• Title/Summary/Keyword: artifact analysis

Search Result 282, Processing Time 0.03 seconds

Comparison of Images Using Optimized Grid and Images Using Grid Supperession Software in the Diagnosis of Micro Lesions (미세병변 진단에서 Optimized Grid을 사용한 영상과 Grid Supperession Software를 사용한 영상의 비교분석)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.149-155
    • /
    • 2018
  • Quantitative analysis was performed to confirm that moire artifact was removed without loss of image when using grid suppression software in the diagnosis of micro lesions. we showed that grid suppression images can be morphologically different from original images as they are significantly lower than those of the optimized grid in the similarity analysis with reference images in mammographic phantom images. We were confirmed that images of microcalcification with smaller signal than noise were lost because the pixel values of all lesions increased significantly after the grid suppression, The change in contrast using the NORMI 13 X-ray test phantom was reduced to 30% of the reference image, This result was significantly lower than the 90% when using the optimized grid. In conclusion, the use of grid suppression software in clinical images should be carefully considered because of the possibility of misdiagnosis due to micro lesion loss and morphological changes.

Design and Performance Improvement of a Digital Tomosynthesis System for Object-Detector Synchronous Rotation (물체-검출기 동기회전 방식의 X-선 단층영상시스템 설계 및 성능개선에 관한 연구)

  • Kang, Sung-Taek;Cho, Hyung-Suck;Roh, Byung-Ok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.4
    • /
    • pp.471-480
    • /
    • 1999
  • This paper presents design and performance improvement of a new digital tomosynthesis (DTS) system for object-detector synchronous rotation. Firstly, a new DTS system, called OSDR (Object-Detector Synchronous Rotation) is suggested and designed to acquire X-ray digital images. Secondly, the shape distortion of DTS images generated by an image intensifier is modeled. And a new synthesis algorithm, which overcomes the limitations of the existing synthesis algorithm, is suggested to improve the sharpness of the synthesized image. Also an artifact analysis of the DTS system is performed. Thirdly, some performance indices, which evaluate quantitatively performance improvement, are defined. And the experimental verification of the performance improvement is accomplished by the ODSR system newly designed. The advantages of the ODSR system are expressed quantitatively, compared with an existing system.

  • PDF

Effectiveness of a Turbo Direction Change for Reduction of Motion Artifact in Magnetic Resonance Enterography

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.421-424
    • /
    • 2016
  • The purpose of this study is to evaluate an effectiveness of switching turbo direction to improve motion artifacts of small bowels and aorta. From June to October 2015, 60 patients suspected of having Crohn's disease were enrolled. The MR Enterography scans were performed using same protocol other than the turbo direction: with the Z phase encoding (group A) and with Y phase encoding (group B). Qualitative analysis of each group was performed to evaluate the effectiveness of switching turbo direction from Z to Y. As a result, the 5-point Likert scale for paired observers were $2.33{\pm}0.88$ for group A and $3.80{\pm}0.85$ for group B on dynamic contrast enhanced coronal images. In conclusion, group B is proved to be superior to group A and can lessen the motion artifacts derived from phase shifts.

Artifacts characteristic analysis of EEG (EEG의 잡파 특성 분석)

  • 양은주;조한범;김응수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.87-90
    • /
    • 2002
  • 뇌파(Electroencephalogram, EEG)는 뇌 신경세포가 정보를 처리하는 과정에서 발생하는 전기적인 신호를 두피 표면에서 측정한 것이다. 이러한 뇌파는 비침습적인 방법으로 전기적인 신호를 측정하며 측정시 여러 잡파(artifact)가 섞이기 쉽다. 이러한 잡파는 뇌의 정보처리과정에 대한 유용한 정보를 담고 있는 뇌파를 분석하는데 방해가 되므로 이를 제거하기 위한 노력이 계속되어 왔다. 그러나 본 연구에서는 보다 적극적인 방향으로 잡파가 섞인 뇌파의 특성을 분석하여 이를 통해 제어 시스템 등과 같은 시스템에 적용할 수 있는 가능성을 알아보았다. 대표적인 잡파인 eye_blinking, eye_rolling, muscle 등이 각각 포함된 뇌파에 대해서 선형 및 비선형 분석을 실시함으로써 유의미한 특성 차이를 나타내었다.

  • PDF

Compensation of Thermal Error for the CNC Machine Tools (I) - The Basic Experiment of Compensation Device - (CNC 공작기계의 열변형 오차 보정 (I) - 보정장치 기초실험 -)

  • 이재종;최대봉;곽성조;박현구
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.453-457
    • /
    • 2001
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric and thermal errors of the machine tools. In this study, the compensation device is manufactured in order to compensate thermal error of machine tools under the real-time. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to compensate thermal characteristics under several operating conditions, experiments performed with five gap sensors and manufactured compensation device on the horizontal machining center.

