• Title/Summary/Keyword: application method

Search Result 22,746, Processing Time 0.056 seconds

Removal of water pollutants and its application to swine wastewater treatment through the establishment of best optimal growth conditions of Ankistrodesmus bibraianus (Ankistrodesmus bibraianus의 최적 배양조건 설정을 통한 수질오염물질 제거 및 축산 폐수 처리 적용)

  • Hwang, In-Seong;Park, Young-Min;Lee, Ye-Eun;Kim, Deok-Won;Park, Ji-Su;Oh, Eun-Ji;Yoo, Jin;Chung, Keun-Yook
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.82-92
    • /
    • 2020
  • Since swine wastewater contains high concentrations of nutrients and heavy metals, it deteriorates water quality when discharged. Compared to conventional methods, bioremediation can be a promising method for its treatment. Specifically, microalgae have the potential to remove these pollutants. In this study, the removal of nutrients (nitrogen (N) and phosphorus (P)) and heavy metals (copper (Cu) and zinc (Zn)) from swine wastewater by Ankistrodesmus bibraianus was evaluated and the organism's optimal growth conditions were investigated. The optimal growth conditions were established at 28℃, pH 7, and light and dark cycles of 14:10 h. The removal efficiencies of N and P by a single treatment (500, 1,000, 5,000, and 10,000 mg L-1) ranged from 22.9 to 80.6% and from 11.9 to 50.0%, respectively. The removal efficiencies of N and P in the binary treatments ranged from 16.4 to 58.3% and from 7.80 to 49.8%, respectively. The removal efficiencies of Cu and Zn by a single treatment(10, 30, and 50 mg L-1) ranged from 15.5 to 81.5% and from 6.28 to 34.3%, respectively. Similarly, the removal efficiencies of Cu and Zn in the binary treatments ranged from 16.7 to 74.5% and from 5.58 to 27.5%, respectively. In addition, the study showed the optimal growth conditions for microalgae and the removal efficiency of nutrients (N and P) and heavy metals (Cu and Zn), which could be applied to swine wastewater. Based on the results in this study, it appears that Ankistrodesmus bibraianus could be used for the removal of nutrients and heavy metals present in swine wastewater.

Effects of green manures in organic vegetable production (유기농 채소생산을 위한 녹비작물 도입효과)

  • Lee, Sang-Min;Lee, Y.;Yun, H.B.;Sung, J.K.;Lee, Y.H.;Lee, S.B.;Choi, K.J.;Kim, K.H.
    • Proceedings of the Korean Society of Organic Agriculture Conference
    • /
    • 2009.12a
    • /
    • pp.77-101
    • /
    • 2009
  • Organic farming in Korea has mainly focused on producing vegetables in plastic film house and cereals in paddy field. For high productivity of vegetables and cereals, most Korean farmers have not applied crop rotation in the cropping system. Thus, this study was carried out to evaluate the effects of crop rotation on the yield of red pepper and green onion, the changes in soil fertility and the potential as green manure of rye and hairy vetch. Rye and hairy vetch were cultivated for winter season every year, and directly incorporated into the soil. The yield of red pepper fruits in organic farming using crop rotation (OFCR) decreased 23 to 36% compared with conventional farming system (CFS). Whereas, green onion showed the increased yield of about 13%. In OFCR, total carbon content of soil was higher, however available phosphate content lower than conventional farming. As a result of measuring the bulk density of soil, OFCR and CFS were 1.26 to $1.35Mg/m^3$ and 1.37 to $1.42Mg/m^3$, respectively. Carbon and nitrogen contents of microbial biomass in OFCR were obviously higher compared with the CFS. In the plot cultivated rye for winter season, the weed germination was strongly reduced (about 52 %). Balance of macro nutrient elements, nitrogen and phosphate, in the application of rye and hairy vetch had a minus value. For potassium, the output value was higher than the input one, therefore organic farming under red pepper-rye or hairy vetch systems requires applying additional potassium input. Also, we selected two hairy vetch varieties of cv. Hungvillosa and Ostsaat which can be adapt at Korea climate. In order to estimate a yield of green manures, the weight of shoot and root was measured. The ratio of shoot and root between rye and hairy vetch showed 0.88 and 1.91, respectively. The potential levels of nitrogen, phosphate and potassium which could be supplied from rye were 7.7, 7.8 and 21.9 kg/10a and from hairy vetch were 17.0, 8.6 and 22.9 kg/10a, respectively. So we recommend that cultivating hairy vetch, as a nutrient supplier, and rye, as an amendment to enhance the soil physical property, for winter season be practical method in Korea organic farming system.

