• 제목/요약/키워드: appliance

Search Result 1,567, Processing Time 0.028 seconds

A STUDY ON THE EFFECT OF THE CHINCAP BY FINITE ELEMENT ANALYSIS IN JUVENILE SKELETAL CLASS III PATIENTS (유년기 골격성 III급 부정교합자에서 이모장치의 효과에 관한 유한요소분석법적 연구)

  • Choi, Jeong-Ho;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.28 no.3 s.68
    • /
    • pp.353-370
    • /
    • 1998
  • This study was conducted to investigate the changes in the structural parts of the craniofacial skeleton subsequent to chincap therapy in the juvenile skeletal Class III patients. The subject consisted of 29 Korean children(14 males, 15 females) who had skeletal Class III malocclusion and were undergone chincap therapy from the beginning of the treatment (and an auxilliary upper removable appliance, if necessary). The control group was composed of 21 children(10 males, 11 females) with skeletal Class III malocclusion who had no orthodontic treatment. Cephalometric data at the mean age of 7 and 2 years later were analyized by finite element method, and compared between groups by independent group t-test(p<0.05). The results of the present study were as follows; 1. There were no significant changes in the cranial base, posterior face, upper anterior face, ramus, chin and soft tissues by the chincap therapy. 2. The mandibular body showed significant differences in the minimum extention ratio and the overall shape ratio. This means that the vertical direction of growth was retarded by the chincap therapy. 3. The major direction of the growth in the maxillary basal bone was significantly more horizontal in the experimental group, which suggests that the vertical growth of maxilla was inhibited. 4. There was statistical difference in the major direction of the growth of the anterior face between groups. This may be due to the significant difference in the major direction of growth of the lower anterior face, supposed to be resulted from the mandibular rotation and/or displacement by the chincap therapy. The change in the oral functional space seemed to be caused by the same reason. 5. From the standpoint of these results, the retardation of growth, the changes of the growth direction and the morphological changes could be accepted partly, but the major effect of the chincap seems to be the rotation and the displacement of the mandible.

  • PDF

A Research on the Basis of Questionnaires about the Dental Patients' Awareness and Understanding of TMDs (측두하악장애에 대한 치과 내원환자의 인지도와 이해도에 관한 설문조사 연구)

  • Kim, Kyung Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.3
    • /
    • pp.275-289
    • /
    • 2013
  • This study was conducted to investigate and analyze the dental patients' awareness and understanding about TMDs. Among the total number of 243 patients who had visited the department of dentistry of Busan Paik Hospital, Inje University or Hanvit dental hospital in Ulsan metropolitan city and participated in the survey, 195 patients who filled in all parts of the questionnaire were selected as the subjects. The results were as follows. 1. The subjects who were aware of the term, "TMDs" were 17.4%. The group with total education period of 12 years and over was significantly more aware of "TMD"(82.4%, p<0.01) than the other group. The subjects who were aware of the term, "jaw joint disease" were 81.0%. 30 to 49 age group(45.6%, p<0.05) and the group with total education period of 12 years and over(60.1%, p<0.01) were significantly more aware of "jaw joint disease" than other groups. 2. More than half of the subjects chose "overuse of the jaws" as the concept of jaw joint disease(50.6%). 3. TV, radio(41.4%) was the most frequent source of awareness about jaw joint disease followed by family and friends(20.2%), hospitals and health professionals(18.2%), internet(15.7%) and newspapers, magazines(4.5%). Among the respondents who were aware of jaw joint disease through TV, radio, 30 to 49 age group showed significantly higher percentage(52.4%, p<0.05) than other age groups. Among the respondents who were aware of jaw joint disease through internet, 18 to 29 age group showed significantly higher percentage(61.3%, p<0.01) than other age groups. Among the respondents who were aware of jaw joint disease from hospitals and health professionals, the group with total education period of 12 years and over showed significantly higher percentage(75.0%, p<0.05) than the other group. 4. Noise during mouth opening and closing(26.9%), mouth opening difficulty(25.1%) and jaw pain(13.7%) were the most frequently responded sign and symptoms of jaw joint disease. For the causes of jaw joint disease, enjoying hard food chewing(19.5%), occlusal discrepancy(19.0%) and chewing with one side only(18.5%) were responded in sequence. TMJ surgery(28%) was the most frequently responded treatment method for jaw joint disease, followed by occlusal appliance therapy(23.9%) and physical therapy(14.6%). For preventive method of jaw joint disease, avoid eating hard food(21.1%), avoid opening mouth wide(17.0%) and simultaneous using of molar of both side when chewing food(15.4%) were chosen frequently.

