• Title/Summary/Keyword: anisotropic index

Search Result 47, Processing Time 0.022 seconds

Study on the Fabrication and Characterization of Compact ECR Plasma System (Compact ECR plasma장치의 제작 및 특성 연구)

  • 윤민기;박원일;남기석;이기방
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.4
    • /
    • pp.84-91
    • /
    • 1994
  • A compact electron cyclotron resonance(ECR) plasma system composed of a microwave generator and a magnet coil was fabricated. A Langmuir single probe was used to investigate the plasma characteristics of the system through I-V measurements. The performance of the compact ECR plasma system was tested for the case of silicon etching reaction with $CF_{4}/O_{2}$(30%) mixed gas. Electron density and etch rate increased to maximum values and then decreased with increasing argon gas pressure, but electron temperature changed in the opposite way. The electron density and the electron temperature of argon gas plasma were 0.85${\times}~5.5{\times}10^{10}cm^{-3}$ and 4.5~6.0 eV, respectively, in the pressure range from $3{\times}10^{4}$ to 0.05Torr. The etch rate reached a maximum value at the position of 2.5cm from the bottom of plasma cavity. Etch rate uniformity was $\pm$6% across 6cm wafer. Anisotropic index was 0.75 at 1.5${\times}10^{-4}$Torr.

  • PDF

Circular Polarizers for Reflective LCDs

  • Yoshimi, Hiroyuki;Yano, Shuji;Fujimura, Yasuo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.905-909
    • /
    • 2002
  • Characteristics of reflective LCDs, which have gained a lot of notice in recent years, rely largely on optical design of circular polarizers and the quarter-wave plates, as a component. Important design includes wavelength dispersion, viewing angle, uniformity of display and matching of refractive index. Our work has contributed to improving performance of reflective LCDs by enhancing the characteristics of polymer film using stretching and optical lamination technologies. To design that offers higher contrast and wider viewing angle, we have discovered that it is necessary to control viewing angle variation of the polarizing axis in order to compensate for the viewing angle of the polarizing film as well as the optical anisotropic properties of liquid crystal. Applying this technology to circular polarizers used for reflective LCDs enables design of wide viewing angle circular polarizers. In order to realize higher contrast for reflective LCDs, it is also necessary to design other optical materials including polarizing films. For design of hybrid optical film, it is particularly necessary to reduce surface reflection and interface reflection. This paper also reports our findings concerning this topic.

  • PDF

Studies on the Crystal Structure of Magnesite (마그네사이트 (MgCO$_3$)의 결정구조에 관한 연구)

  • 오기동
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.3
    • /
    • pp.8-12
    • /
    • 1975
  • The crystal structure of synthetic magnesite has been studied by X-ray method. Magnesite is trigonal R3c, with a=4.637$\AA$, c=15.023$\AA$ and Z=6. Intensity data were collected with a Rigaku automated four-circle diffractometer and Mo-K$\alpha$ radiation. The structure was refined by the full-matrix least squares method using anisotropic thermal parameters. The final R index for 234 reflections is 0.037. The C-O and Mg-O bond lengths were 1.283 and 2.105$\AA$, respectively. The interatomic angles of three kinds of O-Mg-O were 88.25, 91.75 and 180.00$^{\circ}$, respectively. It is clarified that the distortion of the Mg-O6 octahedron in magnesite is smaller than that of Ca-O6 in calcite.

  • PDF

Strength Anisotropy through Artificial Weak Plane of Mudstone (인공연약면을 따른 이암의 강도이방성에 관한 연구)

  • Lee, Young-Huy;Jeong, Ghang-Bok
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.111-120
    • /
    • 2008
  • The characteristic of induced anisotropy is investigated in this study for the Pohang mudstone involving the cut plane discontinuity. The uniaxial and triaxial compression tests are performed for anisotropic rocks with artificial joint to look into anisotropic strength characteristics. Both the uniaxial compressive strength and triaxial compressive strength show the lowest value at the angle of cut plane, ${\beta}=30^{\circ}$ and the shoulder type of anisotropy is obtained. Anisotropy ratio (Rc) in uniaxial compression measures 9.0, whereas Rc=1.29-1.98 in triaxial compression is appeared. A series of analyses are made with the test results to derive the suitable parameter values when it is applied to the Ramamurthy (1985) failure criterion. The result of uniaxial compression test is analyzed by introducing the n-index into Ramamurthy failure criterion. The result shows that, n=l is suitable for ${\beta}=0^{\circ}{\sim}30^{\circ}$ and n=3 is suitable for ${\beta}=30^{\circ}{\sim}90^{\circ}$. To analyze the result of triaxial compression test by Ramamurthy failure criterion, anisotropy ratio in uniaxial compression test is added to Ramamurthy's equation and material constants are estimated by modified Ramamurthy's equation. When these values are applied back to Ramamurthy failure criterion, the predicted values are well fitted to the test results. And strength anisotropy for failure criteria of Jaeger (1960), McLamore & Gray (1967) and Hoek & Brown (1980) are also investigated.

