• 제목/요약/키워드: anodic current

검색결과 432건 처리시간 0.021초

A Review on Dielectric Breakdown of Anodic Oxide Films on Aluminum Alloys

  • Hien Van Pham;Cheolnam Yang;Sungmo Moon
    • 한국표면공학회지
    • /
    • 제57권4호
    • /
    • pp.254-264
    • /
    • 2024
  • This paper reviews the dielectric breakdown resistance and behavior of anodic oxide films in air environment. It begins with a description of the dielectric breakdown mechanisms of dielectric materials. The paper then introduces different types of dielectric materials and compares them in terms of dielectric strength, thermal conductivity, mechanical strength and cost. Next, the paper summarizes various fabrication methods for dielectric aluminum oxide layers, discussing the advantages and disadvantages of each method. Finally, it provides an overview of current studies on the dielectric breakdown properties of anodic aluminum oxide films formed on different aluminum alloys in various electrolytes.

Detection of Trace Copper Metal at Carbon Nanotube Based Electrodes Using Squarewave Anodic Stripping Voltammetry

  • Choi, Changkun;Jeong, Youngsam;Kwon, Yongchai
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.801-809
    • /
    • 2013
  • We investigate sensitivity and limit of detection (LOD) of trace copper (Cu) metal using pristine carbon nanotube (CNT) and acidified CNT (ACNT) electrodes. Squarewave based anodic stripping voltammetry (SWASV) is used to determine the stripped Cu concentration. Prior to performing the SWASV measurements, its optimal conditions are determined and with that, effects of potential scan rate and $Cu^{2+}$ concentration on stripping current are evaluated. The measurements indicate that (1) ACNT electrode shows better results than CNT electrode and (2) stripping is controlled by surface reaction. In the given $Cu^{2+}$ concentration range of 25-150 ppb, peak stripping current has linearity with $Cu^{2+}$ concentration. Quantitatively, sensitivity and LOD of Cu in ACNT electrode are 9.36 ${\mu}A\;{\mu}M^{-1}$ and 3 ppb, while their values are 3.99 ${\mu}A\;{\mu}M^{-1}$ and 3 ppb with CNT electrode. We evaluate the effect of three different water solutions (deionized water, tap water and river water) on stripping current and the confirm types of water don't affect the sensitivity of Cu. It turns out by optical inspection and cyclic voltammetry that superiority of ACNT electrode to CNT electrode is attributed to exfoliation of CNT bundles and improved interfacial adhesion occurring during oxidation of CNTs.

Monitoring Cathodic Shielding and Corrosion under Disbonded Coatings

  • Varela, F.;Tan, M. YJ;Hinton, B.;Forsyth, M.
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.109-114
    • /
    • 2017
  • Monitoring of corrosion is in most cases based on simulation of environmental conditions on a large and complex structure such as a buried pipeline using a small probe, and the measurement of thermodynamics and kinetics of corrosion processes occurring on the probe surface. This paper presents a hybrid corrosion monitoring probe designed for simulating deteriorating conditions wrought by disbonded coatings and for measuring current densities and distribution of such densities on a simulated pipeline surface. The concept of the probe was experimentally evaluated using immersion tests under cathodic protection (CP) in high resistivity aqueous solution. Underneath the disbonded area, anodic currents and cathodic currents were carefully measured. Anodic current densities were used to calculate metal loss according to Faraday's law. Calculated corrosion patterns were compared with corrosion damage observed at the surface of the probe after a series of stringent tests. The capability of the probe to measure anodic current densities under CP, without requiring interruption, was demonstrated in high resistivity aqueous solution. The pattern of calculated metal loss correlated well with corrosion products distribution observed at the array surface. Working principles of the probe are explained in terms of electrochemistry.

