• Title/Summary/Keyword: apparatus

Search Result 4,308, Processing Time 0.027 seconds

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

Novel Apparatus for Seawater Desalination and Its Application (신개념 해수담수 플랜트 적용을 위한 장치개발 및 적용기술)

  • Lee, Ju Dong;Kang, Kyung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.407-412
    • /
    • 2014
  • A new apparatus for seawater desalination, based on the principle of gas hydrates, is suggested. The equipment continuously produces and pelletizes gas hydrates by a squeezing operation in a dual cylinder unit, which is able to extract pure hydrate pellets from the seawater-containing reactor. Desalination efficiency for each dissolved ion from seawater samples was tested by inductively coupled plasma atomic emission spectroscopy (ICP-AES) and ion chromatography (IC) analysis. This study demonstrates that the suggested method and the stated apparatus may solve the difficulty of separating hydrate crystals from concentrated brine solutions, and therefore may be applied to improve the efficiency of existing desalination processes.

The Measurements of Ball Recovery Rate for the Cleaning Apparatus in Plate Heat Exchanger Using Ceramic Ball (세라믹 볼을 이용한 판형열교환기 세정장치의 볼 회수율 측정)

  • Chae, Hee-Man;Kwon, Jeong-Tae;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 2014
  • The objectives of this study are to measure the ball recovery rate of cleaning apparatus for plate heat exchanger. Ceramic ball is used for plate heat exchanger cleaning. The main components of cleaning apparatus are comprised of ball collector, ball trap, ejector, pump and plate heat exchanger. The ball recovery rate are obtained with change in recovery time and velocity of water. The results show that the ball recovery rate is slightly increased with increase in the recovery time and the velocity of water over 0.4 m/s in the straight flow. In the case of reverse flow, the ball recovery rate more increased than straight flow. The maximum ball recovery rate of the straight flow and reverse flow reach 83.97% and 86.61%, respectively, when the velocity and cleaning time are 0.5 m/s and 15min.

A Study on the Smoldering hazard of Rice bran dust. (쌀겨 분진의 훈소 위험성에 관한 연구)

  • 이창우;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.12-17
    • /
    • 1999
  • We intended to investigate combustion properties of rice bran dust. Combustion properties of h rice bran dust according to size distribution and amount were measured as temperature v variation with time using spontaneous ignition apparatus. Moreover, combustion properties w with blowing or without blowing condition were checked in order to investigate combustion p properties in spontaneous ignition apparatus according to flow condition of air. A As the mass and size of rice bran dust was increased, i띠ti외 smoldering temperature was l lowered. All of combustion forms were smoldering combustion. Initial smold얹ing temperature w was slightly lower with blowing condition than without blowing condition in spontaneous i ignition apparatus, which condition made heating value high.

  • PDF

A Study on Residual stress at Cutting work (절삭가공시 잔류응력에 관한 연구)

  • 주호윤
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.3
    • /
    • pp.111-117
    • /
    • 1997
  • The sudden-stop apparatus is made to measure the residual stress of the infinitesimal area at the turning work surface by using the X-ray stress apparatus. This study is trued to make the cutting work the instantaneous stopping state in the normal working state. The behaviour of work material near the tool is estimated. The estimation method is that the distribution of residual stress can be also measured. The object is to clarify and control the mechanism to leave the adequate stress of the finishing surface. It's beginning is due to observe the occurrence state of the residual stress at the cutting work. The result obtained by this study is as follows. The chips are not separated from the work materials at all the cutting experiments of built-up edges or the shearing areas etc. which can be precisely observed by using the sudden-stop apparatus. The strain of movable system which can be seen at the part of working layer means the size of strain. This experiment proves that the working strain should be lessened to make the size of strain control the residual stress happened at the cutting surface.

