• 제목/요약/키워드: arc time

검색결과 883건 처리시간 0.023초

220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석 (Analysis of Ignition Time/Current Characteristics and Energy when Series Arc-Fault Occurs at Rated 220 V)

  • 고원식;문원식;방선배;김재철
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1184-1191
    • /
    • 2013
  • Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.

스패터 양을 이용한 아크 안정성 판별에 관한 연구 (A study on determining arc stability using weight of spatter)

  • 강성구;문형순;나석주
    • Journal of Welding and Joining
    • /
    • 제15권6호
    • /
    • pp.41-48
    • /
    • 1997
  • For analyzing the characteristics of arc welding processes, an algorithm is necessary to determine the metal transfer mode, arc stability and weld quality. In this study, the weight of spatter during welding was selected for determining the arc stability, which is very relevant to the occurrence of spatter. Weld spatter occurs mainly at the moment when the short circuit is formed and also when it is broken causing the arc to restrike. Based on this fact, the arc stability can be determined by finding the suitable parameters of welding current and arc voltage which influence the weight of spatter. Through various welding experiments, the peak current, the arcing time, the short circuit time, the current and its slope at the start of short circuit were found mainly to influence the weight of spatter. For the convenient usage, an index was proposed by combining all these parameters. It was found that the index is very effective for determining the arc stability.

  • PDF

교류 피복 아크 용접에 있어서 아크 안정성의 정량적 평가에 관한 연구 (A Study on the Quantitative Evaluation of Arc Stability in AC SMAW)

    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.125-135
    • /
    • 1998
  • The shielded metal arc welding (SMAW) by AC power source was performed to evaluate the arc stability by arc monitoring and analysing. In this study, the arc stability index was evaluated quantitatively by using he coefficient of resistance variation for welding time. This coefficient was obtained for the long time (20sec.) by analysing the waveforms of welding current, voltage and resistance. The coefficient was applied to indicate numerically the variation level of arc length and the degree of arc extinction. Using the coefficient of resistance variation in practical welding, the arc stability of the high titanium oxide electrode (KS E4313) turned out to be better than that of the low hydrogen electrode (KS E4316). In evaluating the skill level of welders by the coefficient, the horizontal fillet weaving welding became clear to be very discriminating because the higher level welder could weave in keeping constant arc length, but the lower level welder showed the characteristics of weaving with the unstable arc length. And it was confirmed that the welding defects as blow holes was formed when the arc stability index were high.

  • PDF

DC Arc Extinction Using External Magnetic Field in Switching Device

  • Cho Hyun-Kil;Lee Eun-Woong;Jeong Jong-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.306-311
    • /
    • 2005
  • In this paper, the electromagnetic force acting in the arc column of 3 different extinction units is compared with using the FEM (Finite Element Method) and the arc velocity is calculated by the drag force of the fluid mechanics. The experiment for breaking the arc current was performed in each model at 100 volts in order to measure the arcing time. The outcome was compared with the computing value. As a result, this paper proposes that the divided U-shaped grid is able to shorten arcing time and improve the electric performance. It also suggests a methodology for comparing and analyzing the result obtained by simulation and experiment.

직류 아크 소호실의 자기회로에 따른 아크 자기 구동력 해석 (The Analysis of Magnetic driving force depending on Magnetic Flux-path in DC Arc-quenching chamber)

  • 조현길;이은웅;임수생;이화수;서정민;김견묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.12-14
    • /
    • 2002
  • In this paper, magnetic force on acting arc was analyzed by 3-D FEM for three DC arc-quenching rooms having different magnetic flux paths. We measured arc breaking time in prototypes by experiment so that we compared the relation of magnetic force and arc breaking time. Finally, we present the techniques for magnetically-driven arc and for the prediction of arc breaking time.

  • PDF

직류 아크 소호 시간을 단축시키는 직교자계의 영향 (The Influence of Transverse Magnetic Field for Shortening DC Arc Time)

  • 이은웅;조현길
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권3호
    • /
    • pp.146-154
    • /
    • 2006
  • We derived a theory of increasing electromagnetic force which acts on arc column for reducing arcing time between electric contacts. A simulation method of arc velocity is presented by calculating blowout force using 3D FEM and drag force acting on arc column. This paper proposes 3 types arc extinguish chamber of different flux path and presents the specific electromagnetic force and arc velocity of each model by the analysis. The result of analysis and experimental proposes the prediction method of arc time when all conditions are same except external magnetic field.

765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책 (The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection)

  • 안상필;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

소모성 전극을 사용하는 아크용접 로봇을 위한 아크센서 개발에 관한 연구 (A Study on Development of Arc Sensor for Arc Welding Robot Using Consumable Electrode)

  • 이승영;문형순;나석주;장영주;안병규
    • Journal of Welding and Joining
    • /
    • 제11권3호
    • /
    • pp.22-33
    • /
    • 1993
  • Arc sensor is indispensable to arc welding robot systems for compensating the joint misalignment such as mismatch of the workpiece, ill-conditioned positioner and thermal deformation during welding. Furthermore, the amount of these mismatches cannot be preivously expected, and changes from time to time. There are many kinds of seam trackers for correcting the welding path of the robot, where non-contact type sensors arc prevalently used in arc welding robot systems. In this study, an arc sensor was developed for GMA and FCA welding robot system. Since the arc sensor uses the arc characteristics during welding, the operating principle of the arc sensor must be adjusted according to the welding condition. Especially in GMA welding with the $CO_{2}$ shielding gas, the welding arc is not stable because of the short circuit and non-axial globular transfer mode of the molten droplet. In this study, the 2nd order least square curve fitting algorithm was adopted and the applicability of this algorithm was investigated for robot welding systems. For easy usage of the arc sensor, the operating parameters for arc sensor were limited to eight which can be easily determined by the operator.

  • PDF

서보 모터의 가감속을 고려한 2.3차원 원호의 실시간 직선 보간 (Real-time Line Interpolation of a 2.3D Circular Arc based on the Acceleration and Deceleration of a Servo Motor)

  • 이제필;이철
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.399-404
    • /
    • 2001
  • In CNC machining, a 3D(3-dimension) linear segment and a 2D(2-dimension) circular arc are general forms given by CAD/CAM system. Generally, the 2D circular arc machining is processed using dividing into some linear segments. A 3D circular arc also don't exist in the standard form of NC data. This paper present a algorithm and method for real-time machining of a circular arc(not only the 2D one, but also the 3D one). The 3D circular arc machining is based on the 2D circular arc machining. It only needs making a new coordinate system, converting given 3D points(a start point, a end point, and a center point of a 3D circular arc) into points of the new coordinate system, and processing a inverse transformation about a interpolated point. The proposed algorithm was implemented and simulated on PC system. It was confirmed to give a gcod result.

  • PDF

단상 재폐로시 2차아아크 전류의 감소방법에 관한 연구 (A Study on the Decreasing Method of Secondary Arc Current on Single Phase Reclosing)

  • 김준현
    • 전기의세계
    • /
    • 제26권6호
    • /
    • pp.59-65
    • /
    • 1977
  • A study on the decreasing method of secondary arc current on single phase reclosing. One of the major problem in case of using the single phase reclosing scheme for long distance UHV transmission line is the time required to deionize secondary arc current. This paper descritbes the way of inducing the formular of secondary arc current originated at the times of opening and closing the ground interrupting switch. The result was investigated by the method of numerical analysis and proved that the secondary arc current was decreasing sufficiently. Application of this method proposed by the authod makes it possible to deduce the dead time and to improve success-rate of reclosing.

  • PDF