• Title/Summary/Keyword: and heart

검색결과 10,821건 처리시간 0.039초

Design of a Heart Rate Measurement System Using a Web Camera

  • Jang, Seung-Ju
    • International journal of advanced smart convergence
    • /
    • 제11권3호
    • /
    • pp.179-186
    • /
    • 2022
  • In this paper, we design a heart rate measurement system using a web camera. In order to measure the heart rate, face image information is acquired and classified. The face image data is collected from web camera. The heart rate is measured using the collected face image data. We design a function to measure heart rate using input of face information using a web camera in non-contact manner. We design a function that reads face information and estimates heart rate by analyzing face color. An experiment was performed to compare the non-contact heart rate with the actual measured heart rate. The heart rate measurement system using a web camera proposed in this paper is a technology that can be used in various fields. It will be used in sports fields that require heart rate measurement at a low cost.

한국형 인공심장(AnyHeart)의 임상경험 (A Clinical Experience of Korean Artificial Heart(AnyHeart))

  • 선경;손호성;정재승;정봉규;이성호;신재승;김광택;이혜원;민병구;김형묵
    • Journal of Chest Surgery
    • /
    • 제35권7호
    • /
    • pp.548-552
    • /
    • 2002
  • 한국형 인공심장(AnyHeart)은 single moving actuator mechanism을 이용한 일체형 및 이식형 양심실 박동펌프이다. 저자 등은 양심 부전증에 의한 말기 심장병 환자에서 구난의료 차원으로 시도된 한국형 인공심장 (AnyHeart) 이식 1례를 경험하였기에 그 결과를 보고한다.

Systematic test on the effectiveness of MEMS nano-sensing technology in monitoring heart rate of Wushu exercise

  • Shuo Guan
    • Advances in nano research
    • /
    • 제15권2호
    • /
    • pp.155-163
    • /
    • 2023
  • Exercise is beneficial to the body in some ways. It is vital for people who have heart problems to perform exercise according to their condition. This paper describes how an Android platform can provide early warnings of fatigue during wushu exercise using Photoplethysmography (PPG) signals. Using the data from a micro-electro-mechanical system (MEMS) gyroscope to detect heart rate, this study contributes an algorithm to determine a user's fatigue during wushu exercise. It sends vibration messages to the user's smartphone device when the heart rate exceeds the limit or is too fast during exercise. The heart rate monitoring system in the app records heart rate data in real-time while exercising. A simple pulse sensor and Android app can be used to monitor heart rate. This plug-in sensor measures heart rate based on photoplethysmography (PPG) signals during exercise. Pulse sensors can be easily inserted into the fingertip of the user. An embedded microcontroller detects the heart rate by connecting a pulse sensor transmitted via Bluetooth to the smartphone. In order to measure the impact of physical activity on heart rate, Wushu System tests are conducted using various factors, such as age, exercise speed, and duration. During testing, the Android app was found to detect heart rate with an accuracy of 95.3% and to warn the user when their heart rate rises to an abnormal level.

희상심(喜傷心)의 병기(病機)에 대한 고찰 (A Study on the Mechanism upon Joy Impairs the Heart)

  • 안진희
    • 대한한의학원전학회지
    • /
    • 제32권3호
    • /
    • pp.73-83
    • /
    • 2019
  • Objectives : The purpose of this paper is to investigate the mechanism of 'Joy impairs the Heart'. Methods : "Huangdineijing" was searched in relation to 'Joy' and 'Heart', then Joy was divided into physiological and pathological joy. After examination of the similarities and differences between the two, the mechanism of 'Joy impairs the Heart' was drawn out. Results : 1. Excessive Joy not only relaxes Qi(氣), but also disperses Shen(神). 2. Impairment of Heart damages heart locally and Impairment of Yang not only damages Qi or Shen focally, but also damages Yang of the whole body and the degree of damage is thought to be more extensive than "Joy impairs the Heart". 3. "Too much joy and pleasure can cause the Shen(神) to scatter and not remain stored." not only relaxes Qi, but also disperses Shen(神), and the degree of damage is less than "Sudden joy damages Yang". Conclusions : Excessive or Sudden Joy impairs the Heart by disturbing Heart's property of maintaining Taiyang by scattering Shen(神) or not maintaining high Yang density. Forced expression of Joy impairs the Heart by relaxing and stagnating Qi.

Cystatin C for managing diuretic-induced kidney dysfunction in MMVD dogs

  • Donghyun Han;Jae Hyeon Cho;Chung Hui Kim
    • 한국동물위생학회지
    • /
    • 제46권3호
    • /
    • pp.181-192
    • /
    • 2023
  • Cystatin C, a low-molecular-weight protein synthesized by cells, is being explored as a valuable biomarker for assessing renal function in veterinary medicine. Although the relationship between cystatin C and heart disease remains unclear, some studies suggest a possible association. This retrospective case-control study aimed to investigate the role of cystatin C as a biomarker for heart disease and its correlation with diuretic use in veterinary clinical practice. A total of 39 dogs were included in this study, comprising 9 control dogs without a predisposition to heart disease and 30 dogs in the study group diagnosed with heart disease. Among the 30 dogs with heart disease, 18 exhibited symptoms indicative of heart failure. Results showed significantly higher cystatin C levels in the heart disease group compared to the control group (P<0.05). However, no significant differences were observed among different stages of heart disease severity in the control group. Furthermore, cystatin-C showed statistically positive correlations with BUN (r=0.478, P<0.01), creatinine (r=0.506, P<0.01), and furosemide (r=0.338, P<0.05). Diuretics are essential for managing congestive heart failure, and the observed associations between cystatin C and furosemide suggest potential impacts of diuretic use on renal function in dogs with heart failure. Monitoring renal function markers, such as cystatin C, can aid in predicting and managing potential renal complications, ultimately improving the overall health and quality of life of dogs with heart disease.

