• 제목/요약/키워드: arc measure

검색결과 124건 처리시간 0.026초

STUDY ON MONITORING UNIT EFFICIENCY OF FLATTENING-FILTER FREE PHOTON BEAM IN ASSOCIATION WITH TUMOR SIZE AND LOCATION

  • Kim, Dae Il;Kim, Jung-In;Yoo, Sook Hyun;Park, Jong Min
    • Journal of Radiation Protection and Research
    • /
    • 제38권4호
    • /
    • pp.194-201
    • /
    • 2013
  • To investigate monitoring unit (MU) efficiency and plan quality of volumetric modulated arc therapy (VMAT) using flattening-filter free (FFF) photon beam in association with target size and location. A virtual patient was generated in Eclipse$^{TM}$ (ver. A10, Varian Medical Systems, Palo Alto, USA) treatment planning system. The length of major and minor axis in axial view was 50 cm and 30 cm, respectively. Cylindrical-shaped targets were generated inside that patient at the center (symmetric target) and in the periphery (asymmetric target, 7.5 cm away from the center of the patient to the right direction) of the virtual patient. The longitudinal length was 10 cm and the diameters were 2, 5, 10 and 15 cm. Total 8 targets were generated. RapidArc$^{TM}$ plans using TrueBeam STx$^{TM}$ were generated for each target. Two full arcs were used and the axis of rotation of the gantry was set to be at the center of the virtual patient. Total MU, homogeneity index (HI), target mean dose, the value of gradient measure and body mean dose were calculated. In the case of symmetric targets, averaged total MU of FFF plan was 23% and 19% higher than that of flattening filter (FF) plan when using 6 MV and 10 MV photons, respectively. The difference of HI, target mean dose, gradient measure and body mean dose between FF and FFF was less than 0.04, 2.6%, 0.1 cm and 2.2%, respectively. For the asymmetric targets, total MU of FFF plan was 21% and 32% was higher than that of FF when using 6 MV and 10 MV photons, respectively. The homogeneity of the target was always worse when using FFF than using FF. The maximum difference of HI was 0.22. The target mean dose of FFF was 3.2% and 4.1% higher than that of FF for the 6 MV and 10 MV, respectively. The difference of gradient measure was less than 0.1 cm. The body mean dose was higher when using FFF than FF about 4.2% and 2.8% for the 6 MV and 10 MV, respectively. No significant differences between VMAT plans of FFF beam and FF beam were observed in terms of quality of treatment plan. The HI was higher when using FFF 10 MV photons for the asymmetric targets. The MU was increased noticeably when using FFF photon beams.

HARMONIC DOUBLING CONDITION AND JOHN DISKS

  • Kim, Ki-Won
    • 대한수학회논문집
    • /
    • 제10권1호
    • /
    • pp.145-153
    • /
    • 1995
  • A Jordan domain D in C is said to be a c-quasidisk if there exists a constant $c \geq 1$ such that each two points $z_1$ and $z_2$ in D can be joined by an arc $\tau$ in D such that $$ \ell(\tau) \leq c$\mid$z_1 - z_2$\mid$ $$ and $$ (1.1) min(\ell(\tau_1),\ell(\tau_2)) \leq c d(z, \partial D) $$ for all $z \in \tau$, where $\tau_1$ and $\tau_2$ are the components of $\tau\{z}$. Quasidisks have been extensively studied and can be characterized in many different ways [1],[2],[3].

  • PDF

Effect of light source on depth of cure and polymerization shrinkage of composites

  • Na, Joon-Sok;Oh, Won-Mann;Hwang, In-Nam
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.578.1-578
    • /
    • 2001
  • The aim of this study was to evaluate the efficiency of the recently introduced light curing units to polymerize a light curing resin composite. Four light curing units XL 3000, Optilux 500 for halogen light source, Apollo 95E for plasma arc and Easy cure for LED (blue-light Emitting Diode) were evaluated. Radiometer was used for measure the light intensity.(omitted)

  • PDF

고속 이미지 분석에 의한 전차선로 계측 (Overhead Catenary Measurement by High-speed Image Analysis)

  • 박영;이기원;조용현;권삼영;박찬배;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.824-828
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed and used in with high-speed analysis and advanced image processing techniques. This study utilizes a high-speed camera as inspecting system to measure the wear, stagger, hight and arc extinguishing test of overhead catenary system. All measuring image were captured by a high speed CMOS camera with PCI express output, which can acquire up to 1000 frames per second with the resolution 1024 × 1280 pixels. Line type laser source with a power equal to 300 mW and the National Instrument LabVIEW (8.0) based on vision acquisition software have been used in application programming interface for image acquisition, display, and storage. The proposed high-speed camera system is finally applied to measure the overhead catenary system showing promising on-field applications