  • PDF

Comparisons between the Two Dose Profiles Extracted from Leksell GammaPlan and Calculated by Variable Ellipsoid Modeling Technique (렉셀 감마플랜(LGP)에서 추출된 선량 분포와 가변 타원체 모형화기술(VEMT)에 의해 계산된 선량 분포 사이의 비교)

  • Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 2017
  • A high degree of precision and accuracy in Gamma Knife Radiosurgery(GKRS) is a fundamental requirement for therapeutical success. Elaborate radiation delivery and dose gradients with the steep fall-off of radiation are clinically applied thus necessitating a dedicated Quality Assurance(QA) program in order to guarantee dosimetric and geometric accuracy and reduce all the risk factors that can occur in GKRS. In this study, as a part of QA we verified the accuracy of single-shot dose profiles used in the algorithm of Gamma Knife Perfexion(PFX) treatment planning system employing Variable Ellipsoid Modeling Technique(VEMT). We evaluated the dose distributions of single-shots in a spherical ABC phantom with diameter 160 mm on Gamma Knife PFX. The single-shots were directed to the center of ABC phantom. Collimating configurations of 4, 8, and 16 mm sizes along x, y, and z axes were studied. Gamma Knife PFX treatment planning system being used in GKRS is called Leksell GammaPlan(LGP) ver 10.1.1. From the verification like this, the accuracy of GKRS will be doubled. Then the clinical application must be finally performed based on precision and accuracy of GKRS. Specifically the width at the 50% isodose level, that is, Full-Width-of-Half-Maximum(FWHM) was verified under such conditions that a patient's head is simulated as a sphere with diameter 160mm. All the data about dose profiles along x, y, and z axes predicted through VEMT were excellently consistent with dose profiles from LGP within specifications(${\leq}1mm$ at 50% isodose level) except for a little difference of FWHM and PENUMBRA(isodose level: 20%~80%) along z axis for 4 mm and 8mm collimating configurations. The maximum discrepancy of FWHM was less than 2.3% at all collimating configurations. The maximum discrepancy of PENUMBRA was given for the 8 mm collimator along z axis. The difference of FWHM and PENUMBRA in the dose distributions obtained with VEMT and LGP is too small to give the clinical significance in GKRS. The results of this study are considered as a reference for medical physicists involved in GKRS in the whole world. Therefore we can work to confirm the validity of dose distributions for all collimating configurations determined through the regular preventative maintenance program using the independent verification method VEMT for the results of LGP and clinically assure the perfect treatment for patients of GKRS. Thus the use of VEMT is expected that it will be a part of QA that can verify and operate the system safely.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Establishment of Featal Heart Surgery with an Improvement of the Placental Blood Flow in Cardiopulmonary Bypass Using Fetal Lamb Model (양태아를 이용한 심폐우회술에서의 태반혈류개선을 통한 태아심장수술의 기반기술 확립)

  • 이정렬;박천수;임홍국;배은정;안규리
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • Background: We tested the effect of indomethacine and total spinal anesthesia on the improvement of placental flow during cardiopulmonary bypass on fetal lamb. Material and Method: Twenty fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Ten served as a control group in which placenta was worked as an oxygenator during bypass (Control group). The remainder worked as an experimental group in which pretreatment with indomethacine and total spinal anesthesia was performed before bypass with the same extracorporeal circulation technique as control group (Experimental group). Observations were made every 10 minutes during a 30-minute bypass and 30-minute post bypass period. Result: Weights of the fetuses ranged from 2.2 to 5.2 kg. In Control group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of Pa$CO_2$ increased from 61.9 to 129.6 mmHg at each time points during bypass. Flow rate was suboptimal (74.3 to 97.0 $m\ell$/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. On the contrary, in Experimental group, means of arterial pressure reamined higher (45.8 to 30 mmHg) during bypass (p<0.05). Means of Pa$CO_2$ were less ranging from 59.8 to 79.4 mmHg during bypass (P<0.05). Flow rates were higher (78.8 to 120.2 $m\ell$/kg/min) during bypass (p<0.05). There were slower deterioration of cardiac function after cessation of bypass. Conclusion: In this study, we demonstrated that the placental flow was increased during fetal cardiopulmonary bypass in the group pretreated with indomethacine and total spinal anesthesia. However, further studies with modifications of the bypass including a creation of more concise bypass circuit, and a use of axial pump are mandatory for the clinical application.

