• Title/Summary/Keyword: angle of shoulder

Search Result 450, Processing Time 0.032 seconds

Effects of Soft Tissue Massage of the Posterior Deltoid Muscle on Shoulder Horizontal Adduction

  • Park, Kyue-Nam;Kwon, Oh-Yun;Kim, Si-Hyun;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.35-40
    • /
    • 2010
  • Stiffness of the posterior deltoid is as a causative factor in the limited range of glenohumeral horizontal adduction and various other shoulder pathologies including shoulder impingement syndrome, frozen shoulder, and humerus anterior glide syndrome. The purpose of this study was to compare the effects of two techniques (soft tissue massage and cross-body stretch) on increasing the range of horizontal adduction. Thirty-two subjects with a $10^{\circ}$ or greater difference between the right and left sides in horizontal adduction were selected. Sixteen subjects from each group were allocated randomly. Interventions were applied on six occasions for 2 weeks, and the range of horizontal adduction was measured using an inclinometer at pre-and post-intervention. A $2{\times}2$ analysis of variance (intervention${\times}$time) was used to compare the effects of the two techniques. In the soft tissue massage group, the angle of horizontal adduction significantly increased compared with the cross-body stretch group. These findings indicate that the soft tissue massage of the posterior deltoid muscle is a more effective method to increase the flexibility of the glenohumeral horizontal adduction.

Effects of Intentional Abdominal Muscle Contraction on Lumbar Muscle Activities andLumbar Extension During Lifting Above the Shoulders (어깨위로 들어올리기 작업시 의도적인 복근수축이 요부근 활성도와요추신전각도에 미치는 영향)

  • Kim, Hui-Won;Gwon, O-Yun;Lee, Chung-Hwi;Jeon, Hye-Seon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.147-154
    • /
    • 2006
  • This study was conducted to evaluate the effect intentional contraction of abdominal muscles during lifting above shoulder on the muscles activities of the lower trunk and on the degree of lumbar extension. Fifteen healthy adult males were selected as test subjects. A 5kg weight was raised to the shoulder level, 20cm, and 40cm above the shoulder level. EMG activities of all muscles except the rectus abdominis were significantly greater when subjects were asked to contract their abdominal muscles intentionally during lifting(p<0.05). Degree of lumbar extension also significantly decreased with intentional abdominal contraction during the lifting. Also, degree of lumbar extension significantly increased with increase in lifting height(p<0.05). The results of this study show that intentional contraction of abdominal muscles during lifting above shoulder increases the EMG activities of external abdominis oblique, internal abdominis oblique, and erector spinae.

Comparison of Scapular Position Between Operation and Non-operation Side to the Rotator Cuff Surgery (회전근개 수술 환자의 수술측과 비수술측 간에 견갑골 자세 비교)

  • Jeong, Eui-young;Kim, Suhn-yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.2
    • /
    • pp.15-20
    • /
    • 2016
  • Background: The purpose of this study was to compared of scapular position between operation side and non-operation side to the rotator cuff surgery. Methods: This study was carried out with a total 34 patients: male (n=14), female (n=20). Shoulder range of motion (ROM), the quadruple visual analogue scale (QVAS), the shoulder pain and disability index (SPADI), and the scapular index (SI) were used to assess shoulder posture and function. SI was the resting position of the scapular was determined by measuring the distance from the mid-point of the sternal notch (SN) to the medial aspect of the coracoid process (CP) and the horizontal distance from the posterolateral angle of the acromion (PLA) to the thoracic spine (TS) with a soft tape measure. The SI was calculated using the equation: [(SN to CP/PLA to TS) ${\times}$ 100]. Results: There were no significant difference in ROM, QVAS to rotator repair patients according to SI (p>.05). There were significant differences in SI between the operation side and the non-operation side (p<.01). Conclusions: Scapular position was operation side more internal rotation, protraction, abduction than non-operation side. Therefore, health professionals managing for rotator cuff tear repair patients should consider scapular position.

  • PDF

Significant radiologic factors related to clinical outcomes after arthroscopic rotator cuff retear repair

  • Joo, Min-Su;Kim, Jeong-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.173-181
    • /
    • 2022
  • Background: Healing of the tendon itself is not always related to successful clinical outcomes after rotator cuff repair. It was hypothesized that certain radiologic factors affecting clinical outcomes could exist in case of the retear after arthroscopic rotator cuff repair (ARCR) and the radiologic factors could help predict clinical process. The purpose of this study was to identify the radiologic factors associated with clinical outcomes of the retear after ARCR. Methods: Between January 2012 and December 2019, among patients with sufficient footprint coverage for ARCR, 96 patients with Sugaya classification 4 or higher retear on follow-up magnetic resonance imaging were included. The association between clinical outcomes such as American Shoulder and Elbow Surgeons (ASES) score, Constant score and range of motion and radiologic variables such as initial tear dimension, retear dimension, variance of tear dimension, critical shoulder angle, acromial index, and acromiohumeral distance was analyzed. Results: Preoperatively, the ASES and Constant scores were 59.81±17.02 and 64.30±15.27, respectively. And at the last follow-up, they improved to 81.56±16.29 and 78.62±14.16, respectively (p<0.01 and p<0.01). In multiple linear regression analysis, the variance of the mediolateral dimension of tear had statistically significant association with the ASES and Constant scores (p<0.01 and p=0.01). Conclusions: In patients with the retear after ARCR, the variance in the mediolateral dimension of tear had significantly negative association with the clinical outcomes. This could be considered to be reference as relative criteria and needed more sample and mechanical study.

A Study on the Cloth Design for Elderly Women to Mask Their Dorsal Curvature (노년기여성의 배면만곡도 감소효과를 위한 의복디자인 연구)

  • Kim Tae-Kyung;Lee Kyoung-Hi;Park Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.14 no.3 s.35
    • /
    • pp.183-195
    • /
    • 1990
  • The author has studied the effect of clothes design to mask the dorsal curvature that is one of the commonest changes in elderly women. Body measurements including the body type and the status of dorsal curvature were perfor-med on 153 women of over 60 years of age, and then a body form to fit to the mean measure-ments was made to evaluate the effects of various designs to it. With 31 pattern designs modified by changing in their slash lines and gathers using darts, the diminishing effect of the rounded back were evaluated by means of sensory test. The results of this study can be summarized as follows: I . Results from the body measurements 1) The mean body type in elderly women was that of obesity. 2) With the advancement of age, the angle to indicate the degree of dorsal curvature as well as the angle to indicate the posture are increased. II . Concerning to the clothes design to diminish the shape of dorsal curvature 1) Among the designs by the position of darts, the basic pattern (Fig. 5-1-(1)) showed the best effect to mask the shape of dorsal curvature. 2) Out of the applied designs of princess lines, that in which the slash line is pointing toward the shoulder point (Fig. 5-2-(1)) seemed to be most effective. 3) What has angled princess line (Fig. 5-3-(1)) had the most diminishing effect among the waist darts and armhole princess lines. 4) Among the V-shaped designs, the slashed at the shoulder point (Fig. 5-4-(1)) had the best effect to lessen the shape of the dorsal cuuature. 5) Wider angle yoke had better effect to the narrow angle one among the designs with straight yoke, and that with downward direction (Fig. 5-5-(1)) showed the best effect. 6) Between straight wide angle yoke and curved yoke, that of curved one with downward direction (Fig. 5-6-(1)) had better effect as far as the masking effect of dorsal curvature is concerned. 7) Gathers around the neck showed better effect to those around the shoulder, and the more amount of gathers (Fig. 5-7-(1)), there was better effect. 8) The design with midline gathers at the level of horizontal slash line of armhole (Fig. 5-8-(1)) showed better effect to that with seperated gathers. 9) In case of design with gathers at the horizontal line of armhole, it showed the better effect with less amount of gathers in midline ones, but with more amount in the side ones. 10) Considering all 7 different designs with better effect in covering the shape of dorsal curvature, it was evident that the design with gathers was far better than the design with application of slash lines.

