• Title/Summary/Keyword: and removal force

Search Result 386, Processing Time 0.023 seconds

Effect of Characteristics of Disk Surface on Particle Adhesion and Removal in a Hard Disk Drive (HDD 내 디스크 표면 특성이 미세입자의 부착 및 이탈에 미치는 영향)

  • 박희성;좌성훈;황정호
    • Tribology and Lubricants
    • /
    • v.16 no.6
    • /
    • pp.415-424
    • /
    • 2000
  • The use of magnetoresistive (MR) head requires much tighter control of particle contamination in a drive since loose particles on the disk surface will generate thermal asperities (TA). In this study, a spinoff test was performed to investigate the adhesion and removal capability of a particle to disk surface. Numerical simulation was also performed to investigate dominant factor of particle detachment and to support experimental results. It was shown that particles are detached from the disk surface by the moment derived from the centrifugal force and the drag force and that the centrifugal force and capillary force are the dominant force, which determines spin-off of a particle on the disk surface. Removal of particles smaller than several micrometers, which are the main source of TA generation, is extremely difficult since the adhesion forces exceed the centrifugal force. Lubricant types and manufacturing process also influence the particle removal. Lower bonding ratio and lower viscosity of the lubricant will help to increase the removal rate of the particles from the disk surface.

THE GROWTH OF RAT MANDIBLES FOLLOWING MANDIBULAR RETRACTIVE FORCE (백서 하악골 후방견인후의 하악골 성장에 관한 실험적 연구)

  • Kyung, Hee Moon
    • The korean journal of orthodontics
    • /
    • v.19 no.3
    • /
    • pp.15-33
    • /
    • 1989
  • The purpose of this study was to investigate changes of the mandible of a growing rat when they are subjected to a retractive force and those after removal of the retractive force. The experimental animals were Sprague-Dawley male rats of four weeks of age. A mandible was retracted with 50 grams of force on each side in the posterior and superior direction for 8 hours per day. The animals were sacrificed after 1 week, 2-week and 4-week force application, and after 4-week force application-4-week force removal period. The changes of rat mandibular growth following retractive force on the growing rat mandible were observed histologically and biometrically. The findings were as follows ; 1. Histologically, the thickness of the condylar cartilage was slightly reduced in the anterosuperior region with the retractive force. However, in the group of 4-week force application-4-week force removal, there was no significant difference in the thickness of the condylar cartilage. 2. There were no significant histological changes in the articular disk and glenoid fossa through the experimental period. 3. The length and anterior height of the mandible subjected to the retractive force were significantly smaller and greater than those of the control group. 4. There were no significant differences in the mandibular length between 4-week force application - 4-week force removal and the control group. 5. It was concluded that a mandibular retractive force produced inhibitory effects in the growth of the mandible, but that these effects were not sustained during mandibular growth in this experimental model.

  • PDF

INFLUENCE OF THE CLASP ARM LENGTH ON THE CHANGE OF RETENTIVE FORCE WITH REPEATED PLACEMENT AND REMOVAL (반복 장착 철거시 CLASP ARM의 길이가 유지력의 변화에 미치는 영향)

  • Ahn, Kwang-Ho;Dong, Jin-Keun;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.281-287
    • /
    • 1991
  • This study was designed to investigate the influence of the clasp arm length on the change of retentive force with repeated placement or removal. The author measured the retentive force of Akers clasp and I-bar clasp in the depth of undercut 0.5mm, 0.25mm, respectively, varying the length of clasp arm, that is, 10mm, 14mm, 17mm in Akers clasp and 16mm, 18mm, 20mm in I-bar clasp. The retentive force was measured just before the placement of removal, after 100 times repeated placement or removal, after 300 times repeated placement or removal. The obtained results were as follows : 1. The shorter the clasp arm, the greater retention in Akers clasp and I-bar clasp(p<0.05). 2. There was decreased retentive force of Akers clasp and I-bar clasp after 300 times repeated placement or removal(p.<0.005). 3. The decreasing rate of retentive force in Akers clasp with 10mm was higher than that with 17mm, after 300 times repeated placement or removal, but there was no statistica difference(p>0.05).

