• Title/Summary/Keyword: and resonance

Search Result 10,602, Processing Time 0.034 seconds

Comparative Evaluation of North American Symptomatic Carotid Endarterectomy Trial and Warfarin-Aspirin Symptomatic Intracranial Disease Methods for Measurement of Middle Cerebral Artery Stenosis in Digital Subtraction Angiography and Magnetic Resonance Angiography (디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가)

  • Lee, Jung-Hoon;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.351-356
    • /
    • 2019
  • This study aimed to determine whether there was a difference in measurements between North American Symptomatic Carotid Endarterectomy Trial(NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease(WASID) methods that measure the middle cerebral artery stenosis in Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA). It involved 24 patients who had completed both DSA and MRA among patients with Middle Cerebral Artery (MCA) stenosis. The Middle Cerebral Artery (MCA) stenosis was measured using the NASCET and WASID methods through a retrospective analysis. For the NASCET and WASID methods, they performed measurements on normal blood vessels located far from and close to the stenosis, respectively. The mean value and standard deviation of the Digital Subtraction Angiography (DSA) measured by the NASCET method were 59.23% and 13.27%. On the other hand, those of the Digital Subtraction Angiography (DSA) measured by the WASID method were 66.64% and 12.47%. And, the mean value and standard deviation of the Magnetic Resonance Angiography (MRA) measured by the NASCET method were 49.82% and 12.06%. By contrast, those of the Magnetic Resonance Angiography (MRA) measured by the WASID method were 56.63% and 10.67%. All the p-values obtained by the Pearson and Spearman correlation tests in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) were <0.01. In conclusion, this study suggests that both the NASCET and WASID methods to measure the middle cerebral artery stenosis in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) can be used if they are not used interchangeably.

A Novel ZCS High Frequency Inverter in Complex Resonance Applied for Reduction of PM

  • Kubota, Sachio;Hatanaka, Yoshihiro
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1036-1041
    • /
    • 1998
  • A novel ZCS high frequency inverter in complex resonance applied for reduction of PM is developed. This inverter is suppressed the switching stress by using complex resonance. The stable operation is realized by ZCS using overlapping commutation phenomenon. The ZCS characteristics are investigated based on numerical analysis and experimental results.

  • PDF

A passive vibration isolator with bio-inspired structure and inerter nonlinear effects

  • Jing Bian;Xu-hong Zhou;Ke Ke;Michael CH Yam;Yu-hang Wang;Yue Qiu
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.221-238
    • /
    • 2023
  • This paper developed and examined a novel passive vibration isolator (i.e., "X-inerter") motivated by combining a bio-inspired structure and a rack-pinion inerter. The bio-inspired structure provided nonlinear stiffness and damping owing to its geometric nonlinearity. In addition, the behavior was further enhanced by a gear inerter that produced a special nonlinear inertia effect; thus, an X-inerter was developed. As a result, the X-inerter can achieve both high-static-low-dynamic stiffness (HSLDS) and quasi-zero stiffness (QZS), obtaining ultra-low frequency isolation. Furthermore, the installed inerter can produce a coupled nonlinear inertia and damping effect, leading to an anti-resonance frequency near the resonance, wide isolation region, and low resonance peak. Both static and dynamic analyses of the proposed isolator were conducted and the structural parameters' influence was comprehensively investigated. The X-inerter was proven to be comparatively more stable in the ultra-low frequency than the benchmarking QZS isolator due to the nonlinear damping and inertia properties. Moreover, the inertia effect could suppress the bio-inspired structure's super- and sub-harmonic resonance. Therefore, the X-inerter isolator generally possesses desirable nonlinear stiffness, nonlinear damping, and unique nonlinear inertia, designed to achieve the ultra-low natural frequency, the anti-resonance property, and a wide isolation region with a low resonance peak.

Study on the wave resonance-stimultion and receptionfor the BIO-KI (생체 기에 대한 피동공명적인 연구)

  • Ryu Gyeong Ho;Kim Gyeong Cheol;Lee Yong Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.2
    • /
    • pp.263-274
    • /
    • 2003
  • The present condition of study on the wave-resonance for the bio-KI is observed. And the probroms of reception attendent on the stimulation of wave is observed centering around the sensory organ. The results is as follows: In the wave-resonant stand point, the tendency of studying on KI is showed in the several field all over the world. Because it is originated radionics, the wave-resonant tools of MRA insistenting minute-magnetism-resonance-apparatus need the more severe data in the side of electric circuit. The wave resonance apparatus according to the frequency occurance transmits low-frequency's vibration ratio to the electric stimulating aspect. The wave-water is considered on the application of wave-resonance transcription on the water, and needs the comprehension of torsion-field level. The wave-stimulation of the bio-KI and the reception of the sensory-organ is observed the connection of the sensory-organ and it's corresponding wave. The informations recorded in the wave are distinguished patternly. And the several shaping waves transmit the informations each other through the resonnance. The wave theory is explained the LEE(理) as the wave-pattern and the KI(氣) as the revelation of the patterned-wave in the LEE-KI theory(理氣論), moreover the SHIN(神) as the information of the wave-pattern and the KI as the energy of the wave and the JEUNG(精) as the material of the wave in the JEUNG-KI-SHIN theory(精氣神論). In this point, the study on the wave-resonance of bio-KI is thought that it is significantly in the study method for oriental medicine. The sum of the wave makes the moving body and forms the universe. It means that the several wave patterns gather and form new field. The pattern is a kind of the information and the information is not materially. The information of wave-pattern is the arrangement and the combination of the material source.

Analysis of Ferromagnetic and Spin Wave Resonance Signals in CoFeB Thin Films (CoFeB 박막 재료에서 강자성 및 스핀파 공명 신호 분석)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.165-170
    • /
    • 2014
  • We analyzed the ferromagnetic and spin wave resonance signals measured in amorphous CoFeB thin films with different thickness. The ferromagnetic resonance field ($H_{FMR}$) was not depend on the thickness of CoFeB films, but the spin wave resonance field ($H_{SWR}$) was well fitted with the theoretical prediction depending on the thickness. The uniaxial anisotropy field of $H_k$ = 37 Oe was obtained from the angular dependent $H_{FMR}$ in CoFeB films. The $H_{SWR}$ showed same angular behaviors with $H_{FMR}$, however, the amplitude of spin wave resonance signals showed 5.7 times higher than that of ferromagnetic resonance signals in CoFeB film with t = 100 nm. The higher signals were due to the two reasons; one was the small damping for the spin wave propagation without degradation, the other was uniform magnetization for the ideal standing wave modes.

On-line Magnetic Resonance Quality Evaluation Sensor

  • Kim, Seong-Min;McCarthy, Michael J.;Chen, Pictiaw;Zion, Boaz
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.314-324
    • /
    • 1996
  • A high speed NMR quality evaluation sensor was designed , constructed and tested . The device consists of an NMR spectrometer coupled to a conveyor system. The conveyor was run at speeds ranging from 0 to 250 mm/s. Spectral of avocado fruits and one-dimensional magnetic resonance images of pickled olives were acquired while the samples were moving on a conveyor belt mounted through a 20Tesla NMR magnet with a 20 mm diameter surface coil and a 150 mm diameter imaging coil respectively. Fro a magnetic resonance spectrum analysis, motion through variations in the magnetic field tends to narrow spectral line width just like using sample rotation in high resolution NMR to narrow spectral line width. Spectrum analysis was used to detect the dry weight of avocado fruits using the ratio oil and water resonance peaks. Good correlations maximum r=0.970@ 50 mm/s and minimum r=0.894@250mm/s ) between oil and water resonance peak ratio and dry weight of avocados were observed at speeds ra ging from0 to 250mm/s. For the application of magnetic resonance imaging (MRI) method, the projections were used to distinguish between pitted and non-pitted olives . Effect of fruit position in the coil was tested and coil degree effects were noticed when projects were generated under dynamic conditions. Various belt speeds (up to 250mm/s) were tested and detection results were compared to static measurements. Higher classification errors were occurred at dynamic conditions compared to errors while olives were at rest.

  • PDF

The Changes of External Ear Resonance after Surgery for Repair of the Postauricular Meato-Mastoid Cutaneous Fistula (외이도-유양동-귀뒤바퀴피부 누공환자에서 수술 전, 후의 외이도 공명의 변화)

  • Kim, Sangjun;Kang, Myung Koo;Jeong, Sung Wook;Lee, Dong Kun
    • Journal of Clinical Otolaryngology Head and Neck Surgery
    • /
    • v.29 no.2
    • /
    • pp.235-239
    • /
    • 2018
  • Due to the structure with one end closed, the external ear resonance effect in which the high frequency is amplified can be generated, and the sound can be perceived well. The external ear resonance normally has a first peak and a second peak. On average, the first peak has a gain of 18.6 dB at 2620 Hz and the second peak has a gain of 18.2 dB at 4210 Hz. The resonance of the external auditory canal changes with the state of the tympanic membrane, the presence of the ventilation tube, and the structure (length, diameter, shape) of the external auditory canal. A patient with a postauricular meatomastoid cutaneous fistula was admitted to the hospital with a foreign body which is the molding of the hearing aid. After removal of the foreign body, the resonance of the external auditory canal was lost and the subjective sound cognitive ability decreased. In the case of postauricular meatomastoid cutaneous fistula, we confirmed the improvement of sound cognitive ability, the change of pure tone hearing threshold, and the change of the external ear resonance after reconstruction of the ear canal without middle ear reconstruction.