• Title/Summary/Keyword: and hood

Search Result 395, Processing Time 0.021 seconds

Actual State and Characteristics of Indoor Noise Including Residents' Living in Apartment Units (아파트 단위주거 내부생활소음의 특성과 실태)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.1
    • /
    • pp.83-90
    • /
    • 2009
  • The present study is a preliminary research improving the dwelling quality of apartment house as a kind of multi-family housing. The purpose of the study is to find out the actual state on characteristics of indoor noise including residents' living in apartment units. The method was field survey consisted of field measurements on equivalent noise level, observation on noise type, and interview on residents' responses. Field survey were carried out in 20 occupied apartment units from January to March 2007. The results are as follows. 1) Averages of indoor noise levels including residents' living noise were measured as $43.9{\sim}62.2\;dB(A)_{Leq5min}$, the average of each house except one was higher than the permissible level, 45 dB(A). 2) The noise types observed were mostly residents' living noise and classified into 'water hammer', 'living equipment noise', 'noise by family', 'hood noise', 'kitchen noise' in own unit, 'walking and talking noise in stairs and corridors', 'noise by neighborhood house', 'noise by the upper story' in building, and outdoor noise. 3) The residents showed slightly non-positive responses at 'noise by the upper story', 'noise by neighborhood house', 'water hammer', and 'noise by family'. Therefore, it is required to plan for preventing deterioration of the dwelling quality by residents' living noise in own unit as well as by neighborhood houses.

Importance Analysis and Establishment of Community-Based Residential Environment Improvement Items (커뮤니티를 고려한 주거환경개선요소 설정 및 중요도 분석)

  • Kim, Hyun-Jin;Koo, Ja-Hoon;Won, Jai-Mu
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.127-134
    • /
    • 2009
  • This study initially analyzes the meaning of Community-Based Residential Environment Improvement. A residential environment improvement factor was determined through an analysis of the function, components, Planning techniques of the community, the evaluation criteria of the residential environment, and through relative literature documenting plans for the adjustment of urban and housing environments. In terms of the methodological approach, decisions were made based on the results of an expert focus-group-interview, a goodness-of-fit test, and by using the analytic network decision-making method from which the correlation among items can be considered. Results of this analysis show that the, order of importance of factors for a community-based residential environment is as follows: interactional character, cognitive character, and locational character. Furthermore, the most important aspect for each of these factors are the neighbor-hood relationship in terms of the interactional character, common consciousness for the cognitive character and place for locational character. The results of this study can be used by linking them with questionnaire items for basic resident research when a residential environment improvement project or a plan for the adjustment of urban and housing environments is planned.

Numerical simulation of impeller-volute interaction on a centrifugal turbomachinery (임펠러-볼류트 유동간섭이 원심형 터보기계의 성능에 미치는 영향에 관한 수치해석적 연구)

  • Lee, Jae-Doo;Joo, Won-Gu
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.170-178
    • /
    • 1999
  • In general, an impeller of centrifugal turbomachinery is designed at isolated condition without considering the presence of a volute, but when the impeller is operating with its volute, the performance of impeller can be different. This is largely caused by the interaction between the impeller and volute flow fields. The magnitude of distortion is increased as the operating point is away from the design point and, as a result, the interaction between the impeller and volute is stronger. In the present calculation, the flow through the impeller is simulated using coarse grids. The flow within the impeller and the volute is naturally unsteady, but the flow is assumed to be steady across the interface between the volute and impeller flow fields. Under the assumption of steady three-dimensional incompressible turbulent flow, the time averaged N-S equations involving standard k-$\epsilon$ turbulent model was solved by the F.V.M. The calculation results are compared with the experimental results obtained for an industrial fan by Sakai etc. and the Hood agreement is demonstrated. And the effects of the impeller-volute interaction are studied.

  • PDF

A study of Flame Arrestor's Spring Structural Analysis (폭연방지기 스프링의 구조해석에 관한 연구)

  • Pham, Minh-Ngoc;Kim, Bu-Gi;Kim, Jun-Ho;Choi, Min-Seon;Yang, Chang-Jo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2017.11a
    • /
    • pp.69-69
    • /
    • 2017
  • Flame arrestor as end of line flame arrester for endurance burning prevents a light-back at deflagration and stabilized burning (during and after endurance burning) of potentially explosive vapor-air and gas-air mixtures at the end of vent pipes. In a flame arrestor, spring is an important part. The spring load as well as the spring's elasticity determine when the hood is opened. In addition, the spring have to work in high temperature condition due to gas burning. Therefore, it is necessary to analyze mechanical load and elasticity of spring when gas is burned. Based on the dynamic calculation on working process of a specific flame arrestor, analysis of spring is taken. A three dimensional model for spring burned in flame arrestor by using CFD simulation. Results of the CFD analysis are input in FEM simulation to analyze structure of the spring. The simulation results can predict and estimate the spring's load and elasticity at variation of the spring's deflection. Moreover, the obtained result can provide makers with references to optimize design of spring as well as flame arrestor.

  • PDF

Prediction of the ventilation performance in a kitchen with various locations of gas range and window (가스렌지와 창문위치에 따른 주방 배기성능 예측)

  • 김경환;이재헌;박명식;이대우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

3-D FEM Analysis of Forming Processes of Planar Anisotropic Sheet Metal (평면이방성 박판성형공정의 3차원 유한요소해석)

  • 이승열;금영탁;박진무
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2113-2122
    • /
    • 1994
  • The 3-D FEM analysis for simulating the stamping operation of planar anisotropic sheet metals with arbitrarily-shaped tools is introduced. An implicit, incremental, updated Lagrangian formulation with a rigid-viscoplastic constitutive equation is employed. Contact and friction are considered through the mesh-normal, which compatibly describes arbitrary tool surfaces and FEM meshes without depending on the explicit spatial derivatives of tool surfaces. The consistent full set of governing relations, comprising equilibrium equation and mesh-normal geometric constraints, is appropriately linearized. The linear triangular elements are used for depicting the formed sheet, based on membrane approximation. Barlat's non-quadratic anisotropic yield criterion(strain-rate potential) is employed, whose in-plane anisotropic properties are taken into account with anisotropic coefficients and non-quadratic function parameter. The planar anisotropic finite element formulation is tested with the numerical simulations of the stamping of an automotive hood inner panel and the drawing of a hemispherical punch. The in-plane anisotropic effects on the formability of both mild steel and aluminum alloy sheet metals are examined.

A Study on the Protection Functionality of Supermodern Fashion (슈퍼모던 패션의 보호기능에 관한 연구)

  • Kim, Wan-Joo;Lee, Keum-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.8
    • /
    • pp.1264-1273
    • /
    • 2008
  • The purpose of this study is to analyze protection functionality of supermodern fashion which is shown by responding to supermodern environment, where non-spaces increases in the 21st modern city. The theoretical background is drawn for supermodern environment theory. For the study, he researcher used existing study and specialized book and analyzed photograph materials by selecting them in specialized fashion book, internet site and designer's collection. The works from 1995 S/S collection to 2008 S/S collection are analyzed. The result of this study is as follow. First, supermodern design is adopting the shape of high-functional element, electronic device, protective device to protect wearer in non-space. Second, in order to mentally protect individual anonymous leadership of interaction is granted by adopting hood, veil or mask. Third, supermodern design is creating independent and user-based space by shape transformation in change of urban environment. Fourth, in order to protect wearer through camouflage or concealment, camouflage pattern or neutral color are used.

Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF

Correlation Analysis for deriving Control Parameters in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트 제어인자 도출을 위한 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong;Baek, Chang-In
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.895-900
    • /
    • 2008
  • It is the objective of the present study to conduct correlation analysis for deriving control parameters in vertical shafts using the results obtain by the design of experiments in the preceding research. The control parameters are categorized into objective parameters, derived parameters, condition parameters, operation parameters, and sensing parameters. The maximum pressure in the shaft should be sufficiently small in order to maintain exhaust hood performance. The pressure variations between floors should also be minimized in order to maintain uniform exhaust performance between floors and to save energy for excessive pressure drop in the shaft. The standard deviation based on -4Pa is proposed as an objective parameter to control pressure in shafts. The correlation equation has been obtained between the standard deviation and the sensing parameters of outdoor temperature and the pressure at the top of the shaft.

  • PDF

The Characteristics of the Noise of Electric Home Appliances (가전제품의 소음 특성)

  • Gu, Jin-Hoi;Kang, Dae-Joon;Lee, J.W.;Kim, T.S.;Kwon, H.J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.332-339
    • /
    • 2007
  • As the economy has grown and the main industry in Korea has been changed from secondary industry to tertiary industry, the importance of indoor environment has been a matter of common concern, in which one of the main concerns is to improve the indoor acoustic conditions. However, even though this is required more than before, there are no measures to protect the human being from the noise of electric home appliances. This is owing to the absence of the data about sound power level of electric home appliances. So, we investigate the sound power level of them and analyze the acoustical characteristics of each one. First, we tried to investigate the sound power measurement method of each electric home appliance. After it we test the sound power level of them. From the survey, we can know that the vacuum cleaner is the most noisy electric home appliance, and the refrigerator is the least noisy one. The noise of a range hood is distributed over a wide range frequency. Lastly, we intented to propose the proper method measuring sound power level on each electric home appliance.

  • PDF