• 제목/요약/키워드: apparatus

검색결과 4,308건 처리시간 0.028초

기능적 전기 자극에 의한 족관절 근육 반응 (Reaction of Ankle Muscles by Functional Electrical Stimulation)

  • 정순일;오세환;김진오;박광훈
    • 한국소음진동공학회논문집
    • /
    • 제22권1호
    • /
    • pp.15-21
    • /
    • 2012
  • This paper deals with an experimental study on the reaction of muscles by functional electrical stimulation(FES) with the design and fabrication of an ankle reaction apparatus. The ankle reaction apparatus consists of a circuit part and a kinematic part, and it monitors reaction time for a particular angle of joint rotation according to FES. The experimental results showed that the change of the ankle rotation angle was linearly proportional to the change of the magnitude of FES. It also showed that the muscle's reaction time was constant no matter how large the magnitude of the stimulus. The results of this paper can be applied to develop an active-type walking-assistance robot.

광조형을 이용한 마스크리스 패턴형성에 관한 연구 (A Study of Mastless Pattern Fabrication using Stereolithography)

  • 정영대;조인호;손재혁;임용관;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.503-507
    • /
    • 2002
  • Mask manufacturing is a high COC and COO process in developing of semiconductor devices, because of the mass production tool with high resolution. Direct writing has been thought to be one of the patterning method to cope with development or small-lot production of the device. This study focused on the development of the direct, mastless patterning process using stereolithography tool for the easy and convenient application to micro and miso scale products. Experiments are utilized by three dimensional CAD/CAM as a mask and photo-curable resin as a photo-resist in a conventional stereo-lithography apparatus. Results show that the resolution of the pattern was achieved about 300 micron because of complexity of SLA apparatus settings, inspite of 100 micro of inherent resolution. This paper concludes that photo resist and laser spot diameter should be adjusted to get finer patterns and the proposed method is significantly feasible to mastless and low cost patterning with micro and miso scale.

  • PDF

가연성물질의 자연발화온도 측정 및 예측 - 메탄올과 에탄올 - (Measurement and Prediction of Autoignition Temperature(AIT) of Flammable Substances - Methanol and Ethanol -)

  • 하동명
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.54-60
    • /
    • 2004
  • Flammable substances are frequently used chemical industry processes. An accurate knowledge of the ALTs(Autoignition Temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, ignition delay. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for methanol and ethanol. The A.A.P.E.(Average Absolute Percent Error) and the A.A.D.(Average Absolute Deviation) of the experimental and the calculated delay times by the AITs for methanol were 14.59 and 1.76 respectively. Also the A.A.P.E. and the A.A.D. of the experimental and the calculated delay times by the ATIs for ethanol were 8.33 and 0.88.

다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의 (The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance)

  • 박영배;이호재;허웅
    • 대한한의학회지
    • /
    • 제16권1호통권29호
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Real-time Temporal Characterization and Performance Optimization of a kHz Femtosecond Ti:Sapphire Laser Using a Comprehensive SPIDER

  • Luu, Tran Trung;Park, Ju-Yun;Lee, Jae-Hwan;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • 제14권2호
    • /
    • pp.146-151
    • /
    • 2010
  • A comprehensive real-time spectral phase interferometry for direct electric field reconstruction (SPIDER) apparatus for characterizing femtosecond laser pulses is demonstrated. The SPIDER provides the temporal profiles of femtosecond laser pulses, reconstructed at the speed of 3.5 Hz, with parameters of the spectral phase such as group delay dispersion and third-order dispersion. The apparatus is applied successfully to optimize the spectral dispersion of a kHz femtosecond Ti:Sapphire laser by adjusting a grating compressor in real time.

