• 제목/요약/키워드: and hood

검색결과 395건 처리시간 0.026초

조선조여인의 쓰게에 관한 연구 (A study on the Women's Veil of Yi Dynasty)

  • 정광희
    • 대한가정학회지
    • /
    • 제20권4호
    • /
    • pp.13-22
    • /
    • 1982
  • While the women of the Korea Dynasty wore hat(笠子) and Mongsu(蒙首) on top of it when going out, the Yi Dynasty, due to more strict Contucian ethics and isolated way of life, had seen the development of the covering clothes, rather veil, for avoiding the opposite sex with diversity and both men and women began wearing PHO(coat), a Korean topcoat over the head and thurs called Changots, but originally PHO for men was named Changyi a men's outer coat. Neuwul(羅兀), like Mongsu(蒙首) of Korea Dynasty was a thin black hood worn on top of the Wowllip or a kind of skirt draped over the head and the latter was called Changots, very similar to Sgaechima, a kind of long hood formally worn by women. Meanwhile, local women wore a long veil with no arm sleeves dubbed Cheunyi(薦衣) But since western civilization and culture landed on Korea around the end of the 19th century, the women's social status has been raised to almost the same level with men and the way of life has changed towards openness, in which men and women have almost daily contact with one another, so these days we can hardly find such veil style covering clothes around us.

  • PDF

렌지후드의 성능개선을 위한 시로코 팬 주위의 유동해석 (PERFORMANCE IMPROVEMENT OF A RANGE HOOD SIROCCO FAN BY CFD FLOW ANALYSIS)

  • 한병윤;박진우;이명수;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.159-165
    • /
    • 2008
  • A sirocco fan is widely used for discharging pollutants of a kitchen space since it is able to generate a relatively high air flow rate considering its small size and makes less noise than a axial fan or a centrifugal fan. However, it has a problem because its efficiency is low, and power consumption is larger. Performance of a sirocco fan is influenced by various factors such as number of the fan blades, diameter of the fan, geometry of the fan, geometry of its housing, revolution frequency, static pressure condition, and etc. This research investigated the effect on the performance of geometry of the housing. For CFD analysis, we used a commercial code, SC/Tetra, and used a sliding mesh method to give the same condition as an actual state. Verification of the CFD results is done by comparison of experimental data and numerical one about the suction flow rate, and it is confirmed that two results are well consistent. After we changed the shape of housing according to Archimedes' screw, we observed that suction efficiency is improved by 10.7% maximum.

  • PDF

유조선 화물취급구역내 동력환기특성에 관한 연구 (A Study on Mechanical Ventilation Characteristics in Cargo Handling Area of Tanker)

  • 조대환
    • 해양환경안전학회지
    • /
    • 제7권1호
    • /
    • pp.15-23
    • /
    • 2001
  • In regulation of IGC code 12.1 mechanical ventilation should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable or toxic vapours and ensure a safe working environment, but in no case should the ventilation system have a capacity of less than 30 changes of air per hour baed upon the total volume of the space. In this study, a scaled mode chamber was constructed to investigate the ventilation characteristics and stagnation area in the hood room of LNG carrier and pump room in tanker. An experimental study was performed on the model by using visualization equipment with a laser apparatus and an image intensifier CCD camera. Twelve different kinds of measuring areas were selected as the experimental condition. Instant simultaneous velocity vectors in the whole fields were measured by a 2-D PIV system A three-dimensional numerical simulation was also carried out for three different Reynolds numbers. Then the CFD predictions were discussed with the experimental results. The results show the spiral L-shape flow that moves from the opening on the left wall diagonally to the upper right part dominates the ventilation structure. The stationary area of hood room in the velcoity distributions was located in the upper left stern part.

  • PDF

오트 쿠튀르 컬렉션에 나타난 헤드드레스 디자인 -2010 S/S~2015 S/S 컬렉션을 중심으로- (Headdress Designs appearing in Haute Couture Collection -Focused on 2010 S/S~2015 S/S-)

  • 최진영;김지영
    • 패션비즈니스
    • /
    • 제20권2호
    • /
    • pp.59-77
    • /
    • 2016
  • The purpose of this study is to use data from studies of headdresses which might be helpful for creating new fashion styles. Headdresses in 2010 S/S-2015 S/S Paris haute couture collections were analyzed in the following categories: years, season, brand, type, color, material, and image. The types of headdresses were categorized as hat, hood, decorative or complex types. The hat type was elegant with a modern style, and coexisted with an exaggerated avant garde style. The hood type wrapped around the head with many examples having a distinctive sculpture on top of the knot. The decorative type varied dramatically in form and materials. The complex type was a blend of all the other types with the designer's individuality being outstanding. The characteristics of headdresses were revealed first, as an enlargement of the materials category, second, as an expression of dramatic forms, and third, as complete coordination of the creative fashion image. The headdresses illustrate the designer's creativity in producing a variety of images. Henceforth they will be important as fashion items and independent designs in fashion styling.