Robot-Assisted Repair of Atrial Septal Defect: A Comparison of Beating and Non-Beating Heart Surgery

  • Yun, Taeyoung;Kim, Hakju;Sohn, Bongyeon;Chang, Hyoung Woo;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • 제55권1호
    • /
    • pp.55-60
    • /
    • 2022
  • Background: Robot-assisted repair of atrial septal defect (ASD) can be performed under either beating-heart or non-beating-heart conditions. However, the risk of cerebral air embolism (i.e., stroke) is a concern in the beating-heart approach. This study aimed to compare the outcomes of beating- and non-beating-heart approaches in robot-assisted ASD repair. Methods: From 2010 to 2019, a total of 45 patients (mean age, 43.4±14.6 years; range, 19-79 years) underwent ASD repair using the da Vinci robotic surgical system. Twenty-seven of these cases were performed on a beating heart (beating-heart group, n=27) and the other cases were performed on an arrested or fibrillating heart (non-beating-heart group, n=18). Cardiopulmonary bypass (CPB) was achieved via cannulation of the femoral vessels and the right internal jugular vein in all patients. Results: Complete ASD closure was verified using intraoperative transesophageal echocardiography in all patients. Conversion to open surgery was not performed in any cases, and there were no major complications. All patients recovered from anesthesia without any immediate postoperative neurologic symptoms. In a subgroup analysis of isolated ASD patch repair (beating-heart group: n=22 vs. non-beating-heart group: n=5), the operation time and CPB time were shorter in the beating-heart group (234±38 vs. 253±29 minutes, p=0.133 and 113±28 vs. 143±29 minutes, p=0.034, respectively). Conclusion: Robot-assisted ASD repair can be safely performed with the beating-heart approach. No additional risk in terms of cerebral embolism was found in the beating-heart group.

송아지에 이식한 공기구동형 인공심장의 혈역학적 연구 (Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves)

  • 박표원
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

개심술 152예의 임강적 고찰 (Clinical Experience of Open Heart Surgery - Report of 152 Cases -)

  • 임승균;김동관
    • Journal of Chest Surgery
    • /
    • 제25권2호
    • /
    • pp.167-175
    • /
    • 1992
  • During a 4 year period from 1987 to 1991, 152 patients underwent open heart surgery for congenital heart disease and acquired heart disease. Over all operative mortality was 6.6%. There were 76 congenital anomalies consisting of 73 acyanotic and 3 cyanotic and 76 acquired heart disease. The age distribution of 152 cases was 3 months to 62 years. Mean age was 13.0 years in congenital heart anomalies and 38.9 years in acquired heart disease patients.

  • PDF

주파수 평탄도에 기반한 심잡음 검출 알고리즘 (Heart Murmur Detection Algorithm based on Spectral Flatness)

  • 이윤정;이기현;나승대;성기웅;조진호;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제19권3호
    • /
    • pp.557-566
    • /
    • 2016
  • Heart sounds generated by the beating heart and blood flow reflect the turbulence created when the heart valves snap shut. Cardiac diagnosis is typically started by an auscultation using a stethoscope, from which a medical doctor, depending on his hearing capabilities and training, listens and interprets the acoustic signal. This method of diagnostic is uncertain, mostly due to the fact that human ear loses the acoustic frequency sensitivity through the years. Even though an auscultation has some weaknesses like uncertainty, it is considered as a primary tool due to its simplicity. In this paper, heart murmur detection algorithm is proposed using time and frequency characteristics of heart sound. The propose heart murmur detection method adapted conventional primary heart sound detection method in time domain and modified spectral flatness method in frequency domain for detecting heart murmurs. From experimental results, it is confirmed that the proposed algorithm detect the heart murmurs efficiently.

자세 조절 운동이 심장이식환자의 심박수 상승지연에 미치는 영향 -단일사례연구- (Effects of Postural Control Exercise on the Delayed Heart Rate Increase in Heart Transplant Patients -A Case Study-)

  • 최수홍;이상열
    • PNF and Movement
    • /
    • 제16권2호
    • /
    • pp.161-168
    • /
    • 2018
  • Purpose: This study aimed to investigate the effects of postural control exercise on the delayed heart rate increase in heart transplant patients. Methods: The subject was a female heart transplant recipient who had a delayed increase in heart rate during exercise. The intensity of exercise was performed at MBorg level 4. The A-B-A' and A-B-A'-B' designs were used to identify the changes in heart rate during active-assisted exercise, lower limb postural control exercise, and upper limb postural control exercise. Experiments were performed for four weeks. The heart rates at pre- and post-exercise were compared, and the time to reach MBorg 4 was measured. Results: In the active-assisted exercise, the average heart rates at pre- and post-exercise and after 10 min of exercise were 88, 89, and 87.7 bpm, respectively. In the repetitive comparison of pre- and post-exercise in the lower limb postural control exercise, the difference in the mean heart rate was 3.5 and 3 bpm in stable support and 14 and 14.5 bpm in unstable support, respectively. In the repetitive comparison of pre- and post-exercise in the upper limb postural control exercise, the difference in the mean heart rate was 6 and 4 bpm in stable support and 4 and 4.5 bpm in unstable support. The time required to reach MBorg 4 was short when both the upper and lower postural control exercises were performed in an unstable state. Conclusion: We suggest that combining proper postural control exercise with strength exercise and aerobic exercise, among others, may be effective in rehabilitating patients in the recovery stage after a heart transplant.