• Title/Summary/Keyword: anchorage strength

Search Result 198, Processing Time 0.024 seconds

Influence of Anchorage of T-Plate on the Seismic Performance of RC Columns Strengthened with Unbounded Wire Rope Units (와이어로프 기반 비부착 보강된 RC 기둥의 내진거동에 대한 T형 강판 정착의 영향)

  • Sim, Jae-Il;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.133-140
    • /
    • 2010
  • Five strengthened columns and an unstrengthened column were tested under constant axial load and cyclic lateral loads to examine the seismic performance of the unbounded strengthening procedure using wire ropes and T-plates. Main variables considered were the presence of mortar cover for strengthening steel element and anchorage method of T-plate. Test results clearly showed that T-plates having a proper anchorage contribute to transfer of applied moment as well as enhancement of ductility of reinforced concrete columns. However, T-plate not anchored fully into a column base can seldom transfer the externally applied moment, though it highly improves the ductility of column. The presence of mortar cover for strengthening steel elements is significantly effective in enhancing the initial stiffness and flexural capacity of the strengthened columns, but has an adversely effect on enhancing the ductility. The ultimate moment strength predicted from the extended section laminae method in better agreement with test results compared with predictions obtained using stress black specified in ACI 318-05.

Plate Separation (에폭시 접착강판으로 보강된 철근콘크리트 보의 강판단부의 거동특성)

  • 신영수;최완철;홍기섭;홍영균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.374-379
    • /
    • 1994
  • This paper deals with the problem of plate separation and anchorage at the ends of steel plates strengthened by EBSP. Test results show that the reinforced concrete beams strengthened by EBSP occurs the premature failure without the beams achieving their full flexural strength at the end of plates. The premature failure is the cause of stress concentrations in the adhesive layer of plate, reinforced concrete incase of lack of plate length. Then a simple, approximate procedure for predicting the shear and normal stress concentrations is investigated by Robert's the ory based on partial interaction theory. The theoretical results are compared, and show close agreement with test results. A method is derived for determining the plate length that prevents the premature anchorage zone failure

  • PDF

Experimental Study on the Bond[ Behavior with Concrete Surface Preparation. and Anchorage Type of CFRP (콘크리트 표면처리와 CFRP 단부정착 방법에 따른 부착특성실험)

  • 유영준;조정래;정우태;박종섭;박영환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.579-584
    • /
    • 2003
  • For strengthening deteriorated concrete structures, externally bonded FRP sheets or plates using epoxy resins are widely used. For the external FRP composites to be effective in improving the performance of the structure, bond between FRP composites and concrete is required. In general, the most frequently observed failure mode in FRP strengthened concrete structures is debonding failure at the interfacial section between FRP and concrete. Therefore, it is very important to find out the interfacial behavior properties. This paper presents experimental results of the relationship of concrete and FRP sheet for some conditions including concrete compressive strength, concrete surface preparation to observe the bond behavior between concrete and FRP sheet and various anchorage types to increase the bond capacity of FRP sheet.

  • PDF

Applications of Fiber Reinfored Composite in Dental Practice (Fiber Reinforced Composite를 이용한 치료 증례)

  • Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • This case reports describe a new approach to the use of polymers in orthodontics, using a fiber reinforced composite(FRC). FRC was successfully used in a periodontal splints, fiber post for endodontic use, orthodontic retainer and space maintainers, implant prosthesis, large span bridge, management of cracked tooth, anchorage reinforcement in orthodontics. FRC has highly favorable mechanical properties, and its strength-to-weight ratios is superior to those of most alloys. FRC has potential for use in many applications in dentistry and is expected to gain increasing application and popularity in dentistry. These case reports show that FRC is a promising anchorage reinforcement material for use in orthodontic practice.

Strengthening of RC beams with prefabricated RC U cross-sectional plates

  • Demir, Ali;Tekin, Muhammed;Turali, Tezcan;Bagci, Muhiddin
    • Structural Engineering and Mechanics
    • /
    • v.49 no.6
    • /
    • pp.673-685
    • /
    • 2014
  • The topic of this study is to strengthen cracked beams with prefabricated RC U cross-sectional plates. The damaged beams were repaired by epoxy based glue. The repaired beams were strengthened using prefabricated plates. The strengthening plates were bonded to the bottom and side faces of the beams by anchorage rods and epoxy. The strengthened beams were incrementally loaded up to maximum load capacities. The experimental results were satisfactory since the load carrying capacities of damaged beams were increased approximately 76% due to strengthening. It was observed that strengthening plates had a dominant effect on the performance of beams in terms of both the post-elastic strength enhancement and the ductility. The experimental program was supported by a three-dimensional nonlinear finite element analysis. The experimental results were compared with the results obtained from the beam modeled with ANSYS finite element program.