  • PDF

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

Effect of Metal Removal and Traction Force on Contact Fatigue Life (견인력과 접촉표면 제거가 접촉피로수명에 미치는 영향)

  • Seo Jung-Won;Hur Hun-Mu;Choi Jae-Boong;Kim Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.10 s.241
    • /
    • pp.1384-1391
    • /
    • 2005
  • Damage often occurs on the surface of railway wheels due to wheel-rail contact fatigue. It should be removed before reaching wheel failure, because wheel failure can cause derailment with loss of life and property. The increase or decrease of the contact fatigue lift by the metal removal of the contact surface were investigated by many researchers, but they have not considered initial residual stress and traction force. The railway wheel has the initial residual stress formed during the manufacturing process, and the residual stress is changed by thermal stress induced by braking. The traction force and residual stress are operated on wheels of locomotive and electric motor vehicle. In this study, the effect of metal removal depth on the contact fatigue life for a railway wheel has been evaluated by applying lolling contact fatigue test. The effect of the traction force and metal removal on the contact fatigue life has been estimated by finite element analysis. It has been found that the initial residual stress determines the amount of metal removal depth if the traction coefficient is less than 0.15. If the traction coefficient is greater than 0.2, however, the amount of metal removal depth is independent on the intial residual stress.

A Study on Frictional Characteristics and Polishing Result of SiO2 Slurry in CMP (CMP시 SiO2 슬러리의 마찰 특성과 연마결과에 관한 연구)

  • Lee Hyunseop;Park Boumyoung;Seo Heondeok;Jung Jaewoo;Jeong Sukhoon;Jeong Haedo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.7 s.238
    • /
    • pp.983-989
    • /
    • 2005
  • The effects of mechanical parameters on the characteristics of chemical mechanical polishing(CMP) can be directly evaluated by friction force. The piezoelectric quartz sensor for friction force measurement was installed, and friction force could be detected during CMP process. Furthermore, friction energy can be calculated by multiplying relative velocity by integration of the friction force throughout the polishing time. $SiO_2$ slurry for interlayer dielectric(ILD) CMP was used in this experiment to consider the relation of frictional characteristics and polishing results. From this experiment, it is proven that the friction energy is an essential factor of removal rate. Also, the friction force is related to removal amount per unit length(dH/ds) and friction energy has corelation to the removal rate(dH/dt) and process temporature. Moreover, within wafer non-unifornity(WIWNU) is related to coefficient of friction because of the mechanical moment equilibrium. Therefore, the prediction of polishing result would be possible by measuring friction force.

CMP Process Monitoring through Friction Force Measurement (마찰력 측정을 통한 CMP 공정의 모니터링)

  • 정해도;박범영;이현섭;김형재;서헌덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.622-625
    • /
    • 2004
  • The CMP monitoring system was newly developed by the aid of friction force measurement, resulting from installation of piezoelectric quartz sensor on R&D polisher. The correlation between friction and CMP results was investigated in terms of tribological aspects by using the monitoring system. Various friction signals were monitored and analyzed by the change of experimental conditions such as pressure, velocity, pad and slurry. First of all, the lubrication regimes were classified with Sommerfeld Number through measuring coefficient of friction in ILD CMP. And then, the removal mechanism of abrasives could be understood through the correlation with removal rate and coefficient of friction. Especially, the amount of material removal per unit sliding distance is directly proportional to the friction force. The uniformity of CMP performances was also deteriorated as coefficient of friction increased.

