• Title/Summary/Keyword: anterior root tear

Search Result 5, Processing Time 0.02 seconds

Arthroscopic Repair of Anterior Root Injury in Lateral Meniscus Using Suture Anchor - Case Report and Technical Note - (Suture anchor를 이용한 외측 반월판 연골 전방 뿌리 파열의 관절경적 치료 -증례 및 술기 보고-)

  • Kim, Do-Young;Yoo, Yon-Sik;Lee, Sang-Soo;Jeong, Un-Seob;Seo, Eun-Min;Park, Seung-Jae
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.41-45
    • /
    • 2011
  • As awareness of root tear of meniscus have been increased, it became necessary to have an intensive repair. Posterior horn tear, especially for a lot of repair methods and the results have been reported recently. The report of the anterior root tear has yet to be found. We recently encountered a patient with an iatrogenic meniscal subluxation caused by past experienced partial menisectomy for discoid meniscus. Thus, we repots the technique and clinical results of arthroscopic repair of subluxated lateral meniscus anterior root tear using suture anchor.

  • PDF

Avulsion Fracture of the Anterior Medial Meniscus Root (내측 반월상연골 전방 기시부 견열 골절)

  • Min, Kyoung-Dae;Cho, Whi-Je;Kim, Kyoung-Bum
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.450-455
    • /
    • 2020
  • Posterior root tear of the medial meniscus are well known. Although very rare, there are reports of anterior root tears of the medial meniscus but no reports on traumatic bony avulsion of the anterior medial meniscus root. This paper reports a case of an isolated bony avulsion of the anterior medial meniscus root, which was successfully repaired arthroscopically.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

Arthroscopic All Inside Repair of Lateral Meniscus Root Tear -Technical note- (외측 반월상 연골 경골 후방 부착부 파열의 관절경적 All-Inside 봉합술 - 수술술기 -)

  • Ahn, Jin-Hwan;Lee, Dong-Hoon;Chang, Moon-Jong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2007
  • Purpose: The authors introduce a new technique of arthroscopic all inside repair using anterolateral and anteromedial portals for lateral meniscus root complete radial tear in patients who underwent concurrent anterior cruciate ligament (ACL) reconstruction. Operative technique: Arthroscope is placed through anteromedial portal and suture hook ($Linvatec^{TM}$, Largo, Florida, USA) is delivered through anterolateral portal. By rotating the suture hook, it penetrates posterior horn of the torn meniscus from femoral to tibial surface for vertical orientation. PDS No. 1 ($Ethicon^{TM}$, Somerville, NJ, USA) is delivered through the suture hook, and then it is withdrawn. Both end of PDS No. 1 are taken out through the anterolateral portal. MAXON 2-0 ($Syneture^{TM}$, Norwalk, Connecticut, USA) is used to penetrates remnant of tibial attachment of the torn meniscus from tibial to femoral surface in a same manner. MAXON 2-0 is changed for PDS No. 1 from tibial to femoral surface by shuttle relay technique. PDS No. 1 is tied using SMC (Samsung Medical Center) knot. Conclusion: All inside repair is a useful technique to achieve anatomical repair and to restore the hoop tension in lateral meniscus root complete radial tear.

  • PDF

Arthroscopic Reduction of Subluxed Medial Meniscus using Suture Anchor for Restoration of Hoop Stress - Technical Note - (버팀테응력 회복을 위한 아탈구된 내측 반월상 연골의 Suture anchor를 이용한 정복술 - 술기 보고 -)

  • Kim, Jaw-Hwa;Lee, Yoon-Seok;Kim, Chul;Han, Seung-Chul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.280-284
    • /
    • 2009
  • Purpose: The authors introduce a new technique of arthroscopic reduction of subluxed medial meniscus using suture anchor for the restoration of hoop stress. Operative Technique: Anterolateral, anteromedial, and medial midpatellar arthroscopic portal are used. Arthroscope was inserted through anterolateral portal. Through the scope, we confirmed subluxation of medial meniscus. Transection of menisci including radial and root tear were excluded. We released the anterior horn of medial meniscus through anteromedial and burred the future insertion site of suture anchor. After inserting suture anchor through medial midpatellar portal, we used 90 degree suture hook and no.2 Nylon to retrieve the suture of inserted anchor. We tied the suture by sliding knot-tying method. Weight bearing was limited for 6 weeks postoperatively. Conclusion: Arthroscopic retightening of medial meniscus is less invasive, conserving and progressed method for subluxed meniscus.

  • PDF