• 제목/요약/키워드: area average rainfall

검색결과 283건 처리시간 0.023초

The Application of Geosynthetic Reinforced Soil Method in the Failed Slopes (붕괴사면 복구를 위한 보강토 공법의 적용)

  • Cho, Yong-Seong;Kim, You-Seong;Park, Inn-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2005
  • It is unavoidable to be formed slopes under special circumstance of Korea where 70% of the whole area are composed of mountains when civil engineering projects such as roads, site developments are increased with industrial development and horizontal expansions of urban area. Moreover, stability of the slopes become one of quite important issues under special meteorological characteristics that over two-thirds of annual average rainfall are concentrated in summer season and the localized torrential downpour are getting more frequent recently. Resulting in these circumstances, partial slope failures by debris flow of the high water content soils are occurred frequently in cutting soil slopes. In this case of debris flow slope failure, slope declination method are selected for their stable recovery because it is impossible to recover entirely by existing recovery methods. Seeding or special grass planting methods are followed separately without exception. The method by which entire recover with bigger stability ratio would be possible and grass planting work would be done simultaneously is developed. In this study, the results of the tests including a real construction history in a failed slope using developed method are described

  • PDF

Evaluation of the Water Purification Efficiency of Waste LCD Glass Media by Using Foaming Technology (발포기술을 이용한 폐 LCD유리 여재의 수질정화능력 평가)

  • Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제24권4호
    • /
    • pp.369-376
    • /
    • 2010
  • The purpose of this study is to reprocess Waste-LCD(Liquid Crystal Display), to widely increase specific surface-area by foaming agent in the process of reprocessing and to use as a substrate of water treatment which is increased the ability of biological treatment, as well as to control non-point source pollutants produced by surface run off during rainfall with using this substrate, and to improve water quality of public watershed as developing substrate for water treatment to be able to purify second treated water which is exhausted at the wastewater treatment plant. The average removal efficiency of Waste-LCD that using the foaming technology was SS 71.2%, BOD 55.7%, COD 58.4%, T-N 29.5% and T-P was 50.3%. Almost Media, early stage showed low removal efficiency of SS and BOD. However, it became high when the microorganism adhered the Media. The variation of SS removal efficiency was high by inflow concentration of SS. The reason for the Media 4 showed high SS removal efficiency is that it has wide specific surface-area, and also it has a pore. All in all, it shows floating matter treatment ability not only inside but it also works outside of the substrate.

Evaluation on applicability of on/off-line parameter calibration techniques in rainfall-runoff modeling (온·오프라인 매개변수 보정기법에 따른 강우-유출해석 적용성 평가)

  • Lee, Dae Eop;Kim, Yeon Su;Yu, Wan Sik;Lee, Gi Ha
    • Journal of Korea Water Resources Association
    • /
    • 제50권4호
    • /
    • pp.241-252
    • /
    • 2017
  • This study aims to evaluate applicability of both online and offline parameter calibration techniques on rainfall-runoff modeling using a conceptual lumped hydrologic model. To achieve the goal, the storage function model was selected and then two different automatic calibration techniques: SCE-UA (offline method) and particle filter (online method) were applied to calibrate the optimal parameter sets for 9 rainfall events in the Cheoncheon catchment, upper area of the Yongdam multi-purpose dam. In order to assess reproducibility of hydrographs from the parameter sets of both techniques, the observed discharge of each event was divided into low flow (below average flow) and high flow (over average flow). The results show that the particle filter method, updating the parameters in real-time, provides more stable reproducibility than the SCE-UA method regardless of low and high flow. The optimal parameters estimated by SCE-UA are very sensitive to the selected objective functions used in this study: RMSE and HMLE. In particular, the parameter sets from RMSE and HMLE demonstrate superior goodness-of-fit values for high flow and low flow periods, respectively.

Effect of Acid Deposition on the Acidification of Surface Water I : A Field Study (산성강하물이 지표수의 산성화에 미치는 영향 I: 현장 조사)

  • 김영관;이동석;김만구;우경식
    • Journal of Korea Soil Environment Society
    • /
    • 제1권2호
    • /
    • pp.15-21
    • /
    • 1996
  • Effects of acid deposition on the acidification of surface water over a short term period were studied during June~October, 1995. A reservoir located in Chunchon, Kangwondo was selected for this study because this reservoir had received little man-made pollutants. Geological survey within the study area was carried out and the pH of a small and shallow stream flowing from the mountain valley down to the reservoir was monitored. Rainfall was measured by using a rain gauge and the precipitation was collected by automatic precipitation sampler. During the study period, rain pH was in the range of 3.81~5.77 with an average of 4.8. The EC was in the range of 5~189$\mu$S/cm with an average of 10.6$\mu$S/cm. ionic composition of the rainfall showed that of the anions, deposition of ${SO_4}^{2-}$, was highest with 3,119.7 kg/$\textrm{km}^2$, and it was $NH^{4+}$ with 1,053.2kg/$\textrm{km}^2$ for cations. The surface water pHs were maintained neutral or weak basic representing little evidence of acidification regardless of the acidic rainfall pH. Every time of sampling, however, the pHs exhibited increasing tendency as elevation of measuring site of the stream became lowered, which indicated the impacts of acid-base reactions by acidic or basic substances during travel of water downstream. This result suggested the necessity of further research to determine the respective buffering capacity of soil and underlying rocks.

  • PDF

A Study on the Evaluation of Potential Hydro-electric Power in North Korea (북한의 수력발전가능량 산정 및 평가에 대한 연구)

  • Park, Miri;Ahn, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제38권1호
    • /
    • pp.41-49
    • /
    • 2018
  • This study is to analyze and evaluate water resource development potential in North Korea. The study was conducted to analyze selected potential hydropower as an indicator to evaluate water resource development potential. Potential hydropower means theoretical value about the potential capacity of river. It is used to evaluate the amount of development through the hydropower generation. For calculating potential hydropower, monthly average and annual average of rainfall for each river basin were calculated by using the data of 27 rainfall stations in North Korea. As a result of the calculation of theoretical potential hydropower by rainfall in the seven major basins in North Korea, the Aprok River basin was analyzed to be the largest with $7,562.2{\times}10^3kW$. The efficiency and utilization rate of theoretical potential hydraulic power in South Korea and North Korea was 42.3% and 36.2%, respectively. The Daedong River basin's potential hydropower utilization rate is 12.3%, which is the lowest in North Korea. In the case of Daedong River basin, more than 40% of the total population is inhabited, so demand for water and electricity is expected to be the largest. Therefore, the Daedong River basin is considered as a priority area for water resource development. The results of this study are expected to be used as basic data for future water resource development projects and research activities in North Korea.

Analysis of the Discharge Characteristics of Non-point Pollutants from the Interception Facilities according to Rainfall Conditions (강우조건에 따른 차집시설에서의 비점오염물질 유출특성분석)

  • Lin, Zi-Yu;Eun, Beomjin;Heo, Jeong Sook;Choi, I Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2022
  • This study was carried out to understand the water quality characteristics of the initial stormwater runoff and the origin of soluble pollutants according to various rainfall conditions from a non-point source reducing facility. The water sample from this study was collected among 10 collection facilities in the G-drainage area. Specifically, five of the collection points including #1, #5, #8, #9, and #10 were reported with unknown water inflow even during non-rain conditions. The leakage characteristics of non-point pollutants from the collection facilities were then able to identify accordingly. The water quality characteristics of the stormwater runoff from the collection facilities were strongly affected by the amounts of rainfalls. The average concentrations of EC, BOD, TOC, and TN during non-rain were found to be higher than their concentrations during rain; on the other hand, the average concentrations of DO were found to be lower than its concentrations during rain. In addition, the distribution of organic components existing in the effluent of collection facilities were identified based on the dissolved organic matter analysis. In summary, the stormwater runoff was highly affected by pollutants flowing from the surrounding environment, and the amounts of hard-to-decompose humic substances were greatly increased in the collection facilities due to rain.

Groundwater Balance in Urban Area (도시지역의 지하수수지)

  • Lee, Seung-Hyun;Bae, Sang-Keun
    • Journal of Environmental Science International
    • /
    • 제20권12호
    • /
    • pp.1553-1560
    • /
    • 2011
  • The study analyzes groundwater balance with regard to the water recharge and discharge which contain urbanization components in Suyeong-gu, Busan. It also verifies the reliability and accuracy improvement on the analysis of the balance. The result of the study is viewed as preliminary data which are useful to develop, utilize and manage groundwater. The average quantity of groundwater recharge is 6,014.1 $m^3$/day in the research area during the last ten year period(from 1998 to 2007). The outflow from drainage areas to rivers and coasts is 149.3 $m^3$/day, the inflow from rivers and coasts to drainage area is 439.9 $m^3$/day. The use of the water is 4,243.0 $m^3$/day. The outflow caused by subway in line No.2 and No.3 through Suyeong-gu and the one by building an underground electric complex is 1,500.0 $m^3$/day. The leakage of water works is 6514.9 $m^3$/day. The inflow and outflow of sewerage is 5082.2 $m^3$/day from groundwater to sewer. The amount of groundwater recharge, the inflow from rivers and coasts to drainage area, and the leakage of water works belong to the amount of groundwater inflow and the total amount is 12,968.9 $m^3$/day. The amount of outflow from drainage area to rivers and coasts, the use of groundwater, outflow by subway and underground electric complex tunnel and the amount of inflow of the water to sewerage belong to the amount of outflow of groundwater and the sum amount is 13,031.5 $m^3$/day. The gap between the amount of inflow and outflow of groundwater is 62.6 $m^3$/day, which is considered to reflect the trend that the short term drop in the amount of rainfall results in the amount of groundwater recharge and that the amount of outflow from drainage area to rivers and coasts decreases.

The Soil Loss Analysis using Landcover of WAMIS - for Musimcheon Watershed - (WAMIS 토지피복도를 활용한 토양유실량 분석 - 무심천 유역을 대상으로 -)

  • Kim, Joo-Hun;Lee, Chung-Dae;Kim, Kyung-Tak;Choi, Yun-Seok
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • 제10권4호
    • /
    • pp.122-131
    • /
    • 2007
  • This study estimates how soil loss in a basin has been occurred according to the change of land cover, and analyzes which type of land cover has the largest soil loss by classifying the land-cover type into each area and a whole basin. Musimcheon, the second branch stream of GeumGang, is chosen as a research area. The result of analysis shows that the average soil loss occurs most largely in a crop land and a paddy field. The yearly soil loss of watershed estimates approximately 14,000 ton/yr in case of using 100-year-frequency rainfall data. A forest area, which takes the largest area in watershed, shows the soil loss occurs approximately 1,000ton/yr. A crop field shows that soil loss increased most largely 4,900 ton/yr (34.6%) in 1985 to 8,100 ton/yr (56.1%) in 2000. The change of land cover in a crop land increased 8% to 14%, and this change influences on the increase of soil loss. As a result of analyzing the area over $200ton/km^2/yr$, the soil loss in a crop field accounts for 74% to 96%.

  • PDF

A comprehensive analysis of temporal characteristics in independent rainstorm events in Seoul: focusing on changes in unit time and secondary peak constant (서울특별시 내 독립 호우사상의 시간분포 특성 분석: 분 단위와 차첨두 상수의 조건 변화를 중심으로)

  • Cha, Hoyoung;Lee, Jinwook;Jun, Changhyun;Byun, Jongyun;Baik, Jongjin
    • Journal of Korea Water Resources Association
    • /
    • 제56권11호
    • /
    • pp.785-799
    • /
    • 2023
  • In this study, we proposed a new concept termed the Secondary Peak Constant (SPC) and discerned the temporal characteristics of independent rainstorm events based on unit time and SPC about 24 observation stations in Seoul. Utilizing rainfall observations from 2000 to 2022, independent rainstorm events discreted from rainfall data per unit time. The temporal characteristics of these events were derived according to unit time, and temporal characteristics of the peak rainfall were identified through the SPC. Finally, the temporal characteristics of independent rainstorm events were examined distinctively when analyzed by unit time and SPC. Independent rainstorm events with smaller unit time showed significantly larger total rainfall, rainfall duration, and rainfall intensity. The temporal characteristics of the largest peak rainfall (1st Peak) within independent rainstorm events followed a sequence of Q4>Q2>Q3>Q1. Additionally, the 2nd Peak rainfall predominantly occurred the location where the 1st Peak appeared. The proportion of independent rainstorm events with multiple peak rainfalls exceeded 50.0% when the SPC was 0.7 or lower. The average number of peak rainfalls within independent rainstorm events ranged from 1.5 to 3.4. This study identified the temporal characteristics of independent rainstorm events based on unit time. Then, the peak rainfall of temporal characteristics was quantified by SPC on this study. Hence, it is evident that the temporal characteristics of independent rainstorm events for specific area can be anlayzed and quantified based on unit time and SPC.

Analysis of the Factors Affecting Nutrients Removal in Hybrid Constructed Wetland Treating Stormwater Runoff (강우 유출수 처리를 위한 하이브리드 인공습지의 영양물질 저감 인자 분석)

  • Gurung, Sher Bahadur;Geronimo, Franz Kevin F.;Choi, Hyeseon;Hong, Jungsun;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • 제20권1호
    • /
    • pp.54-62
    • /
    • 2018
  • Nutrients generated from various land uses lead to eutrophication during the influx of water, and it is necessary to apply the LID techniques to reduce nutrients from nonpoint sources in order to mitigate the occurrence of the algal bloom. This study was carried out to derive the design factors of hybrid artificial wetland (HCW) to increase the removal efficiency of nutrients. HCW system was constructed in the year 2010 for the treatment of rainfall runoffs from parking lots and roads composed of 100% impervious floors in the Cheonan campus of Kongju University. The average nutrients removal efficiency of TN and TP was 74% and 72%, respectively. Both TN and TP removal efficiencies were higher than those of free surface wetlands and subsurface flow wetlands due to activated physical and ecological mechanisms. The critical design parameters for the efficient nutrients removal in the artificial wetlands were the ratio of the surface area to the catchment area (SA/CA), land use, the rainfall runoff, and the rainfall intensity. The optimal carbon to nitrogen (C/N) ratio was estimated at 5: 1 to 10.3: 1. The results of this study can be applied to the efficient design of hybrid artificial wetlands to treat nutrients in urban runoff with high efficiency.