• Title/Summary/Keyword: angled

Search Result 298, Processing Time 0.025 seconds

Heat Transfer and Total Friction Factors in the Convergent Channels with V/⋀-shaped Ribs on Two Opposite Walls (양 벽면에 V/⋀형 리브가 있는 수축 채널의 열전달과 전 마찰계수)

  • Lee, Myung-Sung;Heo, Meo-Seong;Jeong, Ui-Jae;Park, Young-Joon;Yoo, Jung-Hyun;Im, Gun-Woo;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.66-71
    • /
    • 2016
  • The measurements of heat transfer and total friction factors for turbulent flows in the convergent rectangular channels with two opposite in-line ribbed walls are reported. The study has covered three different angled ribs ($30^{\circ}$, $45^{\circ}$ and $60^{\circ}$) and Reynolds number in the range of 22,000 to 75,000. The channel, composing of ten isolated copper sections in the length of test section of 1 m, has the channel convergence ratio of $D_{ho}/D_{hi}=0.67$. The results show that the ribs pointing downstream (${\wedge}-shaped$) is somewhat greater than the ribs pointing upstream (V-shaped) in the dimensionless Nusselt number and total friction factors.

Enhanced Detection Sensitivity of Surface Plasmon Resonance Biosensing Based on Colocalized Target Molecules and Evanescent Fields (생체분자와 필드의 동시국소화를 통한 플라스몬 센서의 감도향상 연구)

  • Lee, Won-Ju;Oh, Young-Jin;Kim, Dong-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.198-203
    • /
    • 2011
  • We have conducted a theoretical study to improve the detection limit of a surface plasmon resonance (SPR) sensor by co-localizing plasmonic fields and target molecules of interest. The fields were localized by nanograting antennas, while target molecules that participate in a molecular interaction were assumed to be co-localized by angled evaporation of a dielectric mask layer on the nanograting antennas. We have performed the evaluation using an overlap integral between distributions of plasmon fields and molecules and confirmed the correlation of the overlap with the sensitivity of an SPR sensor. Based on the calculated sensor characteristics, it was found that the sensitivity, if the fields and molecules are co-localized, can be as much as ten times that of non-colocalized structure.

Dielectric Thin Film Mirror Embedded Optical Fiber Couplers (유전체 박막 거울 내장형 광섬유 결합기)

  • 신종덕
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.420-427
    • /
    • 1993
  • Dielectric thin film mirrors are embedded in multimode and single-mode fibers by a fusion splicing technique. The fibers with $45{\circ}$ angled embedded mirrors serve as ultra-compact directional couplers with low excess optical loss of 0.2 dB for multimode and 0.5 dB for single mode at 1.3 ${\mu}m$ and excellent mechanical properties. The reflectance is wavelength dependent and strongly polarization depencient. Far-field scans of the reflected output power measured with a white-light source show a pattern which is almost circularly symmetric with aspect ratio of 1.09 at 5% of the peak power. The splitting ratio in a multimode coupler measured with a diode laser source is much less dependent on input coupling conditions than in conventional fused biconical-taper couplers, indicating that these couplers are less susceptible to modal noise occuring in optical fiber communication systems. Spectral properties of multilayer internal mirrors normal to the fiber axis have been investigated experimentally, and a matrix analysis has been used to explain the results.

  • PDF

Vision-Based Displacement Measurement System Operable at Arbitrary Positions (임의의 위치에서 사용 가능한 영상 기반 변위 계측 시스템)

  • Lee, Jun-Hwa;Cho, Soo-Jin;Sim, Sung-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.123-130
    • /
    • 2014
  • In this study, a vision-based displacement measurement system is developed to accurately measure the displacement of a structure with locating the camera at arbitrary position. The previous vision-based system brings error when the optical axis of a camera has an angle with the measured structure, which limits the applicability at large structures. The developed system measures displacement by processing the images of a target plate that is attached on the measured position of a structure. To measure displacement regardless of the angle between the optical axis of the camera and the target plate, planar homography is employed to match two planes in image and world coordinate systems. To validate the performance of the present system, a laboratory test is carried out using a small 2-story shear building model. The result shows that the present system measures accurate displacement of the structure even with a camera significantly angled with the target plate.

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

Effects of Discrete Rib-Turbulators on Heat/Mass Transfer Augmentation in a Rectangular Duct (사각 덕트 내부 열전달 향상을 위한 요철의 단락 효과)

  • Kwon, Hyuk-Jin;Wu, Seong-Je;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.744-752
    • /
    • 2000
  • The influence of arrangement and length of discrete ribs on heat/mass transfer and friction loss is investigated. Mass transfer experiments are conducted to obtain the detailed local heat/mass transfer information on the ribbed wall. The aspect ratio (width/height) of the duct is 2.04 and the rib height is one tenth of the duct height, such that the ratio of the rib height to hydraulic diameter is 0.0743. The ratio of rib-to-rib distance to rib height is 10. The discrete ribs were made by dividing each continuous rib into 2, 3 or 5 pieces and attached periodically to the top and the bottom walls of the duct with a parallel orientation The combined effects of rib angle and length of the discrete ribs on heat/mass transfer ae considered for the rib angles $({\alpha})\;of\;90^{\circ}\;and\;45^{\circ}$. As the number of the discrete ribs increases, the uniformity of the heat/mass transfer distributions increases. For $(\alpha})=90^{\circ}$, the heat/mass transfer enhancement with the discrete ribs is remarkable, while the heat/mass transfer performances are slightly higher than that of the transverse continuous ribs due to the accompanied high friction loss penalty. For $(\alpha})=90^{\circ}$, the average heat/mass transfer coefficients and the heat/mass transfer performances decrease slightly with the discrete ribs compared to the case of the angled continuous ribs.