Relationship of Hemodynamic Changes during Off-Pump Coronary Bypass Grafting and Their Effects on Postoperative Outcome (심폐바이패스 없이 시행하는 관상동맥 우회수술 중의 혈역학적 변수들의 변화양상 및 수술 후 결과에 미치는 영향)

  • 허재학;장지민;김욱성;장우익;이윤석;정철현
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.576-582
    • /
    • 2003
  • During the Off-Pump Coronary Arterial Bypass surgery (OPCAB), the manipulation of the heart can depress cardiac contractility and cause hemodynamic instability. In this study, hemodynamic parameters were measured during operation and the laboratory and clinical data were investigated to evaluate their effects on postoperative outcome. Material and Method: From March 2001 to August 2002, 50 consecutive patients who underwent OPCAB were included in this study. During the same period, total number of CABG was 71 The blood pressure, pulmonary artery pressure, mixed venous oxygen saturation, and cardiac index were measured before manipulation, after application of stabilizer, and at the end of anastomosis. Postoperatively, we measured the cardiac enzymes such as CK-MB, troponin 1 and checked the amount of inotropes required, chest tube drainage, the amount of transfusion, duration of ventilator support, and duration of ICU stay. Result: The number of mean distal anastomoses was 2.8$\pm$0.9 per patient. On elevation and stabilization of the heart, systolic blood pressure was depressed and pulmonary artery pressure was elevated significantly, but during each anastomosis no significant changes were detected. The peak level of cardiac markers was 29.2$\pm$46.7 for CK-MB, 0.69$\pm$0.86 for troponin 1 on postoperative day f. Among the intraoperative hemodynamic parameters, the ischemic change of EKG and bolus injection of inotropes significantly affected the posteroperative cardiac enzymes. But, no difference other than the level of cardiac enzymes between the two groups with or without the ischemic change of EKG and bolus injection of inotropes was noticed. Conclusion: The significant hemodynamic changes occurred when the heart was elevated and stabilized, however during anastomoses there were no significant changes. Serum cardiac enzymes rose significantly in the group that showed the ischemic charge of EKG or needed the bolus injection of inotropes for maintaining hemodynamic stability intraoperatively, but it did not affect the postoperative outcome. In conclusion, the ischemic change of EKG and the need for bolus injection of intropes during operation may be very indicative for probable ischemia.

Development for Fishing Gear and Method of the Non-Float Midwater Pair Trawl Net(I) - Opening Efficiency of Model Net according to the Length of Lower Warp - (무부자 쌍끌이 중층망 어구어법의 개발(I) - 아래끌줄의 길이에 따른 모형어구의 전개성능 -)

  • 이주희;유제범;이춘우;권병국;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.1
    • /
    • pp.33-43
    • /
    • 2003
  • The midwater pair trawl which is being used at present in Korea have several problems. Firstly, it is difficult to control the net height on high towing speed. Secondly, net breaking often occurs owing to floats and thirdly, the volume of net on the net drum is so large. This study is aiming for examining the possibility of application for the Korean midwater pair trawl through the model experiment of non-float midwater pair trawl. The model of non-float midwater pair trawl was manufactured as 1/100 of the full scale net which is being used in bottom pair trawl for 850ps class considering the Tauti's Similarity law. The model experiment was carried out to analyze the opening efficiency according to the variation of lower warp length and the opening efficiency was investigated between th proto type and non-float type. The results obtained can be summarized as follows ; 1. The hydrodynamic resistance of non-float type was about 10~20% smaller than that of the proto type and it increased about 1ton according to the increase of dL at the condition of the same flow speed. The resistance acting on the lower warp decreased about 5% but that of the upper warp increased according to the increase of lower warp length (dL) at the condition of the same flow speed. 2. The net height of the non-float type decreased almost linearly according as the increased of flow speed and it increased in a logarithmic functional form with the increase of the lower warp length at the condition of the same flow speed. On the decreasing rate of the net height, the non-float type was lower than the proto type and the difference of the decreasing rate was about 12% at 3.0 knot, 25% at 4.0 knot, 25% at 4.0 knot respectively when dL was 30m. 3. The net width of non-float type was not varied so much as only 2m range and was larger than that of proto type. 4. The mouth area of non-float type decreased in a exponential functional form. On the decreasing rate of the mouth area, the non-float type was lower than the proto type. The filtering volume increased in a logarithmic functional form with increasing flow speed and the filtering volume of proto type decreased steeply over 3.0knot, but that of non-float type increased until 4.0knot. 5. The optimal length of lower warp was when the value of dL was about 30m and the optimal position of front weight was at the connection point of four net pendants.

