• 제목/요약/키워드: architectural beam

검색결과 561건 처리시간 0.028초

Flexural tests on two-span unbonded post-tensioned lightweight concrete beams

  • Yang, Keun-Hyeok;Lee, Kyung-Ho;Yoon, Hyun-Sub
    • Structural Engineering and Mechanics
    • /
    • 제72권5호
    • /
    • pp.631-642
    • /
    • 2019
  • The objective of the present study is to examine the flexural behavior of two-span post-tensioned lightweight aggregate concrete (LWAC) beams using unbonded tendons and the reliability of the design provisions of ACI 318-14 for such beams. The parameters investigated were the effective prestress and loading type, including the symmetrical top one-point, two third-point, and analogous uniform loading systems. The unbonded prestressing three-wire strands were arranged with a harped profile of variable eccentricity. The total length of the beam, measured between both strand anchorages, was 11000 mm. The test results were compared with those compiled from simply supported LWAC one-way members, wherever possible. The ultimate load capacity of the present beam specimens was evaluated by the collapse mechanism of the plasticity theorem and the nominal section moment strength calculated following the provision of the ACI 318-14. The test results showed that the two-span post-tensioned LWAC beams had lower stress increase (Δfps) in the unbonded tendons than the simply supported LWAC beams with a similar reinforcement index. The effect of the loading type on Δfps and displacement ductility was less significant for two-span beams than for the comparable simply supported beams. The design equations for Δfps and Δfps proposed by ACI 318-14 and Harajli are conservative for the present two-span post-tensioned LWAC beams, although the safety decreases for the two-span beam, compared to the ratios between experiments and predictions obtained from simply supported beams.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;손국원
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.52-62
    • /
    • 2015
  • This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.

철근콘크리트 보-기둥 접합부 전단강도 평가 (Estimation of Shear Strength of Beam-Column Joints)

  • 최하영;김병일;이정윤
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.185-193
    • /
    • 2012
  • 이 연구에서는 인접한 보에 소성힌지가 발생하기 전에 접합부에서 전단파괴가 발생하는 내부 보-기둥 접합부의 전단강도를 평가하기 위해서 식을 제안하였다. ACI와 AIJ의 기존 기준식은 콘크리트의 압축강도만을 고려하여 평가하지만 제안식은 트러스 작용 또한 고려하고 있다. 제안식은 콘크리트의 연화효과를 반영하기 위해 적용하는 콘크리트 유효압축계수를 구할 때 수직, 수평 철근을 고려하여 접합부의 전단강도를 평가한다. 그 결과, $V_{test}/V_{cal}$의 평균은 1.14, 변동계수는 20%이고 ACI와 AIJ에 의한 평가보다 비교적 향상된 결과를 보였다. $V_{test}/V_{cal}$는 각 방향의 철근비에 따라 비슷한 경향을 보이고 있음을 알 수 있다.

외적 포스트텐셔닝 보강에서 데비에이터의 위치에 따른 전단보강효과 (Shear Strengthening Effect by Deviator Location in Externally Post-tensioning Reinforcement)

  • 이수헌;신경재;이희두
    • 대한건축학회논문집:구조계
    • /
    • 제34권6호
    • /
    • pp.3-10
    • /
    • 2018
  • This paper described the shear strengthening effect by deviator location in pre-damaged reinforced concrete (RC) beams strengthened with externally post-tensioning steel rods. Three reinforced concrete beams as control beam and eight post-tensioned beams using external steel rods were tested to fail in shear. The externally post-tensioning material was a steel rod of 22 mm diameter, and it had a 655 MPa yield strength and an 805 MPa tensile strength. Specimens depend on multiple variables, such as the number of deviators, location of deviator, and load pattern. The pre-damaged loads up to about 2/3 of ultimate shear capacities were applied to specimens using displacement control and the diagonal shear crack just occurred at these loading levels. And then, the post-tensioning up to when a strain of steel rod reaches about $2000{\mu}{\varepsilon}$ was continuously applied to beam. A displacement control was changed to a load control during post-tensioning. The post-tensioning resulted in increase of load-carrying capacity and restoration of existing deflection. Also, it prevented the existing diagonal cracks from excessively growing. Two deviators effectively improved the load capacity when compared with in case of test which one deviator at mid-span installed. When deviators were located near region which the diagonal crack occurred on, the strengthening impact by post-tensioning was greater.