  • PDF

MARGINAL FIT RELATED TO MARGIN TYPES OF GLASS INFILTRATED ALUMINA CORE FABRICATED FROM AQUEOUS-BASED ALUMINA TAPE

  • Oh, Nam-Sik;Yu, Byeung-Su;Kim, Il-Kyu;Choi, Jin-Ho;Kim, Dae-Joon;Park, Il-Seok;Lee, Myung-Hyun;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.262-268
    • /
    • 2002
  • Statement of problem. In-Ceram system is one of the all-ceramic crowns that can be used in anterior 3 unit fixed partial dentures and posterior single crowns. The alumina core used in In-Ceram system is manufactured using slip-casting technique. The slip-casting technique is difficult and technique sensitive. To improve this problem, tape-casting method was introduced into dentistry. There were no studies to examine the effect of margin design on the margin fitness of all-ceramic crowns fabricated from alumina tape. Purpose. The purpose of this study was to compare the marginal fitness of glass infiltrated alumina core fabricated from aqueous-based alumina tape according to different margin types ($90^{\circ},\;110^{\circ},\;135^{\circ}$ shoulder margin). Material and method. Three upper central resin incisors were prepared with $90^{\circ},\;110^{\circ}$, and $135^{\circ}$ shoulder margins for all-ceramic crowns, respectively. The resin teeth were duplicated and master die and special plaster die were made as usual. After alumina cores were fabricated from aqueous-based alumina tape, cores were cemented to each 15 epoxy dies replicated from three resin teeth with resin cement. These cemented cores were embedded in epoxy resin. Specimens were cut mesiodistally and buccolingually. Marginal gap and discrepancy were measured under microscope. Results. The marginal gap and discrepancy of $90^{\circ}$ marginal angle was $75.1{\mu}m,\;86.6{\mu}m,\;110^{\circ}$ marginal angle was $41.5{\mu}m,\;50.7{\mu}m$ and $135^{\circ}$ marginal angle was $51.7{\mu}m,\;54.2{\mu}m$, respectively. The smallest value was seen in 110 (angle, which was statistically significant compared to that of $90^{\circ}$ angle (p<0.05). Conclusion. Marginal fitness of alumina cores made of alumina tape with $110^{\circ}$ shoulder margin was best and others were clinically acceptable.

Effects of Thoracic Expansion and Diaphragm Breathing Exercises on Pain and Function in Patients with Rotator Cuff Repair (가슴우리팽창과 가로막 호흡운동이 돌림근띠 복원술 환자의 통증과 기능에 미치는 효과)

  • Myung-Soo Song;Beom-Ryong Kim
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.95-105
    • /
    • 2023
  • Purpose: The study aims to determine the effect of a breathing exercise on shoulder pain, range of motion (ROM), and forward head posture in patients with rotator cuff repair. Methods: In total, 25 patients with rotator cuff repair were included in this study. The experimental group (n = 13) underwent a breathing exercise, while the control group (n = 12) received traditional physical therapy. The visual analogue scales (VASs) for pain, flexion and abduction ROM, and the craniovertebral angle (CVA) of both groups were recorded at both pre- and post-intervention. Paired t-tests were used to determine significant changes in the post-intervention compared with the pre-intervention period, and independent t-tests were used to analyze differences in dependent variables between the two groups. Results: After the two-week intervention, the experimental group experienced a significantly decreased VAS (p < 0.05) and significantly increased ROM and CVA (p < 0.05), while the control group experienced a significantly decreased VAS (p < 0.05). Further, the experimental group that underwent the breathing exercise showed greater improvements in flexion and abduction ROM and in the CVA than the control group (p < 0.05). Conclusion: The results suggested that a breathing exercise can reduce shoulder pain and enhance ROM and posture in patients with rotator cuff repair.

A New Anterior Approach for Fluoroscopy-guided Suprascapular Nerve Block - A Preliminary Report -

  • Kang, Sang-Soo;Jung, Jae-Woo;Song, Chang-Keun;Yoon, Young-Jun;Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.168-172
    • /
    • 2012
  • Background: The aim of the study was to investigate the feasibility of fluoroscopy-guided anterior approach for suprascapular nerve block (SSNB). Methods: Twenty patients with chronic shoulder pain were included in the study. All of the nerve blocks were performed with patients in a supine position. Fluoroscopy was tilted medially to obtain the best view of the scapular notch (medial angle) and caudally to put the base of coracoid process and scapular spine on same line (caudal angle). SSNB was performed by introducing a 100-mm, 21-gauge needle to the scapular notch with tunnel view technique. Following negative aspiration, 1.0 ml of contrast was injected to confirm the scapular notch, and 1 % mepivacaine 2 ml was slowly injected. The success of SSNB was assessed by numerical rating scale (NRS) before and after the block. Results: The average NRS was decreased from $4.8{\pm}0.6$ to $0.6{\pm}0.5$ after the procedure (P < 0.05). The best view of the scapular notch was obtained in a medial angle of $15.1{\pm}2.2$ ($11-19^{\circ}$) and a caudal angle of $15.4{\pm}1.7^{\circ}$ ($12-18^{\circ}$). The average distance from the skin to the scapular notch was $5.8{\pm}0.6$ cm. None of the complications such as pneumothorax, intravascular injection, and hematoma formation was found except one case of partial brachial plexus block. Conclusions: SSNB by fluoroscopy-guided anterior approach is a feasible technique. The advantage of using a fluoroscopy resulted in an effective block with a small dose of local anesthetics by an accurate placement of a tip of needle in the scapular notch while avoiding pneumothorax.

Comparison of Gait Stability of using an Outdoor Rollator with Walking and using a Bassinet as Ambulatory Aid

  • Park, Min-Su;Park, Soo-Hee;Yang, Yeong-Ae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.2
    • /
    • pp.327-336
    • /
    • 2012
  • Objective: The purpose of this study is to find the problems of stability when people use the bassinet as an ambulatory aid for old people. Background: Many aged people use a bassinet as ambulatory aid. But the safety of using the bassinet as ambulatory aid has not been verified yet. Method: The 13 university-students who don't have musculoskeletal disorders volunteered to participate in this study. According to structural analysis of the both tools, we compared the structural stability of an outdoor rollator with the structural stability of a bassinet. And when the participants walked using both tools, the motions were captured and analysed. We measured the angle of shoulder joint and the angle of trunk from the ground when the participants were walking. And we found the distance from participants' pressure cone apex and greater trochanter. Results: Following the structural analysis, the bassinet has the lower structural stability than the outdoor rollator. When the people used the bassinet as ambulatory aid, the angle of the shoulder joint was bigger than to use the outdoor rollator. The angle of trunk wasn't different between the outdoor rollator and the bassinet. And distance from pressure cone apex to greater trochanter was far to use the bassinet than to use the outdoor rollator. Conclusion: Through the structure analysis and gait analysis of the bassinet and the outdoor rollator, we can be aware of that the bassinet has problem of stability. Therefore the people who use the bassinet as an ambulatory aid, especially supporting body weight, may be hurt due to the problems of stability. Application: This research can be used for developing a study of the ambulatory aid and preventing the accident when the aged people use the ambulatory aid.

A Clothing Ergonomics Studyon the Seelve form Variation and the Clothing Pressure Variation According to Arm Movement (동작에 따른 상지형태 변화와 의복에 대한 피복인간공학적 연구(I))

  • Kim Hae-Kyung;Kim Soon-Ja;Cho Jung Mee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.2 s.27
    • /
    • pp.237-248
    • /
    • 1988
  • To access the appropriate height of sleeve cap which is required for the basic sleeve pattern according to arm movements, plaster gypsum experiment was performed. Arm movements were 5types ($0^{\circ},\;45^{\circ},\;90^{\circ},\;135^{\circ},\;180^{\circ}$) to the vertical directions in the front. The appropriateness of the pattern was analyzed by measuring clothing pressure. The results obtained were as follows: 1. Increasing the movement angle, sleeve width increased but height of sleeve cap and armhole girth decreased. 2. Increasing the movement angle, the acromion moved to the front part of bodice. 3. On the basis of the result of the height of sleeve cap, the $\frac{AH}{4} +2.5cm$ sleeve basic 4 pattern is suitable for the direction $M_1(0^{\circ}),\;M_2(45^{\circ})$, and the $\frac{AH}{5}$sleeve basic pattern is suitable for the direction $M_3(90^{\circ}),\;M_4(135^{\circ})$, and $M_5(180^{\circ})$. 4. As the movement angle and height of sleevecap increased, the part which receive high pressure increased and the difference between the hightest and the lowest clothing pressure increased. 5. By the variation of movement angle and height of sleevecap, clothing pressure of upperarm was affected more than that of shoulder blade. 6. The clothing pressure of upperarm and shoulder blades were more affected by the height of sleeve cap than the ease of breast area. 7. Considering the clothing pressure of various arm movement, the most appropriate height of sleeve cap for $M_1(0^{\circ}),\;M_2(45^{\circ})$ positions was to use the $\frac{AH}{4}$+2.5cm, and for $M_3(90^{\circ}),\;M_4(135^{\circ})$, and $M_5(180^{\circ})$, was $\frac{AH}{5}$.

  • PDF