• Title/Summary/Keyword: arch structure

Search Result 279, Processing Time 0.022 seconds

Investigation of soil behaviour due to excavation below the grouped pile according to shape of tunnel station (터널 정거장 형상에 따른 군말뚝 하부 굴착 시 지반거동 연구)

  • Kong, Suk-Min;Oh, Dong-Wook;Lee, Jong-Hyen;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.1
    • /
    • pp.83-97
    • /
    • 2018
  • Tunnels are widely used for special purposes including roads, railways and culvert for power transmission, etc. Its cross-section shape is determined by uses, ground condition, environmental or economic factor. Many papers with respect to behaviours of adjacent ground and existing structure tunnelling-induced have been published by many researchers, but tunnel cross-section have rarely been considered. A collapse of tunnel causes vaster human and property damage than structures on the ground. Thus, it is very important to understand and analyse the relationship between behavoiurs of ground and cross-section type of tunnel. In this study, the behaviour of ground due to tunnel excavation for underground station below the grouped pile supported existing structure was analysed through laboratory model test using a trap-door device. Not only two cross-section types, 2-arch and box, as station for tunnel, but also, offset between tunnel and grouped pile centre (0.1B, 0.25B, 0.4B) are considered as variable of this study. In order to measure underground deformation tunnelling-induced, Close Range Photogrammetry technique was applied with laboratory model test, and results are compared to numerical analysis.

Restoration design of step-pool sequence in mountain streams (산지하천의 스텝-풀 연속체 복원설계)

  • Kim, Ki Heung
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.1
    • /
    • pp.29-43
    • /
    • 2020
  • The purpose of this study is to propose the design criteria and detailed design model by reviewing the issues related to geometry, formation process, destruction process, hydraulic function, restoration and ecological function of the step-pool from the existing research results, to apply the step-pool sequences to river restoration. Based on the analysis and review results, the design criteria for the structure and size of the step-pool are presented as ratio of the step spacing and the channel width, ratio of the unit step slope and channel slope, and ratio of step height and the particle size. To ensure structural stability of the step, stability analysis method of overturning based on the keystone theory was proposed as a design criterion. As a detailed design concept, a layout model was proposed by applying the imbricating structure of keystones and arch stones to the planar, longitudinal and transverse configurations of the step-pool.

Investigation of Adaptability of Smart Base Isolation System for Spacial Structures in Regions of Low-to-Moderate Seismicity (중약진지역 대공간 구조물에 대한 스마트 면진시스템의 적용성 검토)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.4
    • /
    • pp.109-119
    • /
    • 2011
  • To date, a smart base isolation system has been developed in high seismicity region such as Japan, USA etc. Smart base isolation systems developed for structures in high seismicity region cannot directly applied to structures in regions of low-to-moderate seismicity such as Korea. Therefore, problems that occur by applying the smart base isolation system developed for the structures in high seismicity region to the structures in regions of low-to-moderate seismicity have been investigated in this study. To this end, a spacial arch structure was used as an example structure and MR dampers and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes were used for ground motions in regions of high and low-to-moderate seismicity. Based on numerical simulation results, it has been known that the capacity of smart base isolation system for the regions of low-to-moderate seismicity should be carefully designed because the base isolation effects of the smart base isolation system for high seismicity region is deteriorated when it is applied to the structures in regions of low-to-moderate seismicity.

Analysis of Luminance distribution of Illuminated Bridges by View (조망의 변화에 따른 교량경관조명의 휘도특성분석)

  • Choi, Yoon-Seok;Jeong, In-Young;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.1-8
    • /
    • 2006
  • The study is to analyze the surface luminance of the illuminated bridges according to the change of view point using luminance measurements with instrument CS-100 and ProMetric 1400. For the purpose the illuminated bridges of the structure type were sleceted. Also, the view points were classified the three types which are a perspective view, a building view, a driver view. The luminance of the surrounding sky, surface of river, upper structure or bridge, girder side, and pier or the objects was measured. As a result of this study, The Kwangjin and Dongho Bridge showed the luminance distribution of a perspective view was high. And the Olympic and Dongjac bridge the luminance distribution of building view was high. The luminance effect of the girder bridge that has no upper structure was distinguished for the perspective view, and the cable-stayed girder bridge and the arch bridge were characterized as the building view.