강섬유 혼입률에 따른 철근콘크리트 외부 보-기둥 접합부의 내진성능에 대한 실험적 연구 (An Experimental Study on the Seismic Performance of Reinforced Concrete Exterior Beam-Column Joint with Steel Fiber Volume Fractions)

  • 이장재;배백일;최창식
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.15-23
    • /
    • 2018
  • The purpose of this study is to evaluate the anchorage capacity of longitudinal bars for reinforced concrete exterior beam - column joints with steel fiber volume fractions. For this purpose, the steel fiber volume fraction was set to 0, 1, 2%, and the performance was compared with that of each other specimens. According to the test results, the maximum strength of EX-HK-NJR-0 decreased by 13% compared with the control specimen and EX-HK-NJR-1 decreased by 3% compared to the control specimen. However, when 2% of steel fiber was mixed, the maximum strength increased about 56% compared to the control specimen. The energy dissipation capacity of EX-HK-NJR-0 (when no transverse steel bars are placed) decreased by 61% compared to the control specimen. In addition, the energy dissipation capacity of the specimens with a steel fiber content of 1% decreased by 5% and 2% increased by 94% compared to control specimen. EX-HK-NJR-1,2 and the control specimen EX-HK-JR-0 experienced yielding of the reinforcing bars at the column interface before maximum strength development. However, when the EX-HK-NJR-0, the reinforcing bars at the column interface experienced yielding after maximum strength development. Therefore, reinforcement of steel fiber is considered to reduce the required development length for yielding of steel bars.

노출강연선으로 보강된 하이브리드 건축용 OCB보의 실물모형 재하실험연구 (The Experimental Study of Full-scale Optimized Composite Beam (OCB) Reinforced with Open Strands)

  • 이두성;김태균;채규봉
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.471-480
    • /
    • 2015
  • 최근 국내의 건축구조는 공간활용을 극대화할 수 있도록 계획되고 있다. 공간활용의 장점을 실현하기 위하여 하이브리드 OCB (Optimized Composite Beam)를 개발하였다. 건축용 OCB는 부모멘트 구간에서는 노출강연선으로 보강된 H형강으로 구성되고 정모멘트 영역에서는 PSC 구조로 구성된다. 본 연구에서는 건축용 OCB의 휨성능을 조사하였다. 15 m 길이의 시험체를 제작하여 3점 휨실험을 실시하였다. 실험을 통해서 다음과 같은 결과를 얻었다. 1) 시험체의 재하실험에서 초기 균열은 설계사용 하중의 171%에서 발생되었다. 2)사용하중에서 처짐은 건축구조설계기준에 제시된 허용처짐량 이내로 만족하였다. 3)균열의 양상, 파괴모드 그리고 극한하중 등의 실험결과는 3D 수치해석결과와 비교검토되었다. 본 실험연구 결과로부터 건축용 OCB보의 구조적인 신뢰성이 입증되었다.

비내진 상세를 가진 RC 보-기둥 접합부의 지진 거동 (Seismic Behavior of Nonseismically Detailed Reinforced Concrete Beam-Column Joints)

  • 우성우;이한선
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.894-901
    • /
    • 2003
  • 본 연구의 목적은 비내진 상세를 가진 RC 구조물의 이력거동 특성과 내진성능 및 특성을 알아보기 위한 것이다. 이를 위해 10층 RC구조물의 내 외부 접합부를 선정하여 슬래브의 유무, 접합부내에서의 전단철근 유무, 외부 접합부의 보 하부 주근의 정착방향에 따라 6개의 1/3 축소 실험체를 만들어 반복횡하중 실험을 수행하였다. 실험결과 내부 접합부의 경우 슬래브의 유무에 관계없이 내진 비내진 상세의 상이에 따른 강도나 연성 능력의 변화는 크지 않는 것으로 나타났고, 외부 접합부의 경우 내부 접합부와는 달리 접합부 전단 보강근의 유무뿐만 아니라 하단 주철근 정착방향에서도 차이가 나기 때문에 비내진 상세의 강도나 연성 능력이 각각 10∼20%와 27% 정도 작은 것으로 나타났다. 또, 비내진 상세를 가지는 경우 국부 변형이 한 곳에서 집중되어 크게 나타남을 알 수 있으며, 슬래브가 있음으로 인해 휨에 의한 회전각을 억제하고 상향 전단변형을 억제하는 것으로 나타났다. 한편 보-기둥 접합부에서의 전단 보강근은 전단변형률에 거의 영향을 끼치지 않는 것으로 나타났다.

