• Title/Summary/Keyword: apparatus

Search Result 4,314, Processing Time 0.037 seconds

Development of the Program Road lighting Road Surface Property Measuring Apparatus (도로조명용 프로그램과 노면특성 장치의 개발)

  • ;金紀勳
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.133-133
    • /
    • 1999
  • Average illuminance and luminance can be calculated by graphical methods to a certain extent but to calculate for a wide place a suitable software is needed. Softwares suitable for this purpose have been already developed in foreign nations, but the appropriate softwares for domestic use have not been developed. Therefore a program is developed which is executable in Hangul Windows. The softwares LAPRoad, is developed to calculate luminance and illuminance distribution of road surface, as well as average luminance and illuminance, overall uniformity, longitudinal uniformity, threshold increment veilling luminance and glare. And an apparatus that measures road surface reflection properties is developed. Because the road surface reflection properties is very important in luminance calculation, then concrete road surface reflection properties were measured.

An Apparatus for Containerless Melting and Solidification of Materials Via Electrostatic Levitation (정전기 부유 무용기 용해 및 응고 장비)

  • Sung, Y.S.;Kim, M.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.7
    • /
    • pp.439-444
    • /
    • 2006
  • An apparatus capable of melting and solidifying various materials containerlessly in high vacuum via electrostatic levitation (ESL) has been developed for finding materials with new or improved properties and further building a database for processing materials in microgravity. Containerless solidification of semiconductors, metals, and alloys such as Si, Zr, Nb, Mo, $V_3Si$, and boron carbides has been carried out to test how various materials at how high temperatures can be processed by ESL. The materials in levitation became spherical at melting by their own surface tensions which were ideal for measuring intrinsic thermophysical properties of materials in the liquid state. Multiple cycles of melting and cooling were reproducibly repeated and radiative cooling curves were recorded.

ON Salinity of Comduit Discharge from Selective Withdrawal Apparatus (선정된 배수관의 유출수 감분농도에 관한 연구)

  • 서영재;김진규
    • Water for future
    • /
    • v.25 no.2
    • /
    • pp.99-110
    • /
    • 1992
  • A problem of outlet salinity from a stratified fluid with a well developed interface thickness consisting of an upper and lower layer differing slightly in density is considered. Three kinds of apparatus were used for the experimental test and salinity differences between inlet layer and outlet discharge were estimated by the functional relationship using the dimensionless values. For the critical incipient condition of withdrawal of upper layer, Densimetric Froude number is correlated by the inlet diameter and depth ratio in the tank.

  • PDF

Experimental Study on Ignition of Flammable Gas by Spark of Dry Battery (건전지의 방전에 의한 폭발성 가스의 점화에 관한 실험적 연구)

  • Lee, Chun-Ha;Song, Hyun-Jig;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1543-1546
    • /
    • 1994
  • Ignitabilility of explosive gas mixture by spark of dry cell in case of short circuit by accident was studied for the purpose of evaluation of intrinsically safe characteristics of dry cell that manufactured in Korea. IEC type spark test apparatus, $21{\pm}2$ Vol% of hydrogen - air mixture, and dry cell that produced in Korea was used for the experiment. The result of this research could be used for design, manufacturing, and using the intrinsically safe electrical apparatus.

  • PDF

A Study of In Situ Hydraulic Conductivity Testing Equipments (현장투수시험 장치에 관한 비교 연구)

  • 김현기;권무남
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.612-617
    • /
    • 1999
  • This study was carried orut considering the aspect of economical and measuring time to investigate through the literature review of the test methods and advantage -disadvantage of infilltrometer and porous probe test apparatus. SSRI and BAT permeameter could obtain results within relatively short time and measure low permeability. SDRI is able to obtain values the accuracy and representative of the overall in-situ. BAT permeameter is to suitable because it can obtain the values accurately and quickly . Therefore the apparatus cost can be to disregard. In-situ measurement using in-situ hydralulic conductivity test equipment is able to do for the engineer to quickly identify and remediate problem areas due to construction or material changes.