The Anisotropic Mechanical Characteristics of the Metamorphic Rocks Distributed in the Samkwang-Mine Area, Cheongyang, Chungnam (충남 청양군 운곡면 일원에 분포하는 편마암의 강도이방성 특성 - 점재하강도지수와 일축압축강도의 관계를 중심으로 -)

  • 배대석;송무영;김경수
    • The Journal of Engineering Geology
    • /
    • v.1 no.1
    • /
    • pp.54-67
    • /
    • 1991
  • In geological media with anisotropic properties, the strength anisotropy in intact rock is the most important issue in engineering aspects. Point-ioad(P/L) strength test designed to estimate the uniaxial compressive strength(${\sigma}_c$) can be used to evaluate the anisotropic strength characteristics of rocks. The relationship between ${\sigma}_c$ and P/L strength indices(I$_s$), obtained from the banded gneisses distributed in the Cheongyang area, varies depend mainly on the dip angle($\beta$) of foliation. The axial P/L strength indicies(I$_{sa}$) decreases with the increment of $\beta$, whereas diametral P/L strength indices(I$_{sa}$) increase with it. However, the ${\sigma}_c$ decreases with the increments of $\beta$ below about 40$^{\circ}$, but it increases with the increments of $\beta$ over about 40$^{\circ}$ in general. The correlation between ${\sigma}_c$ and I$_s$ suggests that ${\sigma}_c$ is related to the Isa withing low angle($\beta$<40$^{\circ}$) and the I$_{sd}$ within high angle ($\beta$>40$^{\circ}$), respectively. The ratios of I$_s$ to ${\sigma}_c$ are obtained as 11 to 14 in the the gneisses in the study area. The ratio of 24, which is generally adopted value, cannot always be truthworth to the gneisses in the study area. The ratio for the dykes, however, show a good correlation as 21 to 24.5 and, the value of 24 can be used for a homogeneous and isotropic materials such as dykes.

  • PDF

Observation Test of Field Surface Reflectance Using Vertical Rotating Goniometer on Tarp Surface and Grass (수직 축 회전형 측각기 제작 및 야외 지표면 반사도 관측 시험: 타프와 잔디에서)

  • Moon, Hyun-Dong;Jo, Euni;Kim, Hyunki;Cho, Yuna;Kim, Bo-Kyeong;Ahn, Ho-Yong;Ryu, Jae-Hyun;Cho, Jaeil
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1207-1217
    • /
    • 2022
  • Vegetation indices using the reflectance of selected wavelength, associating with the monitoring purpose such as identifying the progress of crop growth, on the vegetation canopy surface is widely used in the digital agriculture technology. However, the surface reflectance anisotropy can distort the true value of vegetation index related to the condition of surface, even though the surface property be unchanged. That causes difficulty to observe accurately crop growth on the monitoring system. In this study, a simple type goniometer was designed to measure the reflectance from the anisotropic surface according to various zeniths and azimuths of sun and viewing sensor in the field. On the tarp like as Lambertian surface, the reflectance of Blue, Green, Red, Near-Infrared band was similar to the tarps' reflectance properties. However, the reflectance was slightly overestimated in the cloudy day. The relative difference values of vegetation indices on grass were overestimated for the forward viewing and underestimated for the backward viewing. In addition, enhanced vegetation index (EVI) showed less sensitive according to the positions of sun and sensor viewing. Field observation with a goniometer will be helpful to understand the anisotropy characteristics on the vegetation surface.

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).

High-Resolution Sentinel-2 Imagery Correction Using BRDF Ensemble Model (BRDF 앙상블 모델을 이용한 고해상도 Sentinel-2 영상 보정)

  • Hyun-Dong Moon;Bo-Kyeong Kim;Kyeong-Min Kim;Subin Choi;Euni Jo;Hoyong Ahn;Jae-Hyun Ryu;Sung-Won Choi;Jaeil Cho
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1427-1435
    • /
    • 2023
  • Vegetation indices based on selected wavelength reflectance measurements are used to represent crop growth and physiological conditions. However, the anisotropic properties of the crop canopy surface can govern spectral reflectance and vegetation indices. In this study, we applied an ensemble of bidirectional reflectance distribution function (BRDF) models to high-resolution Sentinel-2 satellite imagery and compared the differences between correction results before and after reflectance. In the red and near-infrared (NIR) band reflectance images, BRDF-corrected outlier values appeared in certain urban and paddy fields of farmland areas and forest shadow areas. These effects were equally observed when calculating the normalized difference vegetation index (NDVI) and 2-band enhanced vegetation index (EVI2). Furthermore, the outlier values in corrected NIR band were shown in pixels shadowed by mountain terrain. These results are expected to contribute to the development and improvement of BRDF models in high-resolution satellite images.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

Analysis of Coplaner $LiNBO_3$ Waveguide Structures Applicable Electrooptic Modulator with FDTD method

  • Lee, Byung-Je;Byun, Joon-Ho;Kim, Nam-Young;Kim, Jong-Heon;Lee, Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1211-1217
    • /
    • 2000
  • The three-dimensional finite-difference time-domain (FDTD) method and the two-dimensional quasi-static formulation have been used to calculate the characteristic impedance and the microwave effective index of coplanar waveguide structures on Lithium Niobate ($LiNBO_3$) single crystal substrates with a yttria-stabilized zirconia (YSZ) or $SiO_2$ buffer layer. The results shown can be a good source to predict the modulator characteristics. The effects of the thin buffer layer and anisotropy of the $LiNBO_3$ crystal (x-cut and z-cut) are discussed. The comparison between the FDTD and quasi-static results shows good agreement. In this paper, the efficient modeling technique of the FDTD method for the coplanar waveguide (CPW) structures based on an anisotropic substrate with a thin buffer layer is developed.

  • PDF