세미슬림 AU 합성보의 시공 단계 안전성 평가 (Safety Evaluation of Semi-Slim AU Composite Beam During Construction)

  • 김영호;김도범;김대진;김명한
    • 한국공간구조학회논문집
    • /
    • 제18권3호
    • /
    • pp.57-66
    • /
    • 2018
  • Recently various composite beams in which concrete is filled in the U-shaped steel plate have been developed for saving story height and reducing construction period. Due to the high flexural stiffness and strength, they are widely being used for the building with large loads and long spans. The semi-slim AU composite beam has proven to take highly improved stability compared to the existing composite beams, because it consists of the closed steel section by attaching cap-type shear connectors to the upper side of U-shaped steel plate. In this study the finite element analyses were performed to evaluate the safety of the AU composite beam with unconsolidated concrete which were sustained through the closed steel section during the construction phase. The analyses were performed on the two types of cross section applied to the fabrication of AU composite beams, and the results were compared to the those of 2-point bending tests. In addition, the flexural performance according to the space of intermittent cap-type shear connectors and the location of reinforcing steel bars for compression was comparatively investigated. Through the results of analytical studies, it is preferable to adopt the yield moment of AU composite beam for evaluating the safety in the construction phase, and to limit the space of intermittent shear connectors to 400 mm or less for the construction load.

연성 강봉을 사용한 프리캐스트 콘크리트 보-기둥 접합부의 내진성능 (Seismic Performance of Precast Concrete Beam-Column Connections Using Ductile Rod)

  • 이상진;홍성걸;임우영
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.695-705
    • /
    • 2014
  • 지진구역에 적용하기 위한 연성 강봉을 사용한 프리캐스트 콘크리트 (PC) 보-기둥 접합부를 제안한다. 기존의 DDC 시스템을 활용한 보-기둥 접합부, 파괴모드를 고려해 설계된 두 개의 PC 실험체, 그리고 일체형 RC 실험체가 내진성능를 위해 반복하중 하에서 실험하였다. 실험체는 현행 기준을 만족하도록 설계되었다. 변수는 PC 보 주철근의 항복강도이다. 실험결과 제안된 시스템은 내진기준을 만족하는 것으로 나타났다. 제안된 보-기둥 접합부의 변형능력과 에너지소산 능력은 기존의 DDC 시스템보다 우수한 것으로 나타났다.

목조 건축문화재의 훼손현황과 보수방안 연구 - 제천시 목조 건축문화재를 중심으로 - (A Study on the Repair Method and the Damage Status of Wooden Architectural Heritages - Focused on the wooden architectural heritages in Jecheon -)

  • 이완건
    • 한국실내디자인학회논문집
    • /
    • 제25권3호
    • /
    • pp.82-89
    • /
    • 2016
  • This study investigated the preservation status of wooden architectural heritages, designated as Chungcheongbuk-do designated heritage in Jecheon. The purpose of this paper is to find the damage cause and the preservation method of wooden architectural heritages. It was conducted using the research methods of the existing literature and field survey to compare a current status of wooden architectural heritages. The result are as followings. Firstly, it was found the problems of a break, a damage, etc. in the platform and the problems of a cracking, an exfoliation, a corrosion, a warp, etc. in the wall. And, it was found a cracking of the beam(梁) and a roof tile(瓦), a falling of Angto(仰土), a sagging roof, etc. in the roof. Secondly, the damage causes of wooden architectural heritages were mostly caused by the physical limitations of the materials. And, it was caused by a rainwater, a subsidence of ground settlement, a destruction of waterproof membrane, etc. Lastly, the repair methods are making a quicklime layer in the soil mound on a cracking and an exfoliation part, a resin treatment or strut operation on a corrosion part of column, etc.