Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

  • Kim, Pil-Jong;Kim, Hong-Gee;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.113-122
    • /
    • 2015
  • Objectives: The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). Materials and Methods: The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results: Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions: Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도 (The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement)

  • 이병립;박창서
    • 치과방사선
    • /
    • 제28권2호
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

2종 전자근관장측정기의 일관성에 관한 in vitro 연구 (IN VITRO EVALUATION OF THE CONSISTENCY OF TWO ELECTRONIC APEX LOCATORS)

  • 황규용;노병덕;김의성;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제33권1호
    • /
    • pp.20-27
    • /
    • 2008
  • 정확한 근관장 측정은 성공적인 근관치료를 위해 필수적이다. Kuttler는 근관협착부는 주근단공에서 0.5 mm 상방에 위치한다고 하였고 Lee는 상아백악질 경계점부위보다 주근단공이 재현성이 높고 임상적으로 관찰하기 용이하다고 보고하였다. 본 연구는 alginate model상에서 2개의 전자근관장측정기를 사용하여 얻은 측정치의 정확성(accuracy)을 평가하고 각각 0.5 mark와 Apex mark 중에서 어느 지점에서 더 일관성(consistency)을 보이는지를 비교하고 또한 근관장을 측정할 때 파일을 전진시키면서 Apex mark를 측정한 값과 치근단부위를 지나친 후 다시 후퇴하면서 측정한 값의 차이를 비교하고자 하였다. 52개의 발거된 건전한 제 1, 2소구치를 대상으로 하였으며 Root ZX와 E-Magic Finder Deluxe를 이용하여 각각 26개중 13개는 파일을 전진하면서 0.5 mark에서 근관장을 측정하고 Apex mark에서 근관장을 측정한 후 0.5 mark에서 고정하였다. 나머지 13개는 0.5 mark에서 근관장을 측정한 후 Apex mark에서 근관장을 측정하고 다시 치근단 부위를 넘어선 후 후퇴하면서 Apex mark에서 근관장을 측정하고 고정한 후 치근단부 4 mm를 삭제하여 현미경상에서 파일 끝부터 주근단공까지의 거리를 측정하였다. 그 결과 Root ZX와 E-Magic Finder 모두, 실험군 100%에서 주근단공과 file tip간의 거리가 임상적 허용범위인 ${\pm}0.5\;mm$내에 있었으며 0.5 mark보다 Apex mark에서 더 높은 일관성을 보였다. 주근단공에서 fie tip사이의 거리는 Root ZX의 0.5 mark에서 -0.18 mm, Apex mark에서 -0.07 mm이고 E-Magic Finder의 0.5 mark에서 -0.25 mm, Apex mark에서 -0.02 mm를 나타내었다. Apex hand는 0.04 mm였다. 따라서 Alginate model을 사용한 본 실험조건에서는 Apex mark에서 근관장을 측정한 결과 거의 주근단공과 일치하고 다른 여러 연구에서 주근단공에서 0.5 mm상방에 근관협착부가 위치한다고 보고하였으므로 임상적인 측면에서 Apex mark에서 측정한 근관장에서 0.5 mm를 빼서 근관장으로 사용하는 것이 임상적으로 더 좋으리라고 사료된다.

재배양식(栽培樣式)에 따른 벼와 피의 생장(生長) 및 해부형태학적(解剖形態學的) 차이(差異) - IV. 재배양식(栽培樣式)에 따른 제초제(除草劑) Butachlor에 대(對)한 벼와 피간(間)의 해부형태학적(解剖形態學的) 반응(反應) 차이(差異) (Morphological Characteristics of Growth of Rice and Barnyardgrass under Various Cropping Patterns - IV. Difference in Morphological and Anatomical Response to Butachlor)