REMOVAL OF FOREIGN BODY IN THE LATERAL PHARYNGEAL SPACE VIA TRANSTONSILLAR APPROACH (편도와 접근을 통한 측방인두간극 이물제거의 치험 증례)

  • Kim, Soung-Min;Kim, Han-Seok;Kim, Ji-Hyuck;Kwon, Kwang-Jun;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.567-571
    • /
    • 2007
  • Lateral pharyngeal space is one of potential fascial planes of head and neck, that may become involved by various pathological processes, such as infection, inflammation and neoplasm. The calcified stylohyoid ligament with styloid process is also located in this space, so this space is more acquainted with Eagle's syndrome in oral and maxillofacial field. During the mandibular transbuccal fixation procedures of 29-year old female patient who had right condylar neck and left parasymphysis fracture, we had lost one 10.0 mm miniscrew. After confirming the location of the lost miniscrew from different angled plain skull radiographies, we tried to find it in the lateral pharyngeal space via transtonsillar approach at the time of plate removal operation. This case report is aimed to share our valuable experience of the effective approach way to the lateral pharyngeal space, which has many advantages, such as short operative time, minimal bleeding, fast post-operative recovery, and less morbidity. The related literature is also reviewed.

Rib-Dimple Compound Cooling Techniques in a Gas Turbine Blade Cooling Channels with an Aspect ratio (4:1) (4:1 종횡비를 갖는 가스터빈 블레이드 냉각 유로에서의 립-딤플 복합 냉각 특성 연구)

  • Choi, Yong-Duck;Kim, Seok-Beom;Lee, Yong-Jin;Kim, Jin-Kon;Kwak, Jae-Su
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.304-310
    • /
    • 2010
  • Heat transfer coefficients in a dimpled channel, a ribbed channel, and a rip-dimple compound channel were measured by the transient liquid crystal technique. The channel aspect ratio, the rib height, the rip pitch, and the rib angle were 4:1, 6 mm, 60 mm and $60^{\circ}$, respectively. The dimple diameter and the center-to-center distance were 6mm and 7.2 mm, respectively, and the Reynolds number range was 30,000-50,000. Results showed that the heat transfer coefficients were increased by the angled rib. For the dimple-rib compound cooling cases, the heat transfer coefficients were further augmented and the thermal performance factor for the case was the highest.

  • PDF

A Branch-Line Hybrid Using Triangle-Patch Type Artificial Transmission Line (삼각 패치형 인공 전송 선로를 이용한 브랜치 라인 하이브리드)

  • Oh, Song-Yi;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.768-773
    • /
    • 2012
  • A branch-line hybrid using microstrip artificial transmission lines(ATLs) with slotted-triangular patches is proposed. The proposed artificial transmission line is compact in structure as well as easy to adjust the characteristic impedance and electrical length of equivalent transmission line by changing the slot's parameters; hence, it is useful for miniaturizing conventional transmission lines. The designed branch-line hybrid, because of the use of the right angled isosceles triangular shaped artificial transmission lines as building blocks, has no useless empty space, and hence optimally miniaturized. A fabricated 3 dB branch-line hybrid shows the coupling variation of ${\pm}0.5$ dB and the phase difference between two output ports of $91^{\circ}{\pm}4^{\circ}$ within 15 % bandwidth at 2.45 GHz center frequency. The size of proposed branch-line hybrid is only 38% of the conventional branch-line hybrid.

A study on the fabrication of semiconductor laser for optical sensor (광센서 광원용 반도체 레이저의 제작에 관한 연구)

  • Kim, Jeong-Ho;An, Se-Kyung;Hwang, Sang-Ku;Hong, Tchang-Hee
    • Journal of Navigation and Port Research
    • /
    • v.26 no.2
    • /
    • pp.235-243
    • /
    • 2002
  • Theoretical analysis have been performed to design the high power semiconductor laser for an optical sensor at 1.55${\mu}{\textrm}{m}$ wavelength range which is the lowest loss wavelength in optical fiber. The materials of active region and SCH were $Ln_{1-x}Ga_xAs_yP_{1-y}$. In order to use the light source of optical sensors, it has to satisfy wide spectral width and short coherence length. Therefore, in order to suppress lasing oscillation, we proposed laterally tilted PBH type with a window region. Also, tapered stripe structure was applied for high coupling efficiency into a single mode fiber. From these analyses, the devices of laterally tilted angled and bending structure were fabricated and their characteristics were measured. In the results of the measurement, the fabricated devices have sufficient output power and wide FWHM to apply to the light source of optical fiber sensors.