Flow Characteristics of Ejector Driven Pipe According to the Changes of Diameter Ratio and End Position (이젝터 구동관로의 직경비와 끝단의 위치 변화에 따른 유동특성)

  • Kim, Noh Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • This study conducted CFD analysis on the mean velocity vector of distribution of the ejector driven pipe while changing the inlet velocity to 1 m/s at the diameter ratio of diffuser of 1:3, 1:2.25, 1:1.8 with the end position of driven pipe at 1, 1.253, 1.333, 1.467 respectively, which used $k-{\varepsilon}$/High Reynolds Number for the turbulence model, SIMPLE method for the analysis algorithm, and PIV experiment to verify the CFD analysis. As a result of the CFD analysis the optimum diameter ratio of ejector driven pipe was 1:3, the optimum end position of driven pipe was 1.333 for the diameter ratio of 1:3, 1:2.25, 1:1.8 and the PIV experiment obtained the same result as the CFD analysis. Therefore, the numerical analysis of the flow characteristics of ejector can be used for the optimum design implementation on ejector system.

Numerical Simulation of Flow and Dispersion Around Buildings using CFD Model

  • Ryu, Chan-Su
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.117-125
    • /
    • 2000
  • A series of simulations were carried out to test the accuracy of a CFD (Computational Fluid Dynamics) model for flow and dispersion problems around buildings. The basic equations involved are Reynolds-averaged Navier-Stokes equations. Two different cases were selected to estimate the accuracy of a CFD model. Case 1 adopted Euler equations, which are obtained by neglecting the viscous fluxes, which can be closed by the $textsc{k}$-$\varepsilon$model for a turbulent close problem. The results of both cases were compared with wind tunnel data. The results for Case 2 were closer to the wind both cases were compared with wind tunnel data. The results for Case 2 were closer to the wind tunnel data than Case 1. Accordingly, this indicates that the inclusion of viscous fluxes in a CFD model is required for the simulation of flow and 야spersion around buildings.

  • PDF

Performance Analysis of the Centrifugal Pump Impeller Using Commercial CFD Code (상용 CFD코드를 이용한 원심펌프 임펠러의 성능해석)

  • Choi, Young-Seok;Lee, Yong-Kab;Hong, Soon-Sam;Kang, Shin-Hyung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.1 s.10
    • /
    • pp.38-45
    • /
    • 2001
  • A commercial CFD code is used to compute the 3-D viscous flow field within the impeller of a centrifugal pump. Several preliminary numerical calculations are carried out to determine the influence of the parameters such as the grid systems, the numerical schemes, the turbulence models and the shape of the vaneless diffusers at the design flow rate. The results of the preliminary study are used for the calculation of the off-design flow conditions. The circumferentially averaged results such as the radial and tangential velocities, the exit flow angle, the slip factor, the static pressure and the total pressure are compared with the experimental data at the impeller exit to discuss the influence of the prescribed parameters.

  • PDF

Hybrid Parallelization for High Performance of CFD_NIMR Model (기상 모델 CFD_NIMR의 최적 성능을 위한 혼합형 병렬 프로그램 구현)

  • Kim, Min-Wook;Choi, Young-Jean;Kim, Young-Tae
    • Atmosphere
    • /
    • v.22 no.1
    • /
    • pp.109-115
    • /
    • 2012
  • We parallelized the CFD_NIMR model, which is a numerical meteorological model, for best performance on both of distributed and shared memory parallel computers. This hybrid parallelization uses MPI (Message Passing Interface) to apply horizontal 2-dimensional sub-domain out of the 3-dimensional computing domain for distributed memory system, as well as uses OpenMP (Open Multi-Processing) to apply vertical 1-dimensional sub-domain for utilizing advantage of shared memory structure. We validated the parallel model with the original sequential model, and the parallel CFD_NIMR model shows efficient speedup on the distributed and shared memory system.

Performance Analysis of the Centrifugal Pump Impeller Using Commercial CFD Code (상용 CFD코드를 이용한 원심펌프 임펠러의 성능해석)

  • Choi, Young-Seok;Lee, Yong-Kab;Hong, Soon-Sam;Kang, Shin-Hyung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.305-311
    • /
    • 2000
  • A commercial CFD code is used to compute the 3-D viscous flow field within the impeller o( a centrifugal pump. Several preliminary numerical calculations are carried out to determine the influence of the parameters such as the grid systems, the numerical schemes, the turbulence models and the shape of the vaneless diffusers at the design flow rate. The results of the preliminary study are used for the calculation of the off-design flow conditions. The circumferentially averaged results such as the radial and tangential velocities, the exit flow angle, the slip factor, the static pressure and the total pressure are compared with the experimental data at the impeller exit to discuss the influence of the prescribed parameters.

  • PDF

CFD Prediction on Vortex in Sump Intake at Pump Station (펌프 흡수정내 발생된 보텍스에 대한 CFD 예측)

  • Park, Sang-Eun;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.39-46
    • /
    • 2007
  • In large pump station, vortex generation such as free-surface vortex and submerged vortex occurring around pump intake, or at bell-mouth inlet has been an important flow characteristics which should be considered always to keep away the suction of air-entrained or cavitated flow. In this study, a commercial CFD code was used to predict accurately the vortex generation for the specified intake design. These result shows the preliminary result of submerged vortex prediction for the Turbo-machinery Society of Japan Sump Test CFD standard model. At bottom wall, air volume fraction (red color) was found in a large scale to explain the submerged vortex generation at particular operation and configuration condition. And these indicate the free surface formation behind the bell mouth. Particularly, non-uniform approaching flow is a major parameter to govern the occurrence of the free-surface vortex. Futhermore the comparison between turbulence ($k-{\epsilon}$ & $k-{\omega}$ model) mode were executed in this study.

A FRONTIER OF PARALLEL CFD: REAL-TIME IN-FLIGHT ICING SIMULATION OVER COMPLETE AIRCRAFT

  • Habashi, Wagdi G.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.1-1
    • /
    • 2010
  • With the power of supercomputers increasing exponentially, there is an insatiable need for more advanced multi-disciplinary aerospace CFD simulations. A particular current interest is the 3D viscous turbulent simulation of the highly nonlinear aspects of aero-icing. The applications of CFD in that field are literally light-years behind aerodynamics, with a significant number of users still mired in correlations, or 2D, inviscid, incompressible, and, yes, Panel Methods simulations! Thus, the disparity of tools between aerodynamics and icing departments within an organization leads to a disconnect that makes ice protection a downstream isolated process that is not an integral part of the aerodynamic behavior of an aerospace system (aircraft, rotorcraft, jet engine, UAV, etc.). While 3D RANS has been recently introduced, it is still considered computationally too demanding for industry when wide parametric studies for certification are required. In addition, not unlike the situation in aerodynamics say 20 years ago, naysayers are at every corner claiming that CFD is not reliable and is of limited use.

  • PDF

Prediction of Annular Type Seal Leakage Using 3D CFD (3차원 CFD를 사용한 환상 실의 누설량 예측)

  • Seok, Hee-Soo;Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.150-156
    • /
    • 2009
  • Precise leakage prediction for annular type seals of turbomachinery is necessary for enhancing their efficiency and various prediction methods have been developed. As the seal passage is designed intricately, the analysis based on Bulk-flow concept which has been mainly used in predicting seal leakage is limited. In order to improve the seal leakage prediction, full Navier-Stokes Equations with turbulent model derived in the seal flow passage have to be solved. In this study, 3D CFD (Computational Fluid Dynamics) analysis has been performed for predicting leakage of various non-contact type anular seals using FLUENT. Compared to the results by Bulk-flow model analysis, experiment, and 2D CFD analysis, the result of 3D CFD analysis shows improvement in predicting seal leakage, especially for the parallel grooved pump seal.

A Comparative Study of Leakage Flow Models for Scroll Compressors with CFD Solutions (스크롤 압축기 누설 모델의 CFD 해와의 비교 연구)

  • 강동진;홍석준;전현주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.843-851
    • /
    • 2003
  • The present paper studies the leakage flow model used in the performance prediction of a scroll compressor. Two leakage flow models, isentropic and Fanno flow model, are studied in detail. Their predictions are also compared with CFD solutions to check the validity as a leakage flow model. Comparison with CFD solutions shows that the isentropic flow model predicts excessive leakage flow rate, while the Fanno flow model shows acceptable agreement with CFD solutions. The excessive leakage flow rate by isentropic flow model results in under-prediction of the overall performance of a scroll compressor.

Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF