• Title/Summary/Keyword: arc velocity

Search Result 126, Processing Time 0.04 seconds

Analysis of Trail-Edge Noise from Sirocco Fans (시로코 홴 날개후단 소음예측)

  • Kim, Kyoung-Ho;Lee, Seung-Bae;Kim, Ji-Sung;Kwon, Yang-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.396-401
    • /
    • 2000
  • It is addressed that the turbulent broadband sound power from a sirocco fan can be modeled by the trailing edge noise. The trailing edge noise is usually influenced by inflow turbulence, separation, and boundary layer on the blade. The design parameters such as solidity(c/s) and stagger angle are specified to predict performance and noise level because the separation and slip velocity are strongly affected by them along with the flow coefficient. This paper reports the effects of the solidity and the stagger angle upon the trailing edge noise from the circular arc-shaped blade of sirocco fan.

  • PDF

An Investigation on the Formation Characteristics of a Single Vortex Interacting with Counterflow Nonpremixed Flame (대향류 비예혼합화염과 상호작용하는 단일 와동의 생성특성에 관한 연구)

  • Yoo, Byung-Hun;Oh, Chang-Bo;Hwang, Chul-Hong;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.49-56
    • /
    • 2002
  • A two-dimensional direct numerical simulation is performed to investigate the formation characteristics of a single vortex interacting with $CH_4/N_2$-Air counterflow nonpremixed flame. The numerical method was based on a predictor-corrector scheme for a low Mach number flow. The detailed transport properties and a 16-step augmented reduced mechanism are adopted in this calculation. The budgets of the vorticity transport equation arc examined to reveal the mechanisms leading to the formation, evolution and dissipation of a single vortex interacting with counterflow nonpremixed flame. It is found that the stretching term, which depends on the azimuthal component of vorticity, and radial velocity, mainly generates vortieitv in non-reacting and reacting flows. The viscous and baroclinic torque term destroy the vorticity in non-reacting flow. In addition, the baroclinic torque term due to density and pressure gradient generates vorticity, while viscous and the volumetric expansion terms due to density gradient destroy vorticity in reacting flow.

  • PDF

A Study of Heat and Fluid Flow for GMA Welding Processes (GMA 용접 공정 중 열 유체에 관한 연구)

  • 김일수;박창언;권욱현;김수광
    • Proceedings of the KWS Conference
    • /
    • 1996.10a
    • /
    • pp.148-152
    • /
    • 1996
  • A transient two-dimensional (2D) model was developed for investigating the heat and fluid flow in old pools and determining velocity profile and temperature distribution for the Gas Metal Arc (GMA) welding process. The mathematical formulation deals with the driving farces (electromagnetic, buoyancy, surface tension and plasma drag forces) as well as energy exchange between the molten filler metal droplet and weld pools. A general thermofluid-mechanics computer program, PHOENICS, was employed to numerically solve the governing equation with the associated source terms. The results of computation have shown that the electromagnetic and surface tension farces as will as the molten filler metal droplet have major influence in shaping the weld pool geometry.

  • PDF

Study on the Surface Coating of CrN for Erosion in Liquid water Drop Test

  • Kwon, Sik-Chol;Baek, W-S;Lee, S-H;Kim, K-H;Kim, H-H
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.63-63
    • /
    • 2001
  • As a new approach to substitute for a hard alloy of stellite 6B containing Co which is radioactive in nuclear system, a hard-phase coating of CrN will be applicable to protect 12Cr steel from erosion at leading edge on steam turbine blade. The CrN coating was prepared by arc ion plating on 12 Cr steel and was undertaken in liquid impact test at the velocity of 35Om/sec, which simulate the environment in the last stage of blade. The erosion resistance of coating was evaluated by optical observation on damaged surface. The threshold number of impact was closely related with surface hardness. And thus, it was confirmed that surface hardening improves the life time of steam turbine blade.

  • PDF

Temperature Analysis of the De-icing System for Overhead Contact Wire (전차선로 해빙시스템의 온도특성)

  • Ko, Byeong-Hun;Park, Young;Jung, Ho-Sung;Kwon, Sam-Young;Park, Hyun-June
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.1004-1008
    • /
    • 2007
  • The ice coats are built on 25 kV overhead contact wire when the temperature is lower than $0^{\circ}C$. It generates shockwaves at the mechanical interface of the collecting strips of the pantograph and the contact wire. The de-icing processes should be performed to avoid shockwaves which are generated by a pulsed high-voltage arc discharge. This paper presents temperature analysis of the de-icing effects which could be applied to the overhead contact wire of railways using Joule heat. The results show that 350 A is the proper current for $0^{\circ}C$ conductor according to environmental condition such as velocity of air stream, ambient temperature and moisture.

