• Title/Summary/Keyword: artifact analysis

Search Result 278, Processing Time 0.026 seconds

The Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis (독립 요소 분석을 통한 Photoplethysmography에서의 동잡음 제거)

  • 김경하;유선국;김병수;김남현
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.10
    • /
    • pp.598-605
    • /
    • 2003
  • In this paper, we propose the method that separates PPG signal and motion artifact signal from two input signals using new independent component analysis algorithm in time domain. In order to eliminate the large level artifact efficiently, block interleaving. lowpass time filtering and innovation processing technique were applied in ICA preprocessing, and FastICA algorithm were applicable. Experiments are made with the numerical simulation and the real PPG signal including four kinds of motion artifact pattern. Our results show that ICA can effectively detect, separate and remove motion artifact in input signals. Then from the separated signals we restore the original PPG signal and propose a new method which computes SpO$_2$ using ICA mixing matrix.

The Automatic Collection and Analysis System of Cloud Artifact (클라우드 아티팩트 자동 수집 및 분석 시스템)

  • Kim, Mingyu;Jeong, Doowon;Lee, Sangjin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.6
    • /
    • pp.1377-1383
    • /
    • 2015
  • As the cloud services users' increase, there are important files created by individual in cloud storage. Thus, investigation of cloud artifact should be conducted. There are two methods of analyzing cloud service, one is that investigates cloud server provider (CSP), and another is that investigates client. In this paper, we presents an automated framework to detect the altered artifact and developes a tool that detects the cloud artifact. We also developed Cloud Artifact Tool that can investigate client computer. Cloud Artifact Tool provides feature of collection and analysis for the services such as Google Drive, Dropbox, Evernote, NDrive, DaumCloud, Ucloud, LG Cloud, T Cloud and iCloud.

Seismic fragility analysis of sliding artifacts in nonlinear artifact-showcase-museum systems

  • Liu, Pei;Li, Zhi-Hao;Yang, Wei-Guo
    • Structural Engineering and Mechanics
    • /
    • v.78 no.3
    • /
    • pp.333-350
    • /
    • 2021
  • Motivated by the demand of seismic protection of museum collections and development of performance-based seismic design guidelines, this paper investigates the seismic fragility of sliding artifacts based on incremental dynamic analysis and three-dimensional finite element model of the artifact-showcase-museum system considering nonlinear behavior of the structure and contact interfaces. Different intensity measures (IMs) for seismic fragility assessment of sliding artifacts are compared. The fragility curves of the sliding artifacts in both freestanding and restrained showcases placed on different floors of a four-story reinforced concrete frame structure are developed. The seismic sliding fragility of the artifacts within a real-world museum subjected to bi-directional horizontal ground motions is also assessed using the proposed IM and engineering demand parameter. Results show that the peak floor acceleration including only values initiating sliding is an efficient IM. Moreover, the sliding fragility estimate for the artifact in the restrained showcase increases as the floor level goes higher, while it may not be true in the freestanding showcase. Furthermore, the artifact is more prone to sliding failure in the restrained showcase than the freestanding showcase. In addition, the artifact has slightly worse sliding performance subjected to bi-directional motions than major-component motions.

Quantitative Evaluation of CT Artifact Elimination with various Cut-off Frequency of Hann Filter (Hann 필터의 Cut-off 주파수 변화에 따른 CT 영상의 Artifact 제거효과에 대한 정량적 평가)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.3
    • /
    • pp.5-9
    • /
    • 2008
  • In the computerized tomography(CT), various filters are using in the reconstruction algorithm to reduce or eliminate the artifacts which are intrinsically induced by the imperfection of mathematical methods for reconstruction, lack of real informations about anatomic structures in the projection image, errors in data acquisition and so on. Hann filter was used to evaluate the filter effects on the elimination of reconstruction artifact in the CT image. The quantitative study was done by changing cut-off frequency of Hann filter from 0.1 to 0.9 with frequency increasement by 0.2. NPS analysis was fulfilled for the quantitative evaluation of filter effect.

  • PDF

A Comparative Performance Analysis of Blocking Artifact Reduction Algorithms (블록화 현상 제거 알고리듬의 성능 비교 분석)

  • 소현주;장익훈김남철
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.907-910
    • /
    • 1998
  • In this paper, we present a comparative performance analysis of several blocking artifact reduction algorithms. For the performance analysis, we propose a block boundary region classification algorithm which classifies each horizontal and vertical block boundary into four regions using brightness change near the block boundary. The PSNR performance of each algorithm is compared. The MSE according to each block boundary region is also compared. Experimental results show that the wavelet transform based blocking artifact reduction algorithms have better performance over the other methods.

  • PDF

Volumetric Error Measurement and Calibration of Coordinate Measuring Machines Using a Ball-bar Artifact (Ball-Bar Artifact를 이용한 CMM의 공간 오차 측정 및 분석)

  • 구상서;이응석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.143-148
    • /
    • 2001
  • Volumetric error measurement and calibration of a coordinate measuring machine are studied by using a Ball-Bar artifact. Examples of the Ball-Bar design are shown using inbar materials and precision steel balls. Also, for the uncertainty error using the Ball-Bar is discussed. Method of Ball-Bar artifact and the analysis of the error vectors are proposed. Using the Ball-Bar data, we studied the method of volumetric errors ana]ysis of a coordinate measuring machine.

  • PDF

Analyses on Artifacts of Koryo Kynasty Excavated from Hyungok-ni Danyang (단양 현곡리 출토 고려시대 섬유류 및 지류 유물에 관한 연구)

  • 안춘수;박희현
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1161-1169
    • /
    • 1999
  • This research was aimed to identify the artifact type and their characteristics of the textile related materials excavated from Koryo Dynasty tombs of Hyungok-ni Danyang. Microscopy solubility test energy dispersive X-ray spectroscopy(EDS) and fourier transform infrared spectroscopy (FT-IR) fabric density test were used for the identification and when necessary standard samples were made in order to compare its characteristics with hose of the original artifact, the result indicated that the artifacts included both textile and paper. Artifacts from Burial 14 were comprised of textile fragments FT-IR and the solubility test conducted on the artifact indicated that the textiles were made with ramie woven with plain weave technique in a fairly loose fabric density. Rest of the artifacts were all comprised of paper.

  • PDF

Magnetocardiogram Topography with Automatic Artifact Correction using Principal Component Analysis and Artificial Neural Network

  • Ahn C.B.;Kim T.H.;Park H.C.;Oh S.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.2
    • /
    • pp.59-63
    • /
    • 2006
  • Magnetocardiogram (MCG) topography is a useful diagnostic technique that employs multi-channel magnetocardiograms. Measurement of artifact-free MCG signals is essenctial to obtain MCG topography or map for a diagnosis of human heart. Principal component analysis (PCA) combined with an artificial neural network (ANN) is proposed to remove a pulse-type artifact in the MCG signals. The algorithm is composed of a PCA module which decomposes the obtained signal into its principal components, followed by an ANN module for the classification of the components automatically. In the experiments with volunteer subjects, 97% of the decisions that were made by the ANN were identical to those by the human experts. Using the proposed technique, the MCG topography was successfully obtained without the artifact.

Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation (독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출)

  • Jeon, Hak-Jae;Kim, Jeong-Do;Lim, Seung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

Nonlinear and Independent Component Analysis of EEG with Artifacts (잡파가 섞인 뇌파의 비선형 및 독립성분 분석)

  • Kim, Eung-Soo;Shin, Dong-Sun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.12 no.5
    • /
    • pp.442-450
    • /
    • 2002
  • In measuring EEG, which is widely used for studying brain function, EEG is frequently mixed with noise and artifact. In this study, the signals relevant to the artifact were distracted by applying ICA to EEG signal. First, each independent component which was assumed to be the source was separated by applying ICA to EEG which involved artifact relevant to the eye movement of a normal person. Next, the signal which was assumed to be artifact was removed from the separated 18 independent components, and the nonlinear analysis method such as correlation dimension and the Iyapunov exponent was applied to each reconstructed EEG signal and the original signal including artifact in order to find meaningful difference between the two signals and infer the anatomical localization of its source and distribution. This study shows it is possible not only to analyze the brain function visually and spatially for visually complex EEG signal, but also to observe its meaningful change through the quantitative analysis of EEG by means of the nonlinear analysis.