A Study on the Optimal Design of TMD According to the Shape of Large Spatial Structures Part 2 (대공간 구조물의 형상에 따른 TMD 최적 설계에 관한 연구 Part 2)

  • Bae, Seok-Hong;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.83-91
    • /
    • 2020
  • In this study, a tuned mass damper(TMD) was installed to control the displacement response to earthquakes by generalizing to six analysis models according to the shape of the upper structure based on the case of various large spatial structures around the world. The six analysis models are ribbed type, latticed type, elliptical type, gable type, barrel type, and stadium type composed of 3D arch trusses. In this paper, ribbed type, latticed type and elliptical type were analyzed. The mass of each TMD was set to 1% of the total structural mass. Result of analyzing the optimal number and position of the analysis model, the displacement response control was the most excellent in the model with 6 and 8 TMDs, and the displacement response decreased in most cases. The displacement response control was better with installing the TMD at the edge point than focusing the TMD at the center of the analysis model. However, when 10 or more TMDs are installed or concentrated in the center, large loads intensively act on the structure, resulting in increased displacement. Therefore, although it is slightly different depending on the shape, it is judged that the displacement response control is the best to install 6 and 8 TMDs at the close to the edge point.

A Study on the Optimal Design of TMD According to the Shape of Large Spatial Structures Part 1 (대공간 구조물의 형상에 따른 TMD 최적 설계에 관한 연구 Part 1)

  • Bae, Seok-Hong;Lee, Young-Rak;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.4
    • /
    • pp.73-81
    • /
    • 2020
  • In this study, a tuned mass damper(TMD) was installed to control the displacement response to earthquakes by generalizing to six analysis models according to the shape of the upper structure based on the case of various large spatial structures around the world. The six analysis models are ribbed type, latticed type, elliptical type, gable type, barrel type, and stadium type composed of 3D arch trusses. In this paper, ribbed type, latticed type and elliptical type were analyzed. The mass of each TMD was set to 1% of the total structural mass. Result of analyzing the optimal number and position of the analysis model, the displacement response control was the most excellent in the model with 6 and 8 TMDs, and the displacement response decreased in most cases. The displacement response control was better with installing the TMD at the edge point than focusing the TMD at the center of the analysis model. However, when 10 or more TMDs are installed or concentrated in the center, large loads intensively act on the structure, resulting in increased displacement. Therefore, although it is slightly different depending on the shape, it is judged that the displacement response control is the best to install 6 and 8 TMDs at the close to the edge point.

A numerical study on feasibility of the circled fiber reinforced polymer (FRP) panel for a tunnel lining structure (터널 라이닝 구조체로서 곡면 섬유강화 복합재료의 적용성 검토를 위한 수치해석적 연구)

  • Lee, Gyu-Phil;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.6
    • /
    • pp.451-461
    • /
    • 2010
  • Utilization of the fiber reinforced polymer (FRP) material has been enlarged as a substitution material to the general construction materials having certain long-term problems such as corrosion, etc. However, it could be difficult to apply the FRP material, which has a linear shape generally, to an arch-shaped tunnel structure. Therefore, an attempt has been made in this study to develop a device to form a designed cross section of FRP material by pulling out with a curvature. A sample of the circled FRP product was successfully produced and then the sample has been tested to identify its physical characteristics. Then, intensive feasibility studies on the circled FRP panel to be used for a tunnel lining structure have been carried out by numerical analyses. As a result, it appears that the new circled FRP-concrete composite panel has a high capability to be used for a tunnel lining material without any structural problem.