바닥의 위치가 Vortex Vent의 배기성능에 미치는 영향 (Effect of the Floor on the Ventilation Performance of the Vortex Vent)

  • 이진원;임영복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.154-158
    • /
    • 2009
  • The vortex ventilation system (VV) which uses a rotating finned swirler installed coaxially with the exhaust duct is a very effective local ventilator. VV can enhance the capture depth by a factor of 3-5 compared to the conventional exhaust hood, in the absence of any solid walls nearby. In real situations there may exist ceiling, side wall and floor, all of which can affect the flow field and suction performance by way of the no-slip condition on the walls. 3D CFD simulation was performed in order to see the effect of the floor on the capture performance of the VV. The presence of floor reduced suction flow velocity, and increased the critical rotational speed which is the rotational speed required for stable vortex formation. Flow velocity profile along the axis could be well approximated by a universal functional form when the distance from the exhaust inlet is non-dimensionalized by the distance to the floor. Capture depth, define by the distance from the exhaust inlet to a point of velocity decreased to 10% of that at the inlet, is reduced by about 10% when the floor distance is 6 times the exhaust hood diameter.

  • PDF

비대칭 입출구를 갖는 장방형공간의 유동특성 (Flow Characteristics of Rectangular Space with Asymmetric Inlet and Outlet)

  • 이철재
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.261-266
    • /
    • 2006
  • 이 연구에서는 실제선박의 후드룸을 1/15로 축소한 비대칭 입출구를 갖는 장방형 모델을 대상으로 가시화 실험을 수행하고 내부의 유동 특성을 고찰하고자 하였다. 속도장의 계측은 CACTUS'2000을 이용한 2차원 PIV기법으로 하였으며 4개의 계측영역을 설정하여 계측한 결과 유동장의 환기구조를 지배하는 흐름은 유동장의 좌측 벽면의 흡기구로부터 대각방향의 우측상부로 흐르는 나선형의 'L'형 유동이었다. 또한 주 흐름의 영향으로 유동장의 중앙부분에 강제와류형태의 재순환 흐름이 존재하였다.

  • PDF

급식시설 . 설비 표면의 위생상태 및 계절별 미생물 균수의 변화 (Seasonal Changes of Microbiological Counts and Sanitation State on the Surface of Foodservice Facilities and Utilities)

  • 김지현;김이선;한지숙
    • 한국식품영양과학회지
    • /
    • 제33권10호
    • /
    • pp.1653-1660
    • /
    • 2004
  • 부산시내 초등학교 5곳을 방문하여 현 급식소에서 보유하고 있는 급식시설$.$설비에 대한HACCP 적용시 중점관리점을 파악하기 위하여 위생평가를 실시하였다. 학교 급식 시설$.$설비는 학교급식소에서 사용하고 있는 천장, 벽, 바닥, 트렌치, 그리스 트랩, 후드, 방충망, 덤웨이터 등 총 8곳으로 분류하여 총균수, 대장균군수 측정을 통해 위생상태를 확인하였다. 급식시설$.$설비 표면의 위생상태를 검사한 결과 천장, 벽을 제외한 나머지에서 $10^4$$10^{6}$ CFU/100 $\textrm{cm}^2$의 세균이 검출되어 여전히 학교급식소의 위생수준이 낮은 것으로 파악되었고 특히, 그리스 트랩의 경우가 가장 위생상태가 불량한 것으로 나타났다. 대장균군수의 경우는 천장을 제외한 나머지 장소에서 $10^2$$10^4$ CFU/100 $\textrm{cm}^2$의 세균이 검출되었고 그리스 트랩에서 가장 높은 수의 세균과 대장균이 발견되어 특별히 관리 해야 되는 부분으로 확인되었다. 또한 학교급식 시설$.$설비의 하절기 및 동절기의 위생상태를 알아보고 중점 관리 점을 제시하기 위하여 급식 후 세 척 및 소독을 실시한 다음 시간 및 요일의 경과에 따른 오염도를 측정한 결과, 하절기에는 매일 소독을 실시해야 하는 바닥, 트렌치, 그리스 트랩, 덤웨이터의 경우는 급식 전에 소독을 실시한 후 급식을 시작해야 하는 것으로 나타났고, 주 1회 소독을 실시 하는 벽, 후드, 방충망은 주 3회 이상으로 소독횟수를 늘려 실시해야 하는 것으로 나타났다. 동절기에는 바닥, 트렌치, 덤웨이터의 경우는 현재와 마찬가지로 급식 후에 소독을 실시하여야 하는 것으로 나타났고 그리스 트랩의 경우는 급식 전에 실시한 후 급식을 시작해야 하는 것으로 나타났다. 벽, 후드, 방충망은 주 2회 이상으로 소독횟수를 늘려 실시해야 하는 것으로 나타났다.