 후 이에 대한 단변량 분석결과 대동맥 결찰 시간만이 사망률에 대해 의미를 가졌으나 다변량 분석결과에서는 통계학적 의미를 갖지 못했다. 결론: 선천성 심장병 수술후 지연 흉골 봉합을 하는 경우 상대적으로 높은 사망률과 종격동 감염률을 보였으나 수술후 혈역학적 불안정상태 및 출혈, 도관이 눌러는 경우 등에 있어서 수술당시 흉골 봉합을 시도했다면 더 높은 사망률이 예상된다. 이러한 경우에 있어 지연 흉골 봉합을 통하여 더 높은 생존율을 기대할 수 있다.

피부모사체 계면활성제를 사용한 라멜라 액정의 생성에 관한 연구 (A Study on the Formation of Lamellar Liquid Crystalline Using Skin Mimicking Surfactant)

  • 김인영;남은희;신문삼
    • 한국응용과학기술학회지
    • /
    • 제37권3호
    • /
    • pp.484-495
    • /
    • 2020
  • 이 연구는 피부 각질층의 구조와 동일한 구조를 형성하는 혼합계면활성제 (MimicLipidMSM1000)로써 수크로오스다이스테아레이트, 폴리글리세릴-2다이올리에이트, 발효스쿠알란, 에르고스테롤, 10-하이드록시스테아릭애씨드로 이루어진 혼합물을 합성하였다. 이 혼합 계면활성제를 2~5wt%를 사용할 경우, 5~30층의 다중층 라멜라구조를 형성하는 인공 피부 모사체를 만들 수 있었다. 이 혼합계면활성제를 사용하여 에멀젼을 만들고, 다중층의 라멜라 상이 형성되는 것을 메커니즘 적으로 해석하였다. 이 계면활성제의 외관은 연한 갈색의 단단한 왁스이었고, HLB(hydrophilic lipophilic balance)는 12.53이었으며, 임계파라미터 값(critical parameter value)은 0.987, 산가는 0.13이었다. pH변화에 따른 안정성은 산성(3.8), 중성(7.2), 알칼리성(10.8)에서도 안정하였다. 액정의 입경은 5~25mm에서 가장 안정한 십자형 모양 (maltese cross) 라멜라액정 드롭플렛(lamellar crystalline droplet)이 형성됨을 알 수 있었다. 호모믹서의 교반속도 변화에 따른 유화입자의 크기는 2500rpm (17.9mm±2.6mm), 3500rpm (12.5mm±2.1mm), 4500rpm (6.2mm±1.8mm) 속도가 높아 질수록 작은 입자가 형성되었다. 편광현미경을 통하여 액정형성 입자를 관찰하였으며, 주사전자현미경(cryo-SEM)으로 액정의 형성 구조를 정밀하게 분석하였다. 응용분야로써, 각질층의 다중 라멜라 동일한 구조를 형성하는 피부모사체 형성 계면활성제를 사용하여 다양한 스킨케어화장료, 메이크업 케어 화장료, 두피보호용 화장료 등 다양한 처방개발에 폭 넓게 응용이 가능할 것으로 기대한다.

자기생산 기계 시스템과 3차 사이버네틱스의 등장 (Autopoietic Machinery and the Emergence of Third-Order Cybernetics)

  • 이성범
    • 비교문화연구
    • /
    • 제52권
    • /
    • pp.277-312
    • /
    • 2018
  • 1940년대와 50년대에 등장한 1차 사이버네틱스 이론은 관찰 주체를 배제한 채 관찰하고자 하는 대상에 대한 객관적이고 보편적인 작동 메커니즘을 연구하는 방법론이다. 반면에 1970년대에 등장한 2차 사이버네틱스 이론은 시스템을 관찰하는 관찰자의 인식론적 구조 자체를 연구 대상으로 여기면서 인식 방식의 주관성, 개별성, 다양성을 인정하는 방법론이다. 훔베르토 마투라나와 프란시스코 바렐라는 2차 사이버네틱스의 탐구 영역을 인간 관찰자로 대표되는 생물학적 시스템의 작동 메커니즘 연구로 확대한다. 그들은 살아있는 시스템이 지닌 자기 조직화와 자기 재생산 메커니즘을 규명하는 일을 2차 사이버네틱스의 핵심적 연구 과제로 여긴다. 생물학적 시스템이 지닌 자기생산 능력을 기계적으로 재현하는 시스템 탐구는 통제 메커니즘 연구를 새로운 단계로 나아가게 하므로 3차 사이버네틱스라고 불릴만하다. 1차 사이버네틱스가 관찰자를 배제한 채 객관적 시스템에 대한 통제 기제를 탐구하고 2차 사이버네틱스는 인간으로 대변되는 생물학적 작동 메커니즘을 탐구한다면 3차 사이버네틱스에서는 살아 움직이는 시스템을 인위적으로 재창조하는 생명-기계 융합 시스템을 연구한다. 생물학적 시스템의 기계적 재생산을 현실화하는 일은 클라우스 슈밥의 4차 산업 혁명이나 에릭 브린욜프슨과 앤드루 맥아피가 제안하는 제2 기계 시대의 핵심적 화두 중 하나이다. 자기생산의 인위적 재현이 가능하게 되면 인간중심주의에서 인간과 기계가 다양한 형태로 결합되는 포스트휴먼 시대로 나아간다. 미국 소설가 딘 쿤츠의 소설 "악마의 씨앗"은 기계의 자기생산 능력을 주제로 삼는다. 1973년판과 이를 개정한 1997판를 비교하면 작가의 논점이 2차 사이버네틱스에서 3차 사이버네틱스로 변하고 있음을 읽을 수 있다. 1973년판에서는 과학 기술에 대한 공포심을 보여주는 인간 관찰자와 기술 만능을 주창하는 인공지능 프로테우스의 차이가 부각되나 궁극적으로는 인간 관찰자가 담론의 주도권을 행사하고 있다. 1973년에 비해 훨씬 기술 지배력이 강화된 1997년도에 출판된 수정본에서는 과학 기술에 대해 공포감을 느끼는 인간 화자는 사라지고 기술 만능을 자랑하는 인공지능 프로테우스가 처음부터 끝까지 이야기를 주도한다. 더 나아가 그는 첨단 지능뿐 아니라 인간 주인공 수잔에게 성적 갈망을 표출하는 남성적 정체성을 획득하여 더 이상 인간의 통제 대상으로 이용되는 기계가 아닌 이성을 욕망하는 능동적 주체가 된다. 남성 정체성 획득은 프로테우스의 기계적 자율성이 극대화됨을 의미한다. 여기서 우리가 주목할 만한 일은 프로테우스가 만든 인공지능 아이는 과학기술을 활용한 우생학이 앞으로 도래할 미래에 보편화될 수 있다는 우려를 낳게 하는 존재라는 사실이다. 프로테우스는 인간의 유전병을 고치고 유전자를 변형하여 완벽한 신체를 꿈꾼다. 또한 방대한 첨단 지성을 인간-기계 생명체에 주입하여 최고의 지성을 갖추도록 기획한다. 즉 그는 상품가치를 지닌 우수한 신체적 조건과 지적 자질을 기계적으로 재현하는 능력을 갖춘다는 측면에서 디지털 표준화를 추구한다. 결국 이런 기술적 우생학은 고전적 휴머니즘이 지닌 장점에 심각한 위해를 가하는 결과를 초래한다. 인간은 양도할 수 없는 자기 운명의 주관자가 아니라 언제든지 공학적으로 변경 가능한 구성물로 전락할 위험성을 동반하기 때문이다.

페루 - 볼리비아 접경 푸노(Puno) 지역 아이마라(Aymara)원주민 종족갈등의 원인 (The Historical Origin of the Conflict of the Aymara of Peru and Bolivia, Centered on Puno)

  • 차경미
    • 비교문화연구
    • /
    • 제41권
    • /
    • pp.351-379
    • /
    • 2015
  • 라틴아메리카 대륙에서 안데스 산맥지역은 다양한 원주민종족 집단이 집중적으로 분포되어 있다. 이러한 종족 중에서 아이마라족은 케추아족과 함께 가장 대표적인 원주민 집단을 구성한다. 특히 티티카카호수를 중심으로 페루와 볼리비아 양국 접경지역에 밀집되어 있는 아이마라 원주민은 각각 국가의 소속을 달리하지만 하나의 삶의 터전 속에 동일한 문화권을 형성하며 공통의 정체성을 추구해 왔다. 그동안 아이마라 원주민은 종족의 정체성을 구성하는 언어를 바탕으로 다른 원주민 집단과 구분되는 역사성과 특수성을 강조하며 동일종족으로서의 유대감을 유지해왔다. 그러나 최근 들어 양국 접경지역의 중심지인 푸노(Puno)주를 중심으로 아이마라 원주민의 종족갈등이 표면화 되고 있다. 독립이후 근대국가 건설과정에서 형성된 인위적인 영토 경계선으로 분리된 이후 라틴아메리카 원주민은 협조와 경쟁이라는 틀 속에서 문화적 유사성과 동시에 차이를 강조하기 시작하였다. 이러한 역사적 맥락과 함께 최근 들어 페루와 볼리비아 접경지역을 중심으로 동일한 종족이 서로 다른 국가의 틀에 묶이면서 발생하는 새로운 종족 갈등이 전개되고 있다. 아이마라 원주민은 외부와의 경쟁에서 문화와 역사적 특수성을 강조하며 자신들을 하나의 단일한 종족으로 인식하며 단결하지만, 내부의 이해관계를 둘러싸고 충돌할 경우 서로가 문화적 전통을 상실했다는 비난을 가하며 종족 내부에서도 차별과 구별의 정체성을 형성하는 경향을 나타냈다. 종족간의 갈등은 한 지역에 공존하고 있는 타 종족간의 갈등에서 비롯되는 경향이 있으나 페루와 볼리비아 아이마라 원주민의 경우 양국이 접경을 유지하고 있는 푸노주를 중심으로 오랜 역사를 통해 형성된 종족의 유대감이 현실의 조건에 의해 갈등구조로 변화하는 양상을 타나내고 있다. 이러한 점에 착안하여 본 연구는 아이마라 원주민 종족갈등의 심화원인을 분석하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF