• Title/Summary/Keyword: angular measurement

검색결과 343건 처리시간 0.029초

Monitoring of waterjet cutting free surface using laser sensor (레이저 센서를 이용한 워터젯 절삭 자유면 모니터링)

  • Oh, Tae-Min;Hong, Chang-Ho;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제15권5호
    • /
    • pp.469-481
    • /
    • 2013
  • The monitoring of a free surface generated by waterjet cutting technology is very important for an efficient construction process. In this study, experiments using a laser sensor were performed to provide a data processing method and to determine optimized parameters. The experimental parameters here are the angular resolution, measurement distance, and free surface cutting shape. The results show that the monitoring resolution increases with a decrease in the angular resolution and the horizontal measurement distance and with an increase in the cutting (free surface) width. This laser monitoring method can be applied during the measurement of free surface shapes and depths in situ.

Measurement of Angular Velocity of Forearm Pronation/Supination Movement for the Quantification of the Bradykinesia in Idiopathic Parkinson's Disease Patients (특발성 파킨슨병 환자의 완서증 정량화를 위한 전환 내회전/외회전 운동의 각속도 측정)

  • Kim, Ji-Won;Lee, Joseph;Shin, Jin-Young;Lee, Jae-Ho;Kwon, Yu-Ri;Kwon, Do-Young;Park, Kun-Woo;Eom, Gwang-Moon
    • Journal of Biomedical Engineering Research
    • /
    • 제30권2호
    • /
    • pp.142-146
    • /
    • 2009
  • The purpose of this study is to investigate the angular velocity of forearm pronation/supination movement in Parkinson's disease patients, as a quantitative measure of the bradykinesia. Thirteen Parkinson's disease patients ($64{\pm}11.0$ yrs, male:6, female:7) participated in the experiments. The subjects' both right and left forearms were scored by a rater according to rapid alternating movement of hands category in the UPDRS (unified Parkinson's disease rating scale) and the angular velocity of forearm pronation/supination was measured at the same time. As analysis parameters, RMS (root mean square) angular velocity and RMS angle were used. The parameters showed negative correlation with the clinical score (RMS angular velocity: r= - 0.914, RMS angle: r= -0.749). The RMS angular velocity of all clinical scales were significantly different one another except for the non significant difference between those of scale 3 and 4. RMS angle of scale 0 was significantly different from those of scale 2, 3, 4 and that of scale 1 was significantly different from those of scale 3 and 4. This suggests that RMS angular velocity can be used for a quantitative measure of bradykinesia in motor examination.

Sensorless Vector Control for Induction Motor with Rotor Flux Observer (회전자 자속 관측기를 사용한 유도전동기의 센서리스 벡터제어)

  • Kim, Jun-Hyung;Ahn, Sung-Chan;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.591-593
    • /
    • 1996
  • In order to implement the direct vector control type sensorless vector control, the rotor flux and the angular speed of the rotor can only be estimated through the measurement of the stationary voltage and current states. To estimate the rotor flux, the use of the rotor flux observer(RFO) has been proposed. It is known that the RFO is relatively insensitive to parameter variations. Using the rotor flux value obtained from the RFO, the rotor flux vector can be estimated. The angular speed of the rotor is estimated by the difference between the synchronous angular speed and the slip angular speed, both of which are derived from the rotor flux vector. However unwanted high order frequency waves become incorporated into the synchronous angular speed during calculations. Thus we propose the use of digital filters that will eliminate these high frequency waves. We have demonstrated through computer simulations that the use of filters results in stable system activity over a wide speed range and good response to load variations.

  • PDF

Characterization of the 2.5 MeV ELV electron accelerator electron source angular distribution using 3-D dose measurement and Monte Carlo simulations

  • Chang M. Kang;Seung-Tae Jung;Seong-Hwan Pyo;Youjung Seo;Won-Gu Kang;Jin-Kyu Kim;Young-Chang Nho;Jong-Seok Park;Jae-Hak Choi
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4678-4684
    • /
    • 2023
  • Using the Monte Carlo method, the impact of the angular distribution of the electron source on the dose distribution for the 2.5 MeV ELV electron accelerator was explored. The experiment measured the 3-D dose distribution in the irradiation chamber for electron energies of 1.0 MeV and 2.5 MeV. The simulation used the MCNP6.2 code to evaluate three angular distribution models of the source: a mono-directional beam, a cone shape, and a triangular shape. Of the three models, the triangular shape with angles θ = 30°, φ = 0° best represents the angle of the scan hood through which the electron beam exits. The MCNP6.2 simulation results demonstrated that the triangular model is the most accurate representation of the angular distribution of the electron source for the 2.5 MeV ELV electron accelerator.

A Study on the Object Angle Inference in a Sonar Sensor Array System (초음파센서 배열 시스템에서 물체의 각도 추론에 관한 연구)

  • 나승유;박민상
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.271-274
    • /
    • 1998
  • Ultrasonic sensors are becoming indispensable components in every sector of automation equipments due to many advantages. But the main purposes of the noncontact sensing device are rather narrowly confined within object detection and distance measurement. To widen the realm of the applications to object recognition, ultrasonic sensors need to improve the recognition resolution to a certain amount. To resolve the problem of spatial resolution restriction, an increased number of the sensors in the forms of a linear array or 2-dimensional array of the sensor has been used. Also better resolution has been obtained by shifting the array in several steps using mechanical actuators. For an object recognition using ultrasonic sensors, measurements of distance, shift, oblique angle in certain ranges should be obtained. But a little attention has been paid to the measurement of angles. In this paper we propose a practical method for an object angular value detection in addition to distance measurement in ultrasonic sensor array system with little additional hardware burden. Using the established measurement look-up table for the variations of distance, shift, angle and transmitter voltages for each sensor characteristics, a set of different return echo signals for adjacent receivers are processed to provide enhanced angular value reading for an object.

  • PDF

Measurement of 5 DOF Motion Errors in the Ultra Precision Feed Tables for Error Compensation (오차보정을 위한 초정밀 테이블의 5 자유도 운동오차 측정)

  • 오윤진;박천홍;이득우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.672-676
    • /
    • 2004
  • In this paper, measuring system of 5 DOF motion errors are proposed using two capacitive type sensor, a straight edge and a laser interfoerometer. Yawing error and pitching error are measured using the laser interferometer, and rolling error is measured by the reversal method using a capacitive type sensor. Linear motion errors of horizontal and vertical direction are measured using the sequential two point method. In this case, influence of angular motion errors is compensated using the previously measured angular motion errors. In the horizontal direction, measuring accuracy is within 0.05 $\mu$m and 0.27 arcsec, and in the vertical direction, it is within 0.15 $\mu$m and 0.5 arcsec. From these results, it is confirmed that the proposed measureing system is very effective to the measurement of 5 DOF motion errors in the ultra precision feed tables.

  • PDF

A Triple Nested PID Controller based on Sensor Fusion for Quadrotor Attitude Stabilization (쿼드로터 자세 안정화를 위한 센서융합 기반 3중 중첩 PID 제어기)

  • Cho, Youngwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제67권7호
    • /
    • pp.871-877
    • /
    • 2018
  • In this paper, we propose a triple nested PID control scheme for stable hovering of a quadrotor and propose a complementary filter based sensor fusion technique to improve the performance of attitude, altitude and velocity measurement. The triple nested controller has a structure in which a double nested attitude controller that has the angular velocity PD controller in inner loop and the angular PI controller in outer loop, is nested in a velocity control loop to enable stable hovering even in the case of disturbance. We also propose a sensor fusion technique by applying a complementary filter in order to reduce the noise and drift error included in the acceleration and gyro sensor and to measure the velocity by fusing image, gyro, and acceleration sensor. In order to verity the performance, we applied the proposed control and measurement scheme to hovering control of quadrotor.

Isokinetic Evaluation of the Trunk Flexors and Extensors for the White Collar Workers in Adult Males (사무직근로자의 요추부 굴곡근 및 신전근의 등속성 근력평가 서울시 일부지역의 21세 $\sim$ 49세 남자직장인을 중심으로)

