• Title/Summary/Keyword: and hood

Search Result 395, Processing Time 0.024 seconds

A Numerical Study on Performance Improvement of Canopy Hood in Melting Process (용해공정의 캐노피 후드 성능 개선에 관한 수치 해석적 연구)

  • Jung, Yu-Jin;Shon, Byung-Hyun;Lee, Sang-Man;Jung, Jong-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1519-1526
    • /
    • 2013
  • This study reviewed the capturing performance of a canopy hood used in some melting processes of a casting manufacturing factory through a site survey. In addition, this study compared and evaluated the flow field and pressure field for the plans to enhance the hazardous air pollutants collection capacity by using CFD model. The case-2(flange attached + double hood) can be improved in terms of collection performance, but is expected to increase in hood static pressure by about 70% more than the existing structure, so it was shown that its site applicability is not good. It is judged that the shape of case-3(flange attached + double cone attached) is most suitable to improve the suction efficiency. This is because a double cone is installed at the center of the opening to concentrate the flow rate on the edge of the hood and control the hume rising to the center of the hood without a static pressure rise via the slope of the cone.

Characteristics of High-Speed Railway Tunnel Entry Compression Wave (고속철도 터널입구에서 형성되는 압축파의 특성에 관한 연구)

  • Kim, Heuy-Dong;Kim, Tae-Ho;Lee, Jong-Su;Kim, Dong-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.234-242
    • /
    • 1999
  • Flow phenomena such as the pressure transients Inside a high-speed railway tunnel and the Impulsive waves at the exit of the tunnel are closely associated with the characteristics of the entry compression wave, which is generated by a train entering the tunnel. Tunnel entrance hood may be an effective means for alleviating the Impulsive waves and pressure transients. The objective of the current work is to explore the effects of the train nose shape and the entrance hood on the characteristics of the entry compression wave. Numerical calculations using the method of characteristics were applied to one-dimensional, unsteady, compressible flow field with respect to high-speed railway/tunnel systems. Two types of the entrance hoods and various train nose shapes were employed to reveal their influences on the entry compression wave for a wide range of train speeds. The results showed that the entry compression wave length increases as the train nose becomes longer and the train speed becomes lower. The entry compression wave length in the tunnel with hood becomes longer than that of no hood. Maximum pressure gradient in the compression wavefront reduces by the entrance hood. The results of the current work provide useful data for the design of tunnel entrance hood.

Experimental Study on the Slit Cover Hood for Reducing the Micro Pressure Waves in High-speed Train-tunnel Interfaces (고속철도에서 슬릿커버후드의 터널 미기압파 저감성능에 관한 연구(II))

  • Kim, Dong-Hyeon;Shin, Min-Ho;Han, Myeong Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.3
    • /
    • pp.3-11
    • /
    • 2000
  • Purpose of this paper is to investigate the hood configuration at a tunnel entrance to reduce the micro pressure wave that is generated according to train speed. Two configurations were examined for the tunnel of 0.5 km in length. The experimental results show that a slit cover hood installed at the entrance of the tunnel reduces the maximum micro pressure wave by 41.2%, and the configuration with a slit cover hood installed at the entrance and the $45^{\circ}$ slanted portal at the exit of the tunnel suppress the pressure wave by 47.7%.

  • PDF

Topology Optimization of a Vehicle's Hood Considering Static Stiffness (자동차 후드의 정강성을 고려한 위상 최적화)

  • Han, Seog-Young;Choi, Sang-Hyuk;Park, Jae-Yong;Hwang, Joon-Seong;Kim, Min-Sue
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.1
    • /
    • pp.69-74
    • /
    • 2007
  • Topology optimization of the inner reinforcement for a vehicle's hood has been performed by evolutionary structural optimization(ESO) using a smoothing scheme. The purpose of this study is to obtain optimal topology of the inner reinforcement for a vehicle's hood considering the static stiffness of bending and torsion simultaneously. To do this, the multiobjective optimization technique was implemented. Optimal topologies were obtained by the ESO method. From several combinations of weighting factors, a Pareto-optimal solution was obtained. Also, a smoothing scheme was implemented to suppress the checkerboard pattern in the procedure of topology optimization. It is concluded that ESO method with a smoothing scheme is effectively applied to topology optimization of the inner reinforcement of a vehicle's hood considering the static stiffness of bending and torsion.

Experimental Study on the Slit Cover Hood for Reducing the Micro Pressure Waves in High-Speed Train-Tunnel Interfaces (고속철도에서 슬릿커버 완충공의 터널 미기압파 저감성능)

  • Kim, Dong-Hyeon;Min, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.758-765
    • /
    • 2001
  • Purpose of the present is to investigate the food configuration at a tunnel entrance for reducing the micro pressure wave that is generated according to train speed. Two configurations were examined for tunnel of 0.5 km length. The experimental results show that a slit cover hood installed at the entrance of the tunnel reduces the maximum micro pressure wave by 41.2%, and a configuration with a slit cover hood installed at the entrance and a 45$^{\circ}$slanted portal at the exit of the tunnel suppresses it by 47.7%.