  • PDF

Physical Artifact Correction in Nuclear Medicine Imaging: Normalization and Attenuation Correction (핵의학 영상의 물리적 인공산물보정: 정규화보정 및 감쇠보정)

  • Kim, Jin-Su;Lee, Jae-Sung;Cheon, Gi-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.112-117
    • /
    • 2008
  • Artifact corrections including normalization and attenuation correction were important for quantitative analysis in Nuclear Medicine Imaging. Normalization is the process of ensuring that all lines of response joining detectors in coincidence have the same effective sensitivity. Failure to account for variations in LOR sensitivity leads to bias and high-frequency artifacts in the reconstructed images. Attenuation correction is the process of the correction of attenuation phenomenon lies in the natural property that photons emitted by the radiopharmaceutical will interact with tissue and other materials as they pass through the body. In this paper, we will review the several approaches for normalization and attenuation correction strategies.

Evaluation of Image Usability by SEMAC Turbo Factor Change using Susceptibility Artifact Reduction (Susceptibility Artifact를 감소시키는 SEMAC 사용 시 Turbo Factor 변화에 따른 영상의 유용성 평가)

  • Choi, Young-Jae;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2019
  • The study analyzes Non SEMAC and SEMAC to reduce susceptibility artifacts that may occur when performing magnetic resonance imaging(MRI) of metal patients. The Foot and Ankle Phantom was used as the experimental tool and the 3.8 cm general screw was used to make the magnetic susceptibility artifact. The experimental equipment was used 3.0T Magnetom Skyra and the area was measured with the 17th image where the signal off is the most noticeable in the obtained image. Statistical analysis was performed using the SPSS(Ver.25) program and the significance was assessed by the Wilcoxon Signed Rank Test. As a result, the area of Non SEMAC which is the lowest signal was $289.53{\pm}23.07197mm$. When the Turbo Factor was changed to 3, 4, and 5 after SEMAC use, it decreased to $125.02{\pm}7.45875mm$, $120.96{\pm}12.01704mm$ and $108.79{\pm}16.53498mm$, respectively. In conclusion, this study demonstrates that Using SEMAC with Turbo Factor effectively reduces the susceptibility artifacts.

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.

Image Enhancement Using The Contrast Sensitivity Function (Contrast Sensitivity 함수를 이용한 영상화질 개선 방법)

  • Bang, Seangbae;Kim, Wonha
    • Journal of Broadcast Engineering
    • /
    • v.20 no.2
    • /
    • pp.238-247
    • /
    • 2015
  • We develop the signal processing method for adaptive implementing direction of signal and the frequency sensitivity of human visual system(HVS). Existing multibnad energy scaling method makes ringing artifact because it does not consider signal direction. To solve this problem, we use block gradient for signal direction in addition to existing method. And we use the fact that frequency component of signal is more sensitive than value of signal over human eyes. we enhance the signal according to contrast sensitivity function(CSF) which is the model of frequency sensitivity of human eye. Compared that the existing analysis models only improve the efficiencies in the existing systems, the developed method can process the image signals to be more desirable and suitable to HVS.

An Analysis of the Cotton Fabric armour(綿甲) in the late Joseon Korea - with Emphasis on the Remaining Artifact in the National Museum of Korea - (조선 후기 면갑(綿甲) 유물 분석 - 국립중앙박물관 소장 유물을 중심으로 -)

  • Park, Ga Young;Song, Mi Kyung
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.4
    • /
    • pp.158-167
    • /
    • 2013
  • The cotton fabric armour for lower class soldiers can be found from the historical records of the mid-Joseon Korea. And the records show that the form and the structure of the armour was modified in the late 19th century in order to provide better protection from gunshots for the soldiers in the midst of the invasions from the West. This is a survey and research of the only artifact of the cotton fabric armour remaining in Korea - for its form, dimensions, and design. Using the historical records as reference, we can confirm the structure and characteristics of the cotton fabric armour of the Joseon period. This cotton fabric armour, preserved in National Museum of Korea, is a vest-type armour made of 30 layers of cotton. On the right shoulder, there is a button for tying knots and strings were tied under both armpits. On the surface of the cotton fabric armour there were some characters and patterns stamped in black. Presently, this artifact in Korea is the only specimen relic of its sort, but there are some other related relics in foreign countries including helmets and belts. Continuous researches would help extend the scope of armour study beyond the traditional researches that only focuses on the armours of the officials, thus helping us to understand the military costumes in traditional Korea.