Geophysical Exploration of Songsalli Ancient Tombs and Analysis of King Muryeong's Tomb Structure, Gongju (공주 송산리 고분군(公州 宋山里 古墳群)에서의 물리탐사와 무령왕릉(武寧王陵)의 구조분석)

  • Oh, Hyun-dok
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.4-23
    • /
    • 2013
  • Songsalli Ancient Tombs of Gongju consists of seven tombs. King Muryeong's tomb, the seventh tomb, is a brick chamber tomb discovered during the drainage works for the fifth and the sixth tombs in 1971. The excavation at the time focused on topographic surveys of the tomb entrance and the inside of the burial chamber as well as collection of the remains. The burial mount survey confirmed the status of some stone slab remaining and lime-mixed soil layers, but the survey did not examine the exterior structure of the whole tomb as the mounds were removed even more deeply. The excavation revealed damages to the bricks and mural damages due to moisture and fungus in the sixth and the seventh tombs. Between 1996 and 1997, Gongju National University conducted a comprehensive detailed survey of Songsalli Ancient Tombs including a geophysical survey, with an aim to identify the root causes of such degradation. Based on the results, repair took place in 1999 and the fifth, sixth and seventh tombs were placed under permanent conservation to conserve the cultural assets. General public is currently denied access. The purpose of this study was to conduct a three-dimensional resistivity and GPR surveys on the ground surface of the fifth, sixth and seventh tombs of Songsalli Ancient Tombs in order to understand the underground status after repair. The study also aimed to understand the thickness of all the tomb walls and exterior structure based on GPR inside King Muryeong's tomb. The exploration on the ground surface found that the three tombs and soil adjacent to the tombs had resistivity as low as 5 to $90{\Omega}m$, which confirmed that the soil water content was still as high as that prior to the repair work. Additionally, GPR found that the wall construction of the burial chamber of King Muryeong's tomb was approximately 70cm in thickness, while the structure was of 2B with two bricks, about 35cm in length, put together longitudinally(2B brick masonry). The pathway to the burial chamber was of the 2B structure just like that of the burial chamber walls, while its thickness was 80cm with an eyebrow-type arch connected to it. Also, the ceiling exterior appears to have an arch structure, identical to the shape inside.

A CASE OF SURGICAL TREATMENT FOR SYMPTOMATIC ELONGATED STYLOID PROCESS (이상경상돌기증의 치험례)

  • Kim, Chang-Hwan;Kim, Eun-Goan;Park, Hyo-Sang;Park, No-Boo;Lee, Yong-Oh
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.16 no.3
    • /
    • pp.348-355
    • /
    • 1994
  • Styloid process is a slender pointed bone of variable length, which project downward, forward, and slightly medialward from the posteroinferior portion of the tympanic part of the temporal bone. Embryologically, the styloid process is derived from Reichert's cartilage, a structure of second branchial arch origin. Most patients with elongated styloid process remain asymptomatic, but some patients complain pain and sensation of foreign body in the throat, dysphagia, dysphonia, referred otalgia. Recently, we have experienced a case of elongated styloid process in a fifty-nine year old man. He had been suffered from Rt. side sore throat, headache and pharyngeal discomfort during head movement. Through various X-ray examination, Xeroradiography, and palpation of tonsillar fossa, elongated styloid process on Rt. side was confirmed. Under the general anesthesia, it was successfully removed out via transoral approach technique, described by Eagle. The resected styloid process was 2.5cm in it's length and he was freed from the symptoms without further complication.

  • PDF

Computer Analysis of Non-vaulted Nef Unique System

  • Hong, Seong-Woo
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Ever since Viollet-le-Due began to examine Gothic structural elements using his method of geometrical analysis in the nineteenth century, art and architectural historians and a few engineers have periodically attempted to ascertain the structural advantages of the various characteristic features of Gothic architecture. In none of these studies, however, has the way forces work within the lightweight and spacious masonry Gothic buildings been precisely interpreted. The approach taken by art and architectural historians has therefore tended to be primarily descriptive and to be based on intuitive assumptions. This study intend to analyze the Gothic non-vaulted nef unique(aisleless) structures of Lower Languedoc which has never been scientifically tested, and to provide as comprehensive an explanation as possible of the way in which these non-vaulted buildings work. In order to achieve this goal, this paper Is to examine, by means of finite element analysis. the links between the width of non-vaulted aisleless structures, the configuration of the arches, diaphragm arch, and the buttress. Finite element analysis with a computer provides a more accurate analysis than the methods of analysis that have been heretofore applied to Gothic structures, as well as permits us to visualize the global stress behavior of the structure. Combined with traditional methods of studying historical buildings, therefore, finite element analysis inevitably give us a broader understanding of the processes involved in the design and construction of medieval buildings.

  • PDF