• 제목/요약/키워드: anodic oxidation

검색결과 324건 처리시간 0.028초

산화티타늄피막의 광 전기분해 특성에 대한 연구 (A Study of Photoelectrolysis of Water by Use of Titanium Oxide Films)

  • 박성용;조원일;조병원;이응조;윤경석
    • 한국수소및신에너지학회논문집
    • /
    • 제2권1호
    • /
    • pp.47-56
    • /
    • 1990
  • Pure titanium rods were oxidized by anodic oxidation, furnace oxidation and flame oxidation and used as a electrode in the photodecomposition of water. The maximum photoelectrochemical conversion efficiency(${\eta}$) was found for flame oxidized electrode ($1200^{\circ}C$ for 2 min in air), 0.8 %. Anodically oxidized electrodes have minimum photoelectrochemical conversion efficiencies, 0.3 %. Furnace oxidized electrode ($800^{\circ}C$ for 10min in air) has 0.5% phtoelectrochemical efficiency and shows a band-gap energy of about 2.9eV. The efficiency shows a parallelism with the presence of the metallic interstitial compound $TiO_{O+X}$(X < 0.33) at the metal-semiconductor interface, the thickness of the sub oxide layer and that of the external rutile scale.

  • PDF

RESONANCE FREQUENCY ANALYSIS OF IMPLANTS WITH ANODIZED SURFACE OXIDES

  • Choi Jeong-Won;Heo Seong-Joo;Chang Ik-Tae;Koak Jai-Young;Han Jong-Hyun;Kim Yong-Sik;Lee Seok-Hyung;Yim Soon-Ho
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.294-300
    • /
    • 2004
  • The present experimental study was designed to address two issues. The first was to investigate whether oxidation voltage of titanium implants influenced bone tissue responses after an in vivo implantation. The second aim was to investigate secondary stability change after 1 to 3months period. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of $3-15{\mu}m$. The micro structure revealed pore sizes of $1-3{\mu}m$, the crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. Bone tissue responses were evaluated by resonance frequency measurements that were undertaken 1 to 3months after insertion in the rabbit tibia. It was concluded that no statistical difference of RFA values was found between the groups, RFA gains after Imonth and 3months were calculated.

플라즈마 전해 산화 처리한 AZ91D 마그네슘합금 피막의 미세조직 및 부식 특성 (Microstructure and Corrosion Properties of AZ91D Magnesium Alloy treated by Plasma Electrolytic Oxidation)

  • 장시영;김예림;김양도
    • 한국주조공학회지
    • /
    • 제28권1호
    • /
    • pp.20-24
    • /
    • 2008
  • The characteristics, such as roughness, thickness, microhardness and corrosion resistance, of plasma electrolytic oxide coatings on AZ91D alloy were investigated under the processing condition of various coating times. The coatings on AZ91D alloy consisted of MgO, $MgAl_{2}O_{4}$ and $Mg_{2}SiO_{4}$ oxides. The surface roughness and thickness of coatings became larger with increasing the coating time. The microhardness in cross section of coatings was much higher than not only that in surface but that in the conventional anodic oxide coatings, which increased progressively as the coating time increased. After being immersed in 3.5%NaCl solution and methyl alcohol, the corrosion resistance of AZ91D alloy was markedly improved by plasma electrolytic oxidation coating treatment, and the AZ91D alloy coated for 50min revealed excellent corrosion resistance.

Kinetic Study of the Electrooxidation of Mefenamic Acid and Indomethacin Catalysed on Cobalt Hydroxide Modified Glassy Carbon Electrode

  • Saghatforoush, Lotfali.;Hasanzadeh, Mohammad.;Karim-Nezhad, Ghasem.;Ershad, Sohrab.;Shadjou, Nasrin.;Khalilzadeh, Balal.;Hajjizadeh, Maryam.
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권6호
    • /
    • pp.1341-1348
    • /
    • 2009
  • Electrocatalytic oxidation of two anti-inflammatory drugs (Mefenamic acid and Indomethacin) was investigated on a cobalt hydroxide modified glassy carbon (CHM-GC) electrode in alkaline solution. The process of oxidation and its kinetics were established by using cyclic voltammetry and chronoamperometry techniques as well as steady state polarization measurements. Voltammetric studies indicated that in the presence of under study drugs, the anodic peak current of low-valence cobalt species increased, followed by a decrease in the corresponding cathodic current. This result indicates that the drugs were oxidized via cobalt hydroxide species immobilized on the electrode surface via an E$\acute{C}$ mechanism. A mechanism based on the electrochemical generation of Co (IV) active sites and their subsequent consumption by the drugs in question was also investigated. The constants rate of the catalytic oxidation of the drugs and the electron-transfer coefficients reported.

Substituent Effects and Correlations of Electrochemical Behaviors with Molecular Orbital Calculation of Thioxantone DerivativesⅠ

  • 곽경도;서무룡;하광수;백우현
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권5호
    • /
    • pp.527-530
    • /
    • 1998
  • This paper presents the electrochemistry and molecular orbital (MO) picture of a series of conformationally-restricted thioxantone derivatives. A series of $C_2-substituted$ thioxanthones were examined to probe the electronic influence of the substituent on the electrooxidation and electroreduction sites (i.e., on the electron densities at the 10-and 9-positions), respectively. In the presence of "electrophoric" groups such as C=O and S, characteristic electrochemical reduction and oxidation responses are observed. The electrochemical reaction was diffusion-controlled, because the $I_p/{\upsilon}^{1/2}$ ratio was constant for the anodic and cathodic wave of thioxantone derivatives. These substituent effects are presented in terms of correlations of oxidation (or reduction) potentials with the highest occupied molecular orbital (HOMO), or lowest unoccupied molecular orbital (LUMO) energies, respectively. There is good correlation between energies of the HOMO vs. $E_{pa}^{(+)}$ and energies of the LUMO vs. $E_{pc}^{(-)}$. Frontier Molecular Orbital (FMO) is changed by the functional group of thioxanthones. FMO energy level was offered us the information about the electron transfer direction, and the coefficient of FMO was offered the information about the electron transfer position. Sulfur atom has an important effect on oxidation potential, $E_{pa}^{(+)}$ and the carbonyl carbon has an important effect on reduction potential, $E_{pc}^{(-)}$. Therefore we were appreciated that the contribution of sulfur atom for the $E_{pa}^{(+)}$ and HOMO energies is larger than the contribution of carbonyl group for the $E_{pc}^{(-)}$ and LUMO energies.

정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구 (A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD)

  • 신동훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

A Novel Electrochemical Method for Sensitive Detection of Melamine in Infant Formula and Milk using Ascorbic Acid as Recognition Element

  • Li, Junhua;Kuang, Daizhi;Feng, Yonglan;Zhang, Fuxing;Xu, Zhifeng;Liu, Mengqin
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권8호
    • /
    • pp.2499-2507
    • /
    • 2012
  • A novel and convenient electrochemical method has been developed for sensitive determination of melamine (MEL) using ascorbic acid (AA) as the recognition element. The working electrode employed in this method was modified with the nanocomposite of hydroxyapatite/carbon nanotubes to enhance the current signal of recognition element. The interaction between MEL and AA was investigated by fourier transform infrared spectroscopy and cyclic voltammetry, and the experimental results indicated that hydrogen bonding was formed between MEL and AA. Because of the existing hydrogen bonding and electrostatic interaction, the anodic peak current of AA was decreased obviously while the non-electroactive MEL added in. It illustrated that the MEL acted as an inhibitor to the oxidation of AA and the decreasing signals can be used to detect MEL. Under the optimal conditions, the decrease in anodic peak current of AA was proportional to the MEL concentrations ranging from 10 to 350 nM, with a detection limit of 1.5 nM. Finally this newly-proposed method was successfully employed to detect MEL in infant formula and milk, and good recovery was achieved.

