• Title/Summary/Keyword: and ATR-FTIR

Search Result 138, Processing Time 0.02 seconds

ATR-FTIR Analysis of Adhesives Jointing Buddhist Scripture Scrolls in Medieval Korea(Goryeo Dynasty)

  • Oh, Joon Suk
    • Journal of Conservation Science
    • /
    • v.35 no.1
    • /
    • pp.11-18
    • /
    • 2019
  • The adhesives joining Buddhist scripture scrolls from medieval Korea(Goryeo Dynasty, A.D. 918~1392) are different from wheat starch adhesive. The composition of the adhesive was analyzed using Attenuated Total Reflectance-Fourier Transform Infrared(ATR-FTIR) spectroscopy. In the adhesive used to join Buddhist scripture scrolls, peaks attributed to amide I and amide II of the protein and carbohydrate were detected in the ATR-FTIR spectra, and no carbonyl peak($1745cm^{-1}$) for oil was detected in the 2nd derivative ATR-FTIR spectra. The ATR-FTIR spectra almost coincided with those of defatted soybean powder adhesive. Hence, the adhesives joining Buddhist scripture scrolls were inferred to be soybean adhesive prepared from a defatted soybean cake.

The Hydrolysis Measurement of Cyclodextrins Using FTIR-ATR Spectrometry (FTIR-ATR 분광법을 이용한 사이클로덱스트린의 가수분해 측정)

  • Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.549-557
    • /
    • 2000
  • FRIR-ATR spectrometry has been used to monitor the aqueous reactions of compounds without distinct chromophores in ultraviolet and visible regions. For example, hydrolysis reactions of ${\alpha}$-cyclodextrin and ${\gamma}$-cyclodextrin in acidic aqueous solution were studied. FTIR-ATR method has been used for the monitoring of cyclodextrin hydrolysis in 1.0 M. 0.5 M, and 0.1 M HCl solutions, respectively. We also found that the hydrolysis of ${\alpha}$-cyclodextrin produced glucose, but the hydrolysis of ${\gamma}$-cyclodextrin proceeded further to give more fragmented products than glucose.

  • PDF

Evaluation of Water Absorption Phenomena into the Photo-resist Dry Film for PCB Photo-lithography Process (PCB Photo-lithography 공정에 사용되는 Photo-resist인 Dry Film에 대한 물의 확산 침투 현상평가)

  • Lee, Choon Hee;Jeong, Giho;Shin, An Seob
    • Applied Chemistry for Engineering
    • /
    • v.24 no.6
    • /
    • pp.593-598
    • /
    • 2013
  • In this study, we have evaluated the water absorption phenomenon of photoresist dry film, which is commonly used to build circuits on PCB (Printed Circuit Board) by photolithography, by using ATR-FTIR (Attenuated Total Reflectance-Fourier Transform Infrared). We have firstly observed significant change in fracture mode of dry film with respect to temperature and humidity, which we assumed the material transition from ductile to brittle. Secondly, we have established the process of absorption test for determining the diffusion coefficients of water into the dry film both with gravimeter and ATR-FTIR. We have successfully calculated the diffusion coefficients for each environmental conditions from the results which we achieved by gravimeter and ATR-FTIR. Compared to the gravimeter which is a conventional method for absorption test, the ATR-FTIR method in this study has been found to be very easy to use and have the same accuracy as gravimeter. Moreover, we are expecting to use the ATR-FTIR as an appropriate method to study the absorption phenomena related to any kinds of solvent and polymer system.

Correlation between Physico-Mechanical and Rheological Properties of Rubber Compounds Based on NR-BR with C-C Gel Content in Polybutadiene (NR-BR 기반 고무소재에서 폴리부타디엔의 C-C 겔 함량과 물리기계적, 유변학적 특성 사이의 상호관계)

  • Ganjali, Saeed Taghvaei;Motiee, Fereshteh;Tabatabaie, Zohreh Ghazi
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.425-433
    • /
    • 2014
  • In this study, microstructure and gel content (C-C) of polybutadiene rubber (PBR) were investigated using various techniques including ASTM D 3616, attenuated total reflectance Fourier transform infrared spectrometry (ATR FTIR), differential scanning calorimetry (DSC) and nuclear magnetic resonance spectroscopy (NMR). The ATR FTIR spectra of the samples were investigated to determine the cis, trans, 1, 2-vinyl and the C-C gel content in PBR. The absorbance ratios of specific peaks in different grades of PBR were correlated with the C-C gel content measured by the ATR FTIR techniques. Physico-mechanical and rheological properties of rubber compounds based on BR with various amounts of gel were determined. The results showed that there is an acceptable correlation between these properties and the C-C gel content of PBR.

Attenuated total reflection Fourier transform infrared as a primary screening method for cancer in canine serum

  • Macotpet, Arayaporn;Pattarapanwichien, Ekkachai;Chio-Srichan, Sirinart;Daduang, Jureerut;Boonsiri, Patcharee
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.16.1-16.10
    • /
    • 2020
  • Cancer is a major cause of death in dogs worldwide, and the incidence of cancer in dogs is increasing. The attenuated total reflection Fourier transform infrared spectroscopic (ATR-FTIR) technique is a powerful tool for the diagnosis of several diseases. This method enables samples to be examined directly without pre-preparation. In this study, we evaluated the diagnostic value of ATR-FTIR for the detection of cancer in dogs. Cancer-bearing dogs (n = 30) diagnosed by pathologists and clinically healthy dogs (n = 40) were enrolled in this study. Peripheral blood was collected for clinicopathological diagnosis. ATR-FTIR spectra were acquired, and principal component analysis was performed on the full wave number spectra (4,000-650 cm-1). The leave-one-out cross validation technique and partial least squares regression analysis were used to predict normal and cancer spectra. Red blood cell counts, hemoglobin levels and white blood cell counts were significantly lower in cancer-bearing dogs than in clinically healthy dogs (p < 0.01, p < 0.01 and p = 0.03, respectively). ATR-FTIR spectra showed significant differences between the clinically healthy and cancer-bearing groups. This finding demonstrates that ATR-FTIR can be applied as a screening technique to distinguish between cancer-bearing dogs and healthy dogs.

The application of a chemical assessment of archaeological animal bone by Fourier transform infrared spectroscopy and x-ray diffraction (FTIR과 XRD를 이용한 출토 동물뼈의 화학적 평가 적용)

  • Kang, Soyeong;Cho, Eun Min;Kim, Sue Hoon;Kim, Yun-Ji;Lee, Jeongwon
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.300-307
    • /
    • 2014
  • For the application of chemical assessment standards by the extent of diagenetic alteration, we investigated three archaeological animal bones and a modern animal bone using Fourier transform infrared-attenuated total reflection (FTIR-ATR) spectroscopy and x-ray diffraction (XRD) analysis. The calculating results of crystallinity index (CI), carbonate-to-phosphate (C/P) and carbonate-to-carbonate (C/C) using FTIR-ATR spectra showed differences CI and C/P according to the preservative condition of animal bones. By comparison of the crystallinity contents using XRD patterns, the states of animal bones were distinguished to the range of $30^{\circ}-35^{\circ}$. As results of FTIR-ATR and XRD analysis, it is suggested that Mongolian large mammals bone presents the best preservative condition, and cattle bone from Naju site, and Haman site followed. In addition, those were correlated with the results of histological index. The results suggested that the chemical assessment standards may contribute to application of predictions of the states of animal bones discovered from Korea.

Refractive Index Changes of Polymer Film by Photochemical Reactions (광반응에 의한 고분자 필름의 굴절률 변화)

  • 조정환;신미영;이종하;김성수;송기국
    • Polymer(Korea)
    • /
    • v.28 no.6
    • /
    • pp.545-550
    • /
    • 2004
  • The refractive index of thin copolymer film was controlled by photo-degradation of chromophores in the copolymer. FTIR and UV/Vis spectroscopy were employed to elucidate the effect of chemical structure on refractive index changes after photobleaching. The decrease of refractive index of the film by photobleaching can be ascribed to the decrease of polarizability of polymer molecules through breakage of C =C bond in the chromophore. Due to the selective photoreaction of the chromophores which align along the film plane, refractive index of the copolymer film measured in TE mode decreases faster than that in TM mode. Polarized ATR-FTIR spectroscopy was used to verify such a difference in refractive index of the film.

Preparation of Atomically Flat Si(111)-H Surfaces in Aqueous Ammonium Fluoride Solutions Investigated by Using Electrochemical, In Situ EC-STM and ATR-FTIR Spectroscopic Methods

  • Bae, Sang-Eun;Oh, Mi-Kyung;Min, Nam-Ki;Paek, Se-Hwan;Hong, Suk-In;Lee, Chi-Woo J.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1822-1828
    • /
    • 2004
  • Electrochemical, in situ electrochemical scanning tunneling microscope (EC-STM), and attenuated total reflectance-FTIR (ATR-FTIR) spectroscopic methods were employed to investigate the preparation of atomically flat Si(111)-H surface in ammonium fluoride solutions. Electrochemical properties of atomically flat Si(111)-H surface were characterized by anodic oxidation and cathodic hydrogen evolution with the open circuit potential (OCP) of ca. -0.4 V in concentrated ammonium fluoride solutions. As soon as the natural oxide-covered Si(111) electrode was immersed in fluoride solutions, OCP quickly shifted to near -1 V, which was more negative than the flat band potential of silicon surface, indicating that the surface silicon oxide had to be dissolved into the solution. OCP changed to become less negative as the oxide layer was being removed from the silicon surface. In situ EC-STM data showed that the surface was changed from the initial oxidecovered silicon to atomically rough hydrogen-terminated surface and then to atomically flat hydrogenterminated surface as the OCP moved toward less negative potentials. The atomically flat Si(111)-H structure was confirmed by in situ EC-STM and ATR-FTIR data. The dependence of atomically flat Si(111)-H terrace on mis-cut angle was investigated by STM, and the results agreed with those anticipated by calculation. Further, the stability of Si(111)-H was checked by STM in ambient laboratory conditions.

Phosphate Adsorption-Desorption of Kaolinite KGa-2 (Source Clay) (카올리나이트 KGa-2 (표준 점토)의 인산염 흡착-탈착 특성)

  • Cho, Hyen-Goo;Choi, Jae-Ho;Moon, Dong-Hyuk;Kim, Soo-Oh;Do, Jin-Youn
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.117-127
    • /
    • 2008
  • The characteristics of phosphate adsorption-desorption on kaolinite was studied by batch adsorption experiments and detailed adsorbed state of phosphate on kaolinite surface was investigated using ATR-FTIR (Attenuated Total Reflectance-Fourier Transform Infrared) spectroscopy. The phosphorous contents were measured using UV-VIS-IR spectrophotometer with 820 nm wavelength. The adsorbed P was generally increased with increasing pH value in the range of pH 4 to pH 9, however it is not distinct. Moreover the adsorbed P was significantly changed with different initial phosphate concentration. The adsorption isotherms were well fitted with the Langmuir equation, Temkin equation, and Freundlich equation in descending order. The maximum Langmuir adsorption capacity of kaolinite KGa-2 is 232.5 ($204.1{\sim}256.5$) mg/kg and has very higher value than that of kaolinite KGa-1b. Most of adsorbed phosphate on kaolinite were not easily desorbed to aqueous solution, but might fixed on kaolinite surface. However it needs further research about the exact desorption experiment. It was impossible to recognize phosphorous adsorption bands on kaolinite in ATR-FTIR spectrum from kaolinite bands themselves, because the absorption peaks of phosphorous have very similar positions with those of kaolinite, and the intensities of the former were very weak in comparison with those of the latter.

Surface Treatment of Polypropylene using a Large Area Atmospheric Pressure Plasma-solution System (대면적 대기압 플라즈마-용액 시스템을 이용한 폴리프로필렌 표면 처리)

  • Tran, Chinh Quoc;Choi, Ho-Suk
    • Korean Chemical Engineering Research
    • /
    • v.49 no.3
    • /
    • pp.271-276
    • /
    • 2011
  • We investigated the possibility of introducing functional groups without damaging surface polymeric chains through the treatment of a polypropylene(PP) film immersed in liquid phase using an atmospheric pressure plasma with large area. The ionic liquid of 1-butyl-3-methylimidazolium tetrafluoroborate: $[BMIM]^{+}[BF_{4}]^{-}$- was successfully applied for generating stable plasmas in the plasma-solution system. We successfully treated the film surface using the plasma-solution system and confirmed various oxygen-containing functional groups formed on the surface of PP film. The surface free energy of PP film was increased with increasing plasma treatment time and power. It also showed a maximum value at the PP sample treated in the ionic liquid solution of 1.5 M. ATR-FTIR analyses revealed the increase of various carbonyl groups(1,726 $cm^{-1}$, 1,643 $cm^{-1}$) and OH groups$(3,100{\sim}3,500\;cm^{-1})$ after plasma treatment of PP film, and XPS also supported the ATR-FTIR result.