• 제목/요약/키워드: angles

검색결과 6,389건 처리시간 0.036초

겉보기 응력 개념에 기반한 공구각에 따른 비절삭저항 변화 분석 (Analysis on Specific Cutting Resistance Variation by Tool Angles Based on a Concept of Representative Stres)

  • 전은채;최환진;이규민;이윤희;제태진;김정환;최두선
    • 한국기계가공학회지
    • /
    • 제13권2호
    • /
    • pp.64-72
    • /
    • 2014
  • In the past, prism patterns have been linear triangular shapeswith a $90^{\circ}$ angle; however, new micro prism patterns having acute angles or obtuse angles have recently been the subject of demandin the display, lighting and photovoltaic industries. Micro-cutting experiments for micro-prism patterns having $60^{\circ}$, $90^{\circ}$, and $120^{\circ}$ angles on an electroplated Ni mold were performed and it was found in this study that the specific cutting resistance increased with a decrease in the tool angles (prism pattern angles). The cause of this variation had been thought to be the increase of the ploughing force due to tip rounding and the friction force due to the edge effect. However, the depth of the cut was large enough that it was possible to neglect these effects. Therefore, this study introduced the concept of representative stress of indentation. The measured stress was varied according to the indentation depth eventhoughthetestedspecimenswereidentical ; the varied stress was termed the representative stress. According to indentation theory, the strain that the Ni mold experienced increased with a decrease in the tool angle. Based on the stress-strain relationship, higher strain means higher stress and higher specific cutting resistance. Therefore, the specific cutting resistance was higher at smaller tool angles that had higher strain and stress.

Determination of Femoral and Tibial Joint Reference Angles in Small-breed Dogs

  • Kim, Jooho;Heo, Suyoung;Na, Jiyoung;Kim, Namsoo;Kim, Minsu;Jeong, Seongmok;Lee, HaeBeom
    • 한국임상수의학회지
    • /
    • 제33권6호
    • /
    • pp.340-345
    • /
    • 2016
  • The present study determined the normal reference ranges for the femoral and tibial joint orientation angles of small-breed dogs. For this purpose, 60 each of cadaveric canine femurs and tibias from normal small-breed dogs (Maltese, Poodle, Shih Tzu, Yorkshire Terrier) were examined with radiographs and photographs. Axial and frontal radiographs and photographs of each bone were obtained, from which anteversion and inclination angles, anatomic lateral proximal and distal femoral angles (aLPFA and aLDFA), mechanical lateral proximal and distal femoral angles (mLPFA and mLDFA), and mechanical medial proximal and distal tibial angles (mMPTA and mMDTA) were measured. The 95% CI for radiographic values of all femurs and tibiae were anteversion angle, $23.4-27.4^{\circ}$; inclination angle, $128.4-130.4^{\circ}$; aLPFA, $117.8-122.1^{\circ}$; aLDFA, $93.7-95.2^{\circ}$; mLPFA $113.8-117.3^{\circ}$; mLDFA $99.2-100.5^{\circ}$; mMPTA $96.8-98.5^{\circ}$; mMDTA $89.4-90.7^{\circ}$. The Maltese had a larger anteversion angle than the Poodle and the Yorkshire Terrier and a larger mLPFA than the Poodle. In the comparison between the radiographs and the photographs, significant differences were found in the anteversion angle, mLPFA, mMPTA, and mMDTA. The established normal reference values might be useful for determining whether a valgus or varus deformity of the femur or the tibia is present and if so, the degree of angular correction needed.

Reynolds Number Effects on the Non-Nulling Calibration of a Cone-Type Five-Hole Probe for Turbomachinery Applications

  • Lee, Sang-Woo;Jun, Sang-Bae
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1632-1648
    • /
    • 2005
  • The effects of Reynolds number on the non-nulling calibration of a typical cone-type five-hole probe have been investigated for the representative Reynolds numbers in turbomachinery. The pitch and yaw angles are changed from - 35 degrees to 35 degrees with an angle interval of 5 degrees at six probe Reynolds numbers in range between $6.60{\times}10^3\;and\;3.17{\times}10^4$. The result shows that not only each calibration coefficient itself but also its Reynolds number dependency is affected significantly by the pitch and yaw angles. The Reynolds-number effects on the pitch- and yaw-angle coefficients are noticeable when the absolute values of the pitch and yaw angles are smaller than 20 degrees. The static-pressure coefficient is sensitive to the Reynolds number nearly all over the pitch- and yaw-angle range. The Reynolds-number effect on the total-pressure coefficient is found remarkable when the absolute values of the pitch and yaw angles are larger than 20 degrees. Through a typical non-nulling reduction procedure, actual reduced values of the pitch and yaw angles, static and total pressures, and velocity magnitude at each Reynolds number are obtained by employing the calibration coefficients at the highest Reynolds number ($Re=3.17{\times}10^4$) as input reference calibration data. As a result, it is found that each reduced value has its own unique trend depending on the pitch and yaw angles. Its general tendency is related closely to the variation of the corresponding calibration coefficient with the Reynolds number. Among the reduced values, the reduced total pressure suffers the most considerable deviation from the measured one and its dependency upon the pitch and yaw angles is most noticeable. In this study, the root-mean-square data as well as the upper and lower bounds of the reduced values are reported as a function of the Reynolds number. These data would be very useful in the estimation of the Reynolds-number effects on the non-nulling calibration.

