• Title/Summary/Keyword: aqueous ozone

Search Result 56, Processing Time 0.026 seconds

Degradation of Humic Acids by Ozone/high pH, Ozone/Hydrogen Peroxide and Ozone/Hydrogen Carbonate System ($O_3$/high pH, $O_3/H_2O_2$$O_3/{HCO_3}^-$ 시스템에서의 부식산의 분해 반응 특성)

  • Shin, Hyun Sang;Kim, Kei Woul;Rhee, Dong Seok
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.652-658
    • /
    • 2000
  • Chemical degradation of aqueous humic acid by ozonation was studied with respect to the direct reactions of ozone and the indirect reactions due to its preliminary decomposition to secondary oxidant, OH radical. This was characterized by analyzing TOC, $UV_{254}$ and ozone consumption measured in different experimental conditions in which ozone reacted in the presence of various concentrations of $H_2O_2$ and $HCO_3{^-}$ concentrations ranging from 20 to 100 mg/L. and different pH (5-9). The results suggest that the TOC removal is mainly dependent on indirect reactions of OH radical whereas $UV_{254}$ reduction is mainly dependent on direct reactions of ozone with humic acid molecules. It has been also found that ozone consumption was most likely to be affected by pH and alkalinity in the solution.

  • PDF

ORGANIC POLLUTANTS DEGRADATION USING PULSELESS CORONA DISCHARGE: APPLICATION IN ULTRAPURE WATER PRODUCTION

  • Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.144-154
    • /
    • 2005
  • The use of ozone gained acceptance in the production of ultrapure water because of its powerful oxidizing ability. Ozone is currently used to deactivate microorganisms and remove organic contaminants. However, interest also exists in using radical species, which arc stronger oxidants than ozone, in such processes. One means of producing radical species is by corona discharge. This work investigates the use of a novel pulseless corona-discharge system for the removal of organic substances in ultrapure water production. The method combines corona discharge with electrohydrodynamic spraying of oxygen, forming microbubbles. Experimental results show that pulseless corona discharge effectively removes organics, such as phenol and methylene blue, in deionized water. The corona-discharge method is demonstrated to be comparable to the direct use of ozone at a high-applied voltage. The results also show that a minimum applied voltage exists for operation of the corona-discharge method. In this work, the minimum applied voltage is approximately 4.5 kV. The kinetic rate or phenol degradation in the reactor is modeled. Modeling results show that the dominant species of the pulseless corona-discharge reactor are hydroxyl radical and aqueous electron. Several radical species produced in the pulseless corona-discharge process are identified experimentally. The. major species are hydroxyl radical, atomic hydrogen species, and ozone.

Effect on the Hydrogen Peroxide in the Ozonation of Ammonia (오존에 의한 암모니아 산화시 과산화수소가 미치는 영향)

  • 박문숙;안재동;노봉오
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Ammonia is used in the manufacture of fertilizers, refrigerants, stabilizers and many household cleaning agents. These wide applications resulted in ammonia contamination in water. Ammonia can be removed from water by physical, biological, and chemical methods. Ozonation is effictive in the treatment of water with low concentration of ammonia. This study is undertaken to provide kinetic data for the ozonation of ammonia with or without hydrogen peroxide. The results were as follows; The destruction rate of ammonia increased gradually with the influent hydrogen peroxide concentration up to 0.23 mM and inhibited in the range of 0.23~11.4mM, and the maximum removal rate of ammonia achieved at 0.23mM of hydrogen peroxide, and the overall kinetics was first order. The combination effect of hydrogen and ozone to oxide ammonia in aqueous solution was better than ozone alone. The reacted ammonia was converted completely to nitrate ion.