Correlation between Welding Parameters and Detaching Drop Size using Regression (회귀 분석을 이용한 용접 변수와 이탈 액적 크기의 상호 관계)

  • 최상균;한창우;이상룡;이영문
    • Journal of Welding and Joining
    • /
    • v.20 no.1
    • /
    • pp.83-90
    • /
    • 2002
  • Metal Transfer in gas metal arc (GMA) welding is a complex phenomenon affected by many parameters of the welding conditions and material properties. In this research, the correlation equation between the welding condition and detaching droplet size and detaching velocity in GMA welding was studied via recession analysis on the results of numerical analysis using the volume-of-fluid (VOF) method. Welding parameters and material properties were grouped into three dimensionless numbers and detaching droplet size was expressed as the function of them. Second order and exponential multi-variable correlation forms were assumed, and the coefficients of these equations were calculated for globular and spray modes as well as entire transfer modes. Applying correlation equation into available experimental data, it shows good agreement.

Sliding Wear and Corrosion Resistance of Copper-based Overhead Catenary for Traction Systems

  • Kwok, C.T.;Wong, P.K.;Man, H.C.;Cheng, F.T.
    • International Journal of Railway
    • /
    • v.3 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • In the present study, the electrical sliding wear and corrosion resistance of pure copper (Cu) and six age-hardened copper alloys (CuCr, CuZr, CuCrZr, CuNiSiCr, CuBe and CuBeNi) were investigated by a pin-on-disc tribometer and electrochemical measurement. Various copper-based alloys in the form of cylindrical pin were forced to slide against a counterface stainless steel disc in air under unlubricated condition at a sliding velocity of 31 km/h under normal load up to 20 N with and without electric current. The worn surface of and wear debris from the specimens were studied by scanning electron microscopy. Both mechanical wear and electrical arc erosion were the wear mechanisms for the alloys worn at 50 A. Owing to its good electrical conductivity, high wear and corrosion resistance, CuCrZr is a promising candidate as the overhead catenary material for electric traction systems.

  • PDF

Performance Analysis of the KOMPSAT-1 Orbit Determination Using GPS Navigation Solutions (GPS 항행해를 이용한 아리랑 1호의 궤도결정 성능분석 연구)

  • Kim, Hae-Dong;Choi, Hae-Jin;Kim, Eun-Kyou
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.43-52
    • /
    • 2004
  • In this paper, the performance of the KOMPSAT-1 orbit determination (OD) accuracy at the ground station was analyzed by using the flight data. The Bayesian least squares estimation was used for the orbit determination and the assessment of the orbit accuracy was evaluated based on orbit overlap comparisons. We also compared the result from OD using GPS navigation solutions with NORAD TLE and the result from OD using range data. Furthermore, the effect of observation type and OBT drift on the accuracy was investigated. As a consequence, It is shown that the OD accuracy using only GPS position data is on the order of 5m RMS (Root Mean Square) with 4 hrs arc overlap for the 30hr arc and the GPS velocity data is not proper as a observation for the OD due to its inferior quality. The significant deterioration of the accuracy due to the critical clock bias was not founded by means of the comparison of OD result from other observations.

Numerical Analysis on Cascade Performance of Double-Circular-Arc Hydrofoil (수치 모사를 통한 이중원호 익렬의 성능 예측)

  • Jeong, Myeong-Gyun;O, Jae-Min;Paeng, Gi-Seok;Song, Jae-Uk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.432-438
    • /
    • 2002
  • In order to design and analyze the performance of an axial-flow pump it is necessary to know the flow deviation, deflection angle and pressure loss coefficient as a function of the angle of incidence for the hydrofoil section in use. Because such functions are unique to the particular section, however, general correlation formulae are not available for the multitude of hydrofoil profiles, and such functions must be generated by either experiment or numerical simulation for the given or selected hydrofoil section. The purpose of present study is to generate design correlations for hydrofoils with double circular arc (DCA) camber by numerical analysis using a commercial code, FLUENT. The cascade configuration is determined by a combination of the inlet blade angle, blade thickness, camber angle, and cascade solidity, and a total of 90 cascade configurations are analyzed in this study. The inlet Reynolds number based on the chord and the inlet absolute velocity is fixed at 5${\times}$10$\^$5/. Design correlations are formulated, based on the data at the incidence angle of minimum total pressure loss. The correlations obtained in this way show good agreement with the experiment data collected at NASA with DCA hydrofoils.

Estimating Method of Topographic Factor of Design Wind Speed Using GIS (GIS를 이용한 지형에 의한 풍속할증계수 산정 방법)

  • Choi, Se-Hyu;Seo, Eun-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.3
    • /
    • pp.126-135
    • /
    • 2013
  • With more than 70% of the country consisting of mountains, Korea has large and small mountains, and hills located in the inner cities. Therefore, Korea's architectural structure laws stipulate that an increase in wind speed due to the influence of terrain should be considered in the design of wind loads of buildings. But if more than two mountains are located around the building or if the boundaries of the land surface are not clear when calculating topographic factors of wind speed, the designer has subjectively selected the coverage of the topographic factors of wind speed or the surface. This may lead to unscientific design of wind loads. This study attempts to analyze topographic factors of wind speed by using a 1:5000 topographic map with relatively high location accuracy and thereby to reflect changes due to the topographic characteristics and influence at the point where the building is located. By also selecting terrain surfaces and vertexes through Arc GIS and presenting a scientific approach to determine the range of topographic factors of wind speed, this study is expected to make a contribution for more rational and cost-effective wind-resistant design of buildings.