• Title/Summary/Keyword: analysis with repeated measurements

Search Result 139, Processing Time 0.029 seconds

Effects of Y-Balance Exercise on Spatio-temporal Gait Parameters in Subjects with Chronic Ankle Instability (Y-균형 운동이 만성적 발목 불안정성을 가진 사람들의 시거리 보행 변수에 미치는 영향)

  • Geun Tae Park;Min Ji Kang;Jin Tae Han
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.1
    • /
    • pp.70-87
    • /
    • 2024
  • Background: This study aimed to investigate the effect of Y-balance exercise on spatio-temporal gait parameters in subjects with chronic ankle instability. Design: Randomized Controlled Trial. Method: A study was conducted on 43 people with chronic ankle instability. Subjects performed modified Y-balance exercise 3 times a week for 50 minutes, 4 weeks. Gait parameters were measured using a gait analysis treadmill before exercise, 2 weeks after exercise, and 4 weeks after exercise. A gait analysis treadmill (FDM-T AP1171, Zebris, Germany) was used to measure gait parameters. Mean values were compared using Repeated measured two-way ANOVA. Result:: When comparing the results of three measurements taken before exercise, 2 weeks after exercise, and 4 weeks after exercise, there were significant differences in the qualitative and quantitative aspects of gait in gait variables such as step distance, step time, step ratio, and sway ratio. Conclusions: These results suggest that the Y-balance exercise and various exercises combining balance and proprioception are effective for subjects with chronic ankle instability.

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

A Study on Inverse Problem of Materials Forming Process using Optimization Technique and Distributed Computing (최적화 기법과 분산 컴퓨팅을 이용한 재료 성형공정의 역문제에 관한 연구)

  • Choi, Joo-Ho;Oh, Dong-Gil;Ha, Duk-Sik;Kim, Jun-Bum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.632-639
    • /
    • 2004
  • In this paper, an inverse problem of glass forming process is studied to determine a number of unknown heat transfer coefficients which are imposed as boundary conditions. An analysis program for transient heat conduction of axi-symmetric dimension is developed to simulate the forming and cooling process. The analysis is repeated until it attains periodic state, which requires at least 30 cycles of iteration. Measurements are made for the temperatures at several available time and positions of glass and moulds in operation. Heat removal by the cooling water from the plunger is also recorded. An optimization problem is formulated to determine heat transfer coefficients which minimize the difference between the measured data and analysis results. Significant time savings are achieved in finite difference based sensitivity computation during the optimization by employing distributed computing technique. The analysis results by the optimum heat transfer coefficients are found to agree well with the measured data.

Applicability Evaluation of a Mixed Model for the Analysis of Repeated Inventory Data : A Case Study on Quercus variabilis Stands in Gangwon Region (반복측정자료 분석을 위한 혼합모형의 적용성 검토: 강원지역 굴참나무 임분을 대상으로)

  • Pyo, Jungkee;Lee, Sangtae;Seo, Kyungwon;Lee, Kyungjae
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.1
    • /
    • pp.111-116
    • /
    • 2015
  • The purpose of this study was to evaluate mixed model of dbh-height relation containing random effect. Data were obtained from a survey site for Quercus variabilis in Gangwon region and remeasured the same site after three years. The mixed model were used to fixed effect in the dbh-height relation for Quercus variabilis, with random effect representing correlation of survey period were obtained. To verify the evaluation of the model for random effect, the akaike information criterion (abbreviated as, AIC) was used to calculate the variance-covariance matrix, and residual of repeated data. The estimated variance-covariance matrix, and residual were -0.0291, 0.1007, respectively. The model with random effect (AIC = -215.5) has low AIC value, comparison with model with fixed effect (AIC = -154.4). It is for this reason that random effect associated with categorical data is used in the data fitting process, the model can be calibrated to fit repeated site by obtaining measurements. Therefore, the results of this study could be useful method for developing model using repeated measurement.

Effects of the Gait Variable While Using Smartphones During Ramp Gait in Young Adults (젊은 성인에서 경사로 보행 시 스마트폰 사용이 보행 변수에 미치는 영향)

  • Yoon, Chae-Hyo;Kim, Bum-Su;Kang, Do-Young;Kim, Yeonseo;Lee, Myoung-Hee
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.261-267
    • /
    • 2021
  • Purpose: This study aimed to investigate changes in gait variables depending on whether a task was performed using a smartphone while walking on a ramp. Methods: The participants of this study were 41 college students attending U University located in Gyeongju City, Gyeongsangbuk-do. In this study, gait variables were measured during ramp gait while using a smartphone to perform a task and during ramp gait without performing such tasks. In other words, four walking conditions were used: 1) walking up a ramp, 2) walking up a ramp while using a smartphone to perform a task, 3) walking down a ramp, and 4) walking down a ramp while using a smart phone to perform a task. Gait variables were measured using a gait analysis tool (Legsys; BioSensics, USA), and stride time, stride length, stride velocity, cadence, and double support were analyzed. The order of measurements was randomized to control for order effects due to repeated measurements. Results: The comparative analysis of gait variables according to the presence or absence of smartphone use during ramp gait showed that there were significant differences in stride time, stride length, and stride velocity during both ramp ascent and ramp descent (p < 0.05). In both ramp ascent and ramp descent, stride time increased when walking using a smartphone, compared to when walking without using a smartphone (p < 0.05). However, in both ramp ascent and ramp descent, stride length and stride velocity were decreased when walking using a smartphone compared to when walking without using a smartphone (p < 0.05). Conclusion: The study results showed that the use of a smartphone during walking can affect safety. Therefore, it is necessary to improve the awareness of risks associated with walking while using a smartphone, and further research needs to be conducted in various environments and with different ramps.