삽지각도와 Sucrose 농도가 절화 장미의 수명과 품질에 미치는 영향 (Effect of arranging Angles and Sucrose Concentration on Vase life and Quality of Cut Rose 'Marina')

  • 송채은
    • 화훼연구
    • /
    • 제19권3호
    • /
    • pp.151-157
    • /
    • 2011
  • 본 연구는 장미의 절화수명 연장과 품질을 향상시키기 위한 목적으로 삽지각도, sucrose 전처리 시간 그리고 sucrose 농도가 절화수명에 미치는 영향을 조사하기 위해서 수행하였다. Sucrose soaking 처리시 sucrose 농도는 0.5, 1 및 2% 그리고 sucrose pulsing 처리시 sucrose 농도는 0, 1, 2, 및 4%를 이용하였다. Sucrose pulsing처리는 2 hrs 및 20 hrs 전처리 한 다음 실험을 수행하였다, 시험관에 100 mL씩 각각의 보존용액을 채운 후 삽지각도는 수평($0^{\circ}$), 수직($90^{\circ}$) 그리고 중간정도($45^{\circ}$)를 유지하여 실험을 수행하였다. Sucrose soaking 처리시 sucrose 농도와 각도에 따라서 꽃잎의 개화가 영향을 받은 것으로 보아 절화수명 연장을 위해서는 sucrose 농도를 높게 하고 각도를 수직으로 유지하는 것이 좋을 것으로 사료된다. 그리고 sucrose pulsing 2hrs 및 20 hrs 전처리 후, 삽지각도 $45^{\circ}$ 처리구에서는 개화가 지연되고 색상의 유지가 양호하였으나 $90^{\circ}$ 처리구에서는 조사 시작일 부터 개화가 빠르게 진행되고 색상도 빠르게 변색이 진행되므로 절화수명연장의 측면에서 삽지각도 $90^{\circ}$는 바람직하지 못한 것으로 사료된다.

McConnell 테이핑과 Kinesio 테이핑이 무릎넙다리통증증후군 환자의 계단 올라가기 시 통증과 다리관절 각도에 미치는 영향 (Effects of McConnell Taping and Kinesio Taping on Pain and Lower Extremity Joint Angles During Stair Ascent in People with Patellofemoral Pain Syndrome)

  • 윤삼원;손호희
    • PNF and Movement
    • /
    • 제20권2호
    • /
    • pp.189-201
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effect of McConnell taping and Kinesio taping on pain and lower extremity joint angles when patients with patellofemoral pain syndrome (PFPS) ascend stairs. Methods: Fifty young adults who were experiencing anterior knee pain due to PFPS were selected as participants. Then, 25 patients were randomly assigned to the McConnell taping group and 25 to the Kinesio taping group. Pain and lower extremity joint angle were measured while ascending stairs before and after the intervention. A paired t-test was performed to evaluate the amount of change in the parameter values after the intervention within the groups, and an independent t-test was used to compare the results of the groups. Results: In the within-group comparisons, a statistically significant difference was found in both groups between the anterior knee pain scale scores recorded before and after the intervention (p < 0.05). A statistically significant difference was also found between the groups (p < 0.05). Comparison of the lower extremity joint angles at initial contact, loading response, terminal stance, and pre-swing within the groups showed that there were statistically significant differences in the hip, knee flexion, abduction, lateral rotation, and dorsiflexion angles in both the McConnell and Kinesio taping groups (p < 0.05). There was also a statistically significant difference in all angles between the groups during the following events (p < 0.05): (1) at initial contact, (2) at loading response (except hip flexion angle), (3) at terminal stance (except hip flexion and lateral rotation angles), and (4) at pre-swing (except hip, knee abduction, and inversion angles). Conclusion: McConnell taping and Kinesio taping both effectively improved the occurrence of knee pain and the lower extremity joint angles during stair ascent in patients with PFPS. However, McConnell taping had a significant impact on pain reduction and lower extremity joint angles compared to Kinesio taping.

Effects of an Ankle Foot Orthosis with Ankle Angles on Balance Performance in Healthy Adults

  • Kim, Chung-Sun;Park, Sang-Young
    • 대한인간공학회지
    • /
    • 제30권2호
    • /
    • pp.291-296
    • /
    • 2011
  • This study was designed to investigate the effects of an ankle foot orthosis(AFO) with variable ankle joint angles on balance performance in healthy adults. Eighteen healthy adults were recruited in this repeated measures design with subjects as their own controls. An AFO with four kinds of ankle joint angles(-5, 0, 5, and 10 degree) were used and balance performance was measured during single limb standing. Three trials were obtained and then averaged for data analysis. Foot pressure was measured using an F-scan system and muscle activity was measured using an MP150 system. There were significant differences in balance performance with ankle joint angles. An AFO with -5 degrees was associated with significant increases in postural sway(anterior-posterior), and in muscle activity for the medial gastrocnemius and tibialis anterior compared with other degrees of angle. Findings of this study show that angles of an AFO are related to balance performance and a joint angle of 10 degree is effective for promoting joint stability and postural control. This information can be used by clinicians to prescribe AFOs.