  • PDF

Exact Asymptotics in a Multi-class M/G/1 Queue

  • 이지연
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 한국데이터정보과학회 2006년도 PROCEEDINGS OF JOINT CONFERENCEOF KDISS AND KDAS
    • /
    • pp.43-47
    • /
    • 2006
  • Consider a multitype queue where queued customers arc served in their order of arrival at a rate which depends on the customer type. Here we calculate the sharp asymptotics of the probability the total number of customers in the queue reaches a high level before emptying. The natural state space to describe this queue is a tree whose branches increase in length as the number of customers in the queue grows. Consequently it is difficult to prove a large deviation principle. Moreover, since service rates depend on the customer type the stationary distribution is not of product form so there is no simple expression for the stationary distribution. Instead, we use a change of measure technique which increases the arrival rate of customers and decreases the departure rate thus making large deviations common.

  • PDF

필드 밀을 이용한 대지전장 측정장치 개발 (Development of Measuring Device for Electric Field on the Ground Level Using a Field Mill)

  • 송재용;김명진;길경석;천상규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.469-473
    • /
    • 2001
  • This paper describes a rotation-type field mill to measure the electric field intensity caused by thunderclouds on the ground level. The field mill developed is consisted of two isolated electrode vanes, a grounded stator and a rotor. To develop a high sensitive field mill, the principles and design rules of a rotation-type field mill are studied. Also, two types of calibration system, such as a cylindrical guard electrodes and a parallel-plate electrodes, are proposed to determine the sensitivity and frequency bandwidth of the field mill. From the calibration experiment, the frequency bandwidth and the sensitivity of the field mill arc DC ∼ 200 [MHz] and 0.267 [mV/Vm], respectively. Therefore, it can measure the electric field intensity from 73[V/m] to 18.7[kV/m].

  • PDF

천연물 유래 산조인 복합오일 (Zizyphus jujuba var. spinosa Composite oil, ZjJ-C_oil) 및 독활 복합오일 (Aralia cordata var. continentalis Composite oil, ARC-C_oil)의 DNCB로 유도된 NC/Nga 생쥐의 아토피에 미치는 효과 연구 (Anti-atopic Effect of Zizyphus jujuba var. spinosa Composite oil(ZjJ-C_oil) and Aralia cordata var. continentalis Composite oil(ARC-C_oil) in DNCB-induced Atopic Dermatitis-like Skin Lesions NC/Nga Mice)

  • 곽진영;최희정;박정미;박정환;고영미;장태수;안택원
    • 사상체질의학회지
    • /
    • 제29권4호
    • /
    • pp.347-368
    • /
    • 2017
  • The aim of this study is to investigate the effect of Zizyphus jujuba var. spinosa Composite oil(ZjJ-C_oil) and Aralia cordata var. continentalis Composite oil(ARC-C_oil) to NC/Nga mice induced in Atopic dermatitis-like skin lesions by DNCB. NC/Nga mice which have been induced to Atopic dermatitis-like skin lesions by DNCB are divided into 4 groups, the first is the mice which have been spread with izyphus jujuba var. spinosa Composite oil(ZjJ-C_oil), the second is the mice which have been spread with Aralia cordata var. continentalis Composite oil(ARC-C_oil), the third is which have been spread with dexamethasone (Dexa.) 0.5% on their Atopic lesion, the last is the control group. Then We analyzed skin clinical score, blood sample of each group of measure state of the dorsal skin, the number of immunocytes, and resect the skin lesion to anlayze the state of cells. There are meaningful results of measuring the number of IgE, IL-4, IL-13, $IFN-{\gamma}$, IL-5, the total cells in ALN, dorsal skin, CD4+ Th, CD11b+/Gr-1+ in PBMCs, CD4+ Th, B220+/CD23+ in ALN, $CD4^+$, $CD8^+$ Th in dorsal skin, the level of COX-2, $TNF-{\alpha}$, $TGF-{\beta}1$, IL-4, IL-13 mRNA, the state of the skin lesion and cells in the group with ZjJ-C_oil, ARC-C_oil cream in comprarison with the control group.

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Journal of Audiology & Otology
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.