• Title/Summary/Keyword: and resonance

Search Result 10,656, Processing Time 0.04 seconds

A Study on Clinical Findings about Vertebral Disease Diagnosed with MRI (MRI로 진단된 척추질환의 임상적 소견)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.157-165
    • /
    • 2006
  • In order to analyze clinical characteristics like sex- and age-based onset frequency and onset region from vertebral disease cases, this study investigated total 1,291 cases of vertebral disease that were diagnosed via magnetic resonance imaging(MRI) from January to December 2004 at B University Hospital in metropolitan area. For higher diagnostic accuracy in cases of spinal disorder diagnosed, this study analyzed findings from data reading conducted by veteran specialists in diagnostic radiology. But this study excluded uncertain lesion cases, the cases requiring differential diagnosis from other disorders and so on from subjects under analysis. This study employed superconductive 1.5 Tesla SIGNA MR/i for MRI test and basically received resulting images via FSE(fast spin echo). In particular, this study obtained T1 and T2 myelogram with regard to regional characteristics(such as cervical vertebrae, thoracic vertebrae and lumbar vertebra) and imaging characteristics for sagittal and transverse section. As a result, this study came to the following conclusions : 1. In terms of general characteristics of subjects under analysis, male group comprised 53.5% and female 46.5% out of total 1,291 subjects. 2. The regional onset frequency of spinal disorders was converged primarily on lumbar vertebra(65.5%), which was followed by cervical vertebrae(27.3%) and thoracic vertebrae(7.0%) respectively. 3. Top 10 cases with high onset frequency of spinal disorders can be listed as follows : 1) posterior bulging disc 65.8% 2) narrowing of neural foramen 23.8% 3) herniated intervertebral disc (HIVD) 22.4% 4) spinal stenosis 16.7% 5) osteochondrosis 6.4% 6) compression fracture 6.4% 7) facet joint arthropathy 6.2% 8) spondylolisthesis 6.0% 9) spinal cord tumor 3.5% 10) inter body fusion 2.6%

  • PDF

Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System

  • Cho, Jin Dong;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in;Wu, Hong-Gyun;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.190-196
    • /
    • 2017
  • For the $ViewRay^{(R)}$ system (ViewRay Inc., Cleveland, OH, USA) which is representative of magnetic resonance (MR) guided radiotherapy machine, it is important to evaluate effectiveness of AAPM's TG-51 protocol and the effect of the magnetic field on absolute dosimetry. In order to measure the absolute dose, MR-compatible chamber and water phantom system manufactured in this study were used. The materials of the water phantom system were plastic of polymethyl methacrylate (PMMA) and non-ferrous materials. Due to the inherent feature of the $ViewRay^{(R)}$, all Co-60 sources are not located at gantry angle of $0^{\circ}$ while being located at gantry angle of $90^{\circ}$. For this reason, absolute dosimetry was performed based on the measurements in solid water phantom (SWP) and water which determine the SWP to water correction factor. For evaluation of output constancy with gantry angle, measurements were made with ionization chamber inserted in cylindrical water-equivalent phantom. For measured doses in water, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -0.27%, -0.45% and -0.22%, respectively. For measured doses in SWP, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -1.91%, -2.07% and -1.84%, respectively. All values of dose measured in SWP tended to be less than those measured in water by -1.63%. With the reference gantry angles of $0^{\circ}$ and $90^{\circ}$, the maximum values of deviation for Head 1, Head 2 and Head 3 were 0.48%, 1.06% and 0.40%, respectively. The measurement agreement is within the range of results obtainable for conventional treatment machines. The low strength of the magnetic field does not affect dose measurements. Using the SWP to water correction factor, absolute doses for $ViewRay^{(R)}$ system can be measured.

An fMRI study on the cerebellar lateralization during visuospatial and verbal tasks (공간 및 언어 과제 수행 시 소뇌의 편측화에 관한 뇌 기능 연구)

  • Chung, Soon-Cheol;Sohn, Jin-Hun;Choi, Mi-Hyun;Lee, Su-Jeong;Yang, Jae-Woong;Lee, Beob-Yi
    • Science of Emotion and Sensibility
    • /
    • v.12 no.4
    • /
    • pp.425-432
    • /
    • 2009
  • The purposes of the study were to examine cerebellar areas and lateralization responsible for visuospatial and verbal tasks using functional Magnetic Resonance Imaging(fMRI). Eight healthy male college students($21.5\;{\pm}\;2.3$ years) and eight male college students($23.3\;{\pm}\;0.5$ years) participated in this fMRI study of visuospatial and verbal tasks, respectively. Functional brain images were taken from 3T MRI using the single-shot EPI method. All functional images were aligned with anatomical images using affine transformation routines built into SPM99. The experiment consisted of four blocks. Each block included a control task(1 minute) and a cognitive task(1 minute). A run was 8 minutes long. Using the subtraction procedure, activated areas in the cerebellum during the visuospatial and verbal tasks were color-coded by t-score. A cerebellar lateralization index was calculated for both cognition tasks using number of activated voxels. The activated cerebellar regions during the both cognition tasks of this study agree with previous results. Since the number of activated voxels of the left and right cerebellar hemisphere was almost same, there was no cerebellar lateralization for both cognition tasks.

  • PDF

Size and Location of Ruptured Intracranial Aneurysms

  • Jeong, Young-Gyun;Jung, Yong-Tae;Kim, Moo-Seong;Eun, Choong-Ki;Jang, Sang-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • Objective : The aim of study was to review our patient population to determine whether there is a critical aneurysm size at which the incidence of rupture increases and whether there is a correlation between aneurysm size and location. Methods : We reviewed charts and radiological findings (computed tomography (CT) scans, angiograms, CT angiography, magnetic resonance angiography) for all patients operated on for intracranial aneurysms in our hospital between September 2002 and May 2004. Of the 336 aneurysms that were reviewed, measurements were obtained from angiograms for 239 ruptured aneurysms by a neuroradiologist at the time of diagnosis in our hospital. Results : There were 115 male and 221 female patients assessed in this study. The locations of aneurysms were the middle cerebral artery (MCA, 61), anterior communicating artery (ACoA, 66), posterior communicating artery (PCoA, 52), the top of the basilar artery (15), internal carotid artery (ICA) including the cavernous portion (13), anterior choroidal artery (AChA, 7), A1 segment of the anterior cerebral artery (3), A2 segment of the anterior cerebral artery (11), posterior inferior cerebellar artery (PICA, 8), superior cerebellar artery (SCA, 2), P2 segment of the posterior cerebral artery (1), and the vertebral artery (2). The mean diameter of aneurysms was $5.47{\pm}2.536\;mm$ in anterior cerebral artery (ACA), $6.84{\pm}3.941\;mm$ in ICA, $7.09{\pm}3.652\;mm$ in MCA and $6.21{\pm}3.697\;mm$ in vertebrobasilar artery. The ACA aneurysms were smaller than the MCA aneurysms. Aneurysms less than 6 mm in diameter included 37 (60.65%) in patients with aneurysms in the MCA, 43 (65.15%) in patients with aneurysms in the ACoA and 29 (55.76%) in patients with aneurysms in the PCoA. Conclusion : Ruptured aneurysms in the ACA were smaller than those in the MCA. The most prevalent aneurysm size was 3-6 mm in the MCA (55.73%), 3-6 mm in the ACoA (57.57%) and 4-6 mm in the PCoA (42.30%). The more prevalent size of the aneurysm to treat may differ in accordance with the location of the aneurysm.

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF

Clinical Characteristics and Treatment Effects of Shoulder Pain Patients Admitted to a Korean Medicine Hospital Based on MRI Findings (한방병원에 입원한 견통 환자들의 MRI소견에 따른 임상적 특징, 한방치료 효과에 대한 비교고찰)

  • Lim, Su Jin;Jun, Jae Yun;Lee, Chong Whan;Kim, Hae Sol;Kim, Ho Sun;Bae, Young Hyun;Ahn, Ji Hoon
    • Journal of Acupuncture Research
    • /
    • v.31 no.4
    • /
    • pp.109-119
    • /
    • 2014
  • Objectives : The aim of this study is to observe clinical characteristics and treatment outcomes of inpatients admitted to a Korean medicine hospital for shoulder pain based on magnetic resonance imaging(MRI) findings. Methods : 28 patients with MRI data were included. Data on MRI findings, duration of pain, and treatment effects were collected. To measure treatment outcomes, verbal numerical rating scale(VNRS), range of motion(ROM), and a clinical condition grading system were used. Results : 1. The patient population was 75.0 % female and 39.3 %(n=11) belonged to the 51~60-year-old age group. In the under 40 population, 1 or less MRI findings were found. 2. As for the type of disorder, 82.1 % of the patients were diagnosed with 'Supraspinatus lesion', 39.3 % with 'subacromial-subdeltoid(SA-SA) bursitis', and 28.6 % with 'Adhesive capsulitis' 3. Numerous correlations could be made between duration of pain and MRI findings. 'rotator cuff full thickness tear' was more prevalent in acute shoulder pain patients, and 'Adhesive capsulitis' in chronic patients. 4. VNRS and ROM at the time of discharge had significantly improved as compared to VNRS and ROM at the time of admission. 5. As for correlation between MRI findings and clinical condition grade, patients diagnosed with 'rotator cuff partial tear' reported to be in 'good' condition or better whereas those with 'rotator cuff full thickness tear' reported to be in 'fair' condition or worse. Conclusions : Patients admitted to a Korean Medicine hospital for shoulder pain had varying degrees of severity as shown on MRI. Almost all lesions responded well to Korean medicine treatment.

Neural Activation in the Somatosensory Cortex by Electrotactile Stimulation of the Fingers: A Human fMRI Study

  • Seok, Ji-Woo;Jang, Un-Jung;Sohn, Jin-Hun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.395-405
    • /
    • 2014
  • Objective: The aim of this study is to investigate 1) somatotopic arrangement of the second and third fingers in SI area 2) difference of neural activation in the SI area produced by stimulation with different frequencies 3) correlation between the intensity of tactile perception by different stimulus intensity and the level of brain activation measurable by means of fMRI. Background: Somatosensory cortex can obtain the information of environmental stimuli about "where" (e.g., on the left palm), "what" (e.g., a book or a dog), and "how" (e.g., scrub gently or scrub roughly) to organism. However, compared to visual sense, the neural mechanism underlying the processing of specific electrotactile stimulus is still unknown. Method: 10 right-handed subjects participated in this study. Non-painful electrotactile stimuli were delivered to two different finger tips of right hand. Functional brain images were collected from 3.0T MRI using the single-shot EPI method. The scanning parameters were as follows: TR and TE were 3000, 35ms, respectively, flip angle 60, FOV $24{\times}24cm$, matrix size $64{\times}64$, slice thickness 4mm (no gap). SPM5 was used to analyze the fMRI data. Results: Significant activations produced by the stimulation were found in the SI, SII, the subcentral gyrus, the precentral gyrus, and the insula. In all participants, statistically significant activation was observed in the contralateral SI area and the bilateral SII areas by the stimulation on the fingers but ipsilaterally dominant. The SI area representing the second finger generally located in the more lateral and inferior side than that of the third finger across all the subjects. But no difference in brain area was found for the stimulation of the fingers by different frequencies. And two typical patterns were observed on the relationship between the perceived psychological intensity and the amount of voxels in the primary sensory cortex during the stimulation. Conclusion: It was possible to discriminate the representation sites in the SI by electrotactile stimulation of digit2 and digit3. But we could not find the differences of the brain areas according to different stimulation frequencies from 3 to 300Hz. Application: The results of the study can provide a deeper understanding of somatosensory cortex and offer the information for tactile display for blinds.

Effects on the Oxidation Rate with Silicon Orientation and Its Surface Morphology (실리콘배향에 따른 산화 속도 영향과 표면 Morphology)

  • Jeon, Bup-Ju;Oh, In-Hwan;Um, Tae-Hoon;Jung, Il-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.395-402
    • /
    • 1997
  • The $SiO_2$ films were prepared by ECR(electron cyclotron resonance) plasma diffusion method, Deal-Grove model and Wolters-Zegers-van Duynhoven model were used to estimate the oxidation rate which was correlated with surface morphology for different orientation of Si(100) and Si(111). It was seen the $SiO_2$ thickness increased linearly with initial oxidation time. But oxidation rate slightly decrease with oxidation time. It was also shown that the oxidation process was controlled by the diffusion of the reactive species through the oxide layer rather than by the reaction rate at the oxide interface. The similar time dependency has been observed for thermal and plasma oxidation of silicon. From D-G model and W-Z model, the oxidation rate of Si(111) was 1.13 times greater than Si(100) because Si(111) had higher diffusion and reaction rate, these models more closely fits the experimental data. The $SiO_2$ surface roughness was found to be uniform at experimental conditions without etching although oxidation rate was increased, and to be nonuniform due to etching at experimental condition with higher microwave power and closer substrate distance.

  • PDF

Reversible Data Hiding and Message Authentication for Medical Images (의료영상을 위한 복원 가능한 정보 은닉 및 메시지 인증)

  • Kim, Cheon-Shik;Yoon, Eun-Jun;Jo, Min-Ho;Hong, You-Sik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • Nowadays, most hospitals have been used to create MRI or CT and managed them. Doctors depend on fast access to images such as magnetic resonance imaging (MRIs), computerized tomography (CT) scans, and X-rays for accurate diagnoses. Those image data are related privacy of a patient. Therefore, it should be protected from hackers and managed perfectly. In this paper, we propose a data hiding method into MRI or CT related a condition and intervention of a patient, and it is suggested that how to authenticate patient information from an image. In this way, we create hash code using HMAC with patient information, and hash code and patient information is hided into an image. After then, doctor will check authentication using HMAC. In addition, we use a reversible data hiding DE(Difference Expansion) algorithm to hide patient information. This technique is possible to reconstruct the original image with stego image. Therefore, doctor can easily be possible to check condition of a patient. As a consequence of an experiment with MRI image, data hiding, extraction and reconstruct is shown compact performance.

Studies on Standardization of Licorice Based on Its Active Components with On-line HPLC Bioassay System (실시간 활성시스템을 접목한 감초의 유효성분에 대한 표준화 연구)

  • Hong, Jae Seung;Kang, Bum Gu;Jang, Young Soo;Kim, Seon Ha;Wang, Zhiqiang;Park, Yoon Ha;Park, Jong Hyuk;Lim, Soon Sung
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.401-414
    • /
    • 2014
  • In an attempt to evaluate licorice quality based on its biological activity, we grafted an on-line high-performance liquid chromatography (HPLC) bioassay method into the previously established HPLC analysis method. The common antioxidant peaks in licorices of various origin were observed through an on-line HPLC/DPPH system leading to a decrease in absorbance at 517 nm for 2,2-diphenyl-1-picrylhydrazyl (DPPH). Among them, the licorice from Youngju possessed the highest activity. Therefore, three active standard compounds from the dehydroglyasperin C, dehydroglyasperin D, and isoangustone A, were isolated and elucidated by medium pressure liquid chromatography (MPLC) and instrumental analysis such as nuclear magnetic resonance (NMR), respectively. On-line HPLC/ABTS analysis method with the simultaneous determination of three standard compounds and their radical scavenging activity was established for the quality evaluation of licorices. 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid radicals (ABTS) which is stable and effective was used in replace of DPPH. The radical scavenging activity of three standards is compared with that of Trolox, known as antioxidant, showing a negative peak with a decrease in absorbance at 734 nm for ABTS. This on-line HPLC/ABTS analysis method was validated for specificity, linearity, precision and accuracy in compliance with international conference on harmonization (ICH) guideline.