용융탄산염 연료전지의 양극 대체재료의 개발에 관한 연구 (A Study on the Development of Anode Material for Molten Carbonate Fuel Cell)

  • 황응림;김선지;강성군
    • 에너지공학
    • /
    • 제2권3호
    • /
    • pp.293-299
    • /
    • 1993
  • 용융탄산염연료전지(MCFC)용 다공성 Ni 양극에 3~10 wt% Al를 첨가하여 tape casting 법으로 제조된 Ni-Al 양극의 전기화학적성능 및 구조적안정성이 조사되었다. 본 연구에서 제조된 양극의 전기화학적 성능이 $650^{\circ}C$, MCFC 양극분위기(80% H$_2$+20% $CO_2$)를 모사한 half-cell 에서 양분극 특성으로 평가되었는데, 전류밀도 150 ㎃/$\textrm{cm}^2$ 에서의 분극전압은 약 100 ㎷로 실용전지의 양극으로서 가능성을 보였다. Ni-Al 양극의 소결과 creep에 대한 저항성은 Ni 양극에 비해 증가되었는데, 이는 Ni 입자 표면에 형성된 $Al_2$O$_3$의 영향으로 판단되었다.

  • PDF

다공성 실리콘의 제작조건과 열처리에 따른 Photoluminescence 변화 (Change in Photoluminescence of Porous Silicon with Processing Condition and Heat Treatment)

  • 서영제;최두진;박홍이;이덕희
    • 한국세라믹학회지
    • /
    • 제33권10호
    • /
    • pp.1170-1176
    • /
    • 1996
  • Porous silicon was prepared by anodic reaction. The process was controlled by current density and etching time an the thickness change and the room temperature PL was measured. The thickness of porous silicon was increased with etching time and was decreased after critical time. It was the same as increasing current density. It needed only 15 sec to electropolish the surface of porous silicon above current density 70 mA/cm2. We can understand that increasing etching time leads narrow size of Si column by porous silicon formation mechanism. And the sample with narrow Si column revealed PL blue shift. The specimens were heated in the range of 300-1000$^{\circ}C$ in order to see PL changes. The heat treatment was proceeded in H2 atmosphere vacuum system to avoid oxidation. The PL was disappeared above 600$^{\circ}C$. In high temperature some sintered Si columns were observed in SEM photography. There was no difference of -Hx bonds which was suggested as evidence of hydride compounds luminescence between 500$^{\circ}C$ and 600$^{\circ}C$. Thus it is concluded that quantum confinement is major factor of PL of porous silicon.

  • PDF

Real-time Assay of Toxic Lead in In Vivo Living Plant Tissue

  • Ly, SuwYoung;Kim, Nack Joo;Youn, Minsang;Kim, Yongwook;Sung, Yeolmin;Kim, Dohoon;Chung, Tackhyun
    • Toxicological Research
    • /
    • 제29권4호
    • /
    • pp.293-298
    • /
    • 2013
  • A method of detecting lead was developed using square wave anodic stripping voltammetry (SWASV) with DNA-carbon nanotube paste electrode (CNTPE). The results indicated a sensitive oxidation peak current of lead on the DNA-CNTPE. The curves were obtained within a concentration range of 50 $ngL^{-1}-20mgL^{-1}$ with preconcentration time of 100, 200, and 400 sec at the concentration of $mgL^{-1}$, ${\mu}gL^{-1}$, and $ngL^{-1}$, respectively. The observed relative standard deviation was 0.101% (n = 12) in the lead concentration of 30.0 ${\mu}gL^{-1}$ under optimum conditions. The low detection limit (S/N) was pegged at 8 $ngL^{-1}$ ($2.6{\times}10^{-8}M$). Results showed that the developed method can be used in real-time assay in vivo without requiring any pretreatment and pharmaceutical samples, and food samples, as well as other materials requiring water source contamination analyses.