• Title/Summary/Keyword: applicator

Search Result 161, Processing Time 0.036 seconds

Ground Speed Control of a Direct Injection Sprayer

  • Koo, T.M.;Sumner, H.R.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.500-510
    • /
    • 1996
  • A Direct injection -mixing total -flow -control sprayer was developed and evaluated . The system provided precise application rates and minimized operator exposure to chemicals as well as providing a possibility for recycling container so f unused chemicals that can causes environmental contamination. Chemicals were metered and injected proportionally to the diluent flow rate to provide constant concentrations. The main diluent flow was varied in response to changes in travel speed. Experimental variables of the sprayer were the control interval, the sensitivity of flow regulating valve, the tolerance of control object and the sensitivity of the injection pump system. The optimal performance of the flow control system was with an average response time of 8.5 sec at an absolute steady state of error of 0.067 L/min (0.8% of flow rate). The average response time of the injection rate was -0.53 sec and the coefficient of variation (CV) of concentration was 3.2%.

  • PDF

Applications of a Quadrant plane Amorphous Silicon Photo Position Sensor (4분면 아몰퍼스 실리콘 Photo 위치센서의 응용)

  • 김철한;신영록;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.445-447
    • /
    • 2000
  • The terminal and core(wire conductor) in a Harness processing is connected by putting them in a applicator by virtue of a manual operation. A normal or abnormal condition of crimping connections is nearly determined by a skilled worker. In general, a skilled worker operates a press motor with a foot switch by pressing on foot and puts a wire conductor into a press with one hand. By doing so, sufficient efficiency is not obtained by a worker. In this paper, a basic study has done to make improve an efficiency by finding the normal arrangement out as to whether a terminal and wire conductor in Harness are placed on the right position or not with a quadrant plane photo position sensor.

  • PDF

LOW TEMPERATURE DIAMOND GROWTH USING MICROWAVE PLASMA CVD

  • Sakamoto, Yukihiro;Takaya, Matsufumi;Shinohara, Kibatsu
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.5
    • /
    • pp.487-493
    • /
    • 1996
  • Diamond films were grown at lower temperatures (630-813K) on Si, Al (1100P), and Al-Si(8A, 8B, BC) alloy substrates using improved microwave plasma CVD apparatus in a mixed methane and hydrogen plasma. Improved microwave plasma CVD apparatus equipped water cooled substrate holder and the substrates were set up lower position than bottom line of the applicator waveguide. When the methane concentration was high and growth was conducted at lower pressures the diamond films were synthesized. Moreover the deposits on the scratched substrates formed flat surfaces consisting of fine grains. XRD results, the deposits were identified to cubic diamond. An analysis using Raman spectroscopy, further confirmed that diamond films deposited on the Si substrates were high quality. The deposits on the Al substrates, in contrast, contained amorphous carbon. While the quality of the deposits on the Al-Si substrates were differed with the substrate alloys.

  • PDF

Microwave Sintering of WC-Co Hard Metals (WC-Co 초경합금의 마이크로파 소결)

  • 송강석;김석범
    • Journal of Powder Materials
    • /
    • v.10 no.4
    • /
    • pp.249-254
    • /
    • 2003
  • WC-6wt%Co hard metal powders were sintered by a 2.45 GHz multimode microwave applicator in Ar atmosphere. Microwave sintering of WC-6wt%Co powder lowered the sintering temperature and shortened the processing time in less than two hours than by a conventional method. Microstructures of the sintered specimen were studied with scanning electron microscope (SEM) and no abnormal grain growth was observed. Mechanical properties were similar to the values of the specimens sintered by a conventional method. Specimen sintered at 135$0^{\circ}C$ for 30 minutes ,hewed 99%, 20.5 GPa and 8.1 MPa$\sqrt{m}$ of theoretical density, hardness and fracture strength, respectively.

A Study about the Change of Locations of the Center of Resistance According to the Decrease of Alveolar Bone Heights and Root Lengths during Anterior Teeth Retraction using the Laser Reflection Technique (Laser 반사측정법을 이용한 전치부 후방 견인시 치조골 높이와 치근길이 감소에 따른 저항중심의 위치변화에 관한 연구)

  • Min, Young-Gyu;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.165-181
    • /
    • 1999
  • Treatment mechanics should be individualized to be suitable for each patient's personal teeth and anatomic environment to get a best treatment result with the least harmful effects to teeth and surrounding tissues. Especially, the change of biomechanical reaction associated with that of the centers of resistance of teeth should be considered when crown-to-root ratio changed due to problematic root resorption and/or periodontal disease during adult orthodontic treatment. At the present study, in order to investigate patterns of initial displacements of anterior teeth under certain orthodontic force when crown-to-root ratio changed in not only normal periodontal condition but also abnormal periodontal and/or teeth condition, the changes of the centers of resistance for maxillary and mandibular 6 anterior teeth as a segment were studied using the laser reflection technique, the lever & pulley force applicator and the photodetector with these quantified variables reducing alveolar bone 2mm by 2mm for each of maxillary 6 anterior teeth until the total amount of 8mm and root 2mm by 2mm for each of mandibular 6 anterior ones until the total amount of 6mm. The results were as follows: 1. Under unreduced condition, the center of resistance during initial displacement of maxillary 6 anterior teeth was located at the point of about $42.4\%$ apically from cemento-enamel junction(CEJ) of the averaged tooth of them and kept shifting to about $76.7\%$ with alveolar bone reduction. 2. The distance from the averaged alveolar crest level of maxillary 6 anterior teeth to the center of resistance for the averaged tooth of them kept decreasing with alveolar bone reduction, but the ratio to length of the averaged root embedded in the alveolar bone was stable at around $33\%$ regardless of that. 3. Under unreduced condition, the center of resistance during initial displacement of mandibular 6 anterior teeth was located at the Point of about $43\%$ apically from CEJ of the averaged tooth of them and this ratio kept increasing to about $54\%$ with root reduction. But the distance from CEJ to the center of resistance decreased from around 5.3mm to around 3.3mm, that is to say, the center of resistance kept shifting toward CEJ with the shortening of root length. 4. A unit reduction of alveolar bone had greater effects on the change of the centers of resistance than that of root did during initial Phase of each reduction. But both of them had similar effects at the middle region of whole length of the averaged root.