Studies on the Effect of the Thickness of Lining on Water Holding Capacity and Lield in Rice Patty with High Permeability (누수유에 있어서 밑다짐 두께의 차이가 보수력 및 수호량에 미치는 영향)

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1598-1603
    • /
    • 1969
  • A field expeperiment has been conducted in order to explore possibilities of efficient and economical irrigation methods for the rice cultivation through which irrigation water may be saved and rice paddies may keep water for longer period of time, resulting in an increased yield of rice. Some of the major findings from the experimentation are summarized in the following. 1. There is slightly significant difference among experimental plots in the weight of rice straw. 2. The 9cm-lined plot proves to be the best in terms of the thickness. In this connection, however, it seems to by 3cm. 3. The wheat straw-lined plot is found superior in yield. However, this may be resulted in by the application of more fertilizer, and how long the plot could be durable may be problematic. Since every two or three years the straw-lining work has to be done, more labour may be required of the plot. 4. It would be inappropriate to expect any meaningful experimental results for the first year, since surface soil and deep soil are mixed up in the course of work. There is not observed any meaningful difference in the number of ears per stalk and in the number of grains per ear. However, in the lined plots, the number of tillers is slightly increased. 5. Irrigation has been applied by means of ordinary method after lining. When irrigation is applied at the interval of five to six days, irrigation water is saved by 44.9 per cent in the case of 9cm-lined plot, 39.7 per cent in the case of 6 cm-lined plot, and 36.3 percent in the case of 3 cm-lined plot. 6. An increased yields arenoted in the wheat straw-lined plot by 23.8 per cent, in the 9 cm-lined plot by 20.1 per cent, in the 3 cm-lined plot by 12 per cent. and in the case of vinyl-lined plot by 12.5 per cent. 7. The rate of maturity of grains is proved better, and the husking rate also found better(75%), that is, the quality of rice grains is improved.

  • PDF

Survival Ability of Porcine Oocytes Frozen-Thawed by Open Pulled Straw Method (Open Pulled Straw 방법에 의해 동결-융해된 돼지난자의 생존능력)

  • 김세웅;박춘근;정희태;양부근;김정익
    • Journal of Embryo Transfer
    • /
    • v.16 no.2
    • /
    • pp.117-125
    • /
    • 2001
  • Vitrification of oocytes has been applied recently fur pigs, but remains elusive. The purpose of this study is to investigate the effects of vitrification in open pulled straws (OPS) on in vitro survival of porcine oocytes. When immature follicular oocytes frozen-thawed were cultured for in vitro maturation, maturation rates to metaphase-II stage were higher in oocytes with (25%) than without (15%) cumulus cells. After In vitro fertilization of oocytes frozen-thawed, the maturation rates were also significantly (P<0.05) higher in oocytes with (41%) that than without (17%) cumulus cells. However, the penetration rates were higher in oocytes without (19%) that than with (9%) cumulus. In another experiment, porcine oocytes matured in vitro were frozen and thawed for in vitro fertilization. The penetration rates were higher than in oocytes without (35%) that than with (26%) cumulus cells. However, the proportions of oocytes dead after in vitro fertilization were significantly (P<0.05) higher in oocytes with that than without cumulus cells. On the other hand, the rates of penetration and dead oocytes at 6 h after in vitro fertilization were not significant differences between oocytes with and without cumulus cells. However, the proportions of dead oocytes with (18%) and without (16%) cumulus cells were higher than in oocytes of control group (0%). These finding indicated the possible broader application for OPS, as they demonstrated that the maturation and fertilization in vitro by frozen-thawed oocytes may be accompained by cumulus cells and culture periods according to the requirements of the survival ability after freezing of mature and immature oocytes in pigs.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF