• 제목/요약/키워드: and Infrared (IR) detector

검색결과 85건 처리시간 0.031초

Common Optical System for the Fusion of Three-dimensional Images and Infrared Images

  • Kim, Duck-Lae;Jung, Bo Hee;Kong, Hyun-Bae;Ok, Chang-Min;Lee, Seung-Tae
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.8-15
    • /
    • 2019
  • We describe a common optical system that merges a LADAR system, which generates a point cloud, and a more traditional imaging system operating in the LWIR, which generates image data. The optimum diameter of the entrance pupil was determined by analysis of detection ranges of the LADAR sensor, and the result was applied to design a common optical system using LADAR sensors and LWIR sensors; the performance of these sensors was then evaluated. The minimum detectable signal of the $128{\times}128-pixel$ LADAR detector was calculated as 20.5 nW. The detection range of the LADAR optical system was calculated to be 1,000 m, and according to the results, the optimum diameter of the entrance pupil was determined to be 15.7 cm. The modulation transfer function (MTF) in relation to the diffraction limit of the designed common optical system was analyzed and, according to the results, the MTF of the LADAR optical system was 98.8% at the spatial frequency of 5 cycles per millimeter, while that of the LWIR optical system was 92.4% at the spatial frequency of 29 cycles per millimeter. The detection, recognition, and identification distances of the LWIR optical system were determined to be 5.12, 2.82, and 1.96 km, respectively.

몰래카메라 범죄방지를 위한 스마트폰 연동 기반의 IR 열카메라 탐지기 개발 (Development of IR Thermal Camera Detector based on Smartphone Interlocking for Hidden Camera Crime Prevention)

  • 강영길;조필구;김영곤
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1-8
    • /
    • 2021
  • 몰카범죄의 증가에 발맞추어 은닉형 카메라는 스마트폰의 기술발전 속도에 따라 소형화 및 기술 집적이 고도화되어 성능이 날로 발전하고 있다. 이러한 외적인 네트워킹 컴퓨팅 환경이 고도화 되고, 활동이 많은 현대인의 생활양상이 다양화됨에 따라 일반 안전용 카메라외에 은닉형 카메라에 노출 또한 증가되고 있는 추세이다. 반면 은닉형 카메라를 탐지하고 예방하기 위한 기술은 이러한 은닉형 카메라 기술발전과 속도를 따라가지 못하고 있는 실정이다. 이에 본 연구에서는 일반영상과 열화상 이미지 합성기술을 바탕으로 적외선 열 방식의 탐지기술을 이용하여 은닉카메라의 발열을 감지하고, 주변 온도 차이에 따른 각 파장의 반사율을 분석하여 오탐율도 줄이도록 하였다.

분광복사조도 측정 장치 개발 (Development of Spectral Irradiance Measurement System)

  • 서정철
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.48-53
    • /
    • 2004
  • 광원의 분광복사조도를 250∼1600[nm] 파장 영역에서 정확하게 측정하기 위한 분광복사조도 측정 장치를 개발하였다. 분광복사조도 측정 장치는 광원 장치, 광학계, 분광장치, 광검출장치, 신호 처리 장치 등으로 이루어져 있다. 광검출 장치는 PMT, Si, InGaAs 및 IR enhanced InGaAs 광검출기를 이용함으로써 자외선, 가시광선, 적외선을 포함하는 넓은 파장 범위에서 광원의 스펙트럼을 측정할 수 있다. 개발된 측정 장치를 이용하여 1[kW] quartz-halogen 텅스텐 전구의 분광복사조도를 측정하여 비교하였는데, 측정 결과와 NIST에서 측정된 결과와는 차이는 450∼700[nm] 파장 영역에서 3[%] 이하이며, 700∼1600[m] 파장영역에서는 3.5[%] 이하이며, 250∼400[nm] 파장영역에서는 5[%] 이하로 측정되었다.

Optical System Design for Thermal Target Recognition by Spiral Scanning [TRSS]

  • Kim, Jai-Soon;Yoon, Jin-Kyung;Lee, Ho-Chan;Lee, Jai-Hyung;Kim, Hye-Kyung;Lee, Seung-Churl;Ahn, Keun-Ok
    • Journal of the Optical Society of Korea
    • /
    • 제8권4호
    • /
    • pp.174-181
    • /
    • 2004
  • Various kinds of systems, that can do target recognition and position detection simultaneously by using infrared sensing detectors, have been developed. In this paper, the detection system TRSS (Thermal target Recognition by Spiral Scanning) adopts linear array shaped uncooled IR detector and uses spiral type fast scanning method for relative position detection of target objects, which radiate an IR region wavelength spectrum. It can detect thermal energy radiating from a 9 m-size target object as far as 200 m distance. And the maximum field of a detector is fully filled with the same size of target object at the minimum approaching distance 50 m. We investigate two types of lens systems. One is a singlet lens and the other is a doublet lens system. Every system includes one aspheric surface and free positioned aperture stop. Many designs of F/1.5 system with ${\pm}5.2^{\circ}$ field at the Efl=20, 30 mm conditions for single element and double elements lens system respectively are compared in their resolution performance [MTF] according to the aspheric surface and stop position changing on their optimization process. Optimum design is established including mechanical boundary conditions and manufacturing considerations.

방폭형 적외선 가연성가스 누출검지기 개발 및 정확도 향상 연구 (A Study on the Development and Accuracy Improvement of an IR Combustible Gas Leak Detector with Explosion Proof)

  • 박규태;유근준;조영도;권정락;안상국;김희식
    • 한국가스학회지
    • /
    • 제18권3호
    • /
    • pp.1-12
    • /
    • 2014
  • 본 논문에서는 적외선센서를 이용하여 방폭형 휴대용 가연성가스 누출검지기를 개발하고 아울러 가스의 농도를 측정하는 정확도를 향상시키는 알고리즘을 제안하였다. 국내최초로 내압 및 본질안전방폭규격(Ex d ib) 적용하여 적외선 가스누출검지기는 개발하였으며, 선형회귀 방정식과 2차 라그랑지(Lagrange) 보간 다항식(interpolation polynomial)을 사용하여 측정정확도를 개선하였다. 아울러 본 연구에서는 현장검사원들의 요구사항을 조사하여 현장에 부합하도록 성능을 향상시키고, 편의기능을 추가하였다. 본 연구에서 개발한 가스누출검지기와 타사의 검지기를 비교하기 위하여 한국가스안전공사에서 제조한 표준가스 8종을 가지고 측정시험을 실시하였다. 본 연구에서 개발한 가스누출검지기의 검지 정확도가 우수함을 실험결과를 통하여 증명하였다.

자기신호처리 적외선 감지소자의 온도효과를 고려한 해석적 모델 (An analytical model considering temperature effects in self-signal processing infrared detectors)

  • 조병섭;곽계달
    • 전자공학회논문지A
    • /
    • 제32A권3호
    • /
    • pp.124-133
    • /
    • 1995
  • A theoretical self-consistent thermoelectric model has been developed for optimal thermal design in the self-signal processing infraed detectors. The model is achived by employing the coupled thermoelectric equation which allows which allows the simultaneous investigation of the termal and electrical aspects of device behavior. The thermal limitation of detectivity and responsivity are determined by the enegy gap, carrier concentration, lifetime, and mobility as a function of the temperature. The calculated results indicate that the detectivity is decreased at bias fields above about 50 V/cm, because the performence is limiting by temperature when the bias voltage reached the level associated with Joule heating. It has been also found that the improvement in the mid-band modulation transfer function(MTF) may be restricted by increasing the bias fields. Further, the important paramerers in the thermal optimization of SPIR detector, such as temperature in the device, ambipolar velocity, element thickness and length, are also considered. The analytical study provides a mathematical basis for optimal design of such a photoconductive IR detector and the agreement between the experimental and theoretical results are seen to be good.

  • PDF

방사선 검출기용 다이아몬드 막의 합성 (Synthesis of Diamond films for Radiation Detector)

  • 박상현;김정달;박재윤;김경환;구효근;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.366-369
    • /
    • 1999
  • Synthetic diamond films have been deposited on the silicon(100) surface and molybdenum substrates using an microwave plasma enhanced vapor deposition (MWPECVD) method. The effect of deposition time, surface morphology, X-ray diffraction pattrm, infrared transmittance and Raman Scattering have been studied, The diamond film deposited on Mo substrate for (100) hours at 40 torr H$_2$-CH$_4$O$_2$ gas system have been shown 1${\mu}{\textrm}{m}$/h of growth rate and good crystallization

  • PDF

Analysis of Dark Data of the PICNIC IR Arrays in the CIBER

  • Lee, D.H.;Kim, M.G.;Tsumura, K.;Zemcov, M.;Nam, U.W.;Bock, J.;Battle, J.;Hristov, V.;Renbarger, T.;Matsumoto, T.;Sullivan, I.;Levenson, L.R.;Mason, P.;Matsuura, S.;Kim, G.H.
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권4호
    • /
    • pp.401-406
    • /
    • 2010
  • We have measured and analyzed the dark data of two PICNIC IR arrays (P574 and P560) obtained through the Cosmic Infrared Background ExpeRiment (CIBER). First, we identified three types of bad pixels: the cold, the hot, and the transient, which are figured in total as 0.06% for P574 and 0.19% for P560. Then, after the bad pixels were masked, we determined the dark noise to be 20.5 ${\pm}$ 0.05 $e^-$ and 16.1 ${\pm}$ 0.05 $e^-$, and the dark current to be 0.6 ${\pm}$ 0.05 $e^-$/sec and 0.7 ${\pm}$ 0.05 $e^-$/sec for P574 and P560, respectively. Finally, we discussed glitches and readout modes for a future mission.

SWIR-LWIR Photoluminescence from Sb-based Epilayers Grown on GaAs Substrates by using MBE

  • Hussain, Laiq;Pettersson, Hakan;Wang, Qin;Karim, Amir;Anderson, Jan;Jafari, Mehrdad;Song, Jindong;Choi, Won Jun;Han, Il Ki;Lim, Ju Young
    • Journal of the Korean Physical Society
    • /
    • 제73권11호
    • /
    • pp.1604-1611
    • /
    • 2018
  • Utilizing Sb-based bulk epilayers on large-scale low-cost substrates such as GaAs for fabricating infrared (IR) photodetectors is presently attracting significant attention worldwide. For this study, three sample series of $GaAs_xSb_{1-x}$, $In_{1-x}Ga_xSb$, and $InAs_xSb_{1-x}$ with different compositions were grown on semi-insulating GaAs substrates by using molecular beam epitaxy (MBE) and appropriate InAs quantum dots (QDs) as a defect-reduction buffer layer. Photoluminescence (PL) signals from these samples were observed over a wide IR wavelength range from $2{\mu}m$ to $12{\mu}m$ in agreement with the expected bandgap, including bowing effects. In particular, interband PL signals from $InAs_xSb_{1-x}$ and $In_{1-x}Ga_xSb$ samples even at room temperature show promising potential for IR photodetector applications.

Analysis of Center Finding Algorithms for Telescope Autoguiding System

  • Lee, Hye-In;Pak, Soojong;Sim, Chae Kyung;Kang, Wonseok;Chun, Moo-Young;Jeong, Ueejeong;Yuk, In-Soo;Kim, Kangmin;Park, Chan
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.85.2-85.2
    • /
    • 2013
  • We developed autoguiding system for IGRINS (Immersion Grating Infrared Spectrograph) which is a high resolution near-IR spectrograph. This instrument will be attached on the 2.7m telescope at the McDonald observatory in 2013 November. IGRINS consists of three near-Infrared detector modules, i. e., H and K band spectrograph modules and a K band slit camera module, within which we are using the slit camera for autoguiding of the telescope. Comparing to typical optical CCDs, however, the infrared array shows non-uniform responses, higher noises, and many bad pixels. In this poster, we present methods to improve center finding functions and algorithms for the infrared array and the simulator test results of the IGRINS Slit-Camera Package.

  • PDF