  • Oh, Seung-Kil;Choi, Byung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • 제7권1호
    • /
    • pp.377-396
    • /
    • 2000
  • After warming-up exercise for 20 minutes, Isokinetic measurement of trunk strength for flexor and extensor was done by using Cybex 6000 TEF Unit on 91 healthy male white workers from 22years old to 49 years old, and compared each other. 20 repetitions of trunk extension-flexion were done at $120^{\circ}$/sec angular velocity. After resting for 1 minutes, Four repetitions at two different angular velocities($60^{\circ}$/sec, $120^{\circ}$/sec) were done with 30 seconds of resting interval between each angular velocity. The purpose of this study is to obtain the isokinetic normative strength values for trunk extensors and flexors, and is to know the correlation between age, height, weight of subjects and data from isokinetic trunk strength measurement, and is to provide a guideline for exercise program of male white collar workers The collected data were analyzed by ANOVA, Duncan's Multiple Range Test, and Pearson correlation coefficiency in PC-SAS program. The results obtained were as follow; 1. There is significant positive-correlation with the statistic value between weight and peak torque of trunk muscles at two different angular velocities($60^{\circ}$/sec, $120^{\circ}$/sec)(p<01), between height and peak torque of trunk muscles at two different angular velocities($60^{\circ}$/sec, $120^{\circ}$/sec) except peak torque of trunk flexor at $60^{\circ}$/sec(p<01). 2. There is nagitive-correlation between age and peak torque of trunk muscles at two different angular velocities($60^{\circ}$/sec, $120^{\circ}$/sec), there is significant differences with statistic value between age and peak torque of trunk extensor at $120^{\circ}$/sec(p<.01). 3. Mean peak torque and mean peak torque % by body weight of trunk extensor is 1.1 times higher values than trunk flexor at $60^{\circ}$/sec. 4. There is the increase in peak torque angle of trunk flexor with increasing of age, and the decrease in peak torque angle of trunk flexor with increasing of age at two different angular velocities($60^{\circ}$/sec, $120^{\circ}$/sec). there is significant differences with statistic value in peak torque angle of trunk flexor at $120^{\circ}$/sec(p<.01). 5. There is significant decrease in endurance ratio of trunk extensor with increasing of age at $120^{\circ}$/sec(p<.01). In conclusion, peak torque of trunk extensor is 1.1 times higher values than trunk flexor in healthy male white collar workers.

  • PDF

A Study on the Development of Gear Transmission Error Measurement System and Verification (기어 전달오차 계측 시스템 개발 및 검증에 관한 연구)

  • Moon, Seok-Pyo;Lee, Ju-Yeon;Moon, Sang-Gon;Kim, Su-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제20권12호
    • /
    • pp.136-144
    • /
    • 2021
  • The purpose of this study was to develop and verify a precision transmission error measurement system for a gear pair. The transmission error measurement system of the gear pair was developed as a measurement unit, signal processing unit, and signal analysis unit. The angular displacement for calculating the transmission error of the gear pair was measured using an encoder. The signal amplification, interpolation, and transmission error calculation of the measured angular displacement were conducted using a field-programmable gate array (FPGA) and a real-time processor. A high-pass filter (HPF) was applied to the calculated transmission error from the real-time processor. The transmission error measurement test was conducted using a gearbox, including the master gear pair. The same test was repeated three times in the clockwise and counterclockwise directions, respectively, according to the load conditions (0 - 200 N·m). The results of the gear transmission error tests showed similar tendencies, thereby confirming the stability of the system. The measured transmission error was verified by comparing it with the transmission error analyzed using commercial software. The verification showed a slight difference in the transmission error between the methods. In a future study, the measurement and analysis method of the developed precision transmission error measurement system in this study may possibly be used for gear design.

Measurement and Comparison of Finger Tapping Movement in Patients with Idiopathic Parkinson's Disease and Normal Subjects using Gyrosensor (자이로센서를 이용한 특발성 파킨슨병 환자와 정상인의 손가락 벌렸다 오므리기 동작의 측정과 비교)

  • Kim, Ji-Won;Kwon, Yu-Ri;Lee, Jae-Ho;Eom, Gwang-Moon;Kwon, Do-Young;Koh, Seong-Beom;Park, Byung-Kyu;Hong, Jung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • 제31권3호
    • /
    • pp.240-244
    • /
    • 2010
  • The purpose of this study is to compare finger tapping (FT) movement of patients with Parkinson's disease (PD) with normal subjects. A gyrosensor system was used for the measurement of FT movement, because it provides angular velocity free from the gravitational artifact and it can be used during clinical FT test listed in unified PD rating scale (UPDRS). Forty PD patients (age: 65.7 ${\pm}$ 11.1 yrs, H&Y stage:2.3 ${\pm}$ 0.5), 14 age-matched elderly subjects (65${\pm}$3.9 yrs) and 17 healthy young subjects (24${\pm}$2.1yrs) participated in this study. Angular velocity of finger tapping movement was measured in both right and left index finger. As quantitative measures, root-mean-squared (RMS) angular velocity, RMS angle, peak power and total power were used. ANOVA showed that all measures were significantly different among three groups (p<0.001) in all quantitative measures. Post-hoc test revealed that all quantitative measures except peak power in patients with PD were significantly smaller than in both healthy elderly and young subjects (p<0.01). This suggests that the measures developed in this study can distinguish patients with PD from normal subjects.