The relationship between initial implant stability quotient values and bone -to-implant contact ratio in the rabbit tibia

  • Park, In-Phill;Kim, Seong-Kyun;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.2
    • /
    • pp.76-80
    • /
    • 2011
  • PURPOSE. Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS. Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS. Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION. In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

Effect of Improved Surface Wetability and Adhesion of Undulated Diamond-like Carbon Structure with r.f. PE-CVD

  • Jang, Young-Jun;Kim, Seock-Sam
    • KSTLE International Journal
    • /
    • v.9 no.1_2
    • /
    • pp.22-25
    • /
    • 2008
  • This paper investigated the wetting and adhesion property of undulated DLC film with surface morphology controlled for a reduced real area of contact. The undulated DLC Films were prepared by 13.56 MHZ radio frequency plasma enhanced chemical vapor deposition (r.f. PECVD) by using nanoscale Cu dots surface on a Si (100) substrate. FE-SEM, AFM analysis showed that the after repeated deposition and plasma induced damage with Ar ions, the surface was nanoscale undulated. This phenomenon changed the surface morphology of DLC surface. Raman spectra of film with changed morphology revealed that the plasma induced damage with Ar ions significantly suppressed the graphitization of DLC structure. Also, it was observed that while the untreated flat DLC surfaces had wetting angle starting ranged from $72^{\circ}$ and adhesion force of 333ni. Had wetting angle the undulated DLC surfaces, which resemble the surface morphology of a cylindrical shape, increased up to $104^{\circ}$ and adhesion force decreased down to 11 nN. The measurements agree with Hertz and JKR models. The surface undulation was affected mainly by several factors: the surface morphology affinity to cylindrical shape, reduction of the real area of contact and air pockets trapped in cylindrical asperities of the surface.

Effects of Transcutaneous Electrical Nerve Stimulation and Microcurrent Electrical Neuromuscular Stimulation on Delayed Onset Muscle Soreness (지연성 근육통에 대한 경피신경 전기자극과 미세전류 신경근 자극의 효과 비교)

  • Jung, Young-Jong;Gho, Su-Jeong;You, Hye-Young;Jung, Do-Young
    • Physical Therapy Korea
    • /
    • v.7 no.2
    • /
    • pp.76-87
    • /
    • 2000
  • Delayed onset muscle soreness (DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to determine the effects of both transcutaneous electrical nerve stimulation (TENS) and microcurrent electrical neuromuscular stimulation (MENS) on DOMS, Twenty-seven untrained and male volunteer subjects were randomly assigned to one of three treatment groups: 1) a group that received TENS (7 Hz), 2) MENS (60 ${\mu}A$, .3 pps) or 3) a control group that received no treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24 hours and 48 hours. Subjects attended on two consecutive days for treatment and measurement of elbow flexion, extension, resting angle (universal goniometer), and pain (visual analogue scale: VAS) on a daily basis. Measurements were taken after treatment. Analysis of results were as follows; 1) There were no significant differences between TENS and MENS by one-way repeated ANOVA, 2) The t-test for pain, resting, flexion and extension angle revealed significant differences within TENS group, 3) The t-test for resting angle revealed significant differences within MENS group.

  • PDF

An empirical study on the selection of the optimal covariance pattern model for the weight loss data (체중감량자료에 대한 적정 공분산형태모형 산출에 관한 실증연구)

  • Jo, Jin-Nam
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.2
    • /
    • pp.377-385
    • /
    • 2009
  • Twenty five female students in Seoul participated and were divided into two group in the experiment of weight loss effect of two treatments. Fourteen students(Treatment A group), randomly chosen from the students, had fed on diet foods and exercised over 8 weeks, and the remaining students(Treatment B group) had fed on diet foods only for the same periods. Weights of 25 students had been measured repeatedly four times at an interval of two weeks during 8 weeks, It resulted from mixed model analysis of repeated measurements data that separate Toeplitz pattern for each treatment group was selected as the optimal covariance pattern. Based upon the optimal covariance pattern model, the baseline effect and time effect were found to be highly significant, but the treatment-time interaction effect was found to be insignificant. Finally, the students with diet foods and exercises were more effective in losing weight than the students with only diet foods were.

  • PDF