  • PDF

One-side Water-repellent Finish of PET Fabrics using UV/Ozone (UV/Ozone 조사에 의한 PET 직물의 편면 발수가공)

  • Kim, Su-Jin;Jang, Jin-Ho
    • Textile Coloration and Finishing
    • /
    • v.23 no.2
    • /
    • pp.100-106
    • /
    • 2011
  • UV-curable water-repellent finish was carried out to impart one-side repellency to the PET fabrics using a formulation of a UV-active fluorocarbon agent and a water soluble photoinitiator. The aqueous formulation was padded on the PET fabrics and it was subsequently UV-cured. The unirradiated side of the cured fabrics was made to wetteable to water by the prolonged UV/ozone irradiation. The influence of photoinitiator concentration, agent concentration and UV energy for photodegradation on the performance of the finished fabrics were investigated. The difference in the functional property of front and back sides was examined by measuring water repellency at each side of the treated fabrics, which resulted in four rating difference between two-side. The UV-cured and photodegraded PET surfaces were characterized by ATR, ESCA and FE-SEM.

Treatment of Aqueous Phenol by H2O2 and O3/UV (H2O2와 O3/UV를 이용한 페놀용액의 처리)

  • Shin, Jin Hwan;Jeoung, Young Do;Yeon, Ik jun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.251-255
    • /
    • 2004
  • Laboratory experiments were performed to investigate oxidation system using ozone and hydrogen peroxide for treating water contaminated with phenol. We were able to greatly improve the oxidation efficiency of the aqueous phenol using hydrogen peroxide and ozone. Two methods were compared and analyzed in this study. In the consequence through the methods, we concluded that the $O_3/UV$ is superior to the hydrogen the results. The decomposition efficiency of aqueous phenol by $H_2O_2$. was exceeded at 83.3% in the concentration of phenol, 5, 15, 25 ppm, respectively. The rate of decomposition reaction by $H_2O_2$. was very slow. In the occasion of the fractional life, it was determined the value that $1.61{\times}10^{-5}(l/mol)^{1.172}sec^{-1}$, $3.75{\times}10^{-5}(l/mol)^{0.792}sec^{-1}$, $4.11{\times}10^{-5}(l/mol)^{1.782}sec^{-1}$. The rate of decomposition reaction of aqueous phenol by $O_3$ was fast compared to the $H_2O_2$. We concluded that the $O_3$ method is useful with the consideration of the reaction time 30 minutes. In the occasion of the fractional life, it was determined the value that $1.094{\times}10^{-4}(l/mol)^{0.933}sec^{-1}$, $2.1{\times}10^{-4}(l/mol)^{0.842}sec^{-1}$, $7.22{\times}10^{-4}(l/mol)^{1.332}sec^{-1}$.

Applications of Ozone Micro- and Nanobubble Technologies in Water and Wastewater Treatment: Review (정수 및 폐수처리에서 오존 미세기포와 초미세기포 기술의 적용 : 리뷰)

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.481-490
    • /
    • 2017
  • Water and wastewater treatment has always been a challenging task due to the continuous increase in amount and the change in characteristics of the poorly biodegradable and highly colored organic matters, as well as harmful micro-organisms. Advanced techniques are therefore required to successfully remove these pollutants from water before reuse or discharge to receiving water bodies. Application of ozone, which is a powerful oxidant and disinfectant, alone or as part of advanced oxidation process depends on the complex kinetic reactions and the mass transfer of ozone involved. Micro- and nano bubbling considerably improves gas dissolution compared to conventional bubbles and hence mass transfer. It can also intensify generation of hydroxyl radical due to collapse of the bubbles, which in turn facilitates oxidation reaction under both alkaline as well as acidic conditions. This review gives the overview of application of micro- and nano bubble ozonation for purification of water and wastewater. The drawbacks of previously considered techniques and the application of the hydrodynamic ozonation to synthetic aqueous solutions and various industrial wastewaters are systematically reviewed.