  • 천상욱;구자옥;김용재
    • 한국잡초학회지
    • /
    • 제14권3호
    • /
    • pp.199-211
    • /
    • 1994
  • 다양(多樣)한 재배양식(栽培樣式), 건답직파(乾畓直播), 담수직파(湛水直播) 및 이앙재배조건하(移秧栽培條件下)에서 제초제(除草劑) butachlor에 대한 벼와 피의 해부형태학적(解剖形態學的) 반응차이(反應差異)가 검토되었다. 파종(播種) 및 이앙(移秧)후 5일(日)째에 butachlor를 추천량(推薦量)의 배양(倍量)인 3,600g ai/ha를 토양처리(土壤處理)한 후(後) 10일 및 20일째에 외부형태(外部形態) 및 해부학적(解剖學的) 반응(反應)을 조사(調査)하였다. 1. 초장(草長)과 근장(根長)은 건답(乾畓)보다 담수조건(湛水條件)에서, 토중(土中)벼보다는 표면(表面)벼에서 억제정도(抑制程度)가 컸고 이앙(移秧)벼는 피해정도가 경미하였다. 2. 지상부생체중(地上部生體重)은 건답(乾畓)벼에서 무처리(無處理)에 대비(對比)하여 15% 미만, 피는 53% 억제되었으며 담수(湛水)벼는 70% 이상, 피는 94%로 크게 억제되었다. 지상부생체중(地下部生體重)은 담수상태(湛水狀態)에서만 벼와 피 모두 91% 이상 높은 억제율(抑制率)을 보였다. 3. 잎 형태변화(形態變化)도 건답(乾畓)에서의 피가 엽생장(葉生長)은 엽령(葉齡) 및 제(第) 1 엽(葉) 신장에서 경미(輕微)하게, 엽초장과 제(第) 2 엽(葉) 신장은 무처리(無處理)에 대비(對比)하여 30-50% 억제되었으나, 벼의 제(第) 2 엽(葉) 신장과 엽령(葉齡)은 6~42%와 6~29% 억제(抑制)되었다. 담수상태(湛水狀態)에서의 피는 100% 억제(抑制)되었고, 벼는 침엽기(針葉期)에 생육이 지연되었고, 이앙(移秧)벼는 제 1 엽초장만 23% 억제되었다. 4. 중경장(中莖長)은 담수(湛水)피가 무처리(無處理)에 대비(對比)하여 33%, 건답(乾畓)피는 57%까지 억제되었다. 5. 줄기횡단명(橫斷面)의 해부특징(解剖特徵)은 건답(乾畓)의 경우 피에서만 최외곽(最外廓)엽초의 두께 감소와 부분적 조직파괴(組織破壞)가 있었고, 담수(湛水)에서는 표면(表面)벼의 엽시원체(葉始原體) 두께 감소(減少)와 위축현상(萎縮現狀)이 있었고 토중(土中)벼는 세포(細胞)의 위축현상(萎縮現狀)이 나타났다. 담수(湛水)피는 엽시원체(葉始原體) 생장(生長)이 정지(停止)된 간엽(簡葉)을 형성하였다. 6. 줄기종단면(縱斷面)의 해부특징(解剖特徵)은 건답(乾畓)에서의 피와 담수조건(湛水條件)에서의 표면(表面)벼 및 피가 분제조직(分製組織)의 신장억제(伸長抑制)가 있었고 특히 담수(湛水)피에서 심하였다.

  • PDF

2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구 (In vivo evaluation of accuracy and consistency of two electronic apex locators)

  • 필감운;김의성;정일영;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.453-460
    • /
    • 2010
  • 연구목적: 치주질환이나 보철치료 계획으로 발치 예정인 성인 환자들을 대상으로 2 종의 전자근관장측정기를 사용하여 얻은 측정치의 정확성 (accuracy)을 평가하고, 현미경을 사용하여 각각 0.5 mark와 Apex mark 중에서 어느 지점에서 더 일관성 (consistency)을 보이는지를 비교하는 것이다. 연구 재료 및 방법: 치주 및 보철치료계획으로 인해 발거 예정인 26개의 건전한 치아들에서 13개는 Root ZX를 이용하여 측 정하였고, 나머지 13개는 i-ROOT를 이용하여 측정하였다. 국소마취를 시행 후 러버댐을 적용한 후 치아의 치수강을 개방하였다. 이때 교합면을 치아 장축에 수직으로 삭제함으로써 근관장을 측정할 때 발생할 수 있는 오차를 최소화하였다. 모든 근관에서 0.5 mark에서 먼저 근관장을 측정한 후 file을 더 전진하여 Apex mark에서 근관장을 다시 측정하였고, 이 지점에서 file을 Light cured glass ionomer로 고정하였다. 이후 치아들을 발거한 후 생리식염수에 보관하였다. 각각 치아들의 치근단부 5 mm를 21.3배율의 현미경 하에서 치근의 장축 방향으로 고속핸드피스 다이아몬드 바를 사용하여 조금씩 삭제하여 치질을 조심스럽게 제거하여 file tip을 완전히 노출시켰다. 현미경 하에서 진행한 과정들은 현미경과 연결된 DVD recorder를 통해 저장하였다. 이 이미지를 영상분석 프로그램인 i-solution에 적용하여 file tip에서부터 주근단공까지의 최단거리를 측정하였다. 결과: 1. Apex mark 이용 시 Root ZX와 i-ROOT 모두에서 주근단공 ${\pm}0.5\;mm$ 이내의 부위를 100% 찾아내는 정확도를 보였다. 2. 0.5 mark 이용 시 Root ZX에서는 100%, i-ROOT에서는 77%에서 주근단공 ${\pm}0.5\;mm$ 이내의 부위를 찾아내는 정확도를 보였다. 3. 표준편차와 사분위 값으로 평가하였을 때 Root ZX에서는 Apex mark가 0.5 mark보다 일관성을 나타냈으며 i-ROOT에서는 0.5 mark가 Apex mark보다 일관성을 보였으나 t-test 결과에서는 통계적 유의차가 없었다. 4. Apex mark와 0.5 mark 차이는 Root ZX에서는 0.22 mm, i-ROOT에서는 0.46 mm를 보였다. 결론: Apex mark와 0.5 mark 모두 일관성에 있어서의 차이는 없으나 Apex mark의 측정치가 0.5 mark에 비하면 주근단공에 거의 일치하는 점을 고려해, 임상에서 근관장을 결정할 시 Apex mark 측정치를 먼저 구한 후 기존연구들에서 보고된 주근단공에서부터 근관협착부까지의 평균거리인 0.5 mm를 빼는 것이 좋을 것으로 사료된다.