Development of a Piezoelectric Ultrasonic Tooth-whitening Apparatus

  • Lee, Young-Jin;Paik, Jong-Hoo;Lee, Jeong-Bae;Choi, Seung-Jae
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권5호
    • /
    • pp.268-272
    • /
    • 2013
  • The aim of this study was to develop an ultrasonic tooth-whitening apparatus using piezoelectric transducers, which enhance bleaching efficiency by applying ultrasound, while performing a teeth whitening procedure. For this purpose, an ultrasonic transducer was designed and manufactured, and the effects of reduction in the whitening material's concentration and in the whitening treatment time through using the ultrasound cavitation phenomenon were confirmed. Also, the validity of this study was investigated by comparing the whitening performance with a commercialized optical whitener, through color comparison. The results revealed that the ultrasound whitener produced color values that were enhanced by as much as double that of the conventional LED light whitening method. Even when the operational time was reduced by half, the ultrasound method showed superior performance by over 54% compared to the conventional light whitener, revealing that the ultrasound method showed a remarkable treatment reduction effect.

SCL 기반 디지털 변전소 이벤트 기록장치 설계 (Apparatus Design for event record of digital substation based on SCL)

  • 이남호;조영익;장병태;안용호;황갑철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.60-62
    • /
    • 2007
  • This paper presents apparatus and its method for event record of digital substation based on SCL files, which can save communication messages of a variety of IEC61850 international standard applied substation events such as fault. In particular, the device has ability to analyze all of the events and faults, and performs its functions based on SCL files.

  • PDF

원통연삭가공시 레이저 빔을 이용한 금속 표면거칠기의 인프로세스 측정에 환한 연구 (A Study on the In-process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Laser Beam)

  • 김희남;윤여권;이주상;김대욱
    • 한국안전학회지
    • /
    • 제9권3호
    • /
    • pp.41-52
    • /
    • 1994
  • This paper deal with the design of noncontact In-process measurement system which measures the surface roughness during cylindrical grinding. The measuring system is extremely simple and the apparatus proposed is composed of a laser unit, photodetector and optical system. The experimental performance of the apparatus is satisfactory and good results are expected in the actual use. During operation, the surface of a workpiece Is continuously scanned by a laser beam. The experimental results show that the presence of chattering, loading and glazing can be detected sensitively along both circumferential and feed directions and the surface roughness value is obtained from the reading along the feed direction.

  • PDF

진동형 분진 최소착화에너지측정장치에서 분진 응집현상이 미치는 영향 (Effects of the Powder Agglomeration on Vibrating Minimum Ignition Energy Measurement System for Powder)

  • 최광석;정재희;황명환;우인성;목연수;최충석
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.48-53
    • /
    • 1999
  • It is widely recognized that Hartmann tube for measuring the minimum ignition energy(MIE) of powder. But It requires long time and operational skills for measuring. As a variety of new fine powders are being produced day by day in industry, Japen has been developing a measurement system which employs a new method to create a dust/air mixture in a miniature combustion box. In this system, by vibration, the powder is successively fed downward through a hopper made up of metal mesh, and then it is formed into a thin, certain-like, dust/air mixture. With this new apparatus, three types of powder-Lycopodium, Anthraquinone, and Polyacry-lonitrile-were tested and the data of MIE were compared with those of a conventional apparatus (the Hartmann tube). Two of them agreed satisfactory, but the other, Anthraquinone, showed quite different values. It is guessed that the agglomerations of the powder particles appear because of particle shapes, static-charge and humidity.

  • PDF

옥내용 에폭시 수지의 열화 특성 (Degradation Properties of Epoxy Resin Used in Indoor)

  • 남기동;정중일;연복희;허창수;박영두
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2000
  • In this paper, study on the properties of the thermal degradated epoxy resin which is used in indoor insulation apparatus is performed to investigate the problems of the decreasing insulation characteristics and crack in the indoor insulation apparatus. As a parameter of variation, SEM, contact angle, surface resistivity, relative dielectric constant and weight loss are measured. As the results of the above measurements, the contact angle and surface resistivity of the epoxy resin has increased to 200$^{\circ}C$ in but at the above 200$^{\circ}C$ the values have decreased. The relative dielectric constants the thermal treated samples have increased on with the temperature increase. We find the volatile components of the epoxy resin compound has disappeared during thermal degradation by SEM. The insulation properties of the epoxy resin have increased by the 200$^{\circ}C$ but decreased in the above 200$^{\circ}C$.

  • PDF