Formation of Hydrogen Peroxide by the Ozonation of Aqueous Humic Acid (수중 부식산의 오존처리시 생성되는 과산화수소의 농도 변화에 대한 연구)

  • Kim, Kei Woul;Rhee, Dong Seok
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.659-665
    • /
    • 2000
  • The changes in $UV_{254}$ and concentrations of $H_2O_2$ formed by ozonation of aqueous humic acid in ozone/high pH, peroxone process and in the presence of radical scavenger, $HCO_3{^-}$ were investigated. This study confirmed that the formation of $H_2O_2$ by ozonation may undergo different reaction pathways compared to those of $UV_{254}$ reduction in the degradation of the humic acid. The concentration of $H_2O_2$ produced by ozonation was found to be increased with decreasing pH of the sample solution due to the higher stability of ozone molecules at acidic conditions. On the while, $UV_{254}$ reduction was found to be higher at alkaline conditions or larger amount of $H_2O_2$ additions as a radical promoter in which the producing of ${\cdot}OH$, ${\cdot}HO_2$ radicals can be more favorable. From the results, it has been suggested that the formation of $H_2O_2$ by ozonation depends mainly on the direct reactions of ozone with humic acid molecules, while $UV_{254}$ reduction is affected by both the indirect reactions of the radicals and direct reactions of ozone with humic acid.

  • PDF

Characteristic of wastewater treatment using Boron-doped Diamond Electrode (붕소가 도핑된 다이아몬드전극을 이용한 폐수처리특성)

  • Lee, Eun-Ju;Einaga, Y.;Fujishima, A.;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.795-798
    • /
    • 2003
  • Toxic organics are of great environmental concern primarily because they are toxic to mammals and birds, and are relatively soluble in water to contaminate surface water and groundwater. In this study, the decomposition of phenol, a widely used organic, in aqueous solutions by Boron doped diamond(BDD) electrode was examined. Thin, Boron-doped conducting diamond films are expected to be excellent electrodes for industrial electrolysis. Boron-doped diamond (BDD) were used as anode for generating ozone gas by electrolysis of acid solution. In this work. we have studied ozone generating system using BDD electrode. In order to determine the ozone generation properties of diamond electrode, experimental conditions, electrolyte concentration, temperature, flow rate and reaction time were varied diversely. As a result, we could confirm that ozone gas was generated successfully and the performance of diamond electrode was stable for electrolyte while $PbO_2$ electrode was disintegrated. Actually we are found that ozone amount increased by lowering the temperature of electrolyte. Decomposition of phenol concentration in the reaction solution by photolytic ozonation( $UV/O_3$) was analyzed by HPLC epuipped with a UV detector.

  • PDF

3-Dimensional Coating Polymer Microneedles for Economical and Efficient Transdermal Drug Delivery (경제적이고 효과적인 경피 약물전달을 위한 3차원 구조의 코팅 고분자 마이크로니들)

  • Lee, Han-Sol;Park, Jung-Hwan
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.391-396
    • /
    • 2014
  • Polymer microneedles can be fabricated by a micromolding method, an easy and cost-effective method. However, it is not easy to achieve uniform coating with an aqueous coating solution due to hydrophobic surface of polymer microneedles. 3-Dimensional coating polymer microneedles could deliver more than twice as much dose as in-plane metal microneedles by increasing coating area and the number of microneedles per unit area. A uniform coating was not obtained by addition of coating additives in the coating solution. The satisfied coating was achieved by treatment of surface of polymer microneedle with metal deposition and UV/ozone, and UV/ozone treatment was an ultimate surface treatment method based on biological safety. Calcein coating polymer microneedles were prepared by using UV/ozone treatment and followed dip-coating, and they delivered calcein in porcine skin successfully after 15 min of insertion.

The Optimum Cleaning Process of Non-aqueous Alternative Solvents for 1,1,1-TCE (1,1,1-TCE에 대한 비수계성 대체세정제의 최적 세정공정)

  • Jung, Duck-Chae;Lee, Ki-Chang;Kong, Seung-Dae;Mok, Gab-Young;Lee, Seok-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.237-240
    • /
    • 1999
  • This study showed that the optimized cleaning process using non-aqueous cleaning solvents is adaptable in the industrial field for existing 1.1.1-TCE cleaning solvents which is an ozone depleting sustance. Alternative cleaning solvent system substituted for existing cleaning solvent against non-aqueous pollutants(cutting & flux oil), was evaluated for the cleaning efficiency using gravimetric analysis method and surface change of sample by Image analyzer. The results showed that alternative solvents and process had excellent cleaning efficiency.