• 제목/요약/키워드: analytical values

Search Result 1,436, Processing Time 0.028 seconds

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

Evaluation of Significance & Development of Quantitative Measurement System for Acupoint Pigmentation by Cupping Therapy (부항요법에 의한 배수혈 혈색소 변화의 정량적 측정 시스템 개발 및 유의성 평가)

  • Kim, Soo-Byeong;Lee, Na-Ra;Jung, Byung-Jo;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • Objectives : The aim of this study is to develop the system and evaluate the optical analytical technique that reflects acupoint pigmentation and extravasated blood by cupping. Methods : We designed the system able to express XYZ coordinate on local skin color. To evaluate measurement-accuracy, we compared with 24 Color Checker Chart by standardized Commission Internationale de l'Eclairage. After confirming the performance of system, we experimented with cupping which was 80 kPa negative pressure for 1 minute on left/right BL13. The X, Y and Z values were converted to R, G and B, $L^*$, $a^*$ and $b^*$, Erythema Index (E.I.), and Melanin Index (M.I). We compared and analyzed two cases on before/after cupping. Results : The R, G and B values which were converted by X, Y and Z values had high linearity as a high level of R-square (R: 0.969, G: 0.996, and B: 0.992). Moreover, we confirmed that it was possible to quantitatively analyzed the change in skin color by cupping using R, G, B, $L^*$, $a^*$, $b^*$, E.I., and M.I. Conclusions : Therefore, we proposed the new analytical technique for objectifying the oriental medical diagnostic method using cupping and optical sensing technique.

A Study Effect of Mixed Solvents on the Retention of Polystyrenes Using Thermal Field-Flow Fractionation (열장 흐름 분획법에 의한 폴리스티렌의 머무름에 미치는 혼합용매의 영향에 관한 연구)

  • Lee, Dai-Woon;Jeon, Sun-Joo;Park, Won-Choul
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.453-462
    • /
    • 1993
  • The retention behaviors of polystyrenes influenced by mixed solvents are examined in thermal field-flow fractionation(ThFFF). Experimental data are obtained with polystyrene samples of molecular weights of 35,000, 110,000, 200,000 and 470,000 dissolved in organic solvents. The pure and mixed solvents are tetrahydrofuran(THF), chloroform(CHL), cyclohexane(CH), and benzene(BZ), respectively. The values of retention ratio(R) and thermal diffusion coefficient($D_T$) are measured with change of molecular weight and composition of mixed solvents. Atempts are then made to correlate the measured values with various physicochemical parameters of polymers and solvents. Studies suggest that R is significantly increased with the density of solvent and a good correlation is found between them. $D_T$ values decreases in the mixed solvent having has a higher concentration of poor solvent.

  • PDF

Correlation between Analytic and Experimental Results on Inelastic Behavior of Reinforced Concrete Frame

  • Lee, Han-Seon;Kim, Sang-Dae;Park, Cheol-Yong;Ko, Dong-Woo
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.3E
    • /
    • pp.173-181
    • /
    • 2006
  • The objectives of this study are to evaluate the reliability of an existing nonlinear analysis program for predicting the inelastic behavior of reinforced concrete frame with seismic details and to observe the redistribution of the internal forces, which can not be easily measured by an experiment. In order to carry out this task, the nonlinear analysis program of IDARC 2D(3) was run on a 2-bay, 2-story moment-resisting reinforced concrete plane frame with seismic details. (1) The effort to obtain the results of the analysis similar to those of experiment was made by determining the appropriate values of model parameters. The comparison of the analysis results with those of experiment and the observation of the distribution of internal forces obtained through nonlinear analysis points to the following conclusions. (1) The overall relationship between lateral load and lateral displacement given by the analysis is similar to that of experiment. However, the values of initial stiffness and the amount of energy dissipation in the initial displacement steps given by the analysis show larger values than those of experiment. (2) The analysis provided detailed information on the distribution and redistribution of internal forces and proved useful in elucidating the crack pattern, the sequence of the occurrence of plastic hinges, and the failure or yielding mechanism for the whole structure. (3) In spite of the similarity in overall behavior of analysis and experiment, there exists a significant discrepancy in some local behaviors. Furthermore, the hysteresis in the relationship between moment and curvature in some column ends have shown sudden deteriorations in strength, which can not be interpreted satisfactorily at the present time. Therefore, it is necessary to develop a better analytical model to fill this knowledge gap.

Analytical, experimental and numerical study of timber-concrete composite beams for bridges

  • Molina, Julio C.;Calil, Carlito Junior;de Oliveira, Diego R.;Gomes, Nadia B.
    • Computers and Concrete
    • /
    • v.24 no.2
    • /
    • pp.103-115
    • /
    • 2019
  • In this study, the strength and stiffness (EI) of wood-concrete composite beams for bridges with T-shaped cross section were evaluated. Two types of connectors were used: connectors bonded with epoxy adhesive and connectors attached to the wood just by pre-drilling (without adhesive). The connectors consisted of common steel bars with a diameter of 12.5 mm. Initially, the strength and stiffness (EI) of the beams were analyzed by bending tests with the load applied at the third point of the beam. Subsequently, the composite beams were evaluated by numerical simulation using ANSYS software with focus on the connection system. To make the composite beams, Eucalyptus citriodora wood and medium strength concrete were used. The slip modulus K and the ultimate strength values of each type of connector were obtained by direct shear tests performed on composite specimens. The results showed that the connector glued with epoxy adhesive resulted in better strength and stiffness (EI) for the composite beams when compared to the connector fixed by pre-drilling. The differences observed were up to 10%. The strength and stiffness (EI) values obtained analytically by $M{\ddot{o}}hler^{\prime}$ model were lower than the values obtained experimentally from the bending tests, and the differences were up to 25%. The numerical simulations allowed, with reasonable approximation, the evaluation of stress distributions in the composite beams tested experimentally.