The effect of copper alloy scaler tip on the surface roughness of dental implant and restorative materials (구리 합금 초음파 스케일러 팁이 치과 임플란트 및 수복 재료 표면에 미치는 영향)

  • Lee, Ah-Reum;Chung, Chung-Hoon;Jung, Gyu-Un;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • Purpose: This study is designed to investigate the various impacts of different types of scaler tips such as cooper alloy base tip and the others on the surface roughness of teeth and implant by the method which is currently in clinical use. Materials and methods: Four different types of disc shaped porcelain, titanium, zirconia, and Type III gold alloy dental materials sized 15 mm diameter, 1.5 mm thickness were used for the experiment. Plastic hand curette (Group PS), cooper alloy new tip (Group IS), and stainless steel tip (Group SS) were used as testing appliances. A total of 64 specimens were used for this study; Four specimens for each material and appliance group. Surface roughness was formed with 15 degree angle in ultrasonic scaler tip and with 45 degree angle in hand curette of instrument tip and the specimen surface with 5 mm long, one horizontal-reciprocating motion per second for 30 seconds by 40 g force. To survey the surface roughness of each specimen, a field emission scanning electron microscope, an atomic force microscope, and a surface profiler were used. (Ra, ${\mu}m$). Results: According to SEM, most increased surface roughness was observed in SS group while IS groups had minimal roughness change. Measurement by atomic force microscope presented that the surface roughness of SS group was significantly greater than those of PS, IS and control groups in the type III gold alloy group (P<.05). IS group showed lesser surface roughness changes compared to SS group in porcelain and gold alloy group (P<.05). According to surface profiler, surface roughness of SS group showed greater than those of PS, IS and control groups and IS group showed lesser than those of SS group in all specimen groups. Type III gold alloy group had large changes on surface roughness than those of porcelain, titanium, zirconia (P<.05). Conclusion: The result of this study showed that newly developed copper alloy scaler tip can cause minimal roughness impacts on the surface of implant and dental materials; therefore this may be a useful alternative for prophylaxis of implant and restored teeth.

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

The effect of labial inclination on intrusion of the upper and lower incisors by three-dimensional finite element analysis (분절호선법으로 상하악 절치부 압하 시 순측경사도가 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Kim, Dong Woo;Yang, Hoon Chul;Kim, Gi Tae;Kim, Sung Sik;Son, Woo Sung
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.259-277
    • /
    • 2003
  • This study was designed to investigate the position of anteroposterior center of resistance for genuine intrusion and the mode of change of the minimum distal force for simultanous intrusion and retraction of the upper and lower incisors according to the increase of labial inclination. For this purpose, we used the three-piece intrusion arch appliance and three-dimensional finite element models of upper and lower incisors. 1. Positions of the center of resistance in upper incisors according to the increase of the labial inclination were as follows; 1) In normal inclination situation, the center of resistance was located in 6m behind the distal surface of the lateral incisor bracket. 2) In $10^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 9mm behind the distal surface of the lateral incisor bracket. 3) In $20^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 12m behind the distal surface of the lateral incisor bracket. 4) In $30^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 16m behind the distal surface of the lateral incisor bracket. 2. Positions of the center of resistance in lower incisors according to the increase of the labial inclination were as follows; 1) In normal inclination situation, the center of resistance was located in 10mm behind the distal surface of the lateral incisor bracket. 2) In $10^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 13m behind the distal surface of the lateral incisor bracket. 3) In $20^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 15m behind the distal surface of the lateral incisor bracket. 4) In $30^{\circ}$ increase of the labial inclination situation, the center of resistance was located in 18m behind the distal surface of the lateral incisor bracket. 3. The patterns of stress distribution were as follows; 1) There were even compressive stresses In and periodontal ligament when intrusion force was applied through determined center of resistance. 2) There were gradual increase of complexity in compressive stress distribution pattern with Increase of the labial inclination when intrusion and retraction force were applied simultaneously. 4. With increase of the labial inclination of the upper and lower incisors, the position of the center of resistance moved posteriorly. And the distal force for pure intrusion was increased until $20^{\circ}$increase of the labial inclination.

A study on the effects of Electrical stimulation by the miniature Electric device on the tooth movement and tissue remodeling (초소형 전기 장치에 의한 전기 자극이 치아 이동과 주위 조직 개조에 미치는 효과에 관한 연구)

  • Park, Soon-Jung;Lee, Young-Jun;Park, Young-Guk;Davidovitch, Zeev
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.279-291
    • /
    • 2003
  • Electric current is a highly probable way as a clinical tool for tooth movement. The purposes of this study were to determine the usefulness of exogenous electric currents in accelerating orthodontic tooth movement and to investigate the effects of electric-orthodontic treatment on the remodeling of the periodontal tissue histologically The study was performed with six male cats weighing around 3kg. The electric device wich is providing the direct electric current of $20{\mu}A$ was inserted to the removable appliance. The right and left maxillary canines were assigned as control and experimental sides respectively. The control canine was Provided with orthodontic force (75gm) oかy and the experimental side was given the same amount of force and electricity. The lingual buttons were bonded to the maxillary canines and both sides of canines were retracted with NiTi coil spring. The electric device was adjusted to provide 20uh direct current to the experimental canines S hours a day The amount of the canine movement was measured with electronic caliper every week. After 4 weeks of tooth movement, the animals were sacrificed and the histologic study was performed. The results of this study were as follows. 1. The application of a direct current to the experimental tooth significantly increased the final amount of orthodontic tooth movement. The amount of tooth movement after 28-day was 37% more in the experimental side. 2. The electrically stimulated tooth showed histologic evidence of significant increases in the amount of bones and matrix deposition in the area of tension. 3. In the compression side, the electric-orthodontic treatment stimulated bone resorption more extensively in the experimental canines. 4. After 28 days of electricity exposure and orthodontic force, the experimental side demonstrated significantly more osteoblasts, osteoclasts, capillaries and osteoid tissues, reflectinr an increase in the local tissue's cellular activity. 5. Intermittent electrical stimulation (five hours a day) had effects to enhance orthodontic tooth movement and tissue remodeling. These results suggested that the low-intensity exogenous electric current by the miniature electric device might accelerate orthodontic tooth movement and bone remodeling in vivo and have the possibility to reduce the orthodontic treatment duration.

Nocturnal Bruxism and Botulinum Toxin Effect on the Subjects with Masseteric Hypertrophy (야간 이갈이와 교근비대 환자의 보툴리눔 독소 주사 효과)

  • Sohn, Seung-Mahn;Chung, Gi-Chung;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.3
    • /
    • pp.337-346
    • /
    • 2007
  • This study aimed to evaluate a relation of bruxism with clinical effects of botulinum toxin type A(BTX-A) injection. 5 bruxers and 5 nonbruxers with bilateral masseter hypertrophy were participated in this study. After injecting 25 unit of BTX-A(Allergen Inc, $Botox^{(R)}$) into each masseter muscle, the thickness of masseter(Mm) and anterior temporalis(Ta) muscles was measured by ultrasonography and the maximum bite force was evaluated during a 9-month period. Self-estimation on the recovery of occlusal force during mastication was done as well. Regardless of presence of bruxsim, all subjects showed significantly reduced Ms thickness(p<0.001) and maximum bite force at $1^{st}$ molars(p=0.027) with their peak at 3 months after injection, which then started to return. No significant difference was observed in Ta thickness and the bite force at the central incisors. While self-estimated occlusal force was the least at 2 weeks after injection and then rapidly returned to the baseline level with full recovery at the time of 6 to 9 months after injection, the maximum bite force measured by bite force recorder did not recover the original value, particularly in the nonbruxer group. It is assumed that nocturnal bruxism can influence recovery of atrophic masseter and decreased occlusal force due to BTX-A injection. These findings suggest a need of occlusal appliance to control bruxism or clenching habit for longer clinical effect of BTX-A injection.

Supplemental Value of the Wrist-Worn Actigraphy in Diagnosing the Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 진단에서 손목부착형 활동기록기의 보조적 진단가치)

  • Im, Mee-Hyang;Shin, Hong-Beom;Lee, Yu-Jin;Lee, Seung-Hi;Won, Chang-Yeon;Lee, Myung-Hee;Lee, Soo-Young;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.1
    • /
    • pp.32-38
    • /
    • 2005
  • Objectives: Obstructive sleep apnea syndrome (OSAS) has drawn increasing attention as medical community has become to be aware of its co-morbidities and complications, especially cardiovascular complications and excessive daytime sleepiness with accident proneness. As of now, polysomnography is the standard tool to diagnose sleep apnea and estimate the treatment validity. However, its being rather expensive and inconvenient, alternate diagnostic tools have been proposed including wrist actigraphy. So far, actigraphies have been adopted usefully to field-survey sleep apnea prevalence. In this study, we attempted in a sleep laboratory setting to assess the supplemental value of actigraphy in diagnosing OSAS. Methods: This study was done at the Division of Sleep Studies, the Seoul National University Hospital. Thirty-seven clinically suspected cases of OSAS underwent the one-night polysomnography, simultaneously wearing an actigraphy on non-dominant wrist. We analyzed the data of 27 polysomnographically-proven OSAS patients (male:female 20: 7;age $47.6{\pm}12.9$ years old;age range 23 to 72 years) with no other sleep disorders. We calculated RDI (respiratory disturbance index) from the polysomnography data and FI (fragmentation index) from the actigraphy data. Pearson correlation was calculated in order to compare FI with RDI and to evaluate the supplemental diagnostic value of the actigraphy. Results: Mean total sleep time on polysomnography was $401.4{\pm}57.8\;min$ (range of 274.0 to 514.1 min). Mean RDI was $21.7{\pm}20.4/hour$. Mean FI was $21.9{\pm}13.0/hour$. RDI and FI showed significant correlation (r=0.55, p<0.01). Conclusions: Wrist actigraphy in OSAS patients generates a comparable outcome to polysomnography, in measuring the nocturnal sleep fragmentation. The actigraphy could be used supplementally in inpatients, outpatients, and field survey subjects, if polysomnography is unavailable or impossible. In follow-ups related with nasal CPAP (continuous positive airway pressure), upper airway surgery, and oral appliance in OSAS patients, the actigraphy might play a more dominant role in the future.

  • PDF

Comparison of Awareness of Symptoms and Illness Between Patients with Obstructive Sleep Apnea and Simple Snoring (수면무호흡증과 단순 코골이 환자의 증상과 질환 인식도 비교)

  • Lee, Seyoung;Kang, Jae Myeong;Cho, Yoon-Soo;Yoon, Hyun Jin;Kim, Ji-Eun;Shin, Seung-Heon;Park, Kee Hyung;Kim, Seon Tae;Kang, Seung-Gul
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.1
    • /
    • pp.16-24
    • /
    • 2016
  • Background and Objectives: Obstructive sleep apnea (OSA) is often undiagnosed but is an important risk factor affecting the health of an individual. The level of awareness of the illness among patients with OSA is low and is not correlated with severity of the illness. This study was conducted to compare awareness of OSA symptoms and illness between patients with OSA and simple snorers. Materials and Methods: Two hundred eighty-two patients who were suspected of having OSA participated in this study. All subjects underwent overnight polysomnography. Those with an apnea-hypopnea index (AHI) ${\geq}5$ were classified as the OSA group, while those with an AHI < 5 were classified as the simple snoring group. A sleep questionnaire, which included items on awareness of the illness, OSA, and sleep symptoms, was administered to all subjects and their bed-partners. Results: Simple snorers were much more aware of their symptoms such as snoring, irregular breathing, and apnea than were patients with OSA. Bed-partners of simple snorers were also more aware of the participants' sleep symptoms than were partners of patients with OSA. However, the duration of OSA symptoms was longer in the OSA group. In the correlation analysis, the level of awareness of OSA symptoms was negatively correlated with AHI, age, body mass index, and Epworth Sleepiness Scale score. Among the sleep questionnaire and polysomnography results, only Pittsburgh Sleep Quality Index was positively correlated with level of awareness of OSA symptoms. The minority of the respondents had heard about the treatment methods of continuous positive airway pressure and oral appliance and preferred them as treatment options. Conclusion: This study suggests that simple snorers are more aware of their symptoms than are patients with OSA. A higher severity of OSA, represented by a higher AHI, is correlated with lower awareness of one's OSA symptoms.

A Study on the Intelligent Service Selection Reasoning for Enhanced User Satisfaction : Appliance to Cloud Computing Service (사용자 만족도 향상을 위한 지능형 서비스 선정 방안에 관한 연구 : 클라우드 컴퓨팅 서비스에의 적용)

  • Shin, Dong Cheon
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.3
    • /
    • pp.35-51
    • /
    • 2012
  • Cloud computing is internet-based computing where computing resources are offered over the Internet as scalable and on-demand services. In particular, in case a number of various cloud services emerge in accordance with development of internet and mobile technology, to select and provide services with which service users satisfy is one of the important issues. Most of previous works show the limitation in the degree of user satisfaction because they are based on so called concept similarity in relation to user requirements or are lack of versatility of user preferences. This paper presents cloud service selection reasoning which can be applied to the general cloud service environments including a variety of computing resource services, not limited to web services. In relation to the service environments, there are two kinds of services: atomic service and composite service. An atomic service consists of service attributes which represent the characteristics of service such as functionality, performance, or specification. A composite service can be created by composition of atomic services and other composite services. Therefore, a composite service inherits attributes of component services. On the other hand, the main participants in providing with cloud services are service users, service suppliers, and service operators. Service suppliers can register services autonomously or in accordance with the strategic collaboration with service operators. Service users submit request queries including service name and requirements to the service management system. The service management system consists of a query processor for processing user queries, a registration manager for service registration, and a selection engine for service selection reasoning. In order to enhance the degree of user satisfaction, our reasoning stands on basis of the degree of conformance to user requirements of service attributes in terms of functionality, performance, and specification of service attributes, instead of concept similarity as in ontology-based reasoning. For this we introduce so called a service attribute graph (SAG) which is generated by considering the inclusion relationship among instances of a service attribute from several perspectives like functionality, performance, and specification. Hence, SAG is a directed graph which shows the inclusion relationships among attribute instances. Since the degree of conformance is very close to the inclusion relationship, we can say the acceptability of services depends on the closeness of inclusion relationship among corresponding attribute instances. That is, the high closeness implies the high acceptability because the degree of closeness reflects the degree of conformance among attributes instances. The degree of closeness is proportional to the path length between two vertex in SAG. The shorter path length means more close inclusion relationship than longer path length, which implies the higher degree of conformance. In addition to acceptability, in this paper, other user preferences such as priority for attributes and mandatary options are reflected for the variety of user requirements. Furthermore, to consider various types of attribute like character, number, and boolean also helps to support the variety of user requirements. Finally, according to service value to price cloud services are rated and recommended to users. One of the significances of this paper is the first try to present a graph-based selection reasoning unlike other works, while considering various user preferences in relation with service attributes.