  • PDF

Exposure Assessment of Apple Orchard Workers to the Insecticide Imidacloprid Using Whole Body Dosimetry During Mixing/Loading and Application (전신복장법을 이용한 농약 조제 및 살포 과정 중 살충제 Imidacloprid에 대한 사과 과수원 농작업자의 노출 평가)

  • Lee, Jae Yun;Noh, Hyun Ho;Park, Hyo Kyoung;Jeong, Hye Rim;Jin, Me Jee;Park, Kyung-Hun;Kim, Jeong-Han;Kyung, Kee Sung
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.3
    • /
    • pp.271-279
    • /
    • 2016
  • To evaluate exposure characteristics of the insecticide imidacloprid to apple orchard workers during treatment on orchard fields and evaluate its potential risk using a whole body dosimetry (WBD) method, 1,000-time diluted acephate+imidacloprid 25(20+5)% solutions were sprayed on 10 apple orchard fields in Cheongju with a speed sprayer at a rate of 3,000 L/ha/person, after put on clothes such as inner/outer clothes, personal air pump with a IOM sampler, nitrile glove and mask. Exposure test included mixing, loading and application steps. The test pesticide imidacloprid residues in the collected samples were analyzed with a HPLC-DAD. Recoveries ranged from 81.5 to 108.6% for analytical method validation and from 73.8 to 86.7% for field recovery. Total exposed amounts to mixer/loader and applicator were found to be 0.0014-0.0279% of total applied active ingredient of imidacloprid. Glove exposure of both mixer/loader and applicator was higher than the other parts. Margins of safety of mixer/loader and applicator were calculated to be 97-355 and 46-196, respectively, indicating that exposure risk of imidacloprid to apple orchard workers by spraying with a speed sprayer was very low.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Study on Refining Technique of Raw Lacquer (I) - Properties of Raw Lacquer, Refined Lacquer and Film according as Their Collecting Places and Seasons - (옻칠의 정제기술에 관한 연구(I) - 생산지·생산시기에 따른 생칠과 옻칠의 특성 및 도막 특성 -)

  • Song, Hong-Keun;Han, Chang-Hoon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • In this study, we obtained fundamental data about Korean raw lacquer's physical and chemical properties to produce high quality lacquer. The tested raw lacquers were obtained from Won-ju in Korea, Shanxishang, Guizhoushang, Anhuishang in China. The drying time of refining lacquers, tensile strengths of dried films and uniformity of films are measured. The refined lacquers were prepared by experimentally scaled refining equipment. Films of lacquer were applied on glasses by film applicator. This films were tested by universal strength test machine. The films were pictured by scanning electron microscopy and confocal microscopy to define the uniformity of them. The refining method were not different among three different kind of raw lacquers which were different their collecting time and places. But the viscosity of them were quite different. When black refined lacquer is made with iron powder, the adding time of iron powder is critical to control the viscosity of it. The refining times, viscosity and tensile strength of refined lacquers were not depended the method of refining condition but the place of collecting of raw lacquer.

  • PDF

Quality Assurance of Air Kerma Strength for Ir-192 High Dose Rate Source (Ir-192 고선량률 선원에 대한 공기커마강도의 품질보증)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.147-151
    • /
    • 2007
  • AAPM TG43 report has recommended to measure air kerma strength with the strength of source. Main purpose of this study is to verify the accuracy of air kerma strength provided by manufacturer. Materials for this study were MAX-4001 Electrometer, HDR 1000 Plus of the corporation of standard imaging, and 6 french bronchial Applicator with 1000 mm. we measured ionization current in 10-90 mm range from the bottom of the central axis of chamber. The reference point of calibration displayed by the maximum ionization current in the ionization current curve was measured, and air kerma strength was computed from the maximum ionization current. we acquired 50 mm distance to correspond with the maximum ionization current in the ionization current curve. Its distance has perfectly fitted to the source reference point of calibration certificate of UW-ADCL. Air kerma strength computed value has measured about 0.5% more than calibration value provided by manufacturer. Air kerma strength of calibration certificate provided by manufacturer has acquired reliable results. This study shows that considering the move error of dwell position of source and the dead space length in well-type chamber is a good way to get an accurate result.

  • PDF

Dose Distribution of Rectum and Bladder in Intracavitary Irradiation (자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가)

  • Chu S. S.;Oh W. Y.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF