• Title/Summary/Keyword: apparent power

Search Result 273, Processing Time 0.028 seconds

Characteristics of Noise Emission from Wind Turbine Generator According to Methods of Power Regulation (파워 조절 방법에 따른 풍력 터번 발전기의 방사 소음 특성)

  • Jung, Sung-Soo;Cheung, Wan-Sup;Shin, Su-Hyun;Chun, Se-Jong;Choi, Yong-Moon;Cheong, Cheol-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.941-945
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and fun span pitch control. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbine generators (WTG) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. It is found that while 1.5 MW WTG using the stall control is found to emit lower sound power than 660 kW one using the pitch control at low wind speed (below 8 m/s), sound power from the former becomes greater than that of the latter in the higher wind speed. Equivalent continuous sound pressure levels (ECSPL) of the stall control type of WTG vary more widely with wind speed than those of the pitch control type of WTG These characteristics are believed to be strongly dependent on the basic difference of the airflow around the blade between the stall regulation and the pitch control types of WTG. These characteristics according to the methods of power regulation lead to the very different noise emission characteristics of WTG depending on the seasons because the average wind speed in summer is lower than the critical velocity over which the airflow on the suction side of blade in the stall types of WT are separated. These results propose that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

  • PDF

Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period (1년 양생된 고강도 원전 콘크리트의 염화물 확산에 대한 균열 및 시간효과)

  • Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.

Rheological Properties of Chestnut Starch Solution (밤전분 수용액의 리올로지 특성)

  • Park, Hong-Hyun;Kim, Sung-Kon;Pyun, Yu-Ryang;Lee, Shin-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.815-819
    • /
    • 1989
  • Rheological properties of chestnut starch suspensions (3 and 4%, db) and gelatinized starch (4%, db) were investigated with a capillary and rotational viscometer, respectively. Starch suspensions had no yield stress and showed dilatant flow behavior in the temperature ranges of $30-65^{\circ}C$. However, starch suspension showed pseudoplastic flow behavior at $70^{\circ}C\; and\;above\; 65^{\circ}C$ for 3 and 4% concentration, respectively Flow activation energy below $50^{\circ}C$ was 0.56 kcal/mole but increased to 51.9-80.8 kcal/mole at $60-70^{\circ}C$. The behavior of gelatinized starch (4%) was pseudoplastic regardless of heating temperature $(65-80^{\circ}C)$ and time (15-60 min). The apparent viscosity of the starch remained constant after heating at $80^{\circ}C$ for 45 min. The swelling power and log apparent viscosity showed similar pattern. The activation energy of the apparent viscosity of the geletinized starch at $70-80^{\circ}C$ was 13.09kcal/mole. The apparent viscosity of thermal-gelatinized $(90^{\circ}C)$ starch was lower than that of 15 psi-gelatinized starch.

  • PDF

Field Test and Evaluation of Wind Turbine Noise according to IEC Standards (IEC 규격에 따른 풍력 터빈 소음의 현장 실증)

  • Cheong, Cheol-Ung;Jung, Sung-Su;Cheung, Wan-Sup;Shin, Soo-Hyun;Chun, Se-Jong;Lee, Sang-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Removal of Flooding in a PEM Fuel Cell at Cathode by Flexural Wave

  • Byun, Sun-Joon;Kwak, Dong-Kurl
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.104-114
    • /
    • 2019
  • Energy is an essential driving force for modern society. In particular, electricity has become the standard source of power for almost every aspect of life. Electric power runs lights, televisions, cell phones, laptops, etc. However, it has become apparent that the current methods of producing this most valuable commodity combustion of fossil fuels are of limited supply and has become detrimental for the Earth's environment. It is also self-evident, given the fact that these resources are non-renewable, that these sources of energy will eventually run out. One of the most promising alternatives to the burning of fossil fuel in the production of electric power is the proton exchange membrane (PEM) fuel cell. The PEM fuel cell is environmentally friendly and achieves much higher efficiencies than a combustion engine. Water management is an important issue of PEM fuel cell operation. Water is the product of the electrochemical reactions inside fuel cell. If liquid water accumulation becomes excessive in a fuel cell, water columns will clog the gas flow channel. This condition is referred to as flooding. A number of researchers have examined the water removal methods in order to improve the performance. In this paper, a new water removal method that investigates the use of vibro-acoustic methods is presented. Piezo-actuators are devices to generate the flexural wave and are attached at end of a cathode bipolar plate. The "flexural wave" is used to impart energy to resting droplets and thus cause movement of the droplets in the direction of the traveling wave.

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

Experimental Study on Power Improvement of a Flapping Tidal Stream Turbine by Mimicking a Manta-Ray (쥐가오리 모방 진동식 조류 터빈의 출력향상에 대한 실험적 연구)

  • Ko, Jin Hwan;Kim, Jihoon
    • Ocean and Polar Research
    • /
    • v.39 no.4
    • /
    • pp.293-300
    • /
    • 2017
  • Various approaches have been tried in an effort to improve the power performance of a flapping tidal stream turbine after it was introduced as an alternative to conventional rotary turbines. Among the different approaches, researches on mimicking the morphology and behavior of animals have been conducted. In this study, we utilized a flapper to mimic the multi-joint pectoral fin of a Manta-ray and investigated its effect on power generation. Experiments were conducted by a dual flapping apparatus with rigid and flexible flappers in a towing tank facility. First, in order to determine the conditions that can produce high power generation, the performances of the dual rigid flappers were compared when input arm angles and frequencies are changed, and the two conditions $40^{\circ}$, 0.2 Hz and $40^{\circ}$, 0.3 Hz for the input arm angle, frequency were selected. When the mimicked flexible flapper was used instead of the front rigid flapper and the rear one, the power was improved by an average of 22% and 38% in the experimental conditions, respectively. Moreover, it was recognized from the apparent camber observed during the experiment that the flexible flapper had been successfully applied. If the feasibility of the Manta-Ray mimicked flapper is improved through subsequent researches, the flapping tidal turbine can be a viable alternative to rotary turbines in the near future.

Development of Equipment to Measure Insulation Resistance and Evaluate the Lifetime of High-voltage Cable in Operation (운전 중인 고전압 케이블의 절연저항 측정 및 수명평가장치의 개발)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.237-242
    • /
    • 2014
  • In this paper, we find out the lifetime index in order to determine the time-dependent trend of deteriorating performance of 6.6kV high-voltage power cable in operation at a power station. The cable systems used in our study have been in operation for 13 years. With measurements for the 13 years, we analyzed the insulation resistances. By developing measuring equipment (comprized mainly of transformer, temperature sensor, and LPF) operating by the three-phase electric power, we analyzed the changing characteristics of insulation resistance of power cable. In contrast to 22kV cables, 6.6 kV cables have thicker insulation. Therefore the characteristics of 6.6kV cables are different from that of 22kV cables. The study found that as time passes, the insulation resistance does not decrease continuously; it decreases to a certain value, then does not decrease any more and shows properties of oscillation. We could not detect the process of deterioration in the preceding twelve years. The cable system showed great stability so that deterioration was not apparent. In this case, it is not possible to measure the future life indices of power cables because the lifetime indices are not predictable

A Study on the Utility of Statistical Power Balance Method for Efficient Electromagnetic Analysis of Large and Complex Structures (복잡한 대형 구조물의 효율적인 전자파 해석을 위한 통계적인 PWB 방법의 유용성에 관한 연구)

  • Lee, Young-Seung;Park, Seung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.189-197
    • /
    • 2013
  • With the trend of technological advances in electronic communications and the advent of ubiquitous environments, the density of existing electronic equipment in the surroundings is increasing significantly. It is hence great importance to study the numerically efficient and fast algorithm for complex and large environments to identify their electromagnetic compatibility and interference characteristics of equipments installed in those structure. This paper introduces a statistical-based power balance method(PWB) for the analysis of these problems and considers its practical utility. The 2-dimensional lossy rectangular cavity was numerically revisited to clarify its relationship with the classical deterministic analysis solutions based on the Maxwell's equation. It can be shown that the statistical assumptions and analysis results from the power balance method correspond to the volume average over the realistic deterministic domain. This statistical power balance approach should be a sufficiently practical alternative to the electromagnetic problem of complex and large environment since it is apparent that the full-wave analysis methods have some severe limits of its computational burdens under the situation of complex and large environment.

Effect of water content on near-pile silt deformation during pile driving using PIV technology

  • Jiang, Tong;Wang, Lijin;Zhang, Junran;Jia, Hang;Pan, Jishun
    • Geomechanics and Engineering
    • /
    • v.23 no.2
    • /
    • pp.139-149
    • /
    • 2020
  • Piles are widely used in structural foundations of engineering projects. However, the deformation of the soil around the pile caused by driving process has an adverse effect on adjacent existing underground buildings. Many previous studies have addressed related problems in sand and saturated clay. Nevertheless, the failure mechanism of pile driving in unsaturated soil remains scarcely reported, and this issue needs to be studied. In this study, a modeling test system based on particle image velocimetry (PIV) was developed for studying deformation characteristics of pile driving in unsaturated silt with different water contents. Meanwhile, a series of direct shear tests and soil-water characteristic curve (SWCC) tests also were conducted. The test results show that the displacement field shows an apparent squeezing effect under the pile end. The installation pressure and displacement field characteristics are sensitive to the water content. The installation pressure is the largest and the total displacement field is the smallest, for specimens compacted at water content of 11.5%. These observations can be reasonably interpreted according to the relevant unsaturated silt theory derived from SWCC tests and direct shear tests. The variation characteristics of the soil displacement field reflect the macroscopic mechanical properties of the soil around the pile.