A Study on the Structural Strength Evaluation for the Development of One-ton Grade Commercial Vehicle Seat Frame for the FMVSS 201 Model (1톤급 상용차 시트 개발에 따른 FMVSS 210 Model 구조 강도 평가 연구)

  • Cho, Kyu-Chun;Ha, Man-Ho;Moon, Hong-ju;Kim, Young-Gon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.2
    • /
    • pp.130-136
    • /
    • 2018
  • This study develops a seat with electric motor technology for a one-ton grade commercial vehicle. While applying electric motor technology, the FMVSS 210 seat frame strength test is also conducted to examine the product's weak parts. The seat frame strength test used the FMVSS 210 test standard and the ANSYS program was used to simulate the test and identify weak parts in the deformation and strain values. The test results showed that the cushion frame and slide rail connection bracket were fractured at loads of about 10,000 N. Similarly, the maximum stress and strain values in the bracket were obtained in the simulation results. On this basis, it was evaluated that the connection part bracket was a considerably weak part in the case of the first model, and changing the shape of the bracket and reinforcing the strength were required. In addition, the seat belt anchorage test results and simulation results were compared to assure their validity. In the comparison results, the error for each is about 5-10%. Therefore, the simulation performed in this study is considered to have produced reasonably accurate results.

Punching Shear Strength of Slab-Column Interior Connection Considering Anchorage Performance of Shear Reinforcements (전단보강재의 정착성능을 고려한 슬래브-기둥 내부접합부의 뚫림전단강도)

  • Jung, Hyung-Suk;Choi, Hyun-Ki;Chung, Joo-Hong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.51-58
    • /
    • 2022
  • Flat plate slab is cost-efficient structural system widely used in high rise building, apartment and parking garages. But flat plate-column connections are so weak against punching shear failure that it may cause collapse of overall structure. In this study, spiral type shear reinforcement which increases the shear strength and ductility of the plate-column connection and has good workability was proposed. And experimental test was performed to verify the punching shear capacity of spiral type shear reinforcement. The current code does not accurately estimate the punching shear strength of slab-column connection with shear reinforcement because slab is so slender that punching failure may occurred before shear reinforcement reached yield stress. Therefore modified equation of ACI code for punching shear strength was proposed base on finite element analysis using LUSAS program, and data analysis from CEB-FIP database.

Prediction of Shear Strength for Large Anchors Considering the Prying Effect and Size Effect

  • Kim, Kangsik;Lee, Kwangsoo;An, Gyeonghee
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.4
    • /
    • pp.451-460
    • /
    • 2016
  • An anchorage system is necessary in most reinforced concrete structures for connecting attachments. It is very important to predict the strength of the anchor to safely maintain the attachments to the structures. However, according to experimental results, the existing design codes are not appropriate for large anchors because they offer prediction equations only for small size anchors with diameters under 50 mm. In this paper, a new prediction model for breakout shear strength is suggested from experimental results considering the characteristics of large anchors, such as the prying effect and size effect. The proposed equations by regression analysis of the derived model equations based on the prying effect and size effect can reasonably be used to predict the breakout shear strength of not only ordinary small size anchors but also large size anchors.

An Experimental Study on the Bond Failure Behavior between Parent Concrete and CFM (콘크리트와 탄소섬유메쉬의 부착파괴 거동에 관한 실험적 연구)

  • 오재혁;성수용;한병찬;윤현도;서수연;김태용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.965-970
    • /
    • 2002
  • The strengthening of concrete structures in situ with externally bonded carbon fiber is increasingly being used for repair and rehabilitation of existing structures. Carbon fiber is attractive for this application due to its good tensile strength, resistances to corrosion, and low weight. Generally bond strength and behavior between concrete and carbon fiber mesh(CFM) is very important, because of the enhanced bond of CFM. Therefore if bond strength is sufficient, it will be expected to enhance reinforcement effect. If insufficient, reinforcement effect can not be enhanced because of bond failure between concrete and CFM. This study is to investigate the bond strength of CFM to the concrete using direct pull-out test and tensile-shear test. The key variables of the experiment are the location of clip, number of clips and thickness of cover mortar. The general results indicate that the clip anchorage technique for increasing bond strength with CFM appear to be effective to maintain the good post-failure behavior.

  • PDF

Numerical method for the strength of two-dimensional concrete struts

  • Yun, Y.M.
    • Computers and Concrete
    • /
    • v.28 no.6
    • /
    • pp.621-634
    • /
    • 2021
  • For the reliable strut-and-tie model (STM) design of disturbed regions of concrete members, structural designers must accurately determine the strength of concrete struts to check the strength conditions of a selected STM el and the anchorage of reinforcing bars in nodal zones. In this study, the author proposed a consistent numerical method for strut strength, applicable to all two-dimensional STMs. The proposed method includes the effects of a biaxial stress state associated with tensile strains in reinforcing bars crossing a strut, deviation angle between strut orientation and compressive principal stress flow, and degree of confinement provided by reinforcement. The author examined the method's validity through the STM prediction of the ultimate strengths of 517 reinforced concrete (RC) deep beams, 24 RC panels, and 258 RC corbels, all tested to failure.