• 제목/요약/키워드: architectural glass

검색결과 212건 처리시간 0.031초

경량 태양광발전 블라인드 개발 및 제어조건에 따른 음영분석 (Developing the Light-weight PV Blind System and the Shading Analysis by the Control Conditions)

  • 정유근
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.83-88
    • /
    • 2015
  • This study aims to develope the light-weight PV blinds with windows and to investigate the shading analysis by the control conditions. For the study, the polycarbonate characteristics and coating methods are analyzed and the PV blind design for a small office is suggested. Also, the mock-up model of a suggesting system was made. The field tests were controled based on a solar altitude under clear sky conditions. As results, it is necessary to use a polycarbonate instead of a tempered glass for a light-weight PV. The shading effects of blind systems are high in slat angle $30^{\circ}$ and low in $0^{\circ}$. Also, the shading ratio is more affected by solar latitude than solar altitude. The shading change rate is relevantly constant on the solar altitude.

Post-Damage Repair of Prestressed Concrete Girders

  • Ramseyer, Chris;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제6권3호
    • /
    • pp.199-207
    • /
    • 2012
  • Concrete is an economical construction material and for that reason it is widely used in buildings and infrastructures. The use of deicing salts, expansion joint failure, and freeze-thaw cycles have led to concrete bridge girders experiencing corrosion of steel reinforcement and becoming unsafe for driving. The goal of this research is to assess the effectiveness of current and possible repair techniques for the end region of damaged prestressed concrete girders. To do this, three American Association of State Highway and Transportation prestressed concrete girders were tested to failure, repaired, and retested. Three different repair materials were tested including carbon fiber, glass fiber, and surface mounted rods. Each different repair material was also tested with and without injected epoxy. Comparisons were then made to determine if injecting epoxy had a positive effect on stiffness and strength recovery as well as which repair type regained the largest percentage of original strength.

이중외피 창호특성에 따른 계절별 실내 주광환경 평가 (Evaluation of Seasonal Daylighting Performance according to Window Compositions of Double Skin Facades)

  • 임태섭;강승모
    • 한국실내디자인학회논문집
    • /
    • 제24권4호
    • /
    • pp.91-98
    • /
    • 2015
  • Double skin façade is known that several features affected the building energy and daylighting performance. That is why the envelope is able to consist of all architectural materials such as glass, aluminum, wood and insulation for vision of residents and workers in buildings. Its specifications is very diverse according to the building designers and building owners. In recent times, visual environment became a major focus and resulted in the development of cutting edge engineering of diverse glazing systems and shading devices by growing interests of friendly environment. Thus this research has evaluated the fluctuations of interior lighting and atmospheric conditions based on double skin facade systems. Especially in terms of daylighting environment as dependent on solar variations, this research provides quantitative analysis of interior lighting conditions and how it affects the living conditions as well as improve the design of interior spaces.

국내외 건축용 유리 및 커튼월의 안전 기준에 관한 연구 (A Study on the Safety Standard of Architectural Glass and Curtain Wall)

  • 김지영;김남혁;김동은;서동구;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 춘계학술논문발표회 논문집
    • /
    • pp.163-167
    • /
    • 2010
  • 최근 건축물의 초고층화에 따른 커튼월 시공에 따라 유리의 비중이 증가하고 있다. 커튼월 구조는 바람, 지진 등에 취약하며, 화재 안전성에 있어서도 취약할 것이라 판단되므로, 국내외 건축용 유리 및 커튼월의 안전기준에 대한 조사를 실시하였다. 그 결과 국내의 유리 기준은 단열 및 내풍압 성능에만 집중되어있으며, 화재 및 지진, 안전성능에 대한 기준이 미비하며, 커튼월에 대한 안전대책은 전무한 실정이다. 따라서 외국의 사례와 같이 초고층에서 커튼월의 안전성능을 고려한 설계프로세스나 안전 기준의 세부화가 필요하다고 판단된다.

  • PDF

막재료의 난연 및 방염성능 실험에 대한 연구 (Tests of Fire and Flame Retardant Performance for Membrane Materials)

  • 김기철;최광호
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

Investigating nonlinear forced vibration behavior of multi-phase nanocomposite annular sector plates using Jacobi elliptic functions

  • Mirjavadi, Seyed Sajad;Forsat, Masoud;Barati, Mohammad Reza;Hamouda, A.M.S.
    • Steel and Composite Structures
    • /
    • 제36권1호
    • /
    • pp.87-101
    • /
    • 2020
  • A multi-scale epoxy/CNT/fiberglass annular sector plate is studied in this paper in the view of determining nonlinear forced vibration characteristics. A 3D Mori-Tanaka model is employed for evaluating multi-scale material properties. Thus, all of glass fibers are assumed to have uni-direction alignment and CNTs have random diffusion. The geometry of annular sector plate can be described based on the open angle and the value of inner/outer radius. In order to solve governing equations and derive exact forced vibration curves for the multi-scale annular sector, Jacobi elliptic functions are used. Obtained results demonstrate the significance of CNT distribution, geometric nonlinearity, applied force, fiberglass volume, open angle and fiber directions on forced vibration characteristics of multi-scale annular sector plates.

Toward Net-Zero Energy Retrofitting: Building-Integrated Photovoltaic Curtainwalls

  • Kim, Kyoung Hee;Im, Ok-Kyun
    • 국제초고층학회논문집
    • /
    • 제10권1호
    • /
    • pp.35-43
    • /
    • 2021
  • With the rapid urbanization and growing energy use intensity in the built environment, the glazed curtainwall has become ever more important in the architectural practice and environmental stewardship. Besides its energy efficiency roles, window has been an important transparent component for daylight penetration and a view-out for occupant satisfaction. In response to the climate crisis caused by the built environment, this research focuses on the study of net-zero energy retrofitting by using a new building integrated photovoltaic (BIPV) curtainwall as a sustainable alternative to conventional window systems. Design variables such as building orientations, climate zones, energy attributes of BIPV curtainwalls, and glazed area were studied, to minimize energy consumption and discomfort hours for three cities representing hot (Miami, FL), mixed (Charlotte, NC), and cold (Minneapolis, MN). Parametric analysis and Pareto solutions are presented to provide a comprehensive explanation of the correlation between design variables and performance objectives for net-zero energy retrofitting applications.

스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이 (Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings)

  • 김재향;한승훈
    • 신재생에너지
    • /
    • 제19권3호
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

Experimental analysis of damage in short-fiber-reinforced composite waste polyethylene terephthalate as a pile foundation material

  • Jang, Hongseok;Seo, Segwan;Cho, Daesung
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.147-157
    • /
    • 2022
  • This study assessed the compressive and tensile strengths and modulus of elasticity of waste polyethylene terephthalate (PET) using the ASTM standard tests. In addition, short carbon and glass fibers were mixed with waste PET to examine the improvements in ductility and strength during compression. The bonding was examined via field-emission scanning electron microscopy. The strength degradation of the waste PET tested under UV was 40-50%. However, it had a compressive strength of 32.37 MPa (equivalent to that of concrete), tensile strength of 31.83 MPa (approximately ten times that of concrete), and a unit weight of 12-13 kN/m3 (approximately half that of concrete). A finite element analysis showed that, compared with concrete, a waste PET pile foundation can support approximately 1.3 times greater loads. Mixing reinforcing fibers with waste PET further mitigated this, thereby extending ductility. Waste PET holds excellent potential for use in foundation piles, especially while mitigating brittleness using short reinforcing fibers and avoiding UV degradation.

창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발 (Development of detachable air-cap module for improving the performance of windows)

  • 서범동;이행우;서장후;김용성
    • KIEAE Journal
    • /
    • 제17권1호
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.