• Title/Summary/Keyword: and Analytical analysis

Search Result 9,284, Processing Time 0.042 seconds

Analytical solutions for skewed thick plates subjected to transverse loading

  • Chun, Pang-Jo;Fu, Gongkang;Lim, Yun Mook
    • Structural Engineering and Mechanics
    • /
    • v.38 no.5
    • /
    • pp.549-571
    • /
    • 2011
  • This paper presents analytical solutions for skewed thick plates under transverse loading that have previously been unreported in the literature. The thick plate solution is obtained in a framework of an oblique coordinate system. The governing equation is first derived in the oblique coordinate system, and the solution is obtained using deflection and rotation as partial derivatives of a potential function developed in this research. The solution technique is applied to three illustrative application examples, and the results are compared with numerical solutions in the literature and those derived from the commercial finite element analysis package ANSYS 11. These results are in excellent agreement. The present solution may also be used to model skewed structures such as skewed bridges, to facilitate efficient routine design or evaluation analyses, and to form special elements for finite element analysis. At the same time, the analytical solution developed in this research could be used to develop methods to address post-buckling and dynamic problems.

Development of Analytical Reference Material for Proficiency Test of Pesticide Multi-residue Analysis in Tomato (토마토 농약다성분분석 정도관리용 분석표준물질 개발)

  • Kim, Jong-Hwan;Oh, Young-Gon;Choi, Sung-Gil;Hong, Su-Myeong;Kim, Sun-bae;Woo, In-Duk;Kim, Jun-Young;Seo, Jong-Su
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.223-233
    • /
    • 2016
  • BACKGROUND: This study was to develop a analytical reference material including twenty pesticides in tomato. To use it for proficiency test, the suitability of homogeneity, storage stability, assigned values and uncertainty for analytical reference material were important.METHODS AND RESULTS: In order to develop a analytical reference material of tomato for multi-residue analysis of pesticides, twenty-pesticides were treated in tomato and the samples were frozen and homogenized. The homogeneity, stability, assigned value and uncertainty were calculated according to the requirements of the KS A ISO Guide 35, KS Q ISO 13528 and EURL-PT protocol. The values of the within-bottle standard variation(swb) and the between-bottle standard variation(sbb) were 0.9~6.5% of assigned value and the uncertainty(u*bb) due to inhomogeneity was also calculated as 0.6~1.9% for all pesticides. This indicated that it was satisfactory to be used as a analytical reference material. The storage stabilities of twenty-pesticides at room temperature and freezing conditions were assessed according to the requirement of the KS Q ISO Guide 35. All pesticides were stable at room temperature (20~30℃) for 8 days and freezing (-20℃) for 23 days.CONCLUSION: The feasibility of analytical reference material for pesticide multi-residue analysis in a tomato matrix was investigated. Homogeneity of within/between-bottle, uncertainty and stabilities at room temperature and freezing condition were satisfactory for a use of proficiency test and quality control. From these results, a analytical reference material would be applicable to monitor the proficiency test of pesticide analysis organizations to improve the reliability and consistency.

Analytical Discussion on Stochastic Hydrodynamic Modeling of Support Structure of HAWAII WTG Offshore Wind Turbine

  • Abaiee, M.M.;Ahmadi, A.;Ketabdari, M.J.
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-62
    • /
    • 2015
  • Floating structure such as tension leg platform, semi-submersible and spar are widely used in field of oil exploration and renewable energy system. All of these structures have the base cylinder support structure which have effective rule in overall dynamic of response. So the accurate and reliable modeling is needed for optimum design and understanding the physical background of these systems. The aim of this article is an analytical discussion on stochastic modeling of floating cylinder based support structure but an applicable one. Due to this a mathematical mass-damper-spring system of a floating cylinder of HAWAII WTG offshore wind as an applicable and innovative system is adopted to model a coupled degrees using random vibration in analytical way. A fully develop spectrum is adopted to solve the stochastic spectrum analytically by a proper approximation. Some acceptable assumption is adopted. The simplified but analytical and innovative hydrodynamic analysis of this study not only will help researcher to concentrate more physically on hydrodynamic analysis of floating structures but also can be useful for any quick, simplified and closed form analysis of a complicated problem in offshore engineering.

Analysis and hazard evaluation of heat-transfer fluids for the direct contact cooling system

  • Hong, Joo Hi;Lee, Yeonhee;Shin, Youhwan;Karng, Sarngwoo;Kim, Youngil;Kim, Seoyoung
    • Analytical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.323-332
    • /
    • 2006
  • This paper discusses several low-temperature heat-tranfer fluids, including water-based inorganic salt, organic salt, alcohol/glycol mixtures, silicones, and halogenated hydrocarbons in order to choose the best heat-transfer fluid for the newly designed direct contact refrigeration system. So, it contains a survey on commercial products such as propylene glycol and potassium formate as newly used in super market and food processing refrigeration. The stability of commercial fluids at the working temperature of $-20^{\circ}C$ was monitored as a function of time up to two months. And organic and inorganic compositions of candidate fluids were obtained by analytical instruments such as ES, XRF, AAS, ICP-AES, GC, and GC-MS. Analysis results indicate that commercial propylene glycol is very efficient and safe heat transfer fluids for the direct cooling system with liquid phase.

Analytical and Experimental Study for Electromagnetic Performances of a Tubular Linear Machine with Axially Magnetized Single-sided Permanent Magnets

  • Shin, Kyung-Hun;Jeong, Kyoung-Hun;Choi, Jang-Young;Hong, Keyyong;Kim, Kyong-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.432-438
    • /
    • 2015
  • This paper presents an electromagnetic analysis of a tubular linear machine with axially magnetized permanent magnets using improved analytical techniques. Based on the magnetic vector potential and a two-dimensional polar-coordinate system, the magnetic field and armature reaction field can be derived. Using these, equivalent circuit parameters, such as the electromotive force and inductance, can be obtained analytically. Finally, the generating characteristics are derived with the equivalent circuit method. In this study, the finite element method was employed to provide a comparative evaluation, and experiments were conducted to validate the results of the analytical analysis.

Introduction of the Rapid Analysis Method for PCBs in Insulating Oils and Its Comparison Study to the Analysis Method in Korea

  • Hong, Jang-Ho;Takahashi, Tomohumi;Ishizaka, Takahiro;Toita, Hideki;Min, Byung-Yoon;Honda, Katsuhisa
    • Environmental Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.11-18
    • /
    • 2011
  • The aim of this research was to introduce a new rapid analysis method (heating of the multi-layer silica gel column/alumina column) for polychlorinated biphenyls in insulating oils, and to compare our new method with the analytical method currently used in Korea. The entire pretreatment procedure was completed within 2 hr, using about only 20 mL of solvents via our rapid analytical method. Furthermore, the pretreatment procedure can always be uniformly performed, regardless of oil type (JIS 1~JIS 7 and KS 1~KS 7). The recovery rates were more than 89%, with relative standard deviations below 6.0%. In conclusion, this rapid analytical method could reduce the pretreatment time and solvent usage by 1/10 and between 1/25 and 1/50, respectively, compared to analytical method currently used in Korea.

Development of Multi-sample Loading Device for TEM Characterization of Hydroxyapatite Nanopowder

  • Lee, Jong-Moon;Kim, Jung-Kyun;Jeong, Jong-Man;Kim, Jin-Gyu;Lee, Eunji;Kim, Youn-Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.788-792
    • /
    • 2013
  • A shortcoming of using transmission electron microscopy (TEM) for structural analysis via electron diffraction is the relatively large error of the measurements as compared to X-ray diffraction. To reduce these errors, various internal standard methods from earlier studies have been widely used. We developed a new device to facilitate the application of internal standard methods in preparation of TEM grids used for nanopowder analysis. Through the application of a partial mask on the TEM grid, both the internal standards and the research materials can be loaded on the same grid. Through this process, we conducted a TEM analysis that compared synthetic hydroxyapatite (HAp) nanopowder to bone apatite from a bovine femur. We determined that the accuracy of the d-spacing measurements of the HAp and bone powders could be improved to better than 1% after statistical treatments of the experimental data. By applying a quarter mask, we loaded four different nanoparticles on a single TEM grid, with one section designated for the internal standard.

Theoretical analysis of superelastic SMA helical structures subjected to axial and torsional loads

  • Zhou, Xiang;You, Zhong
    • Smart Structures and Systems
    • /
    • v.15 no.5
    • /
    • pp.1271-1291
    • /
    • 2015
  • Helical structures made of superelastic shape memory alloys are widely used as interventional medical devices and active actuators. These structures generally undergo large deformation during expansion or actuation. Currently their behaviour is modelled numerically using the finite element method or obtained through experiments. Analytical tools are absent. In this paper, an analytical approach has been developed for analyzing the mechanical responses of such structures subjected to axial and torsional loads. The simulation results given by the analytical approach have been compared with both numerical and experimental data. Good agreements between the results indicate that the analysis is valid.

Analytical Method to Analyze the Effect of Tolerance on the Modal Characteristic of Multi-body Systems in Dynamic Equilibrium (동적 평형위치에 있는 다물체계의 모드특성에 미치는 공차의 영향 분석을 위한 해석적 방법)

  • Kim, Bum-Suk;Yoo, Hong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.579-586
    • /
    • 2007
  • Analytical method to analyze the effect of tolerance on the modal characteristic of multi-body systems in dynamic equilibrium position is suggested in this paper. Monte-Carlo method is conventionally employed to perform the tolerance analysis. However, Monte-Carlo method spends too much time for analysis and has a greater or less accuracy depending on sample condition. To resolve these problems, an analytical method is suggested in this paper. Sensitivity equations for damped natural frequencies and the transfer function are derived at the dynamic equilibrium position. By employing the sensitivity information of mass, damping and stiffness matrices, the sensitivities of damped natural frequencies and the transfer function can be calculated.

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF