• 제목/요약/키워드: apartment energy consumption

검색결과 175건 처리시간 0.023초

$\cdot$$\cdot$주별 열에너지 소비절약 실태에 관한 조사연구 (An Exploratory Study of Energy Conservation Practices in Clothing, Food, and Housing)

  • 강혜원
    • 대한가정학회지
    • /
    • 제19권2호
    • /
    • pp.11-24
    • /
    • 1981
  • The objectives of the study were to determine 1) if energy consumption and conservation vary in clothing, food, and housing with independent variables-size of household, homemaker's age, employment, and level of education, level of living, type of house, electricity use, and all energy use, and 2) if there is a correlation among energy conservation practices in clothing, food, and housing. Questionnaires wee given to the randomly selected homemakers in Seoul in July, 1980. Data from 620 responses were analyzed by F-test (Analysis of Variance) and Correlation. The results are as follows: 1. Clothing (1) the scores of the conservation practices I clothing were generally high. /However, it was found that a) they did not practice in wearing heavy under clothes and behavior outer clothing to cope with cool room temperature in the winter, b) they did not use bleach for laundry, but they used boiling method, and c) they did not have enough knowledge on Permanent Press finish. (2) energy conservation practices in clothing were significantly related to level of living and homemakrer's level of education. a) The higher the level of living, the higher scores in the knowledge were found. b) the higher the homeakcer's level of education, the higher scores in the knowledge and ironing were obtained. 2. Food (1) The scores of the conservation practices in food were generally high. However, it was found that scientific cooking methods were not performed such as a) to use measuring spoons, cups, and timers, b) to practice a simple method in using solor energy for warming water, c) to use thermos for the hot water tea or coffee, but they boiled water whenever necessary, and b) to use the pressure cooker whenever possible. (2) Energy conservation practices in food were significantly related to homemaker's employment and type of dwellings. a) The scores of full-time homemakers (not gainfully employed) were higher than gainfully employed homemakers. b) Families in traditional Korean dwellings revealed higher scores than those in apartment or western style dwellings. 3. Housing (1) The scores of the conservation practices in housing were generally high. However, it was found that a) they did not install fans in the kitchen, bathroom, and attic in the summer, b) they did not install a humidifier for tolerating a lower room temperature in the winer, c) they did not practice to make plans for the door of the refrigerator remained open for the shortest time, d) they did not install or use a local lighting with a general lighting for reading and cooking, and e) they usedaluminum foil without the knowledge of the heat reaction of its shiny and dull sides. (2) energy conservation practices in housing were significantly related to homemaker's employment and level of education, economic status, types of dwelling, and all energy use, a) Full-time homeakers had higher scores than gainfully employed homeakers. b) the higher the homemaker's level of education and economics status, the higher scores were obtained. c) Homeakers with their own house scored higher points than those with rented houses. And families in apartment or row houses scored higher points than those in traditional korean or western style dwellings. d) The higher the consumption rate of electricity and all energy, the higher scores were revealed. 4. correlation there was a significant correlation among energy conservation practices I clothing, food, and housing.

  • PDF

공동주택 전과정평가 프로그램(SUSB-LCA ver1.0) 개발에 관한 연구 (Study on the Development of the Life Cycle Assessment Program in the Apartment Housing)

  • 이하식;정보라;최영오;채창우;이강희
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.393-398
    • /
    • 2008
  • The environment is the important resource to use as well as to conserve for the development. Since 1990s, it has accentuated the importance of the environment and tried to conserve the environment in many areas. Among many area, the building industry has played a role to destruct the environment for providing the living decent space and brought the environmental affect. Therefore, the building industry should endeavor to mitigate the environmental affect. In building life cycle, it consumes the energy and natural resources. But it is difficult to evaluate the environmental affect during the whole building life. It is impossible to calculate the environmental affect without the much time and effort. Therefore. it requires the easy and handing program to calculate the affect to environment in each building life cycle. Until now, many program for assessing the affect to the environment have been developed and limitedly used because of the assessment scope and contents. In this paper, it aimed at developing the assessment program of LCA, focused on the energy consumption and carbon-dioxide emission compared with the domestic and foreign concerned programs. The developed program is divided into 3 areas; construction, maintenance, demolition.

  • PDF

공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구 (A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field)

  • 문출성;오세규;조성우
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

옥상녹화에 따른 공동주택 에너지 저감효과 분석 연구 (An Analysis of Energy Reduction Effects in Housing According to Green Roof)

  • 김지현;손형민;권혁삼;김정곤;이범식
    • 토지주택연구
    • /
    • 제7권4호
    • /
    • pp.299-305
    • /
    • 2016
  • 본 연구는 기후변화 대응을 위한 계획적 수단으로서 옥상녹화에 따른 건축물 에너지 저감효과를 분석하여 옥상녹화 적용확대를 위한 기초자료를 제시하는데 목적이 있다. 대상지는 최근 준공된 공동주택 중 옥상녹화가 적용된 주동과 부대복리시설을 선정하였다. 건축 유형에 따라 경량형(토심 20cm) 및 혼합형(토심 40cm) 옥상녹화를 적용하고, 디자인 빌더(Design Builder)를 활용하여 옥상녹화 적용에 따른 에너지 저감량을 비교 분석하였다. 분석결과, 모든 대상 건축물에서 옥상녹화 적용시 에너지 저감효과가 있으며, 혼합형 옥상녹화가 경량형 옥상녹화에 비해 냉 난방 에너지 저감효과가 더 큰 것으로 나타났다.