Numerical model for local corrosion of steel reinforcement in reinforced concrete structure

  • Chen, Xuandong;Zhang, Qing;Chen, Ping;Liang, Qiuqun
    • Computers and Concrete
    • /
    • 제27권4호
    • /
    • pp.385-393
    • /
    • 2021
  • Reinforcement corrosion is the main cause of the durability failure of reinforced concrete (RC) structure. In this paper, a three-dimensional (3D) numerical model of macro-cell corrosion is established to reveal the corrosion mechanisms of steel reinforcement in RC structure. Modified Direct Iteration Method (MDIM) is employed to solve the system of partial differential equations for reinforcement corrosion. Through the sensitivity analysis of electrochemical parameters, it is found that the average corrosion current density is more sensitive to the change of cathodic Tafel slope and anodic equilibrium potential, compared with the other electrochemical parameters. Furthermore, both the anode-to-cathode (A/C) ratio and the anodic length have significant influences on the average corrosion current density, especially when A/C ratio is less than 0.5 and anodic length is less than 35 mm. More importantly, it is demonstrated that the corrosion rate of semi-circumferential corrosion is much larger than that of circumferential corrosion for the same A/C ratio value. The simulation results can give a unique insight into understanding the detailed electrochemical corrosion processes of steel reinforcement in RC structure for application in service life prediction of RC structures in actual civil engineer.

Affecting of Corrosion Potential and Current Density on Variation Polarization Curves with Polyvinylchloride (I)

  • Choi, Chil-Nam;Yang, Hyo-Kyung;Jung, Oh-Jin
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제2권2호
    • /
    • pp.91-98
    • /
    • 1998
  • In this study, we carried out the experiments for measuring the variations of corrosion potential and current density for polarization curves with polyvinylchloride. The results exhibited especially the influence affecting the corrosion potential and various conditions (temperature, day, pH, bacteria, and added salt). The second anodic current density peak and the minimum passive current density are designated $I_P/I_0,$ respectively. The value of $I_P/I_O$ is used as a measurement for the extent of degradation of the polyvinylchloride. The potentiodpnamics parameters of the corrosion were obtained using Tafel equation.

  • PDF

Cyclitol 유도체 합성에 관한 연구 (제3보)-myo-Inositol의 전해 산화- (Synthesis of Cyclitol Derivatives (Ⅲ). Electrolytic Oxidation of myo-Inositol)

  • 손주환;남종우;김유옥
    • 대한화학회지
    • /
    • 제15권3호
    • /
    • pp.127-132
    • /
    • 1971
  • To obtain the various kinds of inosose stereomers, the process of electrochemical oxidation is more effective than chemical oxidation of myo-inositol. So that myo-inositol aqueous solution was electrolyzed by platinum and lead peroxide anode to confirming the occurrence of electrochemical oxidation. The result is that myo-inosose-2 is producing with high yield comparatively by electrolytic oxidation of myo-inositol. Also we studied about the relation between the electrolytic current efficiency and electrolytic temperature and anodic current density. The current efficiency is rising with lowering of electrolytic temperature identically in both anode such as platinum and lead peroxide and also rising with increasing of anodic current density in platinum anode, but inversely in lead peroxide.

  • PDF

Al6061 합금의 정전압 아노다이징 피막의 형성거동 및 버닝에 대한 연구 (A Study on the Growth and Burning of Anodic Oxide Films on Al6061 Alloy During Anodizing at Constant Voltages)

  • 문상혁;문성모;송풍근
    • 한국표면공학회지
    • /
    • 제53권1호
    • /
    • pp.15-21
    • /
    • 2020
  • In this study, growth and burning behavior of 6061 aluminum alloy was studied under constant anodic voltages at various temperatures and magnetic stirring rates in 20% sulfuric acid solution by analysing I-t curves, measuring thickness and hardness of aluminum anodic oxide (AAO) films, observations of surface and cross-sectional images of AAO films. AAO films were grown continuously at lower voltages than 18.5V but burning occurred when a voltage more than 19V was applied in 20% H2SO4 solution at 20±0.5℃ and 200 rpm of magnetic stirring. The burning was always related with an extremely large increase of anodic current density with anodizing time, suggesting that high heat generation during anodizing causes deteriorations of AAO films by chemical reaction with acidic solutions. The burning resulted in decreases of film thickness and hardness, surface color brightened and formation of porous defects in the AAO films. The burning voltage was found to decrease with increasing solution temperature and decreasing magnetic stirring rate. The decreased burning voltages seem to be closely related with increased chemical reactions between AAO films and hydrogen ions.