  • PDF

A study on simplified Textile testing apparatus for teaching high school students (중고등학교 피복재료 학습효과를 높이기 위한 시험장치 개발에 관한 연구)

  • 장경연
    • Journal of the Korean Home Economics Association
    • /
    • v.26 no.2
    • /
    • pp.69-79
    • /
    • 1988
  • This study was to increase the experimental learning effect of textile materials in middle and high school. To this study, three kinds of simply devised apparatus were used for warmth retaining test, air permeability test and static electricity test. Two classes were chosen in a girls' high school comparing learning effect and classified the theoretical learning group and the experimental learning group. In the experimental group, a teaching plan to teach the properties of textile materials was made to use these apparatuses. The results were. 1. In the interest on the unit either the theoretical learning group or the experimental learning group were not different significantly. 2. In the items facilitation of motivation, unsatisfied desires and prevention of failure, effect of transfer and development of inquiry power, both groups were significant. 3. For the purpose of comparing the learning effect, two groups were examined for determining the level of understanding after teaching properties of textile materials. The mean value of the experimental learning group was higher than that of the theoretical learning group. The experimental learning group had more higher markers(over the point of 90) than the theoretical learning group.

  • PDF

Static Characteristic and Dynamic Characteristic Experiment of First-stage Proportional Pressure Control Valve (1단 비례 압력제어밸브의 정특성 및 동특성 실험)

  • Jeong, Heon-Sul;Nam, Ji-Woo;Lim, Hyo-Joon;Jung, Seung-Wook;Han, Sung-Min
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.18-24
    • /
    • 2010
  • Because of the increasing demand on the high precision and high response of a machinery, electronic control valves are widely adopted at various application fields. This paper studies on the static characteristic of a first-stage proportional pressure control valve. At first an experimental apparatus including hyd. pump variable speed inverter, pressure and data aquisition system was setted up with the experimental apparatus, various tests such as P-Q-W test, hyd, pump, dynamic, static, frequency response test of the proportional valve was carride out and the results are discussed.

  • PDF

A CONSIDERATION ON THE PULSE OXIMETRY FOR VITAL SIGN MONITORING (생징후감시를 위한 Pluse oximetry에 대한 임상적 고찰)

  • Kim, Shin;Chung, Tae-Sung;Park, Yang-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.887-892
    • /
    • 1996
  • For the purpose of assessing the utility and cautionary aspects of pulse oximetry of which use is rapidly increased, it was applied to the maladaptive child patients with sedative drugs and evaluated the results. When pulse oximeter was used alone for vital sign monitoring, it was thought impossible to exclude the false alarm or false silence by various causes. To minimize or remove these misunderstanding, operators should have a extensive knowledge not only on the factors affecting the operation of this apparatus but also on the potential of misoperation. To review the present status of increasing risk of hypoxia during the sedation, it was thought unreasonable to solely depend upon this apparatus for vital sign monitoring. By combining with more accurate and auxiliary monitoring devices, pulse oximetry will be of greater value and can meet the clinical needs and conveniences.

  • PDF

The Evaluation of CO Adsorbents Used in PSA Process for the Purification of Reformed Hydrogen (개질 수소 정제용 PSA 공정을 위한 CO 흡착제의 성능 평가)

  • PARK, JIN-NAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.628-635
    • /
    • 2016
  • Natural gas reformed hydrogen is used as a fuel of fuel cell vehicle, PSA process is used for the purification of reformed hydrogen. In this study, the performance of CO adsorbent in PSA process was evaluated. Zeolite adsorbents used in the commercial PSA process is used. The physical and chemical properties of adsorbents were characterized using BET apparatus, XRD, and FE-SEM. The breakthrough apparatus modified from GC was used for the CO breakthrough experiment, the quantitative analysis of CO adsorption capacity was performed using CO breakthrough curve. Zeolite 10X and 13X showed superior CO adsorption capacity than activated alumina. The CO adsorption capacity of zeolite 10X is more than twice of zeolite 13X even the BET surface area is low. It seems that the presence of $Ca^{2+}$ cation in zeolite 10X is beneficial to the adsorption of CO.

The estimation of uncertainty in new measuring system used for high-power tests (대전력시험의 새로운 측정시스템에 대한 불확도 평가)

  • Suh, Yoon-Taek;Kim, Maeng-Hyun;Kim, Dae-Won;Kang, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.540-542
    • /
    • 2003
  • In the high-power tests to be performed on electrical apparatus as circuit-breaker, load switch, fuse, transformers, insulators, cable and so on, the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper deals with factors of uncertainty and describes estimation of uncertainty in new measuring system used in high-power testing LAB. 1 in KERI.

  • PDF