An Analysis of Heat Transfer and Pressure Drop Characteristics for Optimum Design of Cryogenic Heat Exchanger used for Liquid Nitrogen Cooling (액체질소 냉각용 극저온 열교환기의 최적설계를 위한 열전달 및 압력강하 특성 분석)

  • Ko, Ji Woon;Jeon, Doong Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.24-32
    • /
    • 2018
  • In this paper, analytical studies were conducted to obtain optimal design factors and analysis parameters of liquid nitrogen cooling exchanger applied in cryogenic refrigerator. The target value of heat transfer rate was more than 1 kW and pressure drop was less than 40 kPa. Design factors of cryogenic heat exchanger included width of channel and configuration of paths. Analytical factors of liquid nitrogen cooling exchanger included temperatures of coolant header surface and inlet liquid nitrogen. The width and number of channels in the design parameters were 0.0050~0.0150 m and 4~8, respectively. The configuration of channel path was 4 ways. Temperatures of coolant header surface and inlet liquid nitrogen in analytical parameters were 74 to 78K and 82 to 86K, respectively. As result, the design factor and analysis parameter satisfying the target values were obtained. The biggest heat transfer rate was 1.36 kW with pressure drop of 32.26 kPa.

Analytical study of house wall and air temperature transients under on-off and proportional control for different wall type

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.1
    • /
    • pp.70-81
    • /
    • 2010
  • A mathematical model is formulated to study the effect of wall mass on the thermal performance of four different houses of different construction. This analytical study was motivated by the experimental work of Burch et al. An analytical solution of one -dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures is obtained using the Laplace transform method. Typical Meteorological Year data are processed to yield hourly average monthly values. These discrete data are then converted to a continuous, time dependent form using a Fast Fourier Transform method. This study is conducted using weather data from four different locations in the United States: Albuquerque, New mexico; Miami, Florida; Santa Maria, California; and Washington D.C. for both winter and summer conditions. A computer code is developed to calculate the wall temperature profile, room air temperature, and energy consumption loads. Three sets of results are calculated one for no auxiliary energy and two for different control mechanism -- an on-off controller and a proportional controller. Comparisons are made for the cases of two controllers. Heavy weight houses with insulation in mild weather areas (such as August in Santa Maria, California) show a high comfort level. Houses using proportional control experience a higher comfort level in comparison to houses using on-off control. The result shows that there is an effect of mass on the thermal performance of a heavily constructed house in mild weather conditions.

Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals

  • Ly, Suw Young;Kim, Dae Hong;Lee, Ga Eun
    • Toxicological Research
    • /
    • v.29 no.3
    • /
    • pp.211-215
    • /
    • 2013
  • The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

Bioconcentration of Pirimiphos-methyl in Killifish (Oryzias latipes)

  • Seo, Jong-Su;Chang, Hee-Ra;Hamer, Mick;Kim, Kyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.4
    • /
    • pp.453-461
    • /
    • 2009
  • Killifish (Oryzias latipes) were exposed to an organophosphate pesticide, pirimiphos-methyl, in a flow-through system to determine the bioconcentration factor (BCF) following GLP (Good Laboratory Practice). This study was conducted at two different concentrations (1 and $10\;{\mu}$g/L) of $^{14}C$-labeled pirimiphos-methyl for 28 days uptake and 14 days depuration according to the OECD 305 test guideline. The $BCF_{ss}$ for total radioactive residues in whole fish were 1,251 and 1,277 for low and high concentrations, respectively. The $BCF_k$ based on the uptake and depuration rate constants were 1,200 for both low and high concentrations. During the depuration phase, the accumulated test substance was rapidly depurated from fish. Greater than 95% of the residue at steady-state was depurated after 2 days. Although the measured BCF values were high, pirimiphos-methyl could be evaluated as a low risk from bioaccumulation by aquatic organisms due to the short depuration period and low amount of bound residue (1.5%). We suggest that in evaluating bioaccumulation, not only the BCF should be considered, but also depuration time and bound residue in aquatic organisms give an indication of the potential environmental risks.

A Study of Determination of Minimum Detectable Activity at Measuring of Pu Isotopes in Environmental Samples (환경시료 중 Pu 측정에서 최소검출방사능 농도 산출에 대한 연구)

  • Lee, Myung-Ho;Cho, Young-Hyun;Choi, Gun-Sik;Lee, Chang-Woo;Shin, Hyun-Sang
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.64-71
    • /
    • 2001
  • In this paper, the formula of lower limit of detection considering the measuring time of sample and background was derived using the basic concepts of lower limit of detection. Among parameters affecting the determination of MDA value, the MDA values were calculated with variation of amount of sample and measuring time of sample and background. The results of adequate division between the measuring time of sample and that of background studied in this research make it possible to evaluate confidence limits on the radio analytical results in the environmental sample.

  • PDF