Noise Reduction of Range Hood in Kitchen Ventilation System (주방 환기 시스템에서 렌지 후드의 소음 감소 방안)

  • 최영석;김철호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.848-851
    • /
    • 2004
  • This paper studied a method for minimizing the noise level emitted from range hoods. Range hoods were used for discharging various hazardous materials generated during household cooking to the outdoors, thus preventing them from being diffused through rooms in the house since they are the main cause of air pollution within dwellings. This study assumed that static pressure was not applied at the discharge outlet of the range hood. As such, the range hood was installed on the wall without the use of a connecting duct or other connectors attached to its discharge outlet. The vibration having the greatest influence on the noise level was determined by measuring the vibration at the front side of the hood where the acoustic omission was at its maximum. A method was then proposed to reduce the noise by simply suppressing the vibration at the vibrating part.

  • PDF

Experimental study on the alleviation of micro-pressure waves radiated from the tunnel exit with the slit hoods on the high-speed train operations of 300km/h (300km/h급 고속철도의 터널 미기압파 저감을 위한 슬릿후드의 실험적 연구)

  • Kim, Dong-Hyeon;Min, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.619-624
    • /
    • 2000
  • The purpose of present study is to investigate for reducing micro pressure waves generated according to train speeds $(240km/h{\sim}380km/h)$ through tunnels with countermeasures as followings; the hood configuration in tunnel entrance. We developed hoods for tunnel of 0.5 km length in the condition of tunnel cross-section area of $107m^2$ on the slab track. According to the results the maximum micro-pressure wave is reduced by 41.2% for the slit hood installed at the entrance of the tunnel and reduced by 47.7% for the slit hood installed at the entrance of the tunnel and the $45^{\circ}$ slanted portal at the exit of the tunnel

  • PDF

Noise Reduction of a Range Hood using Micro-Perforated Panel (미세 다공판을 이용한 레인지 후드의 소음저감)

  • Kim, Deok-Han;Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1205-1208
    • /
    • 2006
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which rumbling noise is generated. Though the rumbling noise has low noise level. this noise makes most of the users nervous due to the its low frequency characteristics. For the purpose of noise reduction, in this study, a micro-perforated panel system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level emitted from the range hood is decreased over 2dB(A) in all frequency regions due to the effect of noise reduction by micro-perforated panel system.

  • PDF

A Research on the Noise Reduction of Range Hood for Household (가정용 레인지 후드의 소음저감에 관한 연구)

  • Hong, Byung-Kuk;Song, Hwa-Young;Lee, Dong-Hoon;Lee, Chang-Kun;Kim, Dong-Yun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.449-452
    • /
    • 2005
  • This paper introduces a study for the noise reduction of a range hood for household. Generally, range hoods have a built-in sirocco fan from which squawky noises are generated. Though the squawky noises have low noise level, these kinds of noises make most of the users nervous. For the purpose of noise reduction, in this study, a perforated plate system is installed in the fan housing of range hood. From the experimental results, it is confirmed that the noise level omitted front the range hood is decreased above 2dB(A) in all frequency regions due to the effect of noise reduction by perforated panel system.

  • PDF

A Study on the Reduction of Entry Loss by Inner Structure in Square Hood in Industrial Ventilation System (산업환기시설에서 사각형 후드의 내부 설치에 의한 유입손실 감소에 관한 연구)

  • Bae, Hyun-Joo;Yang, Won-Ho;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.27-34
    • /
    • 2003
  • An objective of local exhaust hood design is to design the hood to operate as efficiently as possible. The greatest loss normally occurs at the entrance to the duct, due to the vena contracta in the throat of the duct. This can be accomplished by minimizing the loss that results from the vena contracta. There have been little studied to be cost-effective approach as installing simple instrument inside the throat of the hood. The aims of this paper were to minimize entry loss using inner square, and to measure the effect of inner square when installed inside hood throat. The results of this study were as follows; First, the magnitude of vena contracta could be considered as the difference between direct measured velocity and calculated velocity, which is from Bernoulli theory. In circle hood, calculated velocity and direct measured velocity were 10.7m/sec and 10.3n/sec, respectively. And the calculated velocity and direct measured velocity in square hood were 7.7m./sec and 6.5m/sec, respectively. Second, effect of inner square by width was carried out. The widths of inner square were L/1(18cm), L/2(9cm), L/3(6cm) and L/6(3cm). In case inner square was installed with 3cm width, the entry of coefficient was 0.93, comparing with 0.85 of entry of coefficient of general hood. Third, effect of inner square by distance from hood inside surface to inner square was carried out. The distances were L/3(6cm), L/6(3cm), L/9(2cm) and L/l8(1cm). In case the distance was 3cm the best efficiency was shown (Ce= 0.93). Fourth, effect of inner square by location from hood entry to duct inside was carried out. The locations of inner square were entry(0cm), L/6(3cm), L/3(6cm), L/2(9cm) and L/l(12cm). In case the location was 0cm, 3cm and 6cm the entry of coefficients were 0.93, 0.92 and 0.90, respectively.