황산 용액에서 Al6061 합금의 아노다이징 피막 형성거동 (Formation Behavior of Anodic Oxide Films on Al 6061 Alloy in Sulfuric Acid Solution)

  • 문성모;정기훈;임수근
    • 한국표면공학회지
    • /
    • 제51권6호
    • /
    • pp.393-399
    • /
    • 2018
  • Formation behavior of aluminum anodic oxide (AAO) films on Al6061 alloy was studied in view of thickness, morphology and defects in the anodic films in 20 vol.% sulfuric acid solution at a constant current density of $40mA/cm^2$, using voltage-time curve, observation of anodized specimen colors and surface and cross-sectional morphologies of anodic films with anodization time. With increasing anodizing time, voltage for film formation increased exponentially after about 12 min and its increasing rate decreased after 25 min, followed by a rapid decrease of the voltage after about 28 min. Surface color of anodized specimen became darker with increasing anodizing time up to about 20 min, while it appeared to be brighter with increasing anodizing time after 20 min. The darkened and brightened surfaces with anodizing time are attributed to an increase in thickness of porous anodic oxide film and a chemical damage of the films due to heat generated by increased resistance of the film, respectively. Cross-sectional observation of AAO films revealed the formation of defects of crack shape at the metal/oxide interface after 15 min which prevents the growth of AAO films. Width and length of the crack-like defect increased with anodizing time up to 25 min of anodizing, and finally the outer part of AAO films was partly dissolved or detached after 30 min of anodizing, resulting in non-uniform surface structures of the AAO films.

Corrosion Characteristics of Amorphous Alloy Ribbon ($Fe_{70}Cr_5Si_{10}B_{15}$ and $Co_{70}Cr_5Si_{10}B_{15}$) in Hydrochloric Acid Aqueous Solution

  • Choi, Chil-Nam;Hyo, Kyung-Yang;Yang, Myung-Sun
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2001년도 정기총회 및 봄 학술발표회 초록집
    • /
    • pp.236-237
    • /
    • 2001
  • In this study, experiments were carried out to measure the variations in the corrosion potential and current density of polarization curves with amorphous $Fe_{70}Cr_5Si_{10}B_{15}$ and $Co_{70}Cr_5Si_{10}B_{15}$ alloy ribbon. The results were particularly examined to identify the influences of corrosion potential including various conditions such as hydrochloric acid, temperature, salt, pH, and oxygen. The optimum conditions were established with variations including temperature, salt, pH, oxygen, corrosion rate, and resistance of corrosion potential. The mass tranfer coefficient(${\alpha}$) value was determined with the Tafel's slope for the anodic dissolution based on the polarization effect with optimum conditions. The second anodic current density peak and maximum passive current density were designated as the critical corrosion sensitivity($I_{r}/I_{f}$).

  • PDF

Development of Ultral Clean Machining Technology with Electrolytic Polishing Process

  • Lee, Eun-Sang;Park, Jeong--Woo;Moon, Young-Hun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권1호
    • /
    • pp.18-25
    • /
    • 2001
  • Electrolytic polishing is the anodic dissolution process in the transpassive state. It removes non-metallic inclusion and improves mechanical and corrosion resistance of stainless steel. If there is a Bailby layer, it will be removed and the true structure of the surface will be restored. Electrolytic polishing is normally used to remove a very thin layer of material from the surface of metal object. A new electrolyte composed of phosphoric, sulfuric and distilled water has been developed in this study. Two current density, high & low current density regions, have been applied in this study. In this study, In the region of high current density, there is no plateau region but excellent electrolytic polishing effect can be accomplished in short machining time because material removel process and leveling process occur simultaneously. In the low current density region, there can be found plateau region. The material removal process and leveling process occur successively. The aim of this work is to determine electrolytic polishing for stainless steel in terms of high & low current density and workpiece surface roughness.

  • PDF