• Title/Summary/Keyword: and LabVIEW

Search Result 780, Processing Time 0.03 seconds

Development of Coolant/Waste-oil Separating and Cooling System with Chip Treatment (칩 처리가 포함된 절삭유/폐유 분리 및 냉각 시스템 개발)

  • Kim, Joong-Seon;Lee, Dong-Seop;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.16-23
    • /
    • 2017
  • For most machine tools, it is necessary to remove chips and coolant oil because it they will continue to be created during the manufacture of workpieces. Existing products that are in use are installed and used as they reflect depending on the characteristics of each device separately. This study proposes a method to remove the security chip as well as developing an integrated system capable of reducing coolant damage. The Leverage AutoCAD and CATIA program was used for 2D and 3D design, shapes were identified by utilizing the KeyShot program, and the load and displacement analysis of the development apparatus was performed utilizing the ANSYS program. After the prototype underwent sufficient design review, the mixed oil separation device had a complete sensor control program using the LabVIEW program. The chip design process for transferring experiments and experiments on the mixed oil cooling device were developed for performance tests of the product. The final product resulted in an increase in space utilization during commercialization, reduced installation costs, and caused social effects such as pulmonary flow reduction, which, through the economic costs, reduces pollution, resulting in various benefits to the industry, such as deceased errors in the workplace decreases.

Coordination Pattern of Upper Limb of Sweep Shot Movement in Ice Hockey (아이스하키 스위프 샷(Sweep shot) 동작의 상지의 협응 형태)

  • Choi, Ji-Young;Lee, Eui-Lin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.169-179
    • /
    • 2007
  • The purpose of this study was to investigate the relations between the segments of the body and to qualitatively analyze coordination pattern of joints and segments during Sweep Shot movement in Ice Hockey, by utilizing coordination variables was angle vs. angle plots. By the utilization the three dimensional anatomical angle cinematography, the angles of individual joint and segment according to sweep shot in ice hockey. The subjects of this study were five professional ice hockey players. The reflective makers were attached on anatomical boundary line of body. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and ice hockey stick were defined. The three dimensional anatomical angular displacement and coordination pattern of trunk and Upper limb(shoulder-elbow, elbow-wrist linked system) showed important role of sweep shot in ice hockey. As the result of this paper, for the successful movement of sweep shot in ice hockey, it is most important role of coordination pattern of trunk-shoulder, shoulder-elbow and elbow-wrist. specially turnk movememt as a proximal segment. Coordination pattern of Upper Limb(upperarm-forearm-hand) of Sweep Shot movement in Ice Hockey that utilizes coordination variables seems to be one of useful research direction to understand basic control mechanisms of Ice hockey sweep shooting linked system skill. this study result showed flexion-extension, adduction-abduction and internal-external rotation of trunk are important role of power and shooting direction coordination pattern of upper Limb of Sweep Shot movement in Ice Hockey.

fabrication of DMMP Thick Film Gas Sensor Based on SnO2 (산화주석을 기반으로 한 DMMP 후막가스센서 제작)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1217-1223
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas is dimethyl methyl phosphonate(C$_3$ $H_{9}$ $O_3$P, DMMP) that is simulant gas of nerve gas. Sensing materials were Sn $O_2$ added a-Al$_2$ $O_3$ with 0∼20wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor device was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Total size of device was 7${\times}$10${\times}$0.6㎣. Crystallite size & phase identification and morphology of fabricated Sn $O_2$ powders were analyzed by X-ray diffraction and by a scanning electron microscope, respectively. Fabricated sensor was measured as flow type and resistance change of sensing material was monitored as real time using LabVIEW program. The best sensitivity was 75% at adding 4wt.% $\alpha$-Al$_2$ $O_3$, operating temperature 30$0^{\circ}C$ to DMMP 0.5ppm. Response and recovery time were about 1 and 3min., respectively. Repetition measurement was very good with $\pm$3% in full scale.TEX>$\pm$3% in full scale.

Reliable Measurement and Analysis System for Ubiquitous Healthcare (고신뢰 유비쿼터스 헬스케어 데이터 측정 및 분석 시스템)

  • Jung, Sang-Joong;Seo, Yong-Su;Kim, Jong-Jin;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.293-297
    • /
    • 2009
  • This paper describes a real-time reliable measurement and analysis system for ubiquitous healthcare based on IEEE802.15.4 standard. In order to obtain and monitor physiological body signals continuously, wearable pulse oximeter is designed in wrist that could used to measure oxygen saturation of a patient unobtrusively. The measured data was transferred to a central PC or server by using wireless sensor nodes via a wireless sensor network for storage and analysis purposes. LabVIEW server program was designed to monitor and process the measured photoplethysmogram(PPG) to accelerated plethysmogram(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual's PPG and be used as estimation of vascular elasticity for blood circulation.

  • PDF

Study on IoT-based Map Inside the Building and Fire Perception System (IoT 기반 건물 내부 지도 및 화재 안내 시스템에 관한 연구)

  • Moon, Sung-Ryong;Cho, Joon-Ho
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.85-90
    • /
    • 2019
  • This paper is a study on IoT based map inside the building and fire perception system using microprocessor and LABVIEW program. The smart control system implemented in this paper is designed to identify the location of fire by using microprocessor, flame detection sensor, carbon monoxide sensor and temperature sensor, and to guide the optimal travel route through Zigbee communication. And the proposed system uses QR code to interoperate with smartphone. The coordinator control verified that the sensor value of the smart control system installed through the LABVIEW software was confirmed. The IoT based control system studied in this paper was implemented with Arduino mega board and LABVIEW software, and the operation status was confirmed by display device and coordination.

Implementation of a Falls Recognition System Using Acceleration and Angular Velocity Signals (가속도 및 각속도 신호를 이용한 낙상 인지 시스템 구현)

  • Park, Geun-Chul;Jeon, A-Young;Lee, Sang-Hoon;Son, Jung-Man;Kim, Myoung-Chul;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.54-64
    • /
    • 2013
  • In this study, we developed a falling recognition system to transmit SMS data through CDMA communication using a three axises acceleration sensor and a two axises gyro sensor. 5 healthy men were selected into a control group, and the fall recognition system using the three axises acceleration sensor and the two axises gyro sensor was devised to conduct an experiment. The system was attached to the upper of their sternum. According to the experiment protocol, the experiment was carried out 3 times repeatedly divided into 3 specific protocols: falling during gait, falling in stopped state, and falling in everyday life. Data obtained in the falling recognition system and LabVIEW 8.5 were used to decide if falling corresponds to that regulated in an analysis program applying an algorithm proposed in this study. In addition, results from falling recognition were transmitted to designated cellular phone in a SMS (Shot Message Service) form. These research results show that an erroneous detection rate of falling reached 19% in applying an acceleration signal only; 6% in applying an angular velocity; and 2% in applying a proposed algorithm. Such finding suggests that an erroneous detection rate of falling is improved when the proposed algorithm is applied incorporated with acceleration and angular velocity. In this study therefore, we proposed that a falling recognition system implemented in this study can make a contribution to the recognition of falling of the aged or the disabled.

A Study on the Aging Change of Exit Light by Measuring the Ratio of Luminance (휘도비 측정을 통한 유도등의 경년변화 연구)

  • Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.181-185
    • /
    • 2019
  • In this study, Exit light installed in offices, malls, hospitals, and factories were analyzed to analyze the luminance performance of CCFL and LED light sources. In addition, fire protection products with electrical characteristics such as Exit light may change their performance due to ambient temperature, humidity, and dust. So it was extracted by installation place and analyzed its characteristics. As a result of the experiment, Exit light for CCFL type showed the value of 'ratio of luminance 2' for large, medium and small. Considering that the reference value was 'lower than 9', the value was very good and it can be seen that there is almost no change in ratio of luminance due to aging. The Exit light for LED type showed a value of 'ratio of luminance 5', which means that the light on the display surface is not uniform. In addition, there was almost no change in ratio of luminance due to ageing, but the ratio of luminance was larger than Exit light for LED type. This is an unsatisfactory result from a visual point of view. To improve this, it is necessary to disperse the light of LED light source and strengthen the regulation on ratio of luminance.

A Study on the Emotional Value Perception and Post Adoption Behavior of Mobile Service (모바일 서비스의 감성적 가치인식과 후기수용행동 요인 연구)

  • Lee, Sang-Ho;Kim, Young-Berm;Kim, Jai-Beom
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.237-245
    • /
    • 2012
  • This study deals with the influencing factors for satisfaction and the emotional value perception of mobile voucher service user. Thus researcher examined a structural equation modeling methodology of the paths within word of mouth, satisfaction, and other exogenous variables (economic/rational value, trust, joyfulness, innovativeness). As a result of this study, First, it was confirmed that the emotional value, and innovativeness affected user's trust for coupon service and joyfulness for using mobile voucher. Second, it was confirmed that trust and joyfulness affected user's satisfaction and word of mouth activities. Therefore, in cases of utilizing the emotional appeal of mobile voucher as part of a marketing tool, corporate can maximize efficiency by using their mobile voucher service & event from the point of view of customer's satisfaction & voluntary word of mouth. Researcher's consideration is that this paper's theoretical and practical contribution point is the propose of the one of the post adoption model with the quantitative study of the mobile voucher service user's emotional perception in the initial development stages of high-tech industry.

Effect of Modified Fiber Tip on Joint Angle Measurement (광섬유 종단각도 효과를 이용한 관절각 측정)

  • Jung, Gu-In;Kim, Ji-Sun;Lee, Tae-Hee;Choi, Ju-Hyeon;O, Han-Byeol;Kim, A-Hee;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.929-933
    • /
    • 2014
  • The measurement of joint angle is important to evaluate the patient's disability. The modified fiber tip and light propagation of the developed fiber sensor were investigated to increase the range of angle detection. Different shapes of fiber tips were manufactured with a polishing machine to deliver light signal in various patterns. Output signals were analyzed to obtain joint angle change with inverse polynomial models. The measured joint angles were displayed with LabVIEW program and the reliability was tested by comparing with a commercial angle sensor. This method can be used in rehabilitation field to determine patient's progress.

Inchworm-Like Robotic Colonoscope UsingLegs for Clamping (다리를 이용한 클램핑 방식의 자벌레 이동방식 대장내시경로봇)

  • Park, Hyun-Jun;Leem, Sang-Hyuck;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.6
    • /
    • pp.789-795
    • /
    • 2010
  • For the reliable clamping of a robotic colonoscope inside the colon, we propose a clamping module consisting of six legs at the front and a trigger at the rear. In addition, a pneumatic-line based locomotive mechanism, which was developed previously for in-pipe inspection, is adopted to reduce the friction force between the pneumatic lines and the locomotion environment. In order to evaluate locomotion performance, a robot with a diameter of 15 mm and a length of 110.250 mm is used. Based on control signal from LabVIEW, it is tested in acrylic pipe and pig's colon. The proposed robot is able to move in the curved path which has a radius of over 25 mm. The speed of the robot is 33 mm/s in a straight path and 12.1 mm/s on a vertical path. The proposed robot, which has one pneumatic line and two clamping modules, conclusively shows reliable locomotion performance under in vitro condition.