  • PDF

Cutting Force Analysis Under Chatter Condition with a Worn Tool (채터상황에서 마모된 공구가 받는 절삭력 해석)

  • 권원태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.292-301
    • /
    • 1994
  • The resultant cutting force during machining with a worn tool is viewed as a decomposition of the cutting force into a cutting force component related to chip removal from the workpiece and into a component dependent on the contact force between the tool flank's wear land and the workpiece. The shear line method, in which the cutting force is considered proportional to the length of the shear line, is used to calculate the cutting force component for the removal of the chip, while the elastic effect of the workmaterial on the tool is taken into consideration to analyze the effect of tool flank wear. The predicted resultant cutting force, expressed as the sum of both components, is compared to experimental data obtained during wave-on-wave cutting.

THE STUDY ON THE PERIODONTAL VASCULAR CHANGES OF RAT INCISORS FOLLOWING EXPERIMENTAL TOOTH MOVEMENT (실험적 치아이동시 백서 상악절치 치근막의 혈관 변화에 대한 연구)

  • Hyun, Seong-Wook;Suhr, CheonsG-Hoon
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.311-327
    • /
    • 1988
  • Vascular changes in the periodontal ligament of the rat incisors following application of experimental orthodontic forces were examined by the India ink perfusion method. 57 rats were used for this experiment. The rats were divided into experimental group (54 rats) and control group (3 rats). 54 experimental rats were divided into group I (27 rats) and group II (27 rats). The right and left upper incisors of group. I and group II rats were separated distally with forces of 20gm, 70gm respectively. The vascular changes of periodontal ligament were observed histologically by means of light microscope after 1, 2 and 3 days of tooth movement and 1,3,5,8,14, and 21 days after removal of orthodontic force. The results were as follows; 1. After one day of tooth movement, occlusion of blood vessels, hyalinization of periodontal ligament and resorption of alveolar bone adjacent to the alveolar crest on pressure side were observed. Above the tissue changes on the pressure side of group II were more severe than those of group I. Especially, septal bone of group II was separated after 2 days of tooth movement. 2. In tension zones, periodontal space was widened and periodontal fibers were orientated in the direction of puil. The blood vessels of periodontal ligament were distended. New bone deposition was seen along the inner surface of the alveolus after 2 days of tooth movement. 3. After 3 days of tooth movement, deposition of new bone was seen along the periosteal surface of alveolar bone on pressure side, progressing with increasing after removal of orthodontic force. Remodelling of the new bone was occurred 5 days after removal of orthodontic force. 4. 3 days after removal of orthodontic force, invasion of blood vessels into the marginal periodontal ligament on pressure side was observed clearly and the vessels below the epithelial attachment were increased. 5. After removal of orthodontic force, hyalinized structures disappeared concomittantly with an invasion of blood vessels from the neighboring periodontal ligament. 14 days after removal of orthodontic force, the vessels in the periodontal ligament of group I were finished the vascular rearrangement. 21 days after removal of orthodontic force, the vessels in the periodontal ligament of group II were finished the vascular rearrangement.

  • PDF

Incremental Analysis for Introduction of Advanced Robotic Laser Coating Removal System for Depainting of Fighter Jets (전투기 도장 제거용 로봇형 레이저 코팅 제거 시스템 도입 의사결정을 위한 증분분석)

  • Chang Young Lee;Jong Hun Park
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.8-20
    • /
    • 2022
  • The paint removal of fighter jets is just as important as the painting, because perfect paint removal ensures the quality of the exterior painting on the aircraft. However, the current conditions for paint removal work of the ROKAF's are poor. It is identified that the painting process currently implemented by the ROKAF is not only exposed to harmful compounds such as harmful dust and hexavalent chromium, but also consumes a lot of water. Thus, the introduction of advanced facility is considered. This study compares the fighter jets painting removal process currently applied by the Korean Air Force with the improved laser coating removal process of the US Air Force, and conducts an incremental analysis to perform economic analysis for the introduction of advanced facility. Four scenarios were envisioned on the premise of an increase in the number of fighters in the future, incremental analysis shows that laser coating removal method is advantageous in all scenarios. In addition, it is recommended that paint removal cycle keeps the current 12-year and the outsourcing amount to civilian depot is reduced.