Dilemma of gonial angle measurement: Panoramic radiograph or lateral cephalogram

  • Radhakrishnan, Pillai Devu;Varma, Nilambur Kovilakam Sapna;Ajith, Vallikat Velath
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.93-97
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the accuracy of panoramic imaging in measuring the right and left gonial angles by comparing the measured angles with the angles determined using a lateral cephalogram of adult patients with class I malocclusion. Materials and Methods: The gonial angles of 50 class I malocclusion patients (25 males and 25 females; mean age: 23 years) were measured using both a lateral cephalogram and a panoramic radiograph. In the lateral cephalograms, the gonial angle was measured at the point of intersection of the ramus plane and the mandibular plane. In the panoramic radiographs, the gonial angle was measured by drawing a line tangent to the lower border of the mandible and another line tangent to the distal border of the ascending ramus and the condyle on both sides. The data obtained from both radiographs were statistically compared. Results: No statistically significant difference was observed between the gonial angle measured using the lateral cephalograms and that determined using the panoramic radiographs. Further, there was no statistically significant difference in the measured gonial angle with respect to gender. The results also showed a statistically insignificant difference in the mean of the right and the left gonial angles measured using the panoramic radiographs. Conclusion: As the gonial angle measurements using panoramic radiographs and lateral cephalograms showed no statistically significant difference, panoramic radiography can be considered in orthodontics for measuring the gonial angle without any interference due to superimposed images.

SRM 드라이브의 운전성능 향상을 위한 스위칭각 특성에 관한 연구 (Study on Switching Angle Characteristics for Driving Performance Improvement of SRM Drive)

  • 오석규;최대완;안진우
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.506-513
    • /
    • 2001
  • SRM의 토크는 상전류와 인덕턱스의 기울기에 따라 달라진다. 그러나 자기회로의 포화로 인하여 원하는 토크를 제어하기 어렵다. 원하는 토크를 발생시키기 위해 SRM 드라이브는 스위치-온각, 스위치-오프각 그리고 인가 접압에 의해 제어된다. 스위치-온, 오프 각 에의해 원하는 전류와 토크를 제어할수있다. 본 논문은 스위치 온, 오프각을 제어하는 최적제어방식을 제안하였다. 스위치 오프 각은 시뮬레이션과 실험을 통하여 효율을 기준으로 결정하였으며, 스위치 온각은 부하에 의해 결정되었다. 도통각은 토크제어와 속도제어를 위해 GA-신경회로망을 이용하여 제어하였다.

  • PDF

Tracing the evolution of massive galaxies; Alignment of elliptical galaxies in the Virgo cluster

  • Kim, Suk;Jeong, Hyunjin;Lee, Jaehyun;Lee, Youngdae;Joo, Seok-joo;kim, Hak-Sub;Rey, Soo-Chang
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.47.1-47.1
    • /
    • 2017
  • We study the alignment of kinematic position angles (PAkin) of early-type galaxies in the Virgo cluster using Atlas3D data. The PAkin represent the direction of the angular momentum of the galaxies better than the photometric position angles. Therefore, the alignment of their PA$_{kin}$ is a useful tool to trace the momentum direction. The early-type galaxies in the Virgo cluster have been known to be distributed as filamentary structures inside the cluster. We found that their PAkin are aligned to two directions of 20degree and -80degree. This fact is confirmed using the bootstrap test, and that is, the two alignment angles are statistically significant. Besides, these two angles are surprisingly aligned parallel to the filamentary structures inside the cluster. These results suggest that early-type galaxies were formed by major merging in the filament structures and then fall into the Virgo cluster while maintaining their position angles.

  • PDF

Modeling of IPMC (Ionic Polymer-Metal Composite) Sensor to Effectively Detect the Bending Angles of a Body

  • Park, Ki-Won
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.375-381
    • /
    • 2011
  • Ionic polymer-metal composite(IPMC) consists of an ion conductive membrane plated by metallic electrodes on both surfaces. When it bends, a voltage is generated between two electrodes. Since IPMC is flexible and thin, it can be easily mounted on the various surfaces of a body. The present study investigates a sensor system using IPMC to effectively detect the bending angles applied on IPMC sensor. The paper evaluates several R and C circuit models that describe the physical composition of IPMC and selects the best model for the detection of angles. The circuit models implemented with a charge model describe the relationship between input bending angles and output voltages. The identification of R and C values was performed by minimizing the error between the real output voltages and the simulated output voltages from the circuit models of IPMC sensor. Then the output signal of a sensor was fed into the inverse model of the identified model to reproduce the bending angles. In order to support the validation of the model, the output voltages from an arbitrary bending motion were also applied to the selected inverse model, which successfully reproduced the arbitrary bending motion.