로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구 (A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing)

  • 이나은;안병립;장철용;이승복
    • 한국태양에너지학회 논문집
    • /
    • 제32권2호
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구 (Study on PCM Applied Thermal Storage Wall System to Reduce Cooling Energy)

  • 이규영;류리;서장후;김용성
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.247-256
    • /
    • 2014
  • The regulations to reduce energy consumption and carbon dioxide emission in building sectors are being developed and promoted all over the world. However, in Korea, as balcony extension of the apartments has been legally allowed, it became prevalent and resulted in excessive energy consumption. This study derived the possibility of PCM application to the thermal storage wall system through theoretical consideration and investigated the problems occurring when the balcony space has been extended to the diverted space. In addition, this study aims at the possibility of verifying the installation and confirming the cooling energy reduction effect, by conducting measuring tests with the actual installation of PCM applied thermal storage wall system. As a result of theoretical consideration, it is determined that the disadvantages with the existing thermal storage wall system can be complemented by applying PCM, and this study suggests the PCM applied Thermal Storage Wall System. The study was conducted on 1/6 of a miniature inner room of a domestic apartment with 84 $m^2$ of exclusive area. From the results of actual measurements, it is confirmed that the balcony extension structure can gain 11.3% of more calories than the existing balcony structure, resulting in the increase in cooling energy usage. It is determined that the installation of the PCM applied Thermal Storage Wall System may gain 25.2% of less calories to reduce cooling energy usage.

연안지역 아파트의 전력소비량 실태조사 - 부산광역시 영도구에 대한 사례연구 - (A Survey on the Electric Power Consumptions of Apartments located at Coastal Area : Yeongdo-gu, Busan, Korea)

  • 황광일
    • 한국항해항만학회지
    • /
    • 제33권3호
    • /
    • pp.241-245
    • /
    • 2009
  • 도심지의 열섬(Heat Island)현상과 연안지역의 해풍(海風)의 영향 때문에, 부산, 인천, 목포 등 연안도시의 도심지역과 연안지역의 각 외기 상태가 서로 다르게 나타난다. 이러한 외기조건은 건물의 냉방부하, 난방부하, 전력소비량 등에 직접적인 영향을 미치기 때문에, 에너지절약을 위한 건물설계와 운전방법개발을 위해서는 각 지역에 위치한 건물의 에너지소비특성을 파악해야만 한다. 본 연구에서는 연안지역 아파트의 전력소비량에 주목하였고, 부산광역시 영도구에 위치한 세대수가 100세대 이상인 22개 아파트 단지를 대상으로 기간별, 기능별 전력소비량을 조사하였다. 22개 아파트 전체의 세대내 최대전력소비량은 8월에 발생하고 있으나, 공용 최대전력소비량은 1월에 발생하고 있음을 알수 있었다. 한편 연안지역에서는 여름철에 해풍에 의한 자연환기로 인해 냉방용 전력소비가 감소할 것으로 예상하였으나, 조사결과에서는 여름철에 최대부하가 발생하였는데, 이는 해풍에 포함된 염분의 피해를 예방하기 위해 창문을 닫고 전기구동 에어컨으로 냉방하기 때문인 것으로 파악되었다.

집단에너지 열연계운전 분석을 위한 시뮬레이터 개발 (Development of a simulation program for the analysis of a thermal networking operation in District Heating)

  • 임용훈;박화춘;정모
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.825-832
    • /
    • 2008
  • A simulation program is developed for analysing thermal networking process between the District heating and the CES(Community Energy Supply) systems. The effects of thermal networking on the District heating facilities previously being operated are implemented using mathematical correlations in terms of the fuel consumption and energy load such as heating and electricity. The operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features of the newly developed program in simulation of thermal networking process in district heating is described in terms of the reliability and the easiness for operating it etc.

  • PDF

건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석 (Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method)

  • 박재중;명제민;송두삼
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

BIM기반 공동주택 환경성능 및 에너지 해석 시스템 통합 개발 (BIM-Based Integrated Module for Apartment Environmental Performance and Energy Analysis)

  • 서혜수;이수현;임재상;최철호
    • 한국BIM학회 논문집
    • /
    • 제4권2호
    • /
    • pp.1-9
    • /
    • 2014
  • As interest in green building has increased, construction market has evolved through BIM-based architecture also, BIM-based technologies have been developed simultaneously. Due to this aspect, the need of environmental analysis software utilizing BIM data became essential. This study shows that BIM-based integrated module provides objective analysis to proceed quick decision-making for a proposal. In addition to that, this integrated module creates a model through BIM data to analyze and report residential environment and energy consumption such as, daylight, view, ventilation and privacy in order to practically apply the BIM technology from the schematic design.