  • PDF

Development of One PC-Based the Haptic Interface and Tactile Apparatus System (단일 PC기반의 역감 및 촉감 제시 시스템 개발)

  • 김동옥;류재민;김영동
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.2
    • /
    • pp.217-226
    • /
    • 2004
  • This paper proposes the electric stimulus tactile apparatus system(TESTAS) loaded on the haptic interface using ultrasonic motors (USMs) To touch the virtual object like wall in graphic, the 6 DOF haptic interface provides force feedback to users as if it is real. But the case of sharp virtual object like a puncture, it could not provided the sense of pain, but only the reaction-force. After the TESTAS had been loaded on this haptic interface, it could provide not only the force but also the pain to users. In this way, when users take the haptic and tactile informations at the same time, they easily have a correct understanding of virtual object.

  • PDF

High strain rate tensile test of sheet metals with a new tension split hopkinson bar (새로운 Tension Split Hopkinson Bar를 이용한 박판의 고속 인장시험)

  • Kang, Woo-Jong;Cho, Sang-Soon;Huh, Hoon;Jung, Dong-Taek
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.2209-2219
    • /
    • 1997
  • A split hopkinson bar could be used for obtaining the high strain rate material properties of sheet metals for an autobody. In high speed tensile tests of sheet matals, a new design of a tension split Hopkinson bar apparatus is needed. The design of grips and an anvil length are numerically analyzed with ABAQUS/Explicit for the new apparatus of split Hopkinson bars. From the experiments with the new apparatus, the material properties of SPCEN in the high strain rate state have been acquired and compared with quasi-static experimental results. The material properties of SPCEN as well as other sheet metals in an autobody are indispensible for the analysis of crashworthness. Nevertheless the experiment of sheet metal in the high strain rate state has not been done or reported.

Development of Expert System to Diagnose and Monitor 765KV Power Apparatus in On-line Condition (765KV 변전설비 운전중 상태감시 및 진단을 위한 전문가시스템 개발)

  • Jeong, Gil-Jo;Choe, In-Hyeok;Kim, Gwang-Hwa;Gwak, Hui-Ro
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.11
    • /
    • pp.562-568
    • /
    • 2001
  • In this paper, we described the export system to monitor and diagnose 765KV power apparatus. To develop this expert system, we studied the knowledge bases and data bases for 765KV transformer and GIS. In order to make the reliable inference of knowledge base and the good MMI(Man Machine Interface), the data bases were consisted of the tables of power apparatus information, limit level value, measured input data, inference result and diagnosis result. The knowledge base had various rules to infer the conditions of transformer and GIS. We applied both the forward chaining and backward chaining methods to these rules of system for good inferences. This paper describes the applied methods for expert system. Also, this developed system was tested with dissolved gas analyzing result and the result was shown.

  • PDF

An Experimental Study on the Performance Characteristics of the Vortex Tube for Substitution of the Intercooler in a Common-rail Diesel Engine (커먼레일 디젤기관의 인터쿨러 대체용 볼텍스 튜브 장치의 성능특성에 관한 실험 연구)

  • Im, Seok-Yeon;Choi, Doo-Seuk;Ryu, Jeong-In
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.172-178
    • /
    • 2008
  • An object of this study is to confirm performance characteristics of the vortex tube apparatus for substitution of the intercooler in a common-rail diesel engine. The turbo pressure, the intake air flow rate and the ${\Delta}T_c$ decrease ratio of the intercooler were measured in a experimental engine. The vortex tube apparatus was made after confirmation of the geometric phenomena in fundamental experiments. To investigate energy separation characteristics of the vortex tube, the measured turbo pressure was applied to the vortex tube inlet and the ${\Delta}T_c$ decrease ratio was compared with one of the intercooler in the cold air mass flow ratio similar to the intake air flow rate of the experimental engine. From the results, we found that the energy separation ratio is increased according to of the inlet pressure and the ${\Delta}T_c$ decrease ratio of the vortex tube apparatus is higher than one of the intercooler at